Search NASA⌕ Search

SEARCH · Search NASA

Results for “OSMIUM 192”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A = 192

Experimental structure and decay data for all nuclei with mass A=192 (Ta, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb, Bi, Po, At) have been evaluated. This evaluation, covering data received by 15 June 2012, supersedes the 1998 evaluation by C. M. Baglin (Nuclear Data Sheets84, 717 (1998), literature cutoff August 1998) and the subsequent inclusion in the ENSDF database of the new nuclide {sup 192}At (C. M. Baglin, literature cutoff 16 May 2006). It also incorporates the current evaluation of superdeformed-band information by B. Singh. Since the last publication, {sup 192}Ta, {sup 192}W and {sup 192}At have been observed, and an isomeric state has been identified in {sup 192}Re. The {epsilon} decay of {sup 192}Au has been studied using a multidetector array resulting in an extensively revised level scheme for {sup 192}Pt.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photodisintegration of the isotopes {sup 186,188,189,190,192}Os: Similarities and distinctions

In addition to the results obtained earlier for the isotopes {sup 188,189}Os, experimental data on the photodisintegration of the isotopes {sup 186,190,192}Os are analyzed on the basis of specially introduced objective criteria of reliability of data on the cross sections for partial photoneutron reactions. It is found that the (γ, 1n), (γ, 2n), and (γ, 3n) cross sections for each isotope satisfy differently or, on the contrary, do not satisfy the data-reliability criteria. In many cases, the multiplicity transition functions specified as the ratios F{sub i} = σ(γ, in)/σ(γ, xn) of the cross sections for the (γ, in) partial reactions to the neutron-yield reaction cross section σ(γ, xn) = σ(γ, 1n) + 2σ(γ, 2n) + 3σ(γ, 3n) +... have values that are physically unreliable by definition. It is shown that ambiguities in the dependence of significant systematic uncertainties in experimentally determined neutron multiplicities on the measured kinetic energies is the reason for this. The dependence of these uncertainties on the energy spectra of neutrons is analyzed. For the isotopes {sup 186,190,192}Os, new evaluated data satisfying the data-reliability criteria are obtained for the cross sections for partial and total photoneutron reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for rare nuclear decays with HPGe detectors at the STELLA facility of the LNGS

Results on the search for rare nuclear decays with the ultra low background facility STELLA at the LNGS using gamma ray spectrometry are presented. In particular, the best T{sub 1/2} limits were obtained for double beta processes in {sup 96}Ru and {sup 104}Ru. Several isotopes, which potentially decay through different 2β channels, including also possible resonant double electron captures, were investigated for the first time ({sup 156}Dy, {sup 158}Dy, {sup 184}Os, {sup 192}Os, {sup 190}Pt, {sup 198}Pt). Search for resonant absorption of solar {sup 7}Li axions in a LiF crystal gave the best limit for the mass of {sup 7}Li axions (< 8.6 keV). Rare alpha decay of {sup 190}Pt to the first excited level of {sup 186}Os(E{sub exc} = 137.2keV) was observed for the first time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modern status of photonuclear data

The reliability of experimental cross sections obtained for (γ, 1n), (γ, 2n), and (γ, 3n) partial photoneutron reactions using beams of quasimonoenergetic annihilation photons and bremsstrahlung is analyzed by employing data for a large number of medium-heavy and heavy nuclei, including those of {sup 63,65}Cu, {sup 80}Se, {sup 90,91,94}Zr, {sup 115}In, {sup 112−124}Sn, {sup 133}Cs, {sup 138}Ba, {sup 159}Tb, {sup 181}Ta, {sup 186−192}Os, {sup 197}Au, {sup 208}Pb, and {sup 209}Bi. The ratios of the cross sections of definite partial reactions to the cross section of the neutron-yield reaction, F{sub i} = σ(γ, in)/σ(γ, xn), are used as criteria of experimental-data reliability. By definition, positive values of these ratios should not exceed the upper limits of 1.00, 0.50, 0.33,... for i = 1, 2, 3,..., respectively. For many nuclei, unreliable values of the above ratios were found to correlate clearly in various photon-energy regions F{sub i} with physically forbidden negative values of cross sections of partial reactions. On this basis, one can conclude that correspondent experimental data are unreliable. Significant systematic uncertainties of the methods used to determine photoneutron multiplicity are shown to be the main reason for this. New partial-reaction cross sections that satisfy the above data-reliability criteria were evaluated within an experimental–theoretical method [σ{sup eval}(γ, in) = F{sub i}{sup theor} (γ, in) × σ{sup expt}(γ, xn)] by employing the ratios F{sub i}{sup theor} (γ, in) calculated on the basis of a combined photonuclear-reaction model. It was obtained that cross sections evaluated in this way deviate substantially from the results of many experiments performed via neutron-multiplicity sorting, but, at the same time, agree with the results of alternative activation experiments. Prospects of employing methods that would provide, without recourse to photoneutron-multiplicity sorting, reliable data on cross sections of partial photoneutron reactions are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-523: Investigation of Various MR-Compatible Shielding Materials for Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer Treatment

Purpose: To evaluate various shielding materials such as Gold (Au), Osmium (Os), Tantalum (Ta), and Tungsten (W) based alloys for use with a novel intensity modulation capable direction modulated brachytherapy (DMBT) tandem applicator for image guided cervical cancer HDR brachytherapy. Methods: The novel MRI-compatible DMBT tandem, made from nonmagnetic tungsten-alloy rod with diameter of 5.4 mm, has 6 symmetric peripheral holes of 1.3 mm diameter with 2.05 mm distance from the center for a high degree intensity modulation capacity. The 0.3 mm thickness of bio-compatible plastic tubing wraps the tandem. MCNPX was used for Monte Carlo simulations of the shields and the mHDR Ir-192 V2 source. MC-generated 3D dose matrices of different shielding materials of Au, Os, Ta, and W with 1 mm3 resolution were imported into an in-house-coded inverse optimization planning system to evaluate 19 clinical patient plans. Prescription dose was 15Gy. All plans were normalized to receive the same HRCTV D90. Results: In general, the plan qualities for various shielding materials were similar. The OAR D2cc for bladder was very similar for Au, Os, and Ta with 11.64±2.30Gy. For W, it was very close 11.65±2.30Gy. The sigmoid D2cc was 9.82±2.46Gy for Au and Os while it was 9.84±2.48Gy for Ta and W. The rectum D2cc was 7.44±3.06Gy for Au, 7.43±3.07Gy for Os, 7.48±3.05Gy for Ta, and 7.47±3.05Gy for W. The HRCTV D98 and V100 were very close with 16.37±1.87 Gy and 97.37±1.93 Gy, on average, respectively. Conclusion: Various MRI-compatible shielding alloys were investigated for the DMBT tandem applicator. The clinical plan qualities were not significantly different among these various alloys, however. Therefore, the candidate metals (or in combination) can be used to select best alloys for MRI image guided cervical cancer brachytherapy using the novel DMBT applicator that is capable of unprecedented level of intensity modulation.

60 APPLIED LIFE SCIENCES↗