Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPERATING COST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Climate-Induced Tradeoffs in Planning and Operating Costs of a Regional Electricity System

Electricity grid planners design the system in order to supply electricity to end users reliably and affordably. Climate change threatens both objectives through potentially compounding supply- and demand-side climate-induced impacts. Uncertainty surrounds each of these future potential impacts. Given long planning horizons, system planners must weigh investment costs against operational costs under this uncertainty. Here, we developed a comprehensive and coherent integrated modeling framework combining physically-based models with cost-minimizing optimization models in the power system. We applied this modeling framework to analyze potential tradeoffs in planning and operating costs in the power grid due to climate change in the Southeast U.S. in 2050. We find that planning decisions that do not account for climate-induced impacts would result in a substantial increase in social costs associated with loss of load. These social costs are a result of under-investment in new capacity and capacity deratings of thermal generators when we included climate change impacts in the operation stage. Finally, these results highlight the importance of including climate change effects in the planning process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Feasibility and operating costs of an air cycle for CCHP in a fast food restaurant

This work considers the possibilities of an air-based Brayton cycle to provide the power, heating and cooling needs of fast-food restaurants. A model of the cycle based on conventional turbomachinery loss coefficients is formulated. The heating, cooling and power capabilities of the cycle are extracted from simulation results. Power and thermal loads for restaurants in Knoxville, TN and in International Falls, MN, are considered. It is found that the cycle can meet the loads by setting speed and mass flow-rate apportionment between the power and cooling functional sections. The associated energy costs appear elevated when compared to the cost of operating individual components or a more conventional, absorption-based CHP system. Lastly, a first-order estimate of capital investments is provided. Suggestions for future work whereby the operational costs could be reduced are given in the conclusions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Historical and Current Trends in Wind Energy Operations Costs and Project Availability: July 2012 - July 2013

This subcontract report details work completed by Garrad Hassan America, Inc. (GL GH) and provides charts, figures and qualitative opinions on trends in wind energy operations costs and reliability in the United States. This work was used to support the development an NREL historical turbine operating cost and reliability baseline. The results presented have been developed from a database maintained by GL GH containing the operating costs for 66 wind projects in North America with over 5,000 wind turbines and approximately 7,000 MW of capacity. maintained by GL GH containing the operating costs for 66 wind projects in North America with over 5,000 wind turbines and approximately 7,000 MW of capacity.

17 WIND ENERGY↗

Economic Efficiency and Hourly Operational Cost of High-Speed Equipment

The hourly operating cost of equipment provides an assessment of its operational efficiency, in monetary terms. Often, enterprises need to assess product quality. By the proposed method, without complex cost/benefit calculations, the proportion of the cost corresponding to each piece of equipment in a production system may be calculated simply on the basis of the labor intensity of machining and the operational efficiency OEE of the equipment. It is also useful for managers and workers to know the cost of an hour of downtime for particular equipment and to understand the losses in the shop and the enterprise as a whole. Such awareness assists in loss prevention.

42 ENGINEERING↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Regional and Seasonal Characteristics on Battery Electric Vehicle Operational Costs in the U.S.

This study investigates the operational cost competitiveness of battery electric vehicles (BEVs) in the United States, considering regional climates, energy prices, and driving patterns. By comparing BEVs with plug-in hybrid electric vehicles (PHEVs), hybrid electric vehicles (HEVs), and the alternative use of BEVs and conventional vehicles (Convs), the analysis incorporates thermal dynamometer tests, real-world vehicle miles traveled (VMT), and state-specific energy prices. Using detailed simulations, the study evaluates energy consumption across varying temperatures and driving distances. The findings reveal that, while BEVs remain cost-effective for short trips in moderate climates, PHEVs are more economical for long-range trips and cold environments, due to the excessive cost of using external direct current fast chargers (DCFCs) and reduced BEV efficiency at low temperatures. HEVs are identified as the most cost-efficient option in regions like New England, characterized by high residential electricity prices. These insights are critical for shaping vehicle electrification strategies, particularly under diverse regional and seasonal conditions, and for advancing policies on alternative energy and fuels.

Kim, Kyung-Ho (ORCID:0009000450851732)↗

Optimal Efficiency and Operational Cost Savings: A Framework for Automated Rooftop PV Placement

Residential energy consumers are charged based on a utility rate structure, such as net metering or feed-in tariff. To lower consumers' electricity bills, expensive batteries are deployed to reduce the electricity fed from the grid during peak hours. However, strategic photovoltaic (PV) panel placement enables the reduction of operational energy cost while considering the spatial feasibility and efficiency for hosting rooftop PV. In this paper, we present a framework to automatically identify the optimal location of rooftop PV panels on residential buildings. Our framework integrates multiple workflows, including energy and environmental simulation, parametric modeling, and optimization to identify the ideal location of PV panels to balance the demand and supply at a building and community scale. These workflows are linked using the Grasshopper plug-in for Rhinoceros CAD software. The framework includes two different workflows, each satisfying a target for optimal PV placement: (a) maximizing PV panel efficiency, where users aim to maximize energy generation, and (b) minimizing operational energy cost, where "best'' panels are selected considering utility rates for operational energy cost. Our framework is demonstrated in a residential community in Fort Collins, Colorado, to generate the optimal PV placement for each of the two aforementioned targets. Results from the two workflows are compared to illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost. The developed workflows are introduced as tools within the Grasshopper plug-in to investigate the solar potential of rooftop PV panels while taking into account factors such as contextual shading, utility rate structures, and buildings' energy demand profiles.

30 DIRECT ENERGY CONVERSION↗

A heat & mass integration approach to reduce capital and operating costs of a distillation configuration

We propose a general method to consolidate distillation columns of a distillation configuration using heat and mass integration. The proposed method encompasses all heat and mass integrations known till date, and includes many more. Each heat and mass integration eliminates a distillation column, a condenser, a reboiler and the heat duty associated with a reboiler. Thus, heat and mass integration can potentially offer significant capital and operating cost benefits. In this talk, we will study the various possible heat and mass integrations in detail, and demonstrate their benefits using case studies. This work will lay out a framework to synthesize an entire new class of useful configurations based on heat and mass integration of distillation columns.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Framework for Optimal Placement of Rooftop Photovoltaic: Maximizing Solar Production and Operational Cost Savings in Residential Communities

Optimizing the placement of photovoltaic (PV) panels on residential buildings has the potential to significantly increase energy efficiency benefits to both homeowners and communities. Strategic PV placement can lower electricity costs by reducing the electricity fed from the grid during on-peak hours, while maintaining PV panel efficiency in terms of the amount of solar radiation received. In this article, we present a framework that identifies the ideal location of PV panels on residential rooftops. Our framework combines energy and environmental simulation, parametric modeling, and optimization to inform PV placement as it relates to and affects the entire community (in terms of both energy use and financial cost), as well as individual buildings. Ensuring that our framework accounts for shading from nearby buildings, different utility rate structures, and different buildings’ energy demand profiles means that existing communities and future housing developments can be optimized for energy savings and PV efficiency. The framework comprises two workflows, each contributing to optimal PV placement with a unique target: (a) maximizing PV panel efficiency (i.e., solar generation) and (b) minimizing operational energy cost considering utility rate structures for operational energy. We apply our framework to a residential community in Fort Collins, Colorado, to demonstrate the optimal PV placement, considering the two workflow targets. Here, we present our results and illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost.

14 SOLAR ENERGY↗

Assessing wind power operating costs in the United States: Results from a survey of wind industry experts

This paper draws on a survey of wind industry professionals to clarify trends in the operational expenditures (OpEx) of U.S. land-based wind power plants. We find that average all-in lifetime OpEx has declined from approximately $80/kW-yr (~$35/MWh) for projects built in the late 1990s to a level approaching $40/kW-yr (~$11/MWh) for projects built in 2018. Turbine operations and maintenance costs represent the single largest component of overall OpEx and the primary source of cost reductions. We observe wide ranges of OpEx over time; respondents cite a range in average expected costs for recently commissioned projects from $33/kW-yr to $59/kW-yr. We also use historical OpEx learning rates, showing a 9% OpEx reduction for each doubling of global wind capacity, to project a further $5-$8/kW-yr reduction from 2018 to 2040. These findings suggest that continued OpEx reductions may contribute 10% or more of the expected reductions in land-based wind's levelized cost of energy. Moreover, these estimates understate the importance of OpEx owing to the multiplicative effects through which operational advancements influence not only operations and maintenance costs but also component reliability, performance, and plant-level availability - thereby also affecting levelized costs by enhancing annual energy production and plant lifetimes. Given the limited quantity and comparability of previously available OpEx data, the trends reported here may inform OpEx assumptions used by electric planners, analysts, and modelers. The results may also provide useful benchmarks to the wind industry, helping developers and asset owners compare their expectations with historical experience and other industry projections.

17 WIND ENERGY↗

Benchmarking Wind Power Operating Costs in the United States: Results from a Survey of Wind Industry Experts

This paper draws on a survey of wind industry professionals to clarify trends in the operational expenditures (OpEx) of U.S. land-based wind power plants. The paper also highlights key drivers of those trends. We find that average all-in lifetime OpEx has declined from approximately $\$$80/kW-yr ($\$$35/MWh) for projects built in the late 1990s to a level that is approaching $\$$40/kW-yr ($\$$11/MWh) for projects under construction in 2018. Turbine operations and maintenance (O&M) costs—inclusive of scheduled and unscheduled maintenance—represent the single largest component of overall OpEx and the primary source of cost reductions over the last decade. We observe wide ranges of OpEx over time; for example, survey respondents cite a range in average expected costs for projects commissioned between 2015 and 2018 from $\$$33/kW-yr to $\$$59/kW-yr. Notably, these broad ranges include high levels of variability in both turbine O&M costs and non-turbine OpEx. Potential technical and strategic drivers of this variability are highlighted. We also use historical OpEx learning rates, showing a 9% OpEx reduction for each doubling of global installed wind capacity, to project a further $\$$5–$\$$8/kW-yr (12%–18%) OpEx reduction from 2018 to 2040. When compared with the broader literature, these findings suggest that continued OpEx reductions may contribute 10% or more of the expected reductions in land-based wind’s levelized cost of energy. Moreover, these estimates may understate the importance of OpEx owing to the multiplicative effects through which operational advancements influence not only O&M costs but also component reliability, performance, and plant-level availability—thereby affecting levelized costs though OpEx reduction and by enhancing annual energy production and plant lifetimes. Given the limited quantity and comparability of previously available OpEx data, the data and trends reported here may usefully inform OpEx assumptions used by electric system planners, analysts, modelers, and research and development managers. The results may also provide useful benchmarks to the wind industry, helping developers and asset owners compare their OpEx expectations with historical experience and other industry projections.

17 WIND ENERGY↗