Search NASASearch

SEARCH · Search NASA

Results for “Open Rotors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Near wake evolution of a tidal stream turbine due to asymmetric sheared turbulent inflow with different integral length scales

Tidal stream turbines deployed at highly energetic open water sites are subjected to sheared inflow in the rotor plane. The inflow shear is expected to cause asymmetric loading on the rotor blades and affect the downstream wake. In the current study, two different turbulent inflow conditions, static-high shear and dynamic shear, were generated via an active-grid turbulence generator. A 1:20 scaled three-bladed horizontal axis tidal turbine model was tested in those conditions. The results were compared to a quasi-laminar case with no imposed turbulence or shear. The results show that the high shear reduces the average performance, with a drop of up to 16% in the optimal power coefficient. Besides, the shear profiles increase torque fluctuations and induce significant differences in wake hydrodynamics between the high-speed (upper) and low-speed (lower) regions. The large integral length scales further enhance the load fluctuations perceived by the rotor but have a negligible effect on the mean wake field quantities and the wake recovery. The lower half region featured a faster breakdown of tip vortex structure and a rapid drop of swirl number, a phenomenon conjectured to be a consequence of the strong turbulence intensities and Reynolds stresses in the lower half region. Furthermore, the sheared turbulent inflow also results in a very intensive energy redistribution process towards large-scale, low-frequency motions, which is important to the downstream turbines.

16 TIDAL AND WAVE POWER

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN

Wind Turbine Sound Setbacks and Supply Curves: Ordinances and Extrapolated Trends, 110 Hub Height, 130 Rotor Diameter

This dataset provides a comprehensive set of wind turbine sound setbacks from every residential structure in the contiguous United States (CONUS). A sound setback is defined as the minimum required distance between a residential structure and a hypothetical turbine installation site to ensure that modeled sound levels received at the residence do not exceed local sound ordinances, which are commonly expressed in A-weighted decibels (dBA). Therefore, sound setbacks are a local spatial assessment combining multiple factors, including the sound pressure curve as a function of the observer location (distance and direction) relative to the turbine, local sound regulations, and the geographical distribution of residential structures. The dataset is organized into multiple scenario-based products, detailed as follows: 1. Existing and extrapolated sound setbacks. An existing scenario characterizes sound setbacks only in states or counties that have implemented sound regulations as of 2022. The extrapolated scenarios extend a constant sound threshold to counties that lack explicit sound regulations, with thresholds ranging from 35 to 60 dBA, in 5-dBA increments reflecting the variation observed in current sound ordinances. 2. Sound setbacks in directional and worst scenarios. The directional scenario accounts for the distance and orientation of residential structures relative to a hypothetical turbine location, utilizing the turbine's sound emissions in that specific direction. In contrast, the worst scenario takes loudest sound level at each distance step from the turbine, irrespective of directional considerations, which aligns with current industry practice. 3. Supply curves for Open and Reference Access scenarios. This dataset includes supply curves generated by the reV model, which integrates each of the above sound setbacks into both Open and Reference siting scenarios. In addition, two Open and Reference baselines scenarios were included which do not consider sound setbacks for comparative analysis. All sound setback data are stored in TIF files, with partial maps of the data provided in PNG format. The values in the sound setback raster range from 0 to 1, representing the fraction of developable land within a 90 meter by 90 meter pixel due to sound ordinances. A value of 0 indicates areas where wind energy development is prohibited, while a value of 1 signifies areas fully permissible. The wind turbine parameters used in the sound modeling are based on the land-based turbine from International Energy Agency (IEA), featuring a rated electrical power of 3.4 MW, a rotor diameter of 130 meters, and a hub height of 110 meters. The atmospheric conditions, including wind speed/direction, turbulence, air temperature, relative humidity, and air pressure, that drive the sound generation are obtained from the WIND Toolkit dataset.

Array

Web-based wide-area monitoring platform for ringdown and clustering analytics in power systems

This paper introduces an open-source research platform for monitoring the Mexican interconnected power grid, allowing real-time processing and information extraction of the grid’s dynamic condition. Moreover, the platform is a Python-based development that embeds different ringdown and clustering analytics tools. In the case of ringdown analysis, the modal information can be extracted using some of the most known algorithms, i.e., Prony analysis, eigensystem realization algorithm (ERA), and matrix pencil (MP). For clustering analysis, the coherent behaviour of generator and non-generator buses is provided by applying recent state-of-the-art techniques such as affinity propagation, K-means, hierarchical agglomerative clustering, and typicality data analysis. The results of up to 93 PMUs show that this open-source platform suits researchers’ and engineers’ power system dynamic analysis requirements.

Clustering