Search NASA⌕ Search

SEARCH · Search NASA

Results for “Octave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Simultaneous on-chip generation of violet, blue, cyan, green, yellow, orange, and red light from an octave-spanning infrared frequency comb

An integrated, multi-spectral visible-light source could significantly benefit technologies such as displays, medical imaging, spectroscopy, visible-light communications, and astrophysics. However, despite recent advances in chip-scale visible lasers, simultaneously generating light of all colors in a single chip has been challenging. Existing solutions are either not suitable for full chip-scale integration, or are fundamentally difficult to scale. Here we demonstrate the simultaneous on-chip generation of infrared, red, orange, yellow, green, cyan, blue, and violet light. Leveraging the low loss, low dispersion, and high density of modes of an adiabatic multimode silicon nitride (SiN) microresonator, we use a single infrared pump of moderate power (~130 mW) to produce an octave-spanning infrared frequency comb that is then converted to different portions of the visible spectrum. We measure non-mode-locked combs and soliton steps corresponding to mode-locked states, making our comb generator suitable for applications that demand either low or high coherence. Since the required pump power is compatible with high-power lasers demonstrated in the same SiN platform, our multi-octave light generator can be fully integrated in a chip-scale form factor. We envision that such a light source will be a catalyst for the development and deployment of miniaturized multi-spectral technologies for quantum systems, medical imaging, displays, and spectroscopy.

47 OTHER INSTRUMENTATION↗

The Noisiness of Low-Frequency One-Third Octave Bands of Noise

This study examined the relative noisiness of low frequency one-third octave bands of noise bounded by the bands centered at 25 Hz and 200 Hz, with intensities ranging from 50 db sound pressure level (SPL) to 95 db SPL. The thirty-two subjects used a method-of-adjustment technique, producing comparison-band intensities as noisy as standard bands centered at 100 Hz and 200 Hz with intensities of 60 db SPL and 72 db SPL. Four contours of equal noisiness were developed for one-third octave bands, extending down to 25 Hz and ranging in intensity from approximately 58 db SPL to 86 db SPL. These curves were compared with the contours of equal noisiness of Kryter and Pearsons. In the region of overlap (between 50 Hz and 200 Hz) the agreement was good.

Lawton, B. W.↗

Atmospheric absorption of high frequency noise and application to fractional-octave bands

Pure tone sound absorption coefficients were measured at 1/12 octave intervals from 4 to 100 KHz at 5.5K temperature intervals between 255.4 and 310.9 K and at 10 percent relative humidity increments between 0 percent and saturation in a large cylindrical tube (i.d., 25.4 cm; length, 4.8 m). Special solid-dielectric capacitance transducers, one to generate bursts of sound waves and one to terminate the sound path and detect the tone bursts, were constructed to fit inside the tube. The absorption was measured by varying the transmitter receiver separation from 1 to 4 m and observing the decay of multiple reflections or change in amplitude of the first received burst. The resulting absorption was compared with that from a proposed procedure for computing sound absorption in still air. Absorption of bands of noise was numerically computed by using the pure tone results. The results depended on spectrum shape, on filter type, and nonlinearly on propagation distance. For some of the cases considered, comparison with the extrapolation of ARP-866A showed a difference as large as a factor of 2. However, for many cases, the absorption for a finite band was nearly equal to the pure tone absorption at the center frequency of the band. A recommended prediction procedure is described for 1/3 octave band absorption coefficients.

Shields, F. D.↗

A computer-controlled instrumentation system for third octave analysis

An instrumentation system is described which employs a minicomputer, a one-third octave band analyzer, and a time code/tape search unit for the automatic control and analysis of third-octave data. With this system the information necessary for data adjustment is formatted in such a way as to eliminate much operator interface, thereby substantially reducing the probability for error. A description of a program for the calculation of effective perceived noise level from aircraft noise data is included as an example of how this system can be used.

Faulcon, N. D.↗

Rye Canyon X-ray noise test: One-third octave-band data

Acoustic data were obtained for the 25 ft. diameter X-wing rotor model during performance testing of the rotor system in hover. Data collected at the outdoor whirl tower test facility with a twelve microphone array were taken for approximately 150 test conditions comprised of various combinations of RPM, blade pressure ratio (BPR), and blade angle of attack (collective). The three test parameters had four values of RPM from 404 to 497, twelve values of BPR from 1.0 to 2.1, and six values of collective from 0.0 deg to 8.5 deg. Fifteen to twenty seconds of acoustic data were reduced to obtain an average 1/3 octave band spectrum for each microphone for each test condition. The complete, as measured, 1/3 octave band results for all the acoustic data are listed. Another part of the X-wing noise test was the acoustic calibration of the Rye Canyon whirl tower bowl. Corrections were computed which, when applied to as measured data, yield estimates of the free field X-wing noise. The free field estimates provide a more realistic measure of the rotor system noise levels. Trend analysis of the three test parameters on noise level were performed.

Willshire, W. L., Jr.↗

Octave-spanning terahertz quarter-wave plates based on over-coupled Fabry–Pérot resonances in reflective metal–dielectric–metal metasurfaces

Compact devices for broadband polarization control in the terahertz (THz) regime remain challenging to realize due to the intrinsic phase dispersion associated with birefringent materials and resonant structures. Here, we demonstrate achromatic THz quarter-wave plates with near-unity efficiency and operating under a wide range of incidence angles, based on over-coupled metal–dielectric–metal reflective metasurfaces. The devices operate as single-port anisotropic Fabry–Pérot cavities, in which the phase dispersion of the over-coupled resonances is engineered to maintain an approximately constant relative phase delay between orthogonal field components over a broad frequency range. Four complementary metasurface designs operating at an incidence angle of 45° collectively cover the 0.25–3 THz frequency range accessible to a typical THz time-domain spectroscopy system. Each device exhibits an approximately octave-wide operational bandwidth, with axial ratios below 3 dB and polarization-conversion efficiencies exceeding 80% across most of the operating band. Systematic structural optimization suppresses coupling to diffraction and guided-wave modes, thereby further extending the usable bandwidth while preserving the required phase relationship between orthogonal polarizations. The demonstrated metasurfaces are compatible with wafer-scale fabrication processes, and experimental results show excellent agreement with simulations. These findings establish over-coupled reflective metasurfaces as a robust, scalable, and versatile platform for broadband THz polarization control.

36 MATERIALS SCIENCE↗

Prototype partial one-third octave band spectrum analyzer for acoustic, vibration and other wideband data for flight applications

The design refinement of a compact frequency analyzer for measurement and analysis on board flight vehicles is discussed. The analyzer has been constructed in a partial one-third octave band configuration with six filters and detectors spaced by the square root of 10 from 316 Hz to 100,000 Hz and a broadband detector channel. The analyzer has been tested over a temperature range of 40 to 120 F at a pressure of one atmosphere, and at a temperature of 75 F at an absolute pressure of 0.000001 torr, and has demonstrated at least 60 db of dynamic range.

Source record↗

Automatic measuring device for octave analysis of noise

An automatic decoder is described that counts noise levels by pulse counters and forms audio signals proportional in duration to the total or to one of the octave noise levels. Automatic ten fold repetition of the measurement cycle is provided at each measurement point before the transition to a new point is made.

Memnonov, D. L.↗

Small-size 81- to 83.5-percent efficient 2- and 4-stage depressed collectors for octave-bandwidth high-performance TWT's

In a joint USAF-NASA Program, Lewis Research Center is carrying out an efficiency improvement program on traveling wave tubes for use in electronic counter measures by applying multistage depressed collector (MDC) and spent beam refocusing techniques. In the analytic part of the effort, three-dimensional electron trajectories are computed throughout the TWT. On the experimental side, tube performance is evaluated first without the MDC; then, the spent beam is analyzed for symmetry, circularity, and velocity spread. The three-dimensional theory predicts a MDC-efficiency, at mid-band, of 81 per cent for a 2-stage MDC with symmetric, circular, and optimally refocused beams and 85.5 per cent for a 4-stage MDC. Experimental results to date have yielded MDC efficiencies of a minimum of 81 and 83 per cent for a 2- and 4-stage MDC, respectively, across a one-octave bandwidth of a 4.8 to 9.6 GHz 330-to-550-W TWT.

Kosmahl, H. G.↗

Octave-Band Thresholds for Modeled Reverberant Fields

Auditory thresholds for 10 subjects were obtained for speech stimuli reverberation. The reverberation was produced and manipulated by 3-D audio modeling based on an actual room. The independent variables were octave-band-filtering (bypassed, 0.25 - 2.0 kHz Fc) and reverberation time (0.2- 1.1 sec). An ANOVA revealed significant effects (threshold range: -19 to -35 dB re 60 dB SRL).

Begault, Durand R.↗

How Do UTLS Jet and Tropopause Dynamics Influence Ozone Variability? Investigations Supporting the SPARC OCTAV-UTLS Activity

Understanding changes in UTLS ozone is exceptionally challenging because of large spatial and temporal variability and because of the difficulty of satellite measurements in the UTLS. It is also exceptionally important: for example, to understand climate impacts of radiatively active substances and to understand physical and biological effects of pollution transport and stratosphere-troposphere exchange (STE). Multi-decadal global observations of UTLS ozone are now available from numerous satellite platforms, as well as local and regional observations from aircraft, balloons, and lidar. The upper tropospheric (UT) jets and tropopauses are important drivers of composition variability in the UTLS, acting as transport barriers and controlling STE and long-range transport. We report here on investigations of relationships between extratropical UTLS ozone variability and dynamical diagnostics of mixing / transport barriers, Rossby Wave breaking, and stratosphere-troposphere exchange. We will view these relationships in the context of ozone mapped into dynamical coordinates with respect to the UTLS jets and / or the tropopause. This work will help provide direction for analyses within the Stratosphere-troposphere Processes And their Role in Climate (SPARC) Observed Composition Trends and Variability in the UTLS (OCTAV-UTLS) activity, which aims to use dynamical coordinate mapping to help detect and attribute observed UTLS composition trends, and to project future data needs to better quantify those trends. The work we report on here will focus on satellite ozone observations (primarily from the Aura Microwave Limb Sounder, additionally from ACE-FTS and OSIRIS) and assimilated ozone and dynamical fields (from multiple reanalyses); we will also provide some examples of comparisons with aircraft and balloon observations.

Manney, Gloria L.↗

baseflow: a MATLAB and GNU Octave package for baseflow recession analysis

baseflow is a MATLAB® toolbox designed for baseflow recession analysis, a technique used in hydrologic science to infer aquifer properties from streamflow. By leveraging widely available streamflow data, baseflow can be used to estimate aquifer properties such as hydraulic conductivity and drainable porosity over the modern instrumental stream gage record. The toolbox is intended for analysis of measured streamflow values recorded on a daily timestep, and is tailored for shallow, unconfined riparian aquifers that discharge groundwater laterally into adjacent streams. Additionally, baseflow can analyze the collective behavior of individual hillslope aquifers constituting hydrologic catchments, known as “watersheds”, from a nonlinear dynamical systems perspective. The toolbox incorporates recent advances in baseflow recession analysis to enable objective estimations of aquifer properties, and their sensitivity to methodological decisions, at both hillslope and catchment scales.

97 MATHEMATICS AND COMPUTING↗

An 82 to 84 percent efficient, small size, 2 and 4 stage depressed collector for octave bandwidth high performance TWT's

Improvements were carried out on a TWT (traveling wave tube) for use in EMC (electronic countermeasure) systems by applying MDC (multi-stage depressed collector) and spent-beam refocusing techniques. The MDC geometric design consists of six collecting elements (electrodes) at ground and cathode potentials operating in 2 or 4 stage configuration. The refocusing system designed allows a controlled beam expansion to the point that space charge becomes negligible at the MDC entrance. Simultaneously, the standard deviation of the radial velocity (angular spread) is reduced. This system provides an analog real time readout of P(recovered). Data on all tests is obtained with an automated data acquisition system.

Kosmahl, H.↗

Single stage, low noise, advanced technology fan. Volume 5: Fan acoustics. Section 2: One-third octave data tabulations and selected narrowband traces

The raw-acoustic data corrected to standard day, from acoustic tests performed on a 0.508-scale fan vehicle of a 111,300 newton thrust, full-size engine, which has application on an advanced transport aircraft, are presented. The single-stage advanced technology fan was designed to a pressure ratio of 1.8 at a tip speed of 503 m/sec to achieve the desired pressure ratio in a single-stage fan with low radius ratio, and to maintain adequate stall margin. The two basic approaches taken in the acoustic design were: (1) minimization of noise at the source, and (2) suppression of the generated noise in the inlet and bypass exhaust duct. Suppression of the generated noise was accomplished in the inlet through use of the hybrid concept (wall acoustic treatment plus airflow acceleration suppression) and in the exhaust duct with extensive acoustic treatment including a splitter. The goal of the design was attainment of twenty effective perceived noise decibels. The suppression goal of FAR 36-20 was not reached, but improvements in the technology of both front and aft fan-noise suppression were realized.

Jutras, R. R.↗

Efficiency enhancement of octave-bandwidth TWT's by the use of multistage depressed collectors

A small size two and four stage depressed collector was evaluated in conjunction with a 4.8 to 9.6 GHz traveling wave tube of 325 to 675 W power output. In spite of large fixed traveling wave tube losses, very significant efficiency enhancement was demonstrated with both the two and four stage multistage depressed collectors (MDC). The improvement in the overall efficiency ranged from a factor of 2.5 to 3.0 for the two stage MDC and a factor of 3.0 to 3.5 for the four stage MDC. An overall efficiency of 37.0 to 44.3 percent across the frequency band was demonstrated with the use of harmonic injection.

Ramins, P.↗