Search NASA⌕ Search

SEARCH · Search NASA

Results for “ORGANIC FLUORINE COMPOUNDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Synthesis of fluorinated organic compounds using oxygen difluoride

Oxygen difluoride synthesis is a much simpler, higher-yield procedure than reactions originally followed to synthesize various fluorinated organic compounds. Extreme care is taken in working with oxygen difluoride as its reactions present severe explosion hazard.

Toy, M. S.↗

An automated synthesizer for electrochemical 18 F-fluorination of organic compounds

Electrochemical 18 F-fluorination of organic compounds provides a means to synthesize Positron-Emission-Tomography (PET) tracers difficult to obtain otherwise. The first automated synthesizer that enables radiolabeling through carrier-added electrochemical 18 F-fluorination is described. The system provides capabilities for all necessary operations such as drying of cyclotron derived [ 18 F]fluoride, electrochemical incorporation of the radioisotope into a precursor molecule, subsequent reactions such as protecting group removals, HPLC-purification and formulation of the final tracer. Demonstrated is the aliphatic electrochemical 18 F-fluorination of methyl 2-(phenylthio)acetate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AngioJet Thrombectomy for Occluded Dialysis Fistulae: Outcome Data

This study evaluates AngioJet thrombectomy of occluded autogenous dialysis fistulae and polytetrafluoroethylene (PTFE) grafts in a UK hemodialysis population. Comparison is made with published data of alternative percutaneous thrombectomy methods. All patients with occluded dialysis fistulae who sought care at the Royal Liverpool University Hospital between October 2006 and June 2008 were included in the study. All patients were treated with the AngioJet Rheolytic Thrombectomy Device (Possis, Minneapolis, MN). Demographics, time of occlusion, adjunctive therapies, complications, and follow-up data have been prospectively recorded. A total of 64 thrombectomy procedures were performed in 48 patients. Forty-four autogenous fistulas were treated in 34 patients (19 brachiocephalic, 8 radiocephalic, and 7 transposed brachiobasilic). Twenty PTFE grafts were treated in 14 patients (9 brachioaxillary, 3 brachiocephalic loop grafts, 1 brachiobasilic, and 1 femoro-femoral). The average length of occlusion was 24 cm. Average time to intervention was 4 days. Immediate primary patency was 91%. Primary patency at 1, 3, and 6 months, respectively, was 71%, 60%, and 37%. Secondary patency at 3, 6, and 12 months was 87%, 77%, and 62%, respectively. Angioplasty was carried out in all procedures. Patients required stent insertion in 34 of the 64 thrombectomies to treat angioplasty-resistant stenoses. Complications included a puncture-site hematoma, and three angioplasty-related vein ruptures in one patient, all treated with covered stent grafts. Two cases of distal brachial arterial embolization were successfully treated by thrombosuction. AngioJet thrombectomy in dialysis access occlusion is safe and effective, comparing favorably with other methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ionization by Drift and Ambipolar Electric Fields in Electronegative Capacitive Radio Frequency Plasmas

Unlike {alpha}- and {gamma}-mode operation, electrons accelerated by strong drift and ambipolar electric fields in the plasma bulk and at the sheath edges are found to dominate the ionization in strongly electronegative discharges. These fields are caused by a low bulk conductivity and local maxima of the electron density at the sheath edges, respectively. This drift-ambipolar mode is investigated by kinetic particle simulations, experimental phase-resolved optical emission spectroscopy, and an analytical model in CF{sub 4}. Mode transitions induced by voltage and pressure variations are studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Seven-Year, Single-Centre Experience of the Long-Term Outcomes of Bovine Ureter Grafts Used as Novel Conduits for Haemodialysis Fistulas

Purpose: To report the long-term outcomes of bovine ureter grafts as novel conduits for haemodialysis fistulas. Materials and Methods: Thirty-five patients underwent placement of a total of 40 SynerGraft 100 (SG100; CryoLife Europa{sup Registered-Sign}, Guildford, UK) bovine ureter grafts between April 2002 and February 2009. Prospective data were collected on all patients, including active surveillance with blood flow studies and 6-monthly duplex ultrasound studies. Main outcome measures were primary and secondary patency rates. Results: Mean follow-up time was 97 weeks (range 4-270). Thirteen patients died from unrelated causes during the study period; 12 of these patients had a functioning graft at the time of death. Five patients underwent transplantation, and all had a functioning graft at transplantation. Twelve patients had a functioning graft at the end of the study period. One hundred and ten stenoses were detected, and 97 venoplasty procedures were performed. Of the stenoses, 41.8% were located at the venous anastomosis, 12.7% within the graft, 17.3% in the outflow veins, and 28.1% in central veins. No arterial stenoses were detected. Primary patency rates were 53% at 6 months and 14% at 1 year. Secondary patency rates were 81% at 6 months, 75% at 1 year, and 56% at 2 years. Conclusions: Active surveillance and intervention was able to achieve satisfactory long-term secondary patency for these novel conduits compared with those made of PTFE seen in other studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of the roles of gas-phase CF{sub 2} molecules and F atoms during fluorocarbon plasma processing of Si and ZrO{sub 2} substrates

The molecular-level chemistry involved in the processing of silicon and zirconia substrates by inductively coupled fluorocarbon (FC) plasmas produced from CF{sub 4} and C{sub 2}F{sub 6} precursors has been explored. The roles of gas-phase excited, neutral, and ionic species, especially CF{sub 2} and F, were examined as they contribute to FC film formation and substrate etching. The surface reactivity of CF{sub 2} radicals in C{sub 2}F{sub 6} plasmas has a dependence on substrate material and plasma system, as measured by our imaging of radicals interacting with surfaces (IRIS) technique. Relative concentrations of excited state species are also dependent upon substrate type. Moreover, differences in the nature and concentrations of gas-phase species in CF{sub 4} and C{sub 2}F{sub 6} plasmas contribute to markedly different surface compositions for FC films deposited on substrates as revealed from x-ray photoelectron spectroscopic analysis. These data have led to the development of a scheme that illustrates the mechanisms of film formation and destruction in these FC/substrate systems with respect to CF{sub 2} and F gas-phase species and also Si and ZrO{sub 2} substrates.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low temperature fluorination of Sr{sub 3}Fe{sub 2}O{sub 7-x} with polyvinylidine fluoride: An X-ray powder diffraction and Moessbauer spectroscopy study

Fluorination of the Ruddlesden Popper phase, Sr{sub 3}Fe{sub 2}O{sub 7-x} by heat treatment with polyvinylidine fluoride (PVDF) gives a range of novel oxide fluoride compounds. Fluorination with 1 mol equivalent PVDF leads to a filling of the normal Ruddlesden Popper structure anion sites and a material of composition Sr{sub 3}Fe{sub 2}O{sub 5+x}F{sub 2-x} (x Almost-Equal-To 0.28(4)) which contains both Fe{sup 4+} and Fe{sup 3+}. Increasing the amount of PVDF to 2 mol equivalent leads to an increase in anion content due to filling of half the interstitial sites within the structure, with iron being completely reduced to Fe{sup 3+} leading to a composition Sr{sub 3}Fe{sub 2}O{sub 4}F{sub 4}. An increase in the amount of PVDF to Almost-Equal-To 3 mol equivalent leads to a further increase in unit cell volume, attributed to complete filling of the interstitial sites and a composition Sr{sub 3}Fe{sub 2}O{sub 3}F{sub 6}. {sup 57}Fe Moessbauer spectra in the temperature range 10-300 K demonstrated the complexity of the magnetic interactions in each of the three phases which reflect different local compositions of oxygen and fluorine around the iron ions thus influencing the superexchange pathways. - Graphical abstract: Low temperature (375 Degree-Sign C) fluorination of Sr{sub 3}Fe{sub 2}O{sub 7-x} with poly(vinylidene fluoride) leads to the production of three new Ruddlesden Popper oxide fluorides with progressive filling of the anion sites within the structure. Highlights: Black-Right-Pointing-Pointer The fluorination of Sr{sub 3}Fe{sub 2}O{sub 7-x} using PVDF. Black-Right-Pointing-Pointer The control of the fluorine content with amount of PVDF used. Black-Right-Pointing-Pointer The synthesis of three new Fe based oxide fluorides. Black-Right-Pointing-Pointer The identification of the structures of these oxide fluorides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Double-Layered PTFE-Covered Nitinol Stents: Experience in 32 Patients with Malignant Esophageal Strictures

We evaluated the effectiveness of a double-layered polytetrafluoroethylene (PTFE)-covered nitinol stent in the palliative treatment of malignant esophageal strictures. A double-layered PTFE-covered nitinol stent was designed to reduce the propensity to migration of conventional covered stent. The stent consists of an inner PTFE-covered stent and an outer uncovered nitinol stent tube. With fluoroscopic guidance, the stent was placed in 32 consecutive patients with malignant esophageal strictures. During the follow-up period, the technical and clinical success rates, complications, and cumulative patient survival and stent patency were evaluated. Stent placement was technically successful in all patients, and no procedural complications occurred. After stent placement, the symptoms of 30 patients (94%) showed improvement. During the mean follow-up of 103 days (range, 9-348 days), 11 (34%) of 32 patients developed recurrent symptoms due to tumor overgrowth in five patients (16%), tumor ingrowth owing to detachment of the covering material (PTFE) apart from the stent wire in 3 (9%), mucosal hyperplasia in 2 (6%), and stent migration in 1 (3%). Ten of these 11 patients were treated by means of placing a second covered stent. Thirty patients died, 29 as a result of disease progression and 1 from aspiration pneumonia. The median survival period was 92 days. The median period of primary stent patency was 190 days. The double-layered PTFE-covered nitinol stent seems to be effective for the palliative treatment of malignant esophageal strictures. We believe that the double-layer configuration of this stent can contribute to decreasing the stent's migration rate.

36 MATERIALS SCIENCE↗

Electronic Structure and Gas-Phase Behaviour of the Heaviest Elements

Electronic structures and gas-phase adsorption behaviour of the heaviest elements 112, 113 and 114 and of their lighter homologs Hg, Tl and Pb is studied on the basis of ab initio Dirac-Coulomb atomic and four-component Density Functional Theory molecular and cluster calculations. The heaviest elements were shown to have low adsorption enthalpies on Teflon and should, therefore, be well transported through Teflon capillaries from the target chamber to the chemistry set up. Adsorption enthalpies of these elements on the Au(111) surface are predicted as -44.5 kJ/mol, -158.6 kJ/mol and -68.5 kJ/mol, respectively, giving the following sequence in the adsorption temperatures 113>114>112.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self-masking controlled by metallic seed layer during glass dry-etching for optically scattering surfaces

During reactive ion etching in a high density Ar/CF{sub 4} plasma, nonvolatile halogen compounds are generated on the glass surface and act as statistically distributed micromasks. As a consequence surface roughness occurs, which can be used as additional surface functionality in certain classes of applications, where defined optical scattering is desired. The glass etch process described in this contribution enables user-defined scattering characteristics. The deposition of a thin metallic layer of Cu on top of the samples before dry-etching provides an additional seed for the production of micromasks, resulting in higher reproducibility. By varying the etch parameters a multitude of different surface morphologies can be realized both on borosilicate glasses and on fused silica.

36 MATERIALS SCIENCE↗

Effect of substrate roughness on the apparent surface free energy of sputter deposited superhydrophobic polytetrafluoroethylene coatings: A comparison of experimental data with different theoretical models

We have studied the effect of substrate roughness on the wettability and the apparent surface free energy (SFE) of sputter deposited polytetrafluoroethylene (PTFE) coatings deposited on untreated glass (average roughness, R{sub a}=2.0 nm), plasma etched glass (R{sub a}=7.4 nm), and sandblasted glass (R{sub a}=4500 nm) substrates. The wettability of the PTFE coatings deposited on substrates with varying roughnesses was evaluated by measuring the apparent contact angle (CA) using a series of probe liquids from nonpolar aprotic to polar protic. The wettability measurements indicate that an apparent water CA of 152 deg. with a sliding angle of 8 deg. was achieved for PTFE coatings deposited on a substrate with R{sub a}=4500 nm. The superhydrophobicity observed in these coatings is attributed to the presence of dual scale roughness, densely packed microstructure and the presence of CF{sub 3} groups. Unlike the bulk PTFE which is mainly dispersive, the sputter deposited PTFE coatings are expected to have some degree of polar component due to the plasma treatment. In order to calculate the dispersive SFE of PTFE coatings, we have used the Girifalco-Good-Fowkes (GGF) method and validated it with the Zisman model. Furthermore, the Owens-Wendt model has been used to calculate the dispersive and the polar components of the apparent SFE of the PTFE coatings. These results are further corroborated using the Fowkes method. Finally, an ''equation of state'' theory proposed by Neumann has been used to calculate the apparent SFE values of the PTFE coatings. The results indicate that the apparent SFE values of the PTFE coatings obtained from the Owens-Wendt and the Fowkes methods are comparable to those obtained from the Neumann's method. The analyses further demonstrate that the GGF and the Zisman methods underestimate the apparent SFE values of the sputter deposited PTFE coatings.

36 MATERIALS SCIENCE↗

Structure and magnetic properties of the cubic oxide fluoride BaFeO{sub 2}F

Fluorination of the parent oxide, BaFeO{sub 3-{delta}}, with polyvinylidine fluoride gives rise to a cubic compound with a=4.0603(4) A at 298 K. {sup 57}Fe Moessbauer spectra confirmed that all the iron is present as Fe{sup 3+}. Neutron diffraction data showed complete occupancy of the anion sites, indicating a composition BaFeO{sub 2}F, with a large displacement of the iron off-site. The magnetic ordering temperature was determined as T{sub N}=645{+-}5 K. Neutron diffraction data at 4.2 K established G-type antiferromagnetism with a magnetic moment per Fe{sup 3+} ion of 3.95 {mu}{sub B}. However, magnetisation measurements indicated the presence of a weak ferromagnetic moment that is assigned to the canting of the antiferromagnetic structure. {sup 57}Fe Moessbauer spectra in the temperature range 10-300 K were fitted with a model of fluoride ion distribution that retains charge neutrality of the perovskite unit cell. - Graphical abstract: The cubic oxide fluoride of composition BaFeO{sub 2}F has been synthesised and characterised. Highlights: > Fluorination of BaFeO{sub 3-{delta}} with polyvinylidene fluoride gives a cubic oxide fluoride of composition BaFeO{sub 2}F. > BaFeO{sub 2}F adopts a canted antiferromagnetic structure and is different from the related phase of composition SrFeO{sub 2}F. > A model of fluoride ion distribution about iron in BaFeO{sub 2}F has been explored.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of PTFE Stent Grafts for Hemodialysis-related Central Venous Occlusions: Intermediate-Term Results

Purpose: To assess the safety and effectiveness of a polytetrafluoroethylene (PTFE) encapsulated nitinol stents (Bard Peripheral Vascular, Tempe, AZ) for treatment of hemodialysis-related central venous occlusions. Materials and Methods: Study design was a single-center nonrandomized retrospective cohort of patients from May 2004 to August 2009 for a total of 64 months. There were 14 patients (mean age 60 years, range 50-83 years; 13 male, 1 female). All patients had autogenous fistulas. All 14 patients had central venous occlusions and presented with clinical symptoms of the following: extremity swelling (14%, 2 of 14), extremity and face swelling (72%, 10 of 14), and face swelling/edema (14%, 2 of 14). There was evidence of access dysfunction with decreased access flow in 36% (5 of 14) patients. There were prior interventions or previous line placement at the site of the central venous lesion in all 14 patients. Results were assessed by recurrence of clinical symptoms and function of the access circuit (National Kidney Foundation recommended criteria). Results: Sixteen consecutive straight stent grafts were implanted in 14 patients. Average treated lesion length was 5.0 cm (range, 0.9-7 cm). All 14 patients had complete central venous occlusion (100% stenosis). The central venous occlusions were located as follows: right subclavian and brachiocephalic vein (21%, 3 of 14), right brachiocephalic vein (36%, 5 of 14), left brachiocephalic vein (36%, 5 of 14), and bilateral brachiocephalic vein (7%, 1 of 14). A total of 16 PTFE stent grafts were placed. Ten- or 12-mm-diameter PTFE stent grafts were placed. The average stent length was 6.1 cm (range, 4-8 cm). Technical (deployment), anatomic (<30% residual stenosis), clinical (resolution of symptoms), and hemodynamic (resolution of access dysfunction) success were 100%. At 3, 6, and 9 months, primary patency of the treated area and access circuit were 100% (14 of 14). Conclusions: This PTFE encapsulated stent graft demonstrates encouraging intermediate-term patency results for central vein occlusions. Further prospective studies with long-term assessment and larger patient populations will be required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pull-Through Technique for Recanalization of Occluded Portosystemic Shunts (TIPS): Technical Note and Review of the Literature

Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction is an important problem after creation of shunts. Most commonly, TIPS recanalization is performed via the jugular vein approach. Occasionally it is difficult to cross the occlusion. We describe a hybrid technique for TIPS revision via a direct transhepatic access combined with a transjugular approach. In two cases, bare metal stents or polytetrafluoroethylene (PTFE)-covered stent grafts had been placed in TIPS tract previously, and they were completely obstructed. The tracts were inaccessible via the jugular vein route alone. In each case, after fluoroscopy or computed tomography-guided transhepatic puncture of the stented segment of the TIPS, a wire was threaded through the shunt and snared into the right jugular vein. The TIPS was revised by balloon angioplasty and additional in-stent placement of PTFE-covered stent grafts. The patients were discharged without any complications. Doppler sonography 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites. We conclude that this technique is feasible and useful, even in patients with previous PTFE-covered stent graft placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lateral propagation of MeV electrons generated by femtosecond laser irradiation

The propagation of MeV electrons generated by intense (approx =10{sup 20} W/cm{sup 2}) femtosecond laser irradiation, in the lateral direction perpendicular to the incident laser beam, was studied using targets consisting of irradiated metal wires and neighboring spectator wires embedded in electrically conductive (aluminum) or resistive (Teflon) substrates. The K shell spectra in the energy range 40-60 keV from wires of Gd, Dy, Hf, and W were recorded by a transmission crystal spectrometer. The spectra were produced by 1s electron ionization in the irradiated wire and by energetic electron propagation through the substrate material to the spectator wire of a different metal. The electron range and energy were determined from the relative K shell emissions from the irradiated and spectator wires separated by varying substrate lateral distances of up to 1 mm. It was found that electron propagation through Teflon was inhibited, compared to aluminum, implying a relatively weak return current and incomplete space-charge neutralization. The energetic electron propagation in the direction parallel to the electric field of the laser beam was larger than perpendicular to the electric field. Energetic electron production was lower when directly irradiating aluminum or Teflon compared to irradiating the heavy metal wires. These experiments are important for the determination of the energetic electron production mechanism and for understanding lateral electron propagation that can be detrimental to fast-ignition fusion and hard x-ray backlighter radiography.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of energy harvesting performance of electrostrictive polymer and carbon-filled terpolymer composites

Recent trends in energy conversion mechanisms have demonstrated the abilities of electrostrictive polymers for converting mechanical vibrations into electricity. In particular, such materials present advantageous features such as high productivity, high flexibility, and processability. Hence, the application of these materials for energy harvesting purposes has been of significant interest over the last few years. The purpose of this paper consists in evaluating the energy scavenging abilities of electrostrictive terpolymer composite filled with 1 vol % carbon black poly(vinylidene fluoride-trifluoroethylene-chlorofluoroethylene). For fair comparison, a new figure of merit taking into account the intrinsic parameters of the material is introduced. This figure of merit equals the squared product of the electric field-related electrostrictive coefficient by the Young modulus, divided by the permittivity, relating the electric energy density per cycle per squared strain magnitude and squared bias electric field. Based on this criterion, it is demonstrated that the carbon-filled terpolymer outperforms other investigated compositions, exhibiting a figure of merit as high as 30 mJ cm{sup -3} (m/m){sup -2} (V/{mu}m){sup -2} cycle{sup -1}, which is 2000 times higher than pure polyurethane. In addition, the comparison of the figure of merit with experimental maximal harvested powers shows that such a criterion allows a very accurate prediction of the energy scavenging performance of electrostrictive composites.

36 MATERIALS SCIENCE↗

Dielectric Properties of PVDF/PZT

Poly(vinylidene fluoride)/ lead zirconate titanate nanocomposite (PVDF/PZT-NPs) were successfully prepared by mixing fine Pb(Zr{sub 0.52}, Ti{sub 0.48})O{sub 3} nanoparticles (PZT-NPs) into a PVDF solution under ultrasonication. The mixture was spin coated onto glass substrate and then annealed at 80 deg. C. X-ray diffraction (XRD), transmission electron microscopy (TEM), and scanning electron microscopy (SEM) were used to characterize the structure and properties of the obtained thin-film nanocomposites. The nanocomposites exhibited good dielectric stability over a wide frequency range.

77 NANOSCIENCE AND NANOTECHNOLOGY↗