Search NASA⌕ Search

SEARCH · Search NASA

Results for “OT Environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Are System Baselines within OT Environments Feasible?

Critical infrastructure stakeholders need to baseline their systems to understand expected protocol communications.Baseline behaviors may vary based on operational context.Expected operations during a maintenance window, for example, may be different from normal operations.Furthermore, constructing system baselines for Industrial Control Systems (ICS) is difficult and time-consuming.ICS processes generate artifacts expressed across heterogeneous data sources such as network and device logs. There needs to be a corpus of data in order to develop and compare methods that evaluate the feasibility, performance, and generality of approaches to construct baselines for ICS events. Standalone repositories of network packet captures are insufficient to develop methods to classify or recognize operational events expressed across multiple data sources. Moreover, static data corpora do not enable researchers to compare the impact of changing the underlying system for which a baseline is being constructed and this limits the ability to evaluate the performance of system baselines given system changes (e.g. patches, configuration, maintenance events). In order to address these limitations within the community, this talk intends to promote discussion about the state of the practice of constructing baselines. In this manner, we can continue to understand requirements within industry that are not being met by current approaches to baseline construction. This talk builds on two previous talks on the topic of system baselines for OT environments. First, Weaver co-presented at the RSA Conference ICS Sandbox with Dan Gunter. The talk confirmed the need within industry to construct baselines across multiple types of data sources relative to the semantics of specific business processes. Second, Weaver presented at IEEE Security and Privacy Workshop on Language-Theoretic Security.

02 PETROLEUM↗

Cyber-physical Architecture For Automated Responses (cyphar) In Adversarial Ot Environments

The ability to react to a malicious attack starts with high fidelity recognition, and with that, an agile response to the attack. The current operational technology (OT) systems for a critical infrastructure may include an intrusion detection system (IDS), but the ability to adapt to an intrusion is a human initiated response. Orchestrators, which are coming of age in the financial sector and allow for levels of automated response, are not prevalent in the OT space. To evolve to such responses in the OT space, a tradeoff analysis is first needed, The tradeoff analysis, which evaluates the mitigation benefits of responses versus the physical affects that result, inform an automated response decision. The intent of this paper is to provide a formulation of a tradeoff analysis and its use in advancing automated, agile responses.

Rieger, CraigG.↗

CyOTE ASSET OWNER ENGAGEMENT – SIDE CHANNEL POWER ANALYSIS PROTOTYPE

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through the Cybersecurity for the Operational Technology Environment (CyOTE) Program, worked with energy sector asset owners and operators (AOOs), partners, and Idaho National Laboratory (INL) to develop capabilities for AOOs to independently identify adversarial tactics, techniques, and procedures (TTPs) within their operational technology (OT) environments. The CyOTE methodology seeks to identify adversarial techniques within an AOO OT environment that could result in physical disruptions to energy flow or damage to equipment. CyOTE provides a general roadmap for AOOs, starting from a triggering event, or the point in time and space they perceive an anomalous event or condition meriting investigation, and culminating when the AOO has sufficient confidence to make a business risk decision on the appropriate resolution. This paper outlines the results of one such engagement with the New York Power Authority (NYPA), where the CyOTE program partnered with an AOO to develop a design specification for a power side channel detector to identify anomalous changes to device load. It describes the goal of developing this capability, the development process, the challenges the technical teams faced and the future steps an AOO will need to take to install and use this detector in its OT environment.

99 GENERAL AND MISCELLANEOUS↗

Towards 5G-Enabled Operational Technology for Process Monitoring and Network Slicing

Cyber-Physical Systems (CPS) are deployed to monitor physical processes in critical cyber-enabled services like power generation. However, CPS ecosystems are typically designed without robust security. While it is important to ensure optimal performance of the Operational Technology (OT) environments, security cannot be overlooked. To modernize traditional OT services, 5G technology is being integrated. 5G technology offers low latency and high availability, making it a suitable infrastructure for managing and monitoring physical processes. How-ever, integrating 5G mechanisms into large-scale OT networks introduces new implementation and performance challenges. Therefore, this paper presents a 5G-enabled CPS architecture (5G-CPS) that describes the necessary components, services, and communication protocols and conducts feasibility study to integrate 5G technology in industrial control system networks to understand the performance merits. The 5G-CPS architecture aims to minimize implementation and operational challenges associated with integrating 5G technology into constrained OT.

Aguayo, Jared M.↗

Identifying Adversarial Cyber-Activity in Operational Technology Environments Using Bayesian Networks

Critical infrastructure and other operational technology (OT) environments face increasing cybersecurity risks from adversarial behavior. This paper describes the development of a risk model using a Bayesian network to enhance the comprehension of observable cyber events caused by malicious activity in OT environments. The core of the Bayesian network is a process model that describes the stages of adversary behavior. The remainder of the model is based on the MITRE ATT&CK® for Industrial Control Systems (ICS) taxonomy, which includes tactics and techniques that may be used by the adversary. The observables provide evidence for adversary behavior through the intermediary technique and tactic nodes. One challenge in constructing this model is a lack of open-source data from cyber-attacks on OT systems. This paper discusses learning from limited data, the elicitation of expert opinion to construct the conditional probability tables when data is scarce, and the refinement of the most difficult conditional probabilities tables using several forms of sensitivity analyses. Finally, the Bayesian network is demonstrated using two historical case studies: the DarkSide ransomware attack on the Colonial Pipeline and the destructive cyberattack targeting the ThyssenKrupp blast furnace. Index Terms—Cybersecurity, industrial control systems, operational technology

97 - MATHEMATICS AND COMPUTING↗

I Can't Patch My OT Systems! A Look at CISA's KEVC Workarounds & Mitigations for OT

We examine the state of publicly available information about known exploitable vulnerabilities applicable to operational technology (OT) environments. Specifically, we analyze the Known Exploitable Vulnerabilities Catalog (KEVC) maintained by the US Department of Homeland Security Cybersecurity and Infrastructure Security Agency (CISA) to assess whether currently available data is sufficient for effective and reliable remediation in OT settings. Our team analyzed all KEVC entries through July 2025 to determine the extent to which OT environments can rely on existing remediation recommendations. We found that although most entries in the KEVC could affect OT environments, only 13% include vendor workarounds or mitigations as alternatives to patching. This paper also examines the feasibility of developing such alternatives based on vulnerability and exploit characteristics, and we present early evidence of success with this approach.

97 MATHEMATICS AND COMPUTING↗

HP in Cybersecurity: CyOTE

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through the Cybersecurity for the Operational Technology Environment (CyOTE) Program, worked with energy sector asset owners and operators (AOOs), partners, and Idaho National Laboratory (INL) to develop capabilities for AOOs to independently detect adversarial tactics, techniques, and procedures (TTPs) within their operational technology (OT) environments. Unlike the approach taken with commercial security solutions, CyOTE seeks to tie anomalies in cyber operations to a cyber-attack. By stringing together multiple techniques in the OT environment, AOOs can identify attack campaigns with ever decreasing impacts. The CyOTE methodology applies fundamental concepts of perception and comprehension to a universe of knowns and unknowns increasingly disaggregated into observables, anomalies, and triggering events. MITRE’s ATT&CK® Framework for Industrial Control Systems (ICS) is used as a common lexicon to identify a set of triggering events related to three Use Cases – Alarm Logs, Human-Machine Interface (HMI), and Remote Logins – which together account for 87 percent of the techniques commonly used by adversaries. The CyOTE methodology is also appropriate for OT-related anomalies perceived outside the three Use Cases, such as through the energy system itself.

99 GENERAL AND MISCELLANEOUS↗

Automation of Vulnerability and Patch Management: Information Extraction, Association, and Optimization

Vulnerability and patch management is an integral part of a robust cybersecurity program, yet it grows increasingly complex due to the sheer amount of data that must be analyzed. Particularly in Operational Technology (OT) environments, analysis must be done manually because of the lack of automated solutions. Additionally, there are many steps in this process, from the initial discovery of the vulnerability to the implementation of its remediation, and each step in the process requires different data in order to be performed effectively. In this work, we provide approaches and strategies to assist operators in industrial or OT environments throughout the vulnerability management cycle. Security advisories provide key information about mitigation strategies, or actions that can be taken when a patch is unavailable or cannot be installed. Details of these strategies are not shared in public vulnerability databases and must be found manually. We approach this problem by designing a solution to automatically identify that information within vendor security advisories and retrieve it for operator use. We start with an approach that requires domain-specific knowledge of certain frequently-seen reference websites. Next, an approach that can work on an arbitrary website but relies on certain keywords. Finally, an approach that uses Natural Language Processing (NLP) methods and does not require specific knowledge or keywords. Each of these approaches is more general than its predecessor; we demonstrate high accuracy for all approaches Advisories also often contain details of affected products in non-standard or natural language formats. While this information can be easily understood when read by an operator, the non-standard format acts as a barrier to effective automation. We provide an approach for the first step in this process: identifying vendors in security advisories and mapping them to a standard framework for representing digital assets and software products. We evaluate five established string similarity algorithms, plus one of our own design that combines string similarity and information theory, on the task of mapping vendors to their corresponding entries in the Common Platform Enumeration (CPE) repository. Our results show that our proposed metric outperforms all others. Due to the constraints on time, finances, and personnel for organizations, Large Language Models (LLMs) may seem like attractive opportunities for security operators to speed up information gathering; however, it is still not clear whether LLMs can handle vulnerability management tasks well. To answer this question, we perform an empirical study of LLMs’ ability to provide consistent, accurate information about vulnerabilities in order to guide organizations in their adoption of LLMs. We observe poor performance for all models tested, suggesting that these models are not well-suited to the consistent retrieval of accurate vulnerability information. Finally, once vulnerabilities have been identified and any additional information has been obtained, operators must decide which remediation actions to implement based on their available resources. This already-complex problem becomes even more so when we consider that a vulnerability may have multiple avenues for remediation. We formulate this scenario as two knapsack problems and provide solutions, which we then compare against several existing strategies for vulnerability prioritization seen in real operational environments.

McClanahan, Kylie↗

Precursor Analysis Report: Doppelpaymer Ransomware Attack on Petroleos Mexicanos (PEMEX) 2019

The DoppelPaymer Ransomware Attack on Petroleos Mexicanos (PEMEX) 2019 Precursor Analysis Report leverages publicly available information about the PEMEX cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. The 2019 DoppelPaymer ransomware attack on PEMEX, Mexico’s nationalized petroleum corporation, highlights a unique threat that ransomware and cybercriminal extortion poses to Operational Technology (OT) environments in critical infrastructure. The incident began with an employee downloading commodity malware that allowed adversaries to gain initial access to PEMEX’s enterprise environment. After conducting privilege escalation, tool ingress, and data exfiltration, the adversaries deployed DoppelPaymer ransomware throughout the PEMEX enterprise environment, resulting in the company having to take dozens of systems offline for at least several days. Although PEMEX stated that their operations were not affected, the data exfiltrated from PEMEX was made available for download on DoppelPaymer’s leak site, as well as on other illicit criminal forums. This stolen data included not only company information, but also sensitive OT-specific configuration data. This incident showcases how cybercriminal exfiltration and posting of sensitive OT architecture documentation can pose security concerns for the targeted organization for years due to the long lifespan of OT assets and architectures. Researchers and analysts identified 18 unique techniques utilized during the attack with a total of 190 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fifteen of the identified techniques used during the DoppelPaymer ransomware attack were precursors to the triggering event. Analysis identified 163 observables associated with these precursor techniques, 34 of which were assessed to have an increased likelihood of being perceived in the 60 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Cybersecurity for the Operational Technology Environment (CyOTE) (Final Technical Report)

Electric grids have historically been susceptible to both physical attacks and environmental hazards but the implementation of smart grids, remote management, and self-healing networks, has now made the grid vulnerable to cyber attacks. To address risks introduced by routable connectivity, utilities must establish dynamic solutions to identify, protect, detect, respond to, and recover from cyber security threats and vulnerabilities. In response to the evolving threat landscape U.S. Department of Energy-Office of Cybersecurity, Energy Security, and Emergency Response (DOE CESER) initiated the Cybersecurity for the OT Environment (CyOTE) pilot program, a U.S. Department of Energy (DOE) effort designed to leverage U.S. intelligence capabilities to prevent, detect, or mitigate a cyber attack on utility operational technology (OT) networks. As part of the CyOTE pilot, The Southern Company (Southern Company or Southern) researched, evaluated and deployed emerging Commercial off the Shelf (COTS) technologies and cyber security monitoring architectures to provide previously unrealized network visibility and situational awareness through deep packet inspection and data analytics. This Final Scientific/Technical Report documents the objectives, methodology, lessons learned, and results of Southern Company’s participation in the CyOTE pilot from December 2018 to September 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

5G integrated edge computing platform for efficient component monitoring in coal-fired power plants

This project developed a cutting-edge 5G-integrated edge computing framework to enhance operational efficiency and reliability in coal-fired power plants through real-time component monitoring and anomaly detection. The initiative focused on leveraging distributed machine learning, federated learning, and 5G-based dynamic network slicing to support scalable, fault-tolerant monitoring environments to meet the operational requirements in industrial control systems. With a Distributed Edge Computing Service (DECS) orchestration, this project enabled federated learning at edge for condition monitoring and introduced adaptive client selection strategies to minimize communication overhead. Scalable distributed training was achieved using the Horovod framework, thus enhancing performance across edge nodes. In the realm of 5G networking, the project designed and deployed reconfigurable, QoS-aware network slicing tailored for operational technology (OT) environments, integrating software-defined networks to bolster cyber-resilience and enabling dynamic slicing for federated learning workloads. A significant milestone was the development of a virtualized ICS environment with 5G core integration—which allowed elastic and fault tolerant distributed training on real-world datasets such as NASA Bearings, Hydraulic Systems, and TEP. To broaden the impact of the project, a TRL-3 virtualized ICS testbed for research and education was designed. This project engaged several graduate and undergraduate students to conduct research on the cutting-edge technology, and it resulted in one PhD dissertation, one MS thesis, and over 14 peer-reviewed publications. With the support of this project students also participated in national cybersecurity competitions to improve their professional development skills.

20 FOSSIL-FUELED POWER PLANTS↗

Precursor Analysis Report: Cyber Attack on Thyssenkrupp Blast Furnace 2014

The Cyber Attack on Thyssenkrupp Blast Furnace 2014 Precursor Analysis Report leverages publicly available information about the Thyssenkrupp Steel Mill cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. In December 2014, the German Government’s Federal Office for Information Security (BSI) released a report detailing a cyber attack on a German steel mill that occurred earlier that year, though exact dates and details of the attack were not revealed. While the report did not specify the name of the company, multiple sources identified the victim as one of Europe’s largest steel manufacturers, Thyssenkrupp AG. Further, Thyssenkrupp announced on 16 May of that year that Europe’s largest blast furnace, “Schwelgern 2,” located at its facility in Duisburg, Germany, would be offline for several weeks for repairs and upgrades, suggesting Schwelgern 2 was likely the target of the attack. The attack began in early 2014, when adversaries infiltrated the victim steel mill’s Information Technology (IT) network via a spearphishing campaign, then worked their way into the Operational Technology (OT) environment, where they executed software that caused denial of service, denial of control, and eventually a loss of control. This led to the blast furnace shutting down without proper safety procedures, resulting in catastrophic physical damage. No lives were lost in the incident, but ThyssenKrupp suffered $4 million in damage to the blast furnace and an additional $6 million in lost revenue. The adversaries required specialized knowledge and expertise in steel production, which enabled them to compromise a variety of internal systems and components across both IT and OT networks. The attack also demonstrated detailed knowledge of the industrial control systems (ICS) and production processes being used. This combination resulted in one of the earliest known publicly reported cybersecurity incidents resulting in physical damage to ICS equipment. Researchers and analysts identified 19 unique techniques (used in a sequence of 20 steps) utilized during the attack with a total of 454 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fifteen of the identified techniques used during the Thyssenkrupp cyber attack were precursors to the triggering event. Analysis identified 369 observables associated with these precursor techniques, 316 of which were assessed to have an increased likelihood of being perceived in the 120 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Evaluating software defined networking solutions to reduce the digital attack surface of nuclear security systems

Most nuclear security systems used today were not designed for today’s threat environment. Systems that were intended to be stand alone are now interconnected. Devices that have a single purpose are built on multi-purpose platforms and communication protocols that, while effective, have no ability to authenticate authorized versus unauthorized commands. These attributes provide an attacker significant ability to affect the system, pivot throughout the interconnected networks, and remain undetected if he/she is able to compromise a single node. Software defined networking (SDN) has been used for years by information technology (IT) cloud service providers to quickly provision or remove servers or other systems to meet changing demand. The same concept has recently been applied to operational technology (OT) systems to enable very fast failover on critical systems that have stringent and deterministic (<5ms) transmit/receive times. By carefully engineering the communication flows through a network using preplanned routes and specific pathways it is possible to achieve deterministic and extremely reliable message delivery even when components fail. This engineering approach to network design has added security benefits including securing the networking control plane, eliminating network scanning and mapping, inhibiting ARP spoofing and host masquerading, eliminating unauthorized network pivoting and enabling greater situational awareness on the network. SDN in OT environments is new but early testing in electrical power and other critical infrastructure has shown it to be a very powerful tool for building reliable networks and reducing the digital attack surface of the network. The authors tested a software defined network switch on a simple physical protection system with components commonly found in nuclear security systems and found improved mitigations to denial of service attacks, lateral movement and network reconnaissance. The paper details the tests and their results.

Cyber security, Nuclear security, software defined↗

Evolution and Trends of Industrial Control System Cyber Incidents since 2017

The industrial control systems (ICSs) that manage our critical infrastructure are increasingly converging with corporate networks and the Internet as technology and businesses prioritize digital connectivity. These connections make them more vulnerable and available to malicious cyber actors who traditionally targeted the companies’ more public-facing information technology (IT) networks. This paper will review select publicly reported cyber incidents to highlight the continued and growing threat to ICS devices and operational technology (OT) environments. It will summarize the incident and when available, will provide information on the cyber actors, the vulnerabilities they exploited, and any publications the U.S. Government (USG) provided in response. Data belonging to the Department of Homeland Security (DHS) will be used to highlight quantitative trends concerning ICS incidents. This paper builds on “History of Industrial Control System Cyber Incidents” (Hemsley & Fisher 2018), a paper that highlighted select noteworthy threats and incidents to ICS systems up to 2017. This paper will similarly review select incidents occurring after the last previously reviewed incident, Triton/HatMan, December 2017, and will note ICS incident trends including IT/OT convergence and advances in cyber-threat actors’ capabilities in observed in the examined incidents.

99 GENERAL AND MISCELLANEOUS↗

Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense (Final)

In the world of ever-advancing technology, Autonomous Systems (AS) find extensive application, bolstering functionalities of critical infrastructures such as nuclear power plants. These systems, however, are increasingly becoming a target for nefarious activities, namely through inference attacks, trojan attacks, and adversarial reprogramming. This paper delves into a comprehensive exploration of machine learning (ML)-driven autonomous control systems within advanced nuclear reactor designs, revealing the vulnerabilities and proposing strategies for defense against potential cyber-attacks. Advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)- based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber-physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems. As global reliance on generation III reactors begins to be critically assessed, the evolution towards advanced reactor systems utilizing digital instrumentation and controls (I&C) becomes not merely preferable, but essential. The integration of semi and fully autonomous control systems (ACS), powered by digital I&C and machine learning (ML)-based digital twinning (DT) technologies, emerges as a potent strategy to mitigate operations and maintenance costs, thereby enhancing the economic feasibility of novel reactor designs. However, with a staggering 500% and 380% increase in cyber-attacks reported against the energy sector by the United States Department of Energy (DoE) and the European Union respectively, a surge in cyber vulnerabilities specifically targeting the nuclear industry has been 2 markedly observed. Notable incidents, such as the W32.Ramnit spyware infiltration at the Gundremmingen nuclear power plant in Germany and the Dtrack spyware intrusion at the Kudankulam nuclear power plant in India, while not directly compromising core industrial control systems (ICS), underscore a compelling necessity to fortify cybersecurity protocols in safeguarding reactor systems against increasingly adept digital adversaries. In light of this, our investigation extends beyond conventional cybersecurity parameters, diving into the intricate web of potential vulnerabilities woven into ML-based DTs and ACS in advanced reactor systems. A crafted cyber-physical testbed and preliminary ACS were devised to act as a mirror, reflecting potential configurations of advanced reactor control designs. Moreover, this study is intertwined with a scrutinization of ML models, developed either through conventional, manually tuned methodologies or via automated means through AutoML, probing into their cyber-risk profiles within operational technology (OT) environments. Expanding on this, two distinct ACS blueprints were forged – one navigating through the corridors of traditional ML and the other traversing the path of AutoML – in an effort to holistically encapsulate the considerations pivotal to ML-based DT control system design. Employing the SANS Institute Industrial Control System (ICS) Kill Chain and the MITRE ATT&CK Tactics, Techniques, and Procedures (TTP) framework, a structured analysis was conducted, launching three targeted attacks against the training dataset, real-time dataset, and ML models, therein dissecting the potential cyber-attack implications against both ML frameworks within an ACS milieu. It is essential to note that three distinct categories of attacks were conducted against both ACS configurations, each encompassing three distinct ML-based DTs, cumulating in a total of 18 varied attacks. This exploration extends into the realms of Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense, unraveling vulnerabilities, and opportunities for fortified defenses against such intrusions, particularly where ML-driven technologies, and by extension, ACS, are deployed. Final recommendations, articulated through a lens of security, safeguard, and implementation considerations, are presented for both traditional and AutoML models, anchoring upon the existing knowledge landscape and ML-based DT modeling for ACS, and are offered as a beacon to guide the nuclear industry through the intricate cybersecurity challenges that lie ahead.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

User Guide to the Facility Cybersecurity Capability Maturity Model (F-C2M2) Assessment

The Facility Cybersecurity Capability Maturity Model (F-C2M2) assessment was designed to help facilities address their unique cybersecurity challenges. Building upon the foundational principles of the U.S. Department of Energy (DOE) Cybersecurity Capability Maturity Model (C2M2), the F-C2M2 was explicitly tailored for federal facilities to help evaluate, benchmark, and enhance the cybersecurity capabilities of both their information technology (IT) and operational technology (OT) environments. This user guide was developed to facilitate a thorough understanding of the tool. Whether users are familiar with the original C2M2 or are new to the maturity model concept, this guide was designed to offer clarity, direction, and support.

97 MATHEMATICS AND COMPUTING↗

Bayesian Attack Model (BAM)

The Bayesian Attack Model (BAM) is an analytical tool designed to enhance the comprehension of adversarial activity in OT environments. BAM leverages both expert cybersecurity insights and historical data to characterize the likelihood of adversarial behavior given anomalous observable events.

99 GENERAL AND MISCELLANEOUS↗