Search NASA⌕ Search

SEARCH · Search NASA

Results for “Occupancy Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

End-Use Savings Shapes Measure Documentation: Demand Control Ventilation

This documentation focuses on a single end-use savings shape measure - Demand Control Ventilation (DCV). DCV can save energy by reducing the rate at which outdoor air (OA) is delivered during periods of less-than-design occupancy. This measure will enable DCV for air loops using applicable HVAC system types (all except dedicated outdoor air systems [DOAS], packaged systems, or that have an energy recovery ventilator [ERV]) and serving applicable space types (all except kitchens, dining areas, patient spaces, mechanical rooms, stairwells and corridors, or high exhaust space types) using model occupancy schedules to control the DCV. The measure is applicable to 72.7% of the stock floor area. As office buildings outside of California in ComStock are modeled using a single, whole-building space type, DCV is not applied to these building types. The DCV measure demonstrates 2.6% total site energy savings (119 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

UPGRADE-E: Understanding Patterns Guiding Residential Adoption and Decisions about Energy Efficiency

This work represents the largest and most comprehensive dataset to-date of responses surveyed from U.S. residents regarding home modifications and energy-related decision-making, including both objective measures describing the occupants and their homes and subjective measures describing the more unpredictable human factors behind residential decision-making. First, to develop the survey, we interviewed 121 individual decision-makers within their households regarding planned or completed projects. We used the insights of these interviews to design a survey that was distributed to 10,000 households across the U.S. The overarching topics approached in the survey include descriptive information about the respondent, their household, their home, home modifications they have made, and the human cognition-based contextual factors involved in home projects and decision-making, such as preferences, motivations, barriers, and information sources. The processed data from the survey was compiled into a dataset entitled UPGRADE-E: Understanding Patterns Guiding Residential Adoption and Decisions about Energy Efficiency and represents the basis for the analyses included in this paper. The dataset represents a rich repository of home energy technology and modification decision-making results, the largest of its kind to-date. The abundance of contextual considerations within this dataset provides a robust resource for continual analysis, with possibilities for considering cross-cuts of data from a variety of perspectives.

Fuentes, Tracy L↗

A-site occupancy effects on structure, ionic conductivity, and thermodynamic stability of KxMgx/2Ti8−x/2O16

Abstract K x Mg x /2 Ti 8− x /2 O 16 (1.54 ≤ x ≤ 2) hollandite samples synthesized using a conventional solid-state route were used to investigate the effect of structure, ionic conductivity, and thermodynamic stability as a function of A-site (K) occupancy. The ionic conductivity, as measured using AC impedance spectroscopy, decreased as the A-site occupancy (and K content) increased. Titanate hollandite, of the form K x Mg x /2 Ti 8− x /2 O 16 , was measured using high-temperature oxide melt solution calorimetry in sodium molybdate (3Na 2 O $$\bullet$$ ∙ 4MoO 3 ) solvent at 804 $$^\circ{\rm C}$$ ∘ C . The enthalpies of formation are strongly exothermic indicating that they are thermodynamically stable relative to their constituent oxides. Previous studies have demonstrated increased stability with an increase in Cs content at fixed A-site occupancy. This work demonstrated an increase in the stability for the K-bearing hollandite samples with an increase in K content and tunnel occupancy. The measured enthalpies of formation (∆ H f,ox ) were in good agreement with density functional theory (DFT) predictions. Graphical abstract

Cassell, Nakeshma S.↗

Direct Measurement of Galaxy Assembly Bias using DESI DR1 Data

We report the first direct measurement of galaxy assembly bias, a critical systematic in cosmology, from the Dark Energy Spectroscopic Instrument (DESI) Bright Galaxy Survey. We introduce a novel, cosmology-independent method to measure the halo occupation distribution (HOD) by combining a state-of-the-art group catalog with weak gravitational lensing. For groups binned by total luminosity, we determine the galaxy occupation number $N_{\rm gal}$ from group-galaxy cross-correlations, while weak lensing constrains the average halo mass $M_h$. Applying this to a volume-limited sample at $z{\in}[0.05,0.2]$, we measure the dependence of HOD, $N_{\rm gal}(M_h)$, on large-scale overdensity $δ_{g}$. Focusing on the satellite galaxies, we find an assembly bias parameter of $Q_{\rm sat}{=}0.05{\pm}0.14$, a result consistent with zero and in tension with many empirical galaxy formation models. Our method provides a robust approach for characterizing galaxy assembly bias to achieve precision cosmology with DESI and future Stage-V surveys.

Shao, Zhiwei [Shanghai Jiaotong U.; Shanghai Jiao ↗

Terra-Populus v0.1: A Python Library for LandScan High-Definition Population Analysis and Modeling

The terra-populus library is designed for use by the LandScan HD technical team, offering a streamlined set of tools for generating and updating LandScan HD datasets from foundational building-level data, referred to as 'molecules,' provided by the building-level attribution team. This document serves as the primary technical documentation for terra-populus. Version 0.1 of the library includes the core modeling components necessary for LandScan HD production. It enables the generation of the LandScan HD Baseline dataset as well as corresponding confidence measures for the occupancy rates used. Parameters have been included for incorporating damaged building indicators and changes in population, to faciliate the creation of rapid updates for LandScan HD. Future iterations of terra-populus will introduce tools for creating a confidence index, and quantifying and propagating uncertainty, facilitating the creation of probabilistic LandScan HD outputs. This report provides an overview of the tools available in the library and the corresponding code implementations. One of the key advancements implemented in terra-populus is a redefinition of the atomic modeling unit for LandScan HD. Traditionally, the LandScan HD vector analytical framework has generated population estimates at the building sub-component (molecule) level. However, terra-populus adopts a building-level modeling approach. This shift is an operational decision aimed at aligning LandScan HD outputs with confidence measures, which are computed and validated at the building level (confidence measures are not included in this version of terra-populus, aside from those associated with the occupancy rates). Additional advancements to the LandScan HD modeling, as implemented by terra-populus, include a minimum population value parameter and an auto assignment of building floor counts. The population minimum value was implemented to prevent buildings and subsequent LandScan HD pixels that contained small values that may not rasterize in production. An 'auto' value has been included as a method for dealing with buildings lacking floor count information, where it is the average floor count of all other buildings with a residential building use type tag. The logic behind this is to remain consistent with the current logic employed for dealing with building use type null instances, where a null use type is defaulted to residential since it is the most common building type. The auto logic is intended to apply the most common building floor count of the most common type of buildings. The tools provided in terra-populus represent a significant step forward in improving the efficiency, reproducibility, and transparency of the LandScan HD modeling process. As the library evolves, it will continue to serve as a foundational resource for high-resolution population modeling.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Bedroom Concentrations and Emissions of Volatile Organic Compounds during Sleep

Because humans spend about one-third of their time asleep in their bedrooms and are themselves emission sources of volatile organic compounds (VOCs), it is important to specifically characterize the composition of the bedroom air that they experience during sleep. This work uses real-time indoor and outdoor measurements of volatile organic compounds (VOCs) to examine concentration enhancements in bedroom air during sleep and to calculate VOC emission rates associated with sleeping occupants. Gaseous VOCs were measured with proton-transfer reaction time-of-flight mass spectrometry during a multiweek residential monitoring campaign under normal occupancy conditions. Results indicate high emissions of nearly 100 VOCs and other species in the bedroom during sleeping periods as compared to the levels in other rooms of the same residence. Air change rates for the bedroom and, correspondingly, emission rates of sleeping-associated VOCs were determined for two bounding conditions: (1) air exchange between the bedroom and outdoors only and (2) air exchange between the bedroom and other indoor spaces only (as represented by measurements in the kitchen). VOCs from skin oil oxidation and personal care products were present, revealing that many emission pathways can be important occupant-associated emission factors affecting bedroom air composition in addition to direct emissions from building materials and furnishings.

54 ENVIRONMENTAL SCIENCES↗

The CMS Phase II Outer Tracker Upgrade at Fermilab

● Extracted threshold in electrons from S-curve measurement ● Estimated cut for noisy channels based on maximum module occupancy 10−6 ● ~40 channels offline masked ● Measured efficiencies and noise occupancies as a function of the threshold ● Source of inefficiency in the pixels due to punch through structure ● Inefficiencies in the strips after irradiation being investigated, the threshold used was not correct

Salimbeni, Nicolò↗

Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes: Measured Data From Select Southeastern States

Little data is available that quantifies IAQ or associates contaminant levels with air exchange in U.S. homes. To address this gap, the U.S. Department of Energy (DOE) Building America Program conducted a study to characterize IAQ in U.S. homes constructed since 2013, along with presence, functionality, and occupant use of control measures. Specific objectives of this study effort included: Measuring time-integrated concentrations and temporal profiles of established contaminants of concern; monitoring the use of ventilation equipment; and tracking activities that impact air pollutant emissions and removal processes in typical homes in various climate zones; Characterizing the prevalence, type, and installed performance of mechanical ventilation equipment in new homes; exploring regional variations in system designs and performance; Investigating associations between contaminant levels and the presence of control measures including whole-house mechanical ventilation (WHMV). The study engaged research teams to collect data at a regional level. This report introduces the study protocol and presents and discusses high-level results obtained from Florida Solar Energy Center (FSEC) data collection efforts in the southeastern U.S. states of Florida, Georgia, and South Carolina.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hot, cold, or just right? An infrared biometric sensor to improve occupant comfort and reduce overcooling in buildings via closed-loop control

To improve occupant comfort and save energy in buildings, we have developed a closed-loop air conditioning (AC) sensor-controller that predicts occupant thermal sensation from the thermographic measurement of skin temperature distribution, then uses this information to reduce overcooling (cooling-energy overuse that discomforts occupants) by regulating AC output. Taking measures to protect privacy, it combines thermal-infrared (TIR) and color (visible spectrum) cameras with machine vision to measure the skin-surface temperature profile. Since the human thermoregulation system uses skin blood flow to maintain thermoneutrality, the distribution of skin temperature can be used to predict warm, neutral, and cool thermal states. We conducted a series of human-subject thermal-sensation trials in cold-to-hot environments, measuring skin temperatures and recording thermal sensation votes. We then trained random-forest classification machine-learning models (classifiers) to estimate thermal sensation from skin temperatures or skin-temperature differences. The estimated thermal sensation was input to a proportional integral (PI) control algorithm for the AC, targeting a sensation level between neutral and warm. Our sensor-controller includes a sensor assembly, server software, and client software. The server software orients the cameras and transmits images to the client software, which in turn assesses occupant skin temperature distribution, estimates occupant thermal sensation, and controls AC operation. A demonstration conducted in a conference room in an office building near Houston, TX showed that our system reduced overcooling, decreasing AC load by 42% when the room was occupied while improving occupant comfort (fraction of “comfortable” votes) by 15 percentage points.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating internal moisture generation rates in recently constructed, occupied homes in the southeastern United States

Internal moisture generation (IMG), or moisture generated by building occupants via activities such as respiration, cooking, bathing, and cleaning, is a critical input required for design, analysis, and simulation of building enclosure and heating, ventilation, and air conditioning (HVAC) systems. Based on previously published values, ASHRAE Standard 160-2021 provides guidance for estimating IMG rates for moisture control design analysis, which is based on occupied home datasets collected in the 1980s and 1990s. Residential energy use simulation software also utilizes estimates for IMG for energy rating, energy analysis, and code compliance calculations, as specified in ANSI/RESNET/ICC Standard 301. Data quantifying IMG rates in newer homes is useful in determining the continued relevance of current design and simulation guidance, and whether the guidance represents conditions found in new housing stock. ASHRAE Research Project 1844, conducted by the Florida Solar Energy Center (FSEC), a research institute of the University of Central Florida, estimated IMG rates in newer occupied homes built since 2013 in the southeastern US using a moisture balance model approach. Furthermore, the project obtained occupied home data in cooperation with a US Department of Energy Building America research project to characterize indoor air quality (IAQ) in newer US homes, along with presence, functionality, and occupant use of control measures. Full-scale laboratory homes operating with known IMG rates were used to validate a moisture balance model and quantify the accuracy of estimates obtained when the model is applied to data from occupied homes with unknown IMG rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DESI Emission-line Galaxies: Unveiling the Diversity of [O II ] Profiles and Its Links to Star Formation and Morphology

We study the [O II ] profiles of emission-line galaxies (ELGs) from the Early Data Release of the Dark Energy Spectroscopic Instrument (DESI). To this end, we decompose and classify the shape of [O II ] profiles with the first two eigenspectra derived from principal component analysis. Our results show that DESI ELGs have diverse line profiles, which can be categorized into three main types: (1) narrow lines with a median width of ∼50 km s −1 , (2) broad lines with a median width of ∼80 km s −1 , and (3) two redshift systems with a median velocity separation of ∼150 km s −1 , i.e., double-peak galaxies. To investigate the connections between the line profiles and galaxy properties, we utilize the information from the COSMOS data set and compare the properties of ELGs, including star formation rate (SFR) and galaxy morphology, with the average properties of reference star-forming galaxies with similar stellar mass, sizes, and redshifts. Our findings show that, on average, DESI ELGs have a higher SFR and more asymmetrical/disturbed morphology than the reference galaxies. Moreover, we uncover a relationship between the line profiles, the excess SFR, and the excess asymmetry parameter, showing that DESI ELGs with broader [O II ] line profiles have more disturbed morphology and higher SFR than the reference star-forming galaxies. Finally, we discuss possible physical mechanisms giving rise to the observed relationship and the implications of our findings on the galaxy clustering measurements, including the halo occupation distribution modeling of DESI ELGs and the observed excess velocity dispersion of the satellite ELGs.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Resilience of Buildings and Communities: A Multistakeholder Review of Metrics and Approaches

Increasing temperature-related hazards require a collective effort to assess and enhance the thermal resilience of buildings and communities to protect occupants’ safety and minimize property or infrastructure damage. However, limited coordination across stakeholders and lack of standardized procedures for resilience assessment undermine the effectiveness of extreme temperature mitigation and adaptation strategies across the building life cycle. This review examines the current literature on resilience metrics to address thermal stress and risk due to extreme indoor environments. Stakeholders of thermal resilience include architects and engineers, occupants, property owners, real estate developers, urban planners, and policymakers. Additionally, motivations for measuring thermal resilience are emphasized, such as safeguarding occupant health and survivability, protecting property, and ensuring business continuity during extreme weather events. This review provides actionable insights and identifies future research needs for enhancing resilience through tailored metrics for stakeholders during the planning, design, construction, operation, and retrofitting phases of buildings and communities.

building life cycle↗

Framework to select robust energy retrofit measures for residential communities

Residential building energy retrofits are essential for enhancing environmental sustainability and reducing energy costs. The selection of retrofit measures is influenced by factors such as building systems, occupant behavior, government policy, weather variability, and climate change, all of which can significantly impact energy performance. Compared to retrofitting individual homes, evaluating and selecting optimal retrofit solutions for an entire community is challenging due to diverse residential compositions and variability present. Therefore, engineering robustness is crucial for ensuring consistent energy performance and resilience across different conditions. In this context, robustness refers to the ability of a retrofit measure to maintain its functionality and remain an optimal choice despite external disturbances or changes in inputs and conditions. This study presents a framework for evaluating the robustness of multiple retrofit measures across various building systems, occupant behaviors, and environmental scenarios at the community level. The framework comprises five key steps: scenario model development, integration of the National Residential Efficiency Measures database, energy performance simulation, cost-benefit aggregation, and retrofit solution selection. Each step enhances the framework’s robustness by incorporating the diversity of building characteristics, occupant behaviors, environmental conditions, retrofit options, and evaluation criteria. The framework’s effectiveness is demonstrated through a case study in southern Michigan in the United States, which includes 63 one-story single-family houses, 121 two-story single-family houses, and 8 townhouses. The study identifies furnace retrofits as the most robust solution for the entire community, consistently achieving source energy reductions of 4.7 %–8.0 % and payback period of 10–20 years across various scenarios. These findings are consistent with previous research, indicating the framework’s potential for broader applications in optimizing community-scale residential energy retrofits.

Shu, Lei↗

Risk Ratio and Risk Difference Estimation in Case-cohort Studies

Background: In case-cohort studies with binary outcomes, ordinary logistic regression analyses have been widely used because of their computational simplicity. However, the resultant odds ratio estimates cannot be interpreted as relative risk measures unless the event rate is low. The risk ratio and risk difference are more favorable outcome measures that are directly interpreted as effect measures without the rare disease assumption. Methods: We provide pseudo-Poisson and pseudo-normal linear regression methods for estimating risk ratios and risk differences in analyses of case-cohort studies. These multivariate regression models are fitted by weighting the inverses of sampling probabilities. Also, the precisions of the risk ratio and risk difference estimators can be improved using auxiliary variable information, specifically by adapting the calibrated or estimated weights, which are readily measured on all samples from the whole cohort. Finally, we provide computational code in R (R Foundation for Statistical Computing, Vienna, Austria) that can easily perform these methods. Results: Through numerical analyses of artificially simulated data and the National Wilms Tumor Study data, accurate risk ratio and risk difference estimates were obtained using the pseudo-Poisson and pseudo-normal linear regression methods. Also, using the auxiliary variable information from the whole cohort, precisions of these estimators were markedly improved. Conclusion: The ordinary logistic regression analyses may provide uninterpretable effect measure estimates, and the risk ratio and risk difference estimation methods are effective alternative approaches for case-cohort studies. These methods are especially recommended under situations in which the event rate is not low.

60 APPLIED LIFE SCIENCES↗