Search NASA⌕ Search

SEARCH · Search NASA

Results for “On-line monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Numerical Studies of the On-Line Reactivity Monitoring Techniques in Subcritical Systems: Revisit of the Area-Ratio Method, the Neutron Source-Modulation Method, and the Flux-to-Current Ratio Method

In the subcritical systems, the subcriticality level must be monitored continuously to ensure the safe operation of the systems. Techniques such as the neutron source-modulation method and the flux-to-current ratio method have been proposed for on-line reactivity measurements of the subcritical systems. However, the accuracy of these methods is unknown in the actual applications. In this report, the fundamental concepts of these techniques are visited, with numerical simulation techniques developed to validate these on-line reactivity monitoring methodologies. Specifically, the Monte Carlo numerical simulation results show that the neutron source-modulation method is not accurate in determining the reactivity of the subcritical systems. The flux-to-current ratio method can provide on-line reactivity measurements, and its spatial effects have been studied and well understood through the numerical simulations of the fuel loading of the neutron source facility of Ukraine. In addition, a modified version of the area-ratio method is proposed for the on-line measurements of the absolute reactivity of the subcritical systems. Monte Carlo numerical simulations showed that this method can provide the absolute reactivity of the subcritical systems within ~5% error, if the neutron detectors are placed close to the fuel assembly interface with the reflector zone or in the reflector zones away from the neutron source.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions

Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.

47 OTHER INSTRUMENTATION↗

Real-time infrared spectroscopy coupled with blind source separation for nuclear waste process monitoring

On-line infrared absorbance spectroscopy enables rapid measurement of solution-phase molecular species. Many spectra-to-concentration models exist for spectral data, with some models able to handle overlapping spectral bands and nonlinearities. However, model accuracy is limited by the quality of training data used in model fitting. The process spectra of nuclear waste simulants at the Savannah River Site display incongruity between training and process spectra; the glycolate spectral signature in the training data does not match the glycolate signature in Savannah River National Laboratory process data. A novel blind source separation algorithm is proposed that preprocesses spectral data so that process spectra more closely resemble training spectra, thereby improving model quantification accuracy when unexpected sources of variation appear in process spectra. The novel blind source separation preprocessing algorithm is shown to improve nitrate quantification from an R 2 of 0.934 to 0.988 and from 0.267 to 0.978 in two instances analyzing nuclear waste simulants from the Slurry Receipt Adjustment Tank and Slurry Mix Evaporator cycle at the Savannah River Site.

Crouse, Steven H.↗

Electrochemical Characterization of Molten Salt Chemistry During Atmospheric Ingressions

This report describes the salt chemistry and sedimentation studies that were completed in FY23 as part of the Pyrochemical Fuel Cycles – ANL project. The primary objective of these activities was to employ electrochemical methods in order to quantify and gain insights into the reaction mechanisms associated with the interaction of O2 and moisture impurities with the molten chloride salts used for the pyrochemical processing of nuclear materials. If not monitored and controlled, the ingression of these atmospheric impurities can lead to changes in the salt redox conditions and initiate the formation of oxide particles, potentially resulting in operational and safeguards challenges. By elucidating the mechanisms underlying the formation of oxide particles, we can effectively monitor the conditions of the salt and design systems to mitigate the influence of atmospheric O2 and H2O. To achieve these goals, we designed a test system that allowed for precisely controlled gas ingressions into the molten salt vessel. This system included on-line monitoring provided by electrochemical probes that enable near real-time measurements of the salt conditions throughout the course of the experiment. Using this system, we systematically varied experimental conditions, including O2/Ar flow rates and O2 concentrations, to comprehensively understand their impact on solid particle formation. We also used a particle size and shape analyzer to characterize the particles that were generated. Tests in FY23 concentrated on the formation of CeO2 particles, but we also prepared a separate apparatus targeting UO2 particles for use in FY24. We additionally conducted extensive modeling activities in support of this work. This included multiphysics simulations of the gas ingressions along with the development of a machine learning workflow to enable accelerated molecular dynamics modeling of the molten salt chemistry of LiCl-KCl-UCl3. The combination of experimental and modeling tools has allowed us to begin to get a more complete understanding of the reactions that occur when atmospheric ingressions occur in pyroprocessing systems.

Guo, Jicheng↗

Fluorescence Signatures of Rare Earth Metals during Precipitation in Various Conditions

Fluorescence spectroscopy is a widely used sensor methodology that analyzes light emitted from a compound or element as it decays from an excited state. This technique is very sensitive and selective, which is ideal to characterize analytes at lower limits of detection. Key example targets of significant industry and research interest include rare earth elements (REEs) such as dysprosium (Dy) and europium (Eu). These are widely used in advanced technologies including semiconductors, electric vehicle motors, lasers, and permanent magnets. Identifying new sources and responsible reutilization of REEs is essential, and new approaches to extract and recycle REEs could be notably enhanced through the integration of on-line sensors. The sensors can support faster process design, informed scale-up, and cost-effective deployment. This study covers the initial exploration of applying fluorescence-based on-line monitoring to REEs within a precipitation process. This study demonstrates the successful scale-up of a fluorescence -based sensing approach, from stationary cuvettes and small-volume microfluidic devices to continuous flow systems operating at the bench scale (10-25mL). This work also provides initial insight into the challenges of signal’s effects and utility within a turbid environment. Using a modular design for monitoring flowing solutions in a flow tube, fluorescence can be characterized for a variety of analytical targets. In this study, detection performance parameters between the cuvette and flow tube system were compared. Additionally, the response of Dy during precipitation by sodium bicarbonate in the two measurement designs was explored. This letter represents a starting point to bridge the gap between traditional fluorescence sensor measurements in a cuvette to future developments that explore the ability to integrate fluorescence sensors into extraction and separation processes at industrially relevant scales.

fluorescence↗

Noble Gas Transport in the MSRE

This study explores the relationship between the physicochemical parameter known as Henry’s gas constant and gas transport across a two-layer film interface. The investigation utilized the Gibbs free energy, incorporating surface and volume terms to elucidate trends in enthalpy and entropy. Notably, our findings align with experimental data and offer predictive insights into the Henry’s gas constants for helium and krypton, which hold significance for future experiments and theoretical developments. Furthermore, this study enhances the Gibbs free energy theory pertaining to the liquid–gas interface. It underscores the substantial contribution of noble gases in this region to volumetric energy as temperature increases. Additionally, we employed Monte Carlo simulations to analyze the effective thermal neutron multiplication factor, denoted as k eff . Our analysis reveals a linear correlation between graphite density and uniform density as a function of temperature. For the 1D Molten Salt Reactor Experiment (MSRE) system, we employed the Mole code to conduct heat and mass transfer calculations. These computations enable us to ascertain the distribution of fuel temperature based on coefficients and thermal properties. We also studied delayed neutron precursors during fuel cycling, taking into account the drift of cycling fuel through Mole–Griffin coupling. Our model represents k eff and β eff across various volume flow rates and salinity compositions. Finally, this study leveraged xenon-135 for continuous on-line monitoring of fuel salts to investigate the impact of steady-state xenon-135 on the MSRE and to better understand its distribution. These efforts build upon previous research related to removal processes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Plan to Inform Testing of a Heat Exchanger Test Article

This report presents a preliminary plan to guide the qualification testing of advanced heat exchanger (HX) components for nuclear-to-industrial heat transfer applications. The objective is to establish a defensible, physics-based methodology that integrates computational modeling, targeted experimentation, and in-service inspection considerations to demonstrate component performance and reliability under representative reactor conditions. The analysis identifies Sodium-cooled Fast Reactor (SFR) and High-Temperature Gas-cooled Reactor (HTGR) systems as reference configurations in terms of temperature, pressure, and chemical environment. Within these operating envelopes, dominant degradation mechanisms— including creep–fatigue interaction, flow-induced vibration, corrosion, and diffusion-bond deterioration—were evaluated to define test requirements. A comprehensive computationalexperimental framework is proposed to support life prediction and qualification activities. The framework couples high-fidelity structural-mechanics, thermal-hydraulic, and fluid-structure interaction models with accelerated degradation testing to produce a traceable linkage between microstructural evolution, mechanical performance, and remaining useful life (RUL). The approach adheres to established Verification, Validation, and Uncertainty Quantification (VVUQ) standards (ASME V&V 10/20; NUREG-2152) and incorporates a digital-twin architecture for continuous model refinement through data assimilation. The plan further outlines testing methodologies, including pre-test analyses, test-loop design parameters, and sensor placement strategies that maximize information yield while maintaining mechanistic fidelity. Complementary sections describe in-service inspection (ISI), on-line monitoring (OLM), and structural-health-monitoring (SHM) techniques applicable to compact HX geometries typical of advanced reactors. Collectively, these activities establish the technical foundation for demonstrating 40-60-year equivalent service life of advanced heat exchangers in support of the U.S. Department of Energy’s Advanced Reactor and Integrated Energy Systems programs. The forthcoming phase will execute the defined pre-test analyses, initiate hardware fabrication, and implement the integrated testing campaign to validate the proposed qualification methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗

Real-time gross actinide monitoring in extreme (10 6 :1) beta-gamma background fluid streams using mini-ATMFDs

Real-time, trace alpha activity monitoring in extreme mixed radiation fields is a well-known challenge in fission product-rich streams containing mixtures of beta-gamma-alpha radiation-emitting isotopes, arising due to the extreme 10 6 :1 ratio of background beta-gamma vs. alpha radiation activity levels. This paper presents results from a novel approach to addressing this challenge, based on Tensioned Metastable Fluid Detector (TMFD) sensing technology. An acoustically driven technique was developed and tested at Purdue University (using dissolved Rn-Po and U-chain alpha emitters), and validated (with dissolved Pu) at Savannah River National Laboratory for real-time monitoring of alpha activity in the 100–10,000 dpm/mL range.

Environmental Monitoring↗

Tensioned metastable fluid detector sensing technology for multifarious-multiscale applications in the nuclear fuel cycle

The nuclear fuel cycle presents formidable 10 30+ multiscale challenges for high-efficiency spectroscopic sensing of alpha-neutron-fission radiation signatures amidst extreme gamma-beta radiation backgrounds at various stages of the cycle; it involves diverse arenas ranging from continuous/pulsed power production, security/safeguards, spent fuel, environmental remediation, and personnel health-dosimetry. This paper discusses the novel tensioned metastable fluid detector (TMFD) sensor technology. It discusses the results of studies demonstrating extreme (10 4 Sv/h) gamma-beta field blind high intrinsic efficiencies (80–100%) for neutron-alpha-fission radiation spectrometric detection. Example studies discussed in this paper include Neutron detection with spectroscopy; H*10 neutron radiation dosimetry upwards from ultra-low10 −2 µSv/h levels; Air and/or liquid-borne trace (10 –3 Bq/mL) quantity, 1 keV energy resolved alpha/fission spectroscopy for Rn/Po/U/Pu/Am environmental isotope assays at 106:1 (β:α) ratios; Directional-position enabled extended standoff tracking of neutron emitting (shielded/unshielded) special nuclear materials while stationary or moving at highway speeds; and, U.S. Department of Energy nuclear complex wide nuclear waste reprocessing, criticality safety, health physics, and environmental applications.

Alpha-fission-neutron spectrometry↗

Development, Testing, and Validation of Fabry-Pérot Cavity Acoustic Sensors for Microreactor Applications

Nuclear microreactors are a unique reactor design which may allow for the nuclear energy industry to tap into unconventional markets, and their modularity presents some advantages over larger, conventional reactor designs. For nuclear microreactors to be economically viable, on-line structural health monitoring may be necessary to reduce operation and maintenance costs with lower power production. Optical fiber sensors, and specifically optical Fabry-Pérot cavities (FPCs), may present the opportunity to monitor vibrational frequencies of microreactor components during operation, enabling identification of the location and severity of potential damage. In this work, FPCs were designed and fabricated with materials which may be able to survive in the extremely harsh environment of nuclear microreactors. The FPCs were bonded to metal test specimens to monitor their vibrational frequencies, along with a reference piezoelectric accelerometer. Euler-Bernoulli theory was used to calculate the fundamental modes and mode-shapes to compare with experimentally measured frequency spectra. The peak frequencies detected with the FPC and piezoelectric accelerometer, and theoretical modes, all agreed well for the first four fundamental modes (within 5%). Furthermore, when the FPC and accelerometer were co-located on the test specimen, their peak frequencies all agreed within 1%.

Birri, Tony↗

Extended Bandwidth Spread Spectrum Time Domain Reflectometry Cable Test for Thermal Aging, Low Resistance Fault, and Water Detection

In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Practical procedures for sensor quality assessment

Sensors are increasingly deployed for process monitoring and control. These produce on-line measurements at a high frequency, in parallel with low-frequency laboratory measurements. Compared to laboratory practices, sensor data quality assessment and control practices are far less structured at most utilities. This leads to inaccurate sensor data with unknown uncertainty factors.This chapter shows how to establish standard operating procedures (SOPs) to support sensor data quality assessment and control and subsequent maintenance actions by producing relevant sensor metadata. Furthermore, SOPs are provided for the most commonly used wastewater quality sensors, inspired by utility and academic best practices. This chapter builds on definitions provided in Chapter 3 and provides additional definitions specifically related to sensors maintenance. Chapter 6 complements the methods in this chapter, which are based on reference measurements, with data-analytical techniques.

Alferes, Janelcy↗

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantification of Hydrogen Isotopes Utilizing Raman Spectroscopy Paired with Chemometric Analysis for Application across Multiple Systems

On-line and real-time analysis of a chemical process is a major analytical challenge that can drastically change the way the chemical industry or chemical research operates. With in situ analyses, new and powerful understanding of chemistry can be gained; however, building robust tools for long-term monitoring faces many challenges that include compensating for instrument drift, instrument replacement, and sensor or probe replacement. Accounting for these changes by recollecting calibration data and rebuilding quantification models can be costly and time consuming. Here, in this study, methods to overcome these challenges are demonstrated with an application of Raman spectroscopy to monitoring hydrogen isotopes with varied speciation within dynamic gas streams. Specifically, chemical data science tools such as chemometric modeling are leveraged along with several examples of calibration transfer approaches. Furthermore, the optimization of instrument and sensors cell parameters for targeted gas phase analyses is discussed. While the particular focus on hydrogen is highly beneficial within the nuclear energy sector, mechanisms built and demonstrated here are widely applicable to optical spectroscopy monitoring in numerous other chemical systems that can be leveraged in other hazardous processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗