Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

MTW-OPAL: a technology development platform for ultra-intense optical parametric chirped-pulse amplification systems

Optical parametric chirped-pulse amplification implemented using multikilojoule Nd:glass pump lasers is a promising approach for producing ultra-intense pulses (>10 23 W/cm 2 ). We report on the MTW-OPAL Laser System, an optical parametric amplifier line (OPAL) pumped by the Nd:doped portion of the multi-terawatt (MTW) laser. This midscale prototype was designed to produce 0.5-PW pulses with technologies scalable to tens of petawatts. Technology choices made for MTW-OPAL were guided by the longer-term goal of two full-scale OPALs pumped by the OMEGA EP to produce 2 × 25-PW beams that would be co-located with kilojoule–nanosecond ultraviolet beams. Several MTW-OPAL campaigns that have been completed since “first light” in March 2020 show that the laser design is fundamentally sound, and optimization continues as we prepare for “first-focus” campaigns later this year.

42 ENGINEERING↗

Multilevel atomic structural model for interstratified opal materials

The structure of opal has long fascinated scientists. It occurs in a number of structural states, ranging from amorphous to exhibiting features of stacking disorder. Opal-CT, where C and T signify cristobalite- and tridymite-like interstratification, represents an important link in the length scales between amorphous and crystalline states. However, details about local atomic (dis)order and arrangements extending to long-range stacking faults in opal polymorphs remain incompletely understood. Here, a multilevel modeling approach is reported that considers stacking states in correlation with the abundance of C and T segments as a high-level structural parameter (i.e. not each atom). Optimization accounting for inter-tetrahedral bond lengths and angles and the regularity of the silicate tetrahedra is included as lower levels of structural parameters. Together, a set of parameters with both coarse-grained and atomistic features for different levels of structural details is refined. Structural disorder at the ~10–100 Å distance scale is evaluated using experimental pair distribution function and diffraction datasets, comparing peak intensities, widths and asymmetry. Here this work presents a complete multilevel structural description of natural opal-CT and explains many of the unusual features observed in X-ray powder diffraction patterns. This modeling approach can be adopted generally for analyzing layered materials and their assembly into 3D structures.

36 MATERIALS SCIENCE↗

Laser system design and critical technologies for the NSF OPAL project

The three-year NSF OPAL project is completing the preliminary design of a 2 x 25-PW all-optical parametric chirped-pulse amplification (OPCPA) system capable of delivering 500-J, 20-fs pulses. The design includes two Alpha beamlines that can be co-timed and pointed into two experimental areas for high-intensity research in several configurations. Additionally, a more flexible 2-PW Beta beam can be used in place of one Alpha beam to allow a wider range of focusing geometries and synchronized electron-beam generation for diverse experimental applications. Here, building on the development of the mid-scale MTW-OPAL prototype system, the NSF OPAL project also focuses on advancing essential technologies, such as large-grating fabrication techniques and actively-cooled disk amplifiers.

42 ENGINEERING↗

Benchmarking collective effects of electron interactions in a wiggler with OPAL-FEL

OPAL-FEL is a recently developed tool for the modeling of particle accelerators containing wigglers or undulators. It extends the well established 3D electrostatic particle-tracking code OPAL, by merging it with the finite-difference time-domain electromagnetic solver MITHRA. We present results of two benchmark cases where OPAL-FEL simulations are compared to experimental results. Both experiments concern electron beamlines where the longitudinal phase space is modulated with a short magnetic wiggler. Good agreement was found in both the space charge and radiation dominated regimes.

43 PARTICLE ACCELERATORS↗

Enhanced condensation heat transfer using porous silica inverse opal coatings on copper tubes

Abstract Phase-change condensation is commonplace in nature and industry. Since the 1930s, it is well understood that vapor condenses in filmwise mode on clean metallic surfaces whereas it condenses by forming discrete droplets on surfaces coated with a promoter material. In both filmwise and dropwise modes, the condensate is removed when gravity overcomes pinning forces. In this work, we show rapid condensate transport through cracks that formed due to material shrinkage when a copper tube is coated with silica inverse opal structures. Importantly, the high hydraulic conductivity of the cracks promote axial condensate transport that is beneficial for condensation heat transfer. In our experiments, the cracks improved the heat transfer coefficient from ≈ 12 kW/m 2 K for laminar filmwise condensation on smooth clean copper tubes to ≈ 80 kW/m 2 K for inverse opal coated copper tubes; nearly a sevenfold increase from filmwise condensation and identical enhancement with state-of-the-art dropwise condensation. Furthermore, our results show that impregnating the porous structure with oil further improves the heat transfer coefficient by an additional 30% to ≈ 103 kW/m 2 K. Importantly, compared to the fast-degrading dropwise condensation, the inverse opal coated copper tubes maintained high heat transfer rates when the experiments were repeated > 20 times; each experiment lasting 3–4 h. In addition to the new coating approach, the insights gained from this work present a strategy to minimize oil depletion during condensation from lubricated surfaces.

Adera, Solomon↗

Effect of Lateral Conduction in a Rectangular Fuel Plate and Optimum Stripe Widths for the OPAL Reactor

The impetus for this work is the Proliferation Resistance Optimization (PRO-X) program, which was created by the National Nuclear Security Administration (NNSA) of the US Department of Energy (DOE) to provide a framework for developing reactor designs that minimize the production of special nuclear materials while maximizing performance for peaceful uses. The Argentine company INVAP and Argonne National Laboratory collaborated to share knowledge and expertise regarding the thermal analysis of research reactors. Working together, they designed a series of test problems based on the Open Pool Australian Light Water (OPAL) reactor, whose fuel is in the form of flat plates cooled by water flowing through narrow rectangular channels. ANL used their PLTEMP/ANL code. INVAP used their TERMIC code (and its new multi-plate version, TERMIC-MP). Then, INVAP and ANL compared the two sets of results. 1-D models were used during the collaboration since for research reactor analysis, largely 1-D thermal-hydraulics models are commonly used because they are simple to apply and technically defendable. The collaboration between the two organizations aims for improvements in thermal-hydraulic models. Improvements to methods and models can reduce modeling uncertainties and excessive conservatism, allowing greater reactor performance without reducing predicted safety margins. Therefore, these improvements potentially expand the design space, making additional designs feasible, which, in turn, may achieve better fuel utilization and proliferation resistance in the designs. This report provides justification for the lateral node size (stripe width) chosen for the 1-D computer models during the collaboration. The lateral heat conduction in OPAL fuel plates is evaluated using the two-dimensional conduction capability of PLTEMP/ANL to determine a representative hot-stripe width that can be conservatively used for one-dimensional steady-state thermal-hydraulic analysis. Basically, a representative hot-stripe width needs to be selected so that the actual heat flux averaged over this stripe width is greater than or equal to the maximum heat flux obtained by the two-dimensional analysis. Detailed results in this report show that a hot-stripe width of 8.125 mm can be conservatively used for the one-dimensional thermal-hydraulics analysis of all plates. Therefore, eight equal stripes (8.125 mm each) are recommended to be modeled in the MCNP and PLTEMP/ANL full core models of the OPAL reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mitigation of Boiling-Induced Thermal Degradation Using Microporous Nickel Inverse Opals Structures

Engineered microporous structures have received much attention in high-heat-flux electronics cooling due to their high thermal conductivity and permeability, and large surface area for heat transfer, but are susceptible to boiling-induced thermal degradation. Here, this study investigates the efficacy of nickel inverse opals (NiIOs) in mitigating structural degradation caused by corrosion-assisted erosion during pool boiling with water as the working fluid. First, we compared the reliability of NiIOs to copper inverse opals (CuIOs) for a 3-day pool boiling test at constant heat flux. The NiIOs demonstrated superior resistance to thermal degradation due to their inherent corrosion resistance and mechanical strength. Subsequently, we conducted a more controlled experiment to show the effect of heat flux on the degradation of the NiIOs while excluding the effect of temperature variations. Pool boiling tests of 20-μm-thickness NiIOs covering an area of ∼11 × 11 mm 2 with a 2.5 × 2.5 mm 2 heater at the center were conducted at heat flux levels of 20%, 40%, and 60% of the critical heat flux (CHF) for 3 days. The NiIOs subjected to heat flux levels of 20% and 40% CHF showed minimal degradation, while the sample subjected to 60% CHF showed erosion on the top surface due to higher bubble formation and departure rate. These results show the potential of NiIOs as a promising solution for long-term thermal management in high-power electronic devices, although design considerations for maximum allowable heat flux are necessary for reliable operation.

36 MATERIALS SCIENCE↗

Highly-detailed neutronic and thermal-hydraulic coupled calculations for OPAL reactor using diverse codes and approaches

The industry-standard approach for designing and operating research reactors cores relies on well-established methodologies that consider uncoupled neutronic calculations and a subchannel analysis of the Thermal-Hydraulic (TH) associated problem. Advancements in computing power and codes allow detailed Multiphysics approaches to be implemented, thereby reducing conservatism. In this study, a comparative analysis of results from diverse detailed neutronic-TH coupled core approaches is developed. To address a realistic application case, the comparison is made for a reported critical configuration from the Open Pool Australian Lightwater research reactor (OPAL) at Hot Full Power (HFP) and low burnup. Both cell-core and stochastic methodologies for neutronics are evaluated, whereas two different subchannel codes are considered for TH. In conclusion, the convergence of the coupled schemes, and the consistency of the main parameters are discussed, showing the compatibility of the alternative methods and their ability to offer critical insights not captured by standard practices.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Development of a broadband reflective phase retarder to generate circularly polarized light for MTW-OPAL and multipetawatt lasers

Here, our research focuses on designing metallic coatings to create broadband all-reflective phase retarders that generate circularly polarized (CP) light for the MTW-OPAL Laser System while ensuring the desired polarization state on the target. This all-reflective phase retarder can function as a phase retarder when used in an out-of-plane configuration, whereas it acts as a normal mirror set in an in-plane configuration. If the polarization of the beam is not purely s- or p-polarized, however, mirrors will in general introduce retardance, and therefore compensators or polarization-independent mirror pairs are needed to ensure the desired polarization at the target plane.

47 OTHER INSTRUMENTATION↗