Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPERATIONAL IMPACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Operational Impacts of Operating Reserve Demand Curves on Production Cost and Reliability: Preprint

The electric power industry landscape is continually evolving. As emerging technologies such as wind, solar, electric vehicles, and energy storage systems become more cost-effective and present in the system, traditional power system operating strategies will need to be reevaluated. The presence of wind and solar generation (commonly referred to as variable generation) may result in an increase in the variability and uncertainty of the net load profile. One mechanism to mitigate this is to schedule and dispatch additional operating reserves. These operating reserves aim to ensure that there is enough capacity online in the system to account for the increased variability and uncertainty occurring at finer temporal resolutions. A new operating reserve strategy, referred to as flexibility reserve, has been introduced in some regions. A similar implementation is explored in this paper, and its implications on power system operations are analyzed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operational Impacts of Operating Reserve Demand Curves on Production Cost and Reliability

The electric power industry landscape is continually evolving. As emerging technologies such as wind, solar, electric vehicles, and energy storage systems become more cost-effective and present in the system, traditional power system operating strategies will need to be reevaluated. The presence of wind and solar generation (commonly referred to as variable generation) may result in an increase in the variability and uncertainty of the net load profile. One mechanism to mitigate this is to schedule and dispatch additional operating reserves. These operating reserves aim to ensure that there is enough capacity online in the system to account for the increased variability and uncertainty occurring at finer temporal resolutions. A new operating reserve strategy, referred to as flexibility reserve, has been introduced in some regions. A similar implementation is explored in this paper, and its implications on power system operations are analyzed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA/MOD Operations Impacts from Shuttle Program

Operations plays a pivotal role in the success of any human spaceflight program. This paper will highlight some of the core tenets of spaceflight operations from a systems perspective and use several examples from the Space Shuttle Program to highlight where the success and safety of a mission can hinge upon the preparedness and competency of the operations team. Further, awareness of the types of operations scenarios and impacts that can arise during human crewed space missions can help inform design and mission planning decisions long before a vehicle gets into orbit. A strong operations team is crucial to the development of future programs; capturing the lessons learned from the successes and failures of a past program will allow for safer, more efficient, and better designed programs in the future. No matter how well a vehicle is designed and constructed, there are always unexpected events or failures that occur during space flight missions. Preparation, training, real-time execution, and troubleshooting are skills and values of the Mission Operations Directorate (MOD) flight controller; these operational standards have proven invaluable to the Space Shuttle Program. Understanding and mastery of these same skills will be required of any operations team as technology advances and new vehicles are developed. This paper will focus on individual Space Shuttle mission case studies where specific operational skills, techniques, and preparedness allowed for mission safety and success. It will detail the events leading up to the scenario or failure, how the operations team identified and dealt with the failure and its downstream impacts. The various options for real-time troubleshooting will be discussed along with the operations team final recommendation, execution, and outcome. Finally, the lessons learned will be summarized along with an explanation of how these lessons were used to improve the operational preparedness of future flight control teams.

Fitzpatrick, Michael↗

Operational Impacts of Large Deployments of Offshore Wind (Poster)

The potential operational impact of deploying 54 GW of offshore wind in the United States was examined. The capacity was not evenly distributed; instead, it was concentrated in regions with better wind quality and close to load centers (Table 1). A statistical analysis of offshore wind power time series was used to assess the effect on the power system. The behavior of offshore wind resembled that of onshore wind, despite the former presenting higher capacity factors, more consistent power output across seasons, and higher variability levels. Thus, methods developed to manage onshore wind variability can be extended and applied to offshore wind.

17 WIND ENERGY↗

Quantifying the Operational Impacts of Cyber Events on Enterprise Network Environments

The "Quantifying the Operational Impacts of Cyber Events on Enterprise Network Environments" Feasibility Study addressed the question: Can an existing (novel) class of network characterization and change detection algorithms previously developed at LLNL for internal enterprise datasets, be effectively applied to assess and measure the analytic value of features derived from datasets composed of passively collected RF and wireless network data?

97 MATHEMATICS AND COMPUTING↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

25 ENERGY STORAGE↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

battery↗

Impact of ideal MHD stability limits on high-beta hybrid operation

Here, the hybrid scenario is a candidate for stationary high-fusion gain tokamak operation in ITER and DEMO. To obtain such performance, the energy confinement and the normalized pressure ${{\beta}_{N}}$ must be maximized, which requires operating near or above ideal MHD no-wall limits. New experimental findings show how these limits can affect hybrid operation. Even if hybrids are mainly limited by tearing modes, proximity to the no-wall limit leads to 3D field amplification that affects plasma profiles, e.g. rotation braking is observed in ASDEX Upgrade throughout the plasma and peaks in the core. As a result, even the small ASDEX Upgrade error fields are amplified and their effects become visible. To quantify such effects, ASDEX Upgrade measured the response to 3D fields applied by $8\times 2$ non-axisymmetric coils as ${{\beta}_{N}}$ approaches the no-wall limit. The full n = 1 response profile and poloidal structure were measured by a suite of diagnostics and compared with linear MHD simulations, revealing a characteristic feature of hybrids: the n = 1 response is due to a global, marginally-stable n = 1 kink characterized by a large m = 1, n = 1 core harmonic due to q min being just above 1. A helical core distortion of a few cm forms and affects various core quantities, including plasma rotation, electron and ion temperature, and intrinsic W density. In similar experiments, DIII-D also measured the effect of this helical core on the internal current profile, providing information useful to understanding of the physics of magnetic flux pumping, i.e. anomalous current redistribution by MHD modes that keeps ${{q}_{\text{min}}}>1$ . Thanks to flux pumping, a broad current profile is maintained in DIII-D even with large on-axis current drive, enabling fully non-inductive operation at high ${{\beta}_{N}}$ up to 3.5–4.

3D equilibrium↗

Smart-1 Moon Impact Operations

This paper describes the operations to control the Moon impact of the 3-axis stabilized spacecraft SMART-1 in September 2006. SMART-1 was launched on 27/09/2003. It was the first ESA mission to use an Electric Propulsion (EP) engine as the main motor to spiral out of the Earth gravity field and reach a scientific moon orbit [1]. During September 2005 the last EP maneuvers were performed using the remaining Xenon, in order to compensate for the 3rd body perturbations of the Sun and Earth. These operations extended the mission for an additional year. Afterwards the EP performance became unpredictable and low, so that no meaningful operation for the moon impact could be done. To move the predicted impact point on the 16/8/2006 into visibility from Earth an alternative Delta-V strategy was designed. Due to their alignment, the attitude thrusters could not be used directly to generate the Delta-V, so this strategy was based on controlled angular momentum biasing. Firing along the velocity vector around apolune, the remaining Hydrazine left from the attitude control budget was used, to shift the impact to the required coordinates.

Ayala, Andres↗

Innovative Approach for Technetium-99 Disposal Reduces Operational Impacts - 16460

The Environmental Management Waste Management Facility (EMWMF) on the Oak Ridge Reservation began receiving and disposing waste with elevated technetium-99 (Tc-99) activities on November 11, 2013. Prior to receipt, the Tennessee Department of Environment and Conservation expressed concerns about potential releases of this highly mobile radionuclide into the environment and requested additional safeguards to minimize potential releases. Several additional requirements were negotiated to address these concerns and allow this waste lot to be safely disposed at EMWMF. Because of the 130-cm (51-inch) annual average precipitation at the landfill, the potential release of Tc-99 (above the release criterion) to surface water during the EMWMF water management activities was of the greatest concern. The EMWMF Operations staff developed an innovative approach to resolve regulator concerns regarding disposal of low-level waste containing elevated levels of Tc-99 at EMWMF. This approach minimized the spread of contamination and the generation of water that contacted the Tc-99 waste. Lessons learned and recommendations are being implemented for the next, more challenging elevated Tc-99 waste from the K-27 Building, currently scheduled for early 2016. These lessons learned are also applicable to other sites looking to minimize operational impacts from disposal of waste with elevated activities of Tc-99 or other highly mobile contaminants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overlooked trade-offs of environmentally protective hydropower operation: Impacts to ancillary services and greenhouse gas emissions

The relicensing of large hydropower projects in the United States often enforces environmental constraints such as minimum instream flows. These requirements can reduce hydropower's negative environmental impacts but may come at a cost of reduced electric generation and revenue. During the federal hydropower relicensing process, participants negotiate these environmental and economic trade-offs based on coarse models, often conflating impacts on generation and revenue, overlooking ancillary services (AS) markets, and ignoring potential greenhouse gas (GHG) implications. Using a case study of a 362-MW hydropower project in California, this research conducts higher resolution modelling to compare energy generation, AS provision, revenue, and GHG impacts of two hydropower operating regimes. The environmentally protective regime reduces average generation by 6% but increases AS provision by 2%. Total average revenue decreases by 3.5% under environmental constraints using current electricity prices (and by only 1.1% when modelled with projected 2030 electricity prices), indicating that generation impacts should not be equated with revenue impacts during relicensing. In the California electricity market, this reduced hydropower generation is replaced primarily by natural gas, resulting in an estimated 30,000 additional tons of CO 2 emitted annually. Furthermore, these positive and negative externalities are not adequately examined in the hydropower relicensing process.

13 HYDRO ENERGY↗

Tug ground operations - An approach to early identification of operational impacts

An approach to early identification of operational requirements is discussed together with an assessment of the impact of these requirements on the development and acquisition phase of a program. The approach is applied to the Space Tug program. Some of the more salient results of the Tug Fleet and Ground Operations Schedules and Controls study performed under a NASA/Marshall Space Flight Center contract are provided. Ground-processing requirements and flows are presented, including a summary of facility requirements, timelines, activities and options/contingency-provision recommendations. Programmatic recommendations resulting from the study are presented in areas of payload integration, activation requirements, fleet utilization, fleet sizing, costs, and WTR delta requirement for the Tug.

Best, J. L.↗

Price Formation and Grid Operation Impacts from Variable Renewable Energy Resources

Increasing amounts of Variable Renewable Energy Resources (VREs) impact electricity markets and their operation. VREs are intermittent, zero marginal cost resources that tend to displace emissions-intensive generators in electricity dispatch, reducing emissions, but impacting price formation, revenue sufficiency, reliability, and market power mitigation processes of electricity markets. But VREs are not the only factor that affects operational and financial challenges in electricity markets. Declining natural gas prices, changing resource mixes, as well as different electricity market designs and regulatory policies all factor into the challenges both electricity market participants and operators face in today’s electricity markets. With this in-depth examination of electricity markets and related literature review, we aim to inform on key challenges of market design and operation for successful integration of large amounts of zero marginal cost resources. We’ve identified several areas, including VREs impact on price formation, revenue sufficiency, reliability, market power monitoring and mitigation, as well as how state-level incentives and market design impact VREs and these challenges. With each key challenge, we survey the literature to answer the question: To what extent is the problem, and how has it evolved over time? We first conduct a thorough review of ongoing challenges in electricity markets to understand the problem and review the empirical literature to capture important findings on how VREs, specifically, impact the problem. From this review, we highlight metrics that are important to understanding VRE integration and how market designs and outcomes are evolving with increasing levels of VREs. We propose several empirical models for future research to determine the impact of VREs on these identified challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assess How Changes in Fuel Cycle Operation Impact Safeguards

Since the beginning of commercial nuclear power generation in the 1960s, the ability of researchers to understand and control the isotopic content of spent fuel has improved. It is therefore not surprising that both fuel assembly design and fuel assembly irradiation optimization have improved over the past 50+ years. It is anticipated that the burnup and isotopics of the spent fuel should exhibit less variation over the decades as reactor operators irradiate each assembly to the optimum amount. In contrast, older spent fuel is anticipated to vary more in burnup and resulting isotopics for a given initial enrichment. Modern fuel therefore should be more uniform in composition, and thus, measured safeguards results should be easier to interpret than results from older spent fuel. With spent fuel ponds filling up, interim and long-­term storage of spent fuel will need to be addressed. Additionally after long periods of storage, spent fuel is no longer self-­protecting and, as such, the IAEA will categorize it as more attractive; in approximately 20 years many of the assemblies from early commercial cores will no longer be considered self-­protecting. This study will assess how more recent changes in the reactor operation could impact the interpretation of safeguards measurements. The status quo for spent fuel assay in the safeguards context is that the overwhelming majority of spent fuel assemblies are not measured in a quantitative way except for those assemblies about to be loaded into a difficult or impossible to access location (dry storage or, in the future, a repository). In other words, when the assembly is still accessible to a state actor, or an insider, when it is cooling in a pool, the inspectorate does not have a measurement database that could assist them in re-­verifying the integrity of that assembly. The spent fuel safeguards regime would be strengthened if spent fuel assemblies were measured from discharge to loading into a difficult or impossible to access location. The primary driver for suggesting this shift in approach is the change in robotic technology and information technology in general. It should be possible, with minimal impact to the facility, to measure each assembly every time that it is moved in the pool, with the first measurements being made at discharge. The following conclusions were reached: The total neutron count rate can be accurately predicted at any future moment in time based upon the measured count rate at discharge, provided the initial enrichment and burnup of the assembly is known at discharge. It is expected that the total neutron count rate measured at discharge will be indicative of the initial enrichment and burnup of that assembly. If the automated robot were to focus on measuring the assemblies in the rack without moving them, the time available would increase immensely.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operational impacts of high penetration solar power on a real-world distribution feeder

Higher penetration of solar photovoltaic (PV), with their uncontrollable generation variability, imposes various grid stability challenges on distribution system operation. The primary problem is significant voltage rise in the distribution feeder that forces existing voltage control devices such as on-load tap-changers and line voltage regulators to operate more frequently. The consequence is the deterioration of the operating life of the voltage control mechanism. The objective of this paper is to investigate the voltage impact of increased penetration of PV systems on distribution load tap changer operations. Both steady-state and quasi-static power flow analyses have been conducted to assess the impact on load tap changes under different solar PV penetration levels. Two real-world distribution feeder circuits are used as a test system in this study. Simulations are carried out for up to one-year period with 1-minute time step using OpenDSS. A comparison study was performed to investigate potential voltage rise issues in the network by increasing total PV penetration from 0 to 100% in the feeder. Results show significant increase in the total number of tap operations as solar PV penetration increases. Impacts on nodal voltages and feeder net power are also presented.

Dong, Jin↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

Daily operational impacts on battery degradation in heavy-duty electric drayage trucks

Battery aging is a critical factor influencing the performance, longevity, and cost of ownership of battery electric trucks (BETs). This paper presents a comprehensive evaluation of battery aging for two Li-ion battery chemistries, Nickel-Manganese-Cobalt (NMC) and Lithium-Iron-Phosphate (LFP), accounting for both cycling and calendar aging. In contrast to traditional methods that rely on simplified linear degradation models based on manufacturer-provided data, this study employs semi-empirical aging models calibrated to experimentally collected data. The models are integrated into a detailed vehicle simulation environment, enabling a comprehensive assessment of battery degradation under realistic operating conditions. A case study focusing on heavy-duty electric drayage truck operations in the Port of Savannah, GA, is presented to illustrate the impact on battery pack lifespan of: seasonal variations, daily operational activities, charging strategies, and battery storage conditions. The results illuminate the significance of the battery pack’s state of charge during stationary periods, such as overnight storage or weekend parking, on battery degradation and its potential implications for long-term vehicle viability. Additionally, the study explores how different operational and environmental factors affect battery degradation, offering critical insights into best battery charging and storage practices. Our results demonstrate that LFP outperforms NMC in terms of years of useful life; however, by utilizing charging strategies that minimize the amount of time the battery spends resting at high levels of state-of-charge, the lifespan of the battery pack that uses NMC can nonetheless be increased by more than a factor of two.

25 ENERGY STORAGE↗