Search NASA⌕ Search

SEARCH · Search NASA

Results for “On-line monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design of a specialized computer for on-line monitoring of cardiac stroke volume

The design of a specialized analog computer for on-line determination of cardiac stroke volume by means of a modified version of the pressure pulse contour method is presented. The design consists of an analog circuit for computation and a timing circuit for detecting necessary events on the pressure waveform. Readouts of arterial pressures, systolic duration, heart rate, percent change in stroke volume, and percent change in cardiac output are provided for monitoring cardiac patients. Laboratory results showed that computational accuracy was within 3 percent, while animal experiments verified the operational capability of the computer. Patient safety considerations are also discussed.

Webb, J. A., Jr.↗

Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions

Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.

47 OTHER INSTRUMENTATION↗

Fluorescence Signatures of Rare Earth Metals during Precipitation in Various Conditions

Fluorescence spectroscopy is a widely used sensor methodology that analyzes light emitted from a compound or element as it decays from an excited state. This technique is very sensitive and selective, which is ideal to characterize analytes at lower limits of detection. Key example targets of significant industry and research interest include rare earth elements (REEs) such as dysprosium (Dy) and europium (Eu). These are widely used in advanced technologies including semiconductors, electric vehicle motors, lasers, and permanent magnets. Identifying new sources and responsible reutilization of REEs is essential, and new approaches to extract and recycle REEs could be notably enhanced through the integration of on-line sensors. The sensors can support faster process design, informed scale-up, and cost-effective deployment. This study covers the initial exploration of applying fluorescence-based on-line monitoring to REEs within a precipitation process. This study demonstrates the successful scale-up of a fluorescence -based sensing approach, from stationary cuvettes and small-volume microfluidic devices to continuous flow systems operating at the bench scale (10-25mL). This work also provides initial insight into the challenges of signal’s effects and utility within a turbid environment. Using a modular design for monitoring flowing solutions in a flow tube, fluorescence can be characterized for a variety of analytical targets. In this study, detection performance parameters between the cuvette and flow tube system were compared. Additionally, the response of Dy during precipitation by sodium bicarbonate in the two measurement designs was explored. This letter represents a starting point to bridge the gap between traditional fluorescence sensor measurements in a cuvette to future developments that explore the ability to integrate fluorescence sensors into extraction and separation processes at industrially relevant scales.

fluorescence↗

Preliminary Plan to Inform Testing of a Heat Exchanger Test Article

This report presents a preliminary plan to guide the qualification testing of advanced heat exchanger (HX) components for nuclear-to-industrial heat transfer applications. The objective is to establish a defensible, physics-based methodology that integrates computational modeling, targeted experimentation, and in-service inspection considerations to demonstrate component performance and reliability under representative reactor conditions. The analysis identifies Sodium-cooled Fast Reactor (SFR) and High-Temperature Gas-cooled Reactor (HTGR) systems as reference configurations in terms of temperature, pressure, and chemical environment. Within these operating envelopes, dominant degradation mechanisms— including creep–fatigue interaction, flow-induced vibration, corrosion, and diffusion-bond deterioration—were evaluated to define test requirements. A comprehensive computationalexperimental framework is proposed to support life prediction and qualification activities. The framework couples high-fidelity structural-mechanics, thermal-hydraulic, and fluid-structure interaction models with accelerated degradation testing to produce a traceable linkage between microstructural evolution, mechanical performance, and remaining useful life (RUL). The approach adheres to established Verification, Validation, and Uncertainty Quantification (VVUQ) standards (ASME V&V 10/20; NUREG-2152) and incorporates a digital-twin architecture for continuous model refinement through data assimilation. The plan further outlines testing methodologies, including pre-test analyses, test-loop design parameters, and sensor placement strategies that maximize information yield while maintaining mechanistic fidelity. Complementary sections describe in-service inspection (ISI), on-line monitoring (OLM), and structural-health-monitoring (SHM) techniques applicable to compact HX geometries typical of advanced reactors. Collectively, these activities establish the technical foundation for demonstrating 40-60-year equivalent service life of advanced heat exchangers in support of the U.S. Department of Energy’s Advanced Reactor and Integrated Energy Systems programs. The forthcoming phase will execute the defined pre-test analyses, initiate hardware fabrication, and implement the integrated testing campaign to validate the proposed qualification methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗

Real-time gross actinide monitoring in extreme (10 6 :1) beta-gamma background fluid streams using mini-ATMFDs

Real-time, trace alpha activity monitoring in extreme mixed radiation fields is a well-known challenge in fission product-rich streams containing mixtures of beta-gamma-alpha radiation-emitting isotopes, arising due to the extreme 10 6 :1 ratio of background beta-gamma vs. alpha radiation activity levels. This paper presents results from a novel approach to addressing this challenge, based on Tensioned Metastable Fluid Detector (TMFD) sensing technology. An acoustically driven technique was developed and tested at Purdue University (using dissolved Rn-Po and U-chain alpha emitters), and validated (with dissolved Pu) at Savannah River National Laboratory for real-time monitoring of alpha activity in the 100–10,000 dpm/mL range.

Environmental Monitoring↗

Additional studies for the spectrophotometric measurement of iodine in water

Previous work in iodine spectroscopy is briefly reviewed. Continued studies of the direct spectrophotometric determination of aqueous iodine complexed with potassium iodide show that free iodine is optimally determined at the isosbestic point for these solutions. The effects on iodine determinations of turbidity and chemical substances (in trace amounts) is discussed and illustrated. At the levels tested, iodine measurements are not significantly altered by such substances. A preliminary design for an on-line, automated iodine monitor with eventual capability of operating also as a controller was analyzed and developed in detail with respect single beam colorimeter operating at two wavelengths (using a rotating filter wheel). A flow-through sample cell allows the instrument to operate continuously, except for momentary stop flow when measurements are made. The timed automatic cycling of the system may be interrupted whenever desired, for manual operation. An analog output signal permits controlling an iodine generator.

Source record↗

A computer-controlled scintiscanning system and associated computer graphic techniques for study of regional distribution of blood flow.

Two methods whereby a digital computer may be used to regulate a scintiscanning process are discussed from the viewpoint of computer input-output software. The computer's function, in this case, is to govern the data acquisition and storage, and to display the results to the investigator in a meaningful manner, both during and subsequent to the scanning process. Several methods (such as three-dimensional maps, contour plots, and wall-reflection maps) have been developed by means of which the computer can graphically display the data on-line, for real-time monitoring purposes, during the scanning procedure and subsequently for detailed analysis of the data obtained. A computer-governed method for converting scintiscan data recorded over the dorsal or ventral surfaces of the thorax into fractions of pulmonary blood flow traversing the right and left lungs is presented.

Coulam, C. M.↗

Study to design and develop remote manipulator system

Human performance measurement techniques for remote manipulation tasks and remote sensing techniques for manipulators are described for common manipulation tasks, performance is monitored by means of an on-line computer capable of measuring the joint angles of both master and slave arms as a function of time. The computer programs allow measurements of the operator's strategy and physical quantities such as task time and power consumed. The results are printed out after a test run to compare different experimental conditions. For tracking tasks, we describe a method of displaying errors in three dimensions and measuring the end-effector position in three dimensions.

Hill, J. W.↗

Development of a digital control system for a spacecraft propulsion test facility

A digital computer control and abort system which is used at NASA-Lewis research center is described. The system was designed to control test operations such as rocket engine testing, structure testing, and wind tunnel tests. Because of the nature of spacecraft system testing, particularly rocket engine testing, the unique features of the system are, control function updating at a 20 millisecond rate, continuous abort monitoring and a software system designed for short duration tests rather than continuous on-line control. To accomplish these system requirements, special hardware was designed. The presentation includes a description of the computer system and special interface hardware as well as a general description of the software used.

Smalley, R. R.↗

Development of a digital control system for a spacecraft propulsion test facility.

A digital computer control and abort system which is used at NASA-Lewis Research Center's Plum Brook Test Facilities is described. The system was designed by NASA personnel to control test operations such as rocket engine testing, structure testing, and wind tunnel tests. Because of the nature of spacecraft system testing, particularly rocket engine testing, the unique features of the system are, control function updating at a 20 millisecond rate, continuous abort monitoring and a software system designed for short duration tests rather than continuous on-line control. To accomplish these system requirements, special hardware was designed. The presentation will include a description of the computer system including special interface hardware as well as a general description of the software used.

Smalley, R. R.↗

Development of a digital control system for a spacecraft propulsion test facility.

Description of a digital computer control and abort system designed by NASA personnel to control test operations such as rocket engine testing, structure testing, and wind tunnel tests. Because of the nature of spacecraft system testing, particularly rocket engine testing, the unique features of the system are, control function updating at a 20 millisecond rate, continuous abort monitoring, and a software system designed for short duration tests rather than continuous on-line control. The presentation includes a description of the computer system and special interface hardware as well as a general description of the software used.

Smalley, R. R.↗

Research program for experiment M133

The development of the automatic data-acquisition and sleep-analysis system is reported. The purpose was consultation and evaluation in the transition of the Skylab M133 Sleep-Monitoring Experiment equipment from prototype of flight status; review of problems associated with acquisition and on-line display of data in near-real time via spacecraft telemetry; and development of laboratory facilities and design of equipment to assure reliable playback and analysis of analog data. The existing prototype system modified, and the changes improve the performance of the analysis circuitry and increase its reliability. These modifications are useful for pre- and postflight analysis, but are not now proposed for the inflight system. There were improvements in the EEG recording cap, some of which will be incorporated into the flight hardware.

Frost, J. D., Jr.↗

Feasibility of an on-line fission-gas-leak detection system

Calculations were made to determine if a cladding failure could be detected in a 100-kW zirconium hydride reactor primary system by monitoring the highly radioactive NaK coolant for the presence of I-131. The system is to be completely sealed. A leak of 0.01 percent from a single fuel pin was postulated. The 0.364-MeV gamma of I-131 could be monitored on an almost continuous basis, while its presence could be varified by using a longer counting time for the 0.638-MeV gamma. A lithium-drifted germanium detector would eliminate radioactive corrosion product interference that could occur with a sodium iodide scintillation detector.

Lustig, P. H.↗

Automated iodine monitor system

The feasibility of a direct spectrophotometric measurement of iodine in water was established. An iodine colorimeter, was built to demonstrate the practicality of this technique. The specificity of this method was verified when applied to an on-line system where a reference solution cannot be used, and a preliminary design is presented for an automated iodine measuring and controlling system meeting the desired specifications. An Automated iodine monitor/controller system based on this preliminary design was built, tested, and delivered to the Johnson Space Center.

Source record↗