Search NASASearch

SEARCH · Search NASA

Results for “OPTICAL METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Determining the tilt of the Raman laser beam using an optical method for atom gravimeters

The tilt of a Raman laser beam is a major systematic error in precision gravity measurement using atom interferometry. The conventional approach to evaluating this tilt error involves modulating the direction of the Raman laser beam and conducting time-consuming gravity measurements to identify the error minimum. In this work, we demonstrate a method to expediently determine the tilt of the Raman laser beam by transforming the tilt angle measurement into characterization of parallelism, which integrates the optical method of aligning the laser direction, commonly used in freely falling corner-cube gravimeters, into an atom gravimeter. A position-sensing detector (PSD) is utilized to quantitatively characterize the parallelism between the test beam and the reference beam, thus measuring the tilt precisely and rapidly. After carefully positioning the PSD and calibrating the relationship between the distance measured by the PSD and the tilt angle measured by the tiltmeter, we achieved a statistical uncertainty of less than 30 µrad in the tilt measurement. Furthermore, we compared the results obtained through this optical method with those from the conventional tilt modulation method for gravity measurement. The comparison validates that our optical method can achieve tilt determination with an accuracy level of better than 200 µrad, corresponding to a systematic error of 20 µGal in g measurement. This work has practical implications for real-world applications of atom gravimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Characterizing the Impact of Heliostat Size, Focus Method, and Optical Error on Concentrating Solar Tower Systems

Concentrating Solar Power (CSP) tower systems use heliostat fields to direct solar energy to a central receiver. The efficiency of the heliostat field is crucial for achieving thermal generation targets and is also the largest cost component, making up 30-40% of total project costs. Developers face a tradeoff: reducing heliostat costs may decrease optical performance and increase land use, while improving performance could raise manufacturing costs (through higher precision). The optimal design depends on land, labor, and manufacturing costs. Additionally, inherent performance limitations exist - optical errors result in larger solar images as heliostats move farther from the receiver, increasing spillage and attenuation losses. Ultimately, there exists a point where receiver design power can no longer be achieved at design conditions for a given solar field area. This point depends on key heliostat field design parameters including field layout, heliostats size, focus method, and heliostat optical error. In this work, we explore and characterize the performance trade-offs between heliostat size, focus method, and optical error using Monte Carlo ray-tracing simulations using NREL's high performance computing resources. The goal of this fundamental investigation is to understand practical heliostat design performance impacts that can be used to produce more cost-effective heliostat fields while still achieving plant thermal generation targets.

14 SOLAR ENERGY

MODELING AND METHOD FOR OPTICAL PERFORMANCE OF A RECEIVER COATING AND ITS DEGRADATION DUE TO OPERATION

The optical properties of the coating used on a concentrated solar power (CSP)’s receiver directly impact the performance of the power plant. Receiver coatings are designed to absorb as much heat as possible and transfer it to the circulating fluid. Over time, the absorptivity of the receiver coating degrades due to environmental and operational conditions. This project aims to (1) create a test apparatus that allows coatings to undergo accelerated lifetime testing under conditions that mimic what the coating will experience on-tower; and (2) develop a mathematical model that based on the test data predicts absorptivity over time. To create the mathematical model, samples of BrightSource Energy’s Gen1 and Gen2 coatings were tested first looking at individual failure modes (such as high temperature cycling) and then for combined failure modes in the newly developed apparatus. In addition to taking optical measurements, the samples were destroyed to allow for metalogical evaluation to understand what was happening on a microscopic level. Pre-existing models from the literature that describe accelerated testing as well as individual phenomena observed in the coating were then combined to create the model. Additionally, the Gen2 and Gen3 coatings are being testing at the Plataforma Solar de Almería (PSA) facility in Almeria, Spain to confirm that the apparatus test results are similar to those received on-sun. (PSA’s facility closely mimics on-tower conditions). The goal is to enable industry players to test coatings using the new apparatus, gather absorptivity measurements (without needing to destroy samples), and input the information into the model to determine how the coating will perform over time, thus allowing the optical performance of coatings to be compared even before they are used on-tower. The model will be publicly available by the end of the project (currently projected as December 2024).

14 SOLAR ENERGY

Systems and methods for optical sensor protection

The present disclosure relates to an optical sensor protection system. The system may have a sensor for receiving an incoming optical signal, a passive sensing and modulation component, and an active sensing and modulation subsystem. The passive sensing and modulation component is configured to sense when a first characteristic is associated with the incoming optical signal is present that adversely affects operation of the sensor, and redirects at least a portion of the incoming optical signal thereof away from the sensor to thus reduce an intensity of the incoming optical signal reaching the sensor. The sensor is located on an image plane downstream of the ISM subsystem, relative to a path of travel of the incoming optical signal. The active sensing and modulation subsystem has an active modulation component and is located upstream of the passive sensing and modulation component, relative to the path of travel of the incoming optical signal, and is also located on a conjugate image plane, and is configured to use the redirected portion of the incoming optical signal as feedback in controlling a modification of the incoming optical signal to reduce a risk of damage to the passive sensing and modulation component.

Panas, Robert Matthew

Systems and methods for optical measurement of cross-wind

Various technologies pertaining to optical measurement of cross-wind are described herein. A beam of light is emitted along a trajectory through a shooting space from a location of a shooter to a target using a laser. The beam is reflected by the target, and the beam is received at two optical detectors. Due to changes in the index of refraction of air along the path of the beam, an envelope signal atmospherically encoded on the beam is received at each of the two apertures at different times. A signal analyzer receives a signal from each of the detectors and outputs data indicative of an average speed of the cross-wind along the trajectory in the shooting space based upon a time delay between the signals.

Bagwell, Brett

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

42 ENGINEERING

Transition-Metal-Related Quantum Emitters in Wurtzite AlN and GaN

Transition-metal centers exhibit a paramagnetic ground state in wide-bandgap semiconductors and are promising for nanophotonics and quantum information processing. Specifically, there is a growing interest in discovering prominent paramagnetic spin defects that can be manipulated using optical methods. Here, we investigate the electronic structure and magneto-optical properties of Cr and Mn substitutional centers in wurtzite AlN and GaN. We use state-of-the-art hybrid density functional theory calculations to determine level structure, stability, optical signatures, and magnetic properties of these centers. The excitation energies are calculated using the constrained occupation approach and rigorously verified with the complete active space configuration interaction approach. Our simulations of the photoluminescence spectra indicate that $Cr$$^{1+}_{Al}$ in AlN and $Cr$$^{1+}_{Ga}$ in GaN are responsible for the observed narrow quantum emission near 1.2 eV. We compute the zero-field splitting (ZFS) parameters and outline an optical spin polarization protocol for $Cr$$^{1+}_{Al}$ and $Cr$$^{1+}_{Ga}$. Our results demonstrate that these centers are promising candidates for spin qubits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Optical Extinction-Based 3D Nano-Imaging of WS 2 on Gold

Broad band nano-extinction images recorded in the tip-enhanced optical spectroscopy geometry track the 3D topography of a single layer of WS 2 on Au substrate. The described nano-optical method is complementary to conventional AFM and offers additional information about the buried material-metal interface that is not accessible using conventional topographic imaging. Beyond 3D optical imaging, we observe large variations in the junction plasmon resonance on the nanoscale. The latter is important to understand and account for in tip-enhanced Raman and photoluminescence studies that target low-dimensional materials specifically. Further, our observations and (coherent) optical scattering-based method are also relevant to emerging efforts aimed at exploring strong coupling and Fano interferences in hybrid plasmonic-low dimensional quantum material systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Multi-Scale Integrated Monitoring System for Enhancing Methane Emission Detection, Quantification & Prediction

This report details the progress and findings of a comprehensive study on reviewing existing solutions, identifying technology gaps, and formulating an “all-in-one” integrated strategy for developing the next-generation multiscale methane monitoring and modeling platform, conducted under grant number DE-FE0032292. Co-led by Dr. David Ebert, Dr. Binbin Weng, and Dr. Chenghao Wang at the University of Oklahoma, the project’s goal was to develop an integrated approach for building this engineering platform to detect, quantify, and mitigate methane emissions across various temporal scale, spatial scales, and sectors. The planning grant study began with an extensive review of various methane sensing and monitoring technologies and systems, surveying over 100 technology providers globally. This review revealed the prevalence of optical methods over chemical methods in commercially available sensors, with Non-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), and Optical Gas Imaging (OGI) cameras being the most prevalent options. A trend towards more advanced optical techniques was observed, driven by increased regulatory focus and technological advancements. The technical evaluation of these sensing technologies provided crucial insights into their capabilities and limitations. The study examined emerging technologies such as Differential Absorption LiDAR (DIAL), which show promise for high-precision and long-range detection. The team then investigated the features and application bandwidth of various sensing platforms, including handheld, fixed/stationary, mobile, aerials, and spaceborne monitors. Pilot field studies were conducted to assess the capabilities of solutions for different emission scenarios. Field work with sensor deployments was conducted at three distinct site types: an oil & gas industry site, a cattle ranching operation, and a waste processing facility. The team also conducted a thorough review of methane flux inverse modeling approaches, focused on physically based methods. These approaches were categorized into simple, intermediate, and advanced methods. A realtime WRF-GHG (Weather Research and Forecasting-Greenhouse Gas) modeling system was developed and applied, incorporating multiple data sources to guide field experiments and inform methane plume detection. The project identified and analyzed numerous categories of methane data sources, including satellite measurements, ground-based sensors, and inventory databases. Key platforms examined include EDGAR, EPA GHGI, NASA TROPOMI, Carbon Mapper, and Climate TRACE, among others. The team proposed an architecture for a comprehensive methane monitoring platform. This system incorporates multi-source data acquisition, advanced data processing and assimilation, interactive visualization tools, and analytical capabilities for emissions forecasting and scenario analysis. The proposed platform aims to provide a user-friendly interface catering to various stakeholders, from researchers to policymakers. The architecture includes sophisticated data ingestion methods, a centralized data warehouse, and advanced analytical tools for data fusion and interpretation. To ensure the relevance and effectiveness of the proposed system, a comprehensive survey was conducted to gather stakeholder input on system requirements. Key findings include a strong need for integrating various data types and formats, a preference for real-time data updates and advanced visualization tools, and a demand for user-friendly interfaces catering to different expertise levels.

03 NATURAL GAS

Studies of optical and chemical properties of aged and fresh biomass burning absorbing aerosols for climate models

Particulate emissions from burning fuels from sub-Saharan Africa is currently poorly characterized. With increasing population and industrialization, emissions are expected to grow. Optical methods for measuring light absorption in the ultraviolet (UV) and visible (vis) regions of the spectrum are crucial for understanding the optical properties of BB aerosols (Bond and Bergstrom, 2006; Lack and Cappa, 2010; Moschos et al., 2021). One such instrument is the dual-spot AE33 model aethalometer is a common filter-based instrument that can be used to measure aerosol absorption properties (Hansen et al., 1984). This instrument has many figures of merit; however, the method's limitations include potential biases from scattering within the filter material, multiple scattering effects of the particles, filter loading (i.e. particle shadowing), and the need for wavelength-specific correction factors (Cλ), which depend on accurate intercomparison with other in situ techniques (Bond et al., 1999; Collaud Coen et al., 2010). This work aims to: 1. Optically characterize BB aerosol generated from African fuel 2. Correct the aethalometer at multiple wavelengths 3. Parametrize these correction factors. 4. Combusting the same fuels with two difference tube furnace systems assess the general applicability of this flexible means of producing BB aerosol. This was accomplished by conducting laboratory studies at Los Alamos National Laboratory (LANL) and North Carolina A&T State University (NCA&T), where aethalometer measurements were compared to in situ optical measurements. Mass cross sections of BB aerosol from these under-studied fuels will be determined along with their wavelength dependence.

09 BIOMASS FUELS

Quantitative measurement of pebble fuel anisotropy using generalized ellipsometry

The renewed development of high-temperature gas-cooled reactors has created a need to modernize pebble fuel quality control methods. One important specification in these methods is the coefficient of thermal expansion (CTE) anisotropy, which reflects graphite grain alignment and affects fuel performance. This study investigates the feasibility of using two-modulator generalized ellipsometry microscopy (2-MGEM) as a potential surrogate metric for CTE anisotropy. Graphite matrix compacts with controlled levels of anisotropy were fabricated by varying pre-pressures during forming and were subsequently characterized using both optical dilatometry and 2-MGEM. Measured responses were compared to an isotropic reference pebble produced using an industrial manufacturing process to provide a practical baseline. The resulting measurements revealed a strong quantitative correlation between the CTE anisotropy ratio and the corresponding diattenuation ratio. However, propagated measurement uncertainties in the optical method were found to limit definitive pass/fail discrimination, highlighting the need for improved precision before qualification as a quality control tool. Still, the results establish a quantitative relationship between optical and CTE anisotropy and support further development of 2-MGEM as a potential surrogate method for evaluating graphite matrix anisotropy in pebble fuel manufacturing.

Raftery, Alicia [ORNL] (ORCID:0000000259076427)

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION

An Infrared Database of n/k Optical Constants for Calculating Aerosol Spectra for the PICARD Program

The objective of the PICARD Program is to develop fieldable sensing platforms for the rapid chemical identification of aerosol particles in plumes. Standoff detection involves interrogating the aerosol cloud from a distance using optical methods and probing the signal returned from direct backscattering from the aerosol particles or transmitted through the plume after reflection from a retroreflector or surface of opportunity (SOO). The identification of chemical species, however, in aerosols is complicated by their complex compositions and morphologies, chemical interferants, and non-uniform particle sizes. To advance standoff detection of aerosols, modelling the infrared transmittance, reflectance and scattering spectra of aerosolized liquid and solid chemical compounds is required, and then testing that model experimentally via laboratory and field experiments. To perform accurate modeling, the infrared optical constants (n/k), i.e., the complex refractive index, of the compounds of interest are required. Thus, PNNL was tasked to provide the optical constants for a set of analytes relevant to the PICARD program. This report describes the experimental techniques used to derive the optical constants of both liquid and solid compounds using established “gold-standard” protocols, how the experimental data are processed to produce the wavenumber dependent optical constant vectors, and how the data are used in the aerosol absorption spectra modeling.

complex refractive index

In-Cell Deployment and First Use of Digital Image Correlation for In-Situ Strain Analysis of Irradiated Nuclear Fuel Rods During LOCA Transient

Digital image correlation (DIC) is a noncontact, optical method increasingly used across industries and research environments for acquiring multidimensional strain data. At Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS), DIC has been extensively applied to study the thermomechanical response of nuclear fuel claddings, yielding fundamental insights into material behavior. However, these efforts have focused exclusively on unirradiated materials and relied on the SATS out-of-cell infrastructure. Efforts over the past two years have been made to extend these capabilities to ORNL’s Irradiated Fuels Examination Laboratory SATS system within the hot-cells to enable testing of irradiated fuel cladding materials. Integrating DIC into the hot-cell SATS infrastructure presents unique challenges, including enabling remote operation of optical equipment and adapting auxiliary hot-cell systems for DIC implementation. This report discusses design, stand-up testing, and application of DIC to an irradiated nuclear fuel cladding segment. A DIC testing rig was successfully built and validated out-of-cell through extensive surrogate tests and calibrations. The rig and specialized DIC furnace were installed in the hot-cell, and a DIC test was successfully conducted. Results from that test correspond to expectations for Zr-based alloys and showed similar uncertainties compared to out-of-cell tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Topological Magneto-optics in the Noncoplanar Antiferromagnet Co 1/3 ⁢NbS 2 : Imaging and Writing Chiral Magnetic Domains

Despite its tiny net magnetization, the antiferromagnetic (AFM) van der Waals material Co 1/3 ⁢NbS 2 exhibits a large transverse Hall conductivity 𝜎 𝑥⁢𝑦 even at zero applied magnetic field, which arises, as recently shown, from the topological nature of its noncoplanar “tetrahedral” AFM order. Here, this triple-𝐪 magnetic order can be regarded as the short-length-scale limit of a magnetic skyrmion lattice and has an intrinsic spin chirality. Here, we show, using optical wavelengths spanning the ultraviolet to infrared (400–1000 nm), that magnetic circular dichroism provides an incisive optical probe of the topological AFM order in Co 1/3 ⁢NbS 2 . Measurements as a continuous function of photon energy are directly compared with first-principles calculations, revealing the influence of the underlying quantum geometry on optical conductivity. Leveraging the power and flexibility of optical methods, we use scanning magnetic circular dichroism microscopy to directly image chiral AFM domains and demonstrate writing of chiral AFM domains.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.

Aerosol size determination via light scattering of viruses and protein complexes

Abstract The study of ultrafine particle aerosols, those with particle diameters of 100 nm or less, is important due to their impact on our health and environment. However, given their small sizes, such particles can be difficult to measure and trace. Most common optical methods are unable to reach this size range. Other methods exist but incur other limitations, such as the need for electrically charged particles. Here we show how light scattering can be used to detect and measure the size and location of single viruses and protein complexes forming an aerosol beam, as well as trace their path. We were able to detect individual particles down to 16 nm in diameter. The primary purpose of our instrument is to monitor the delivery of single bioparticles to the focus of an X-ray laser to image those particles, but it has the potential to study any other aerosols such as those resulting from ultrafine sea spray, with important consequences for cloud formation and climate modeling, or from combustion, responsible for most air pollution and resulting health impacts.

Physics