Search NASA⌕ Search

SEARCH · Search NASA

Results for “Open path”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A new open‐path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections

Abstract Low‐power, open‐path gas sensors enable eddy covariance (EC) flux measurements in remote areas without line power. However, open‐path flux measurements are sensitive to fluctuations in air temperature, pressure, and humidity. Laser‐based, open‐path sensors with the needed sensitivity for trace gases like methane (CH 4 ) and nitrous oxide (N 2 O) are impacted by additional spectroscopic effects. Corrections for these effects, especially those related to temperature fluctuations, often exceed the flux of gases, leading to large uncertainties in the associated fluxes. For example, the density and spectroscopic corrections arising from temperature fluctuations can be one or two orders of magnitude greater than background N 2 O fluxes. Consequently, measuring background fluxes with laser‐based, open‐path sensors is extremely challenging, particularly for N 2 O and gases with similar high‐precision requirements. We demonstrate a new laser‐based, open‐path N 2 O sensor and a general approach applicable to other gases that minimizes temperature‐related corrections for EC flux measurements. The method identifies absorption lines with spectroscopic effects in the opposite direction of density effects from temperature and, thus, density and spectroscopic effects nearly cancel one another. The new open‐path N 2 O sensor was tested at a corn ( Zea mays L.) field in Southwestern Michigan, United States. The sensor had an optimal precision of 0.1 ppbv at 10 Hz and power consumption of 50 W. Field trials showed that temperature‐related corrections were 6% of density corrections, reducing EC random errors by 20‐fold compared to previously examined lines. Measured open‐path N 2 O EC fluxes showed excellent agreement with those made with static chambers ( m = 1.0 ± 0.3; r 2 = .96). More generally, we identified absorption lines for CO 2 and CH 4 flux measurements that can reduce the temperature‐related corrections by 10–100 times compared to existing open‐path sensors. The proposed method provides a new direction for future open‐path sensors, facilitating the expansion of accurate EC flux measurements.

47 OTHER INSTRUMENTATION↗

Bioaerosol Profiling with Open Path Sensors (BIOPOP) Field Campaign Report

BIOPOP, Bioaerosol Profiling with Open Path Sensors, was designed to characterize coarse and super-coarse biological aerosol particles in the atmospheric boundary layer using the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility’s tethered balloon system (TBS). The campaign period was 2025-05-28 through 2025-08-31 and involved the third ARM Mobile Facility (AMF3) operations at Bankhead National Forest (BNF) in Alabama. The analysis summarized here focuses on the June and August 2025 BNF intensive operating periods (IOPs).

54 ENVIRONMENTAL SCIENCES↗

Fugitive methane detection using open-path stand-off chirped laser dispersion spectroscopy

We report an open-path chirped laser dispersion spectrometer capable of detecting the atmospheric methane concentration above the background using both specular and diffusive reflective surfaces via two distinct operation modes in a stand-off detection configuration. The system is integrated with simultaneous ranging functionality, which enables average concentration measurements for varying optical pathlengths. The system was first tested for accuracy and characterized to achieve sensitivity of 2.9 p p m - m / H z 1 / 2 and pathlength precision of 0.2 m / H z 1 / 2 with a controlled release of methane outside the laboratory. The instrument was subsequently field-deployed in the proximity of a natural gas compressor station for fugitive methane detection. The instrument successfully detected methane plumes and narrowed down the location of the plume through multi-path measurement. The field measurements were verified by a co-located reference mobile methane sensor.

Chen, Yifeng↗

Open-path tunable diode laser absorption for eddy correlation flux measurements of atmospheric trace gases

Biogenic emissions from and dry deposition to terrestrial surfaces are important processes determining the trace gas composition of the atmosphere. An instrument has been developed for flux measurements of gases such as CH4, N2O, and O3 based on the eddy correlation technique which combines trace gas fluctuation measurements with simultaneous windfield measurements. The instrument combines a tunable diode laser infrared light source with an open-path multipass absorption cell in order to provide the fast time response and short base pathlength required for the eddy correlation method. Initial field tests using the instrument to measure methane emissions from a local wetland demonstrate the capability for high precision eddy correlation flux measurements.

Anderson, Stuart M.↗

Simultaneous in situ measurements and diurnal variations of NO, NO2, O3, jNO2, CH4, H2O, and CO2 in the 40- to 26-km region using an open path tunable diode laser spectrometer

Simultaneous in situ measurements of temperature, pressure, and the NO, NO2, O3, jNO2, CH4, H2O, and CO2 concentrations were conducted in the 40- to 26-km region of the stratosphere using the JPL Balloon-borne Laser In Situ Sensor, a tunable diode laser absorption spectrometer. The NO, NO2, CH4, H2O, and CO2 concentration measurements generally show good agreement with previous observations, with a tendency for somewhat lower NO2 amounts. Measured O3 concentrations at 38 km agree well with comparable measurements from in situ UV photometers, but at 28 km they are lower by about 10 percent and agree more closely with the solar backscattered UV data. A decline was found in NO2 during the night over a 5-km altitude range, which implies either lower NO2 postsunset profiles, or an NO2 decay rate that is significantly higher than current model predictions that use N2O5 chemistry.

Webster, Christopher R.↗

Development and Preliminary Tests of an Open-Path Airborne Diode Laser Absorption Instrument for Carbon Dioxide

Carbon dioxide (CO2) is well known for its importance as an atmospheric greenhouse gas, with many sources and sinks around the globe. Understanding the fluxes of carbon into and out of the atmosphere is a complex and daunting challenge. One tool applied by scientists to measure the vertical flux of CO2 near the surface uses the eddy covariance technique, most often from towers but also from aircraft flying specific patterns over the study area. In this technique, variations of constituents of interest are correlated with fluctuations in the local vertical wind velocity. Measurement requirements are stringent, particularly with regard to precision, sensitivity to small changes, and temporal sampling rate. In addition, many aircraft have limited payload capability, so instrument size, weight, and power consumption are also important considerations. We report on the development and preliminary application of an airborne sensor for the measurement of atmospheric CO2. The instrument, modeled on the successful DLH (Diode Laser Hygrometer) series of instruments, has been tested in the laboratory and on the NASA DC-8 aircraft. Performance parameters such as accuracy, precision, sensitivity, specificity, and temporal response are discussed in the context of typical atmospheric variability and suitability for flux measurement applications. On-aircraft, in-flight data have been obtained and are discussed as well. Performance of the instrument has been promising, and continued flight testing is planned during 2016.

Diskin, Glenn S.↗

Detecting Methane From Leaking Pipelines and as Greenhouse Gas in the Atmosphere

Laser remote sensing measurements of trace gases from orbit can provide unprecedented information about important planetary science and answer critical questions about planetary atmospheres. Methane (CH4) is the second most important anthropogenically produced greenhouse gas. Though its atmospheric abundance is much less than that of CO2 (1.78 ppm vs. 380 ppm), it has much larger greenhouse heating potential. CH4 also contributes to pollution in the lower atmosphere through chemical reactions, leading to ozone production. Atmospheric CH4 concentrations have been increasing as a result of increased fossil fuel production, rice farming, livestock, and landfills. Natural sources of CH4 include wetlands, wild fires, and termites, and perhaps other unknown sources. Important sinks for CH4 include non-saturated soils and oxidation by hydroxyl radicals in the atmosphere. Remotely measuring CH4 and other biogenic molecules (such as ethane and formaldehyde) on Mars also has important implications on the existence of life on Mars. Measuring CH4 at very low (ppb) concentrations from orbit will dramatically improve the sensitivity and spatial resolution in the search for CH4 vents and sub-surface life on other planets. A capability has been developed using lasers and spectroscopic detection techniques for the remote measurements of trace gases in open paths. Detection of CH4, CO2, H2O, and CO in absorption cells and in open paths, both in the mid- IR and near-IR region, has been demonstrated using an Optical Parametric Amplifier laser transmitter developed at GSFC. With this transmitter, it would be possible to develop a remote sensing methane instrument. CH4 detection also has very important commercial applications. Pipeline leak detection from an aircraft or a helicopter can significantly reduce cost, response time, and pinpoint the location. The main advantage is the ability to rapidly detect CH4 leaks remotely. This is extremely important for the petrochemical industry. This capability can be used in manned or unmanned airborne platforms for the detection of leaks in pipelines and other areas of interest where a CH4 leak is suspected.

Riris, Haris↗

Ring-Opening Dynamics of the Cyclopropyl Radical and Cation: the Transition State Nature of the Cyclopropyl Cation

Here, we provide compelling experimental and theoretical evidence for the transition state nature of the cyclopropyl cation. Synchrotron photoionization spectroscopy employing coincidence techniques together with a novel simulation based on high-accuracy ab initio calculations reveal that the cation is unstable via its allowed disrotatory ring-opening path. The ring strains of the cation and the radical are similar, but both ring opening paths for the radical are forbidden when the full electronic symmetries are considered. These findings are discussed in light of the early predictions by Longuet-Higgins alongside Woodward and Hoffman; we also propose a simple phase space explanation for the appearance of the cyclopropyl photoionization spectrum. The results of this work allow the refinement of the cyclopropane C–H bond dissociation energy, in addition to the cyclopropyl radical and cation cyclization energies, via the Active Thermochemical Tables approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Miniature Tunable Laser Spectrometer for Detection of a Trace Gas

An open-path laser spectrometer (OPLS) for measuring a concentration of a trace gas, the OPLS including an open-path multi-pass analysis region including a first mirror, a second mirror at a distance and orientation from the first mirror, and a support structure for locating the mirrors, a laser coupled to the analysis region and configured to emit light of a wavelength range and to enable a plurality of reflections of the emitted light between the mirrors, a detector coupled to the analysis region and configured to detect a portion of the emitted light impinging on the detector and to generate a corresponding signal, and an electronic system coupled to the laser and the detector, and configured to adjust the wavelength range of the emitted light from the laser based on the generated signal, and to measure the concentration of the trace gas based on the generated signal.

Christensen, Lance E.↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

Trace Gas Measurements on Mars and Earth Using Optical Parametric Generation

Trace gases and their isotopic ratios in planetary atmospheres offer important but subtle clues as to the origins of a planet's atmosphere, hydrology, geology, and potential for biology. An orbiting laser remote sensing instrument is capable of measuring trace gases on a global scale with unprecedented accuracy, and higher spatial resolution that can be obtained by passive instruments. We have developed an active sensing instrument for the remote measurement of trace gases in planetary atmospheres (including Earth). The technique uses widely tunable, seeded optical parametric generation (OPG) to measure methane, CO2, water vapor, and other trace gases in the near and mid-infrared spectral regions. Methane is a strong greenhouse gas on Earth and it is also a potential biogenic marker on Mars and other planets. Methane in the Earth's atmosphere survives for a shorter time than CO2 but its impact on climate change can be larger than CO2. Methane levels have remained relatively constant over the last decade around 1.78 parts per million (ppm) but recent observations indicate that methane levels may be on the rise. Increasing methane concentrations may trigger a positive feedback loop and a subsequent runaway greenhouse effect, where increasing temperatures result in increasing methane levels. The NRC Decadal Survey recognized the importance of global observations of greenhouse gases and called for simultaneous CH4, CO, and CO2 measurements but also underlined the technological limitations for these observations. For Mars, methane measurements are of great interest because of its potential as a strong biogenic marker. A remote sensing instrument that can measure day and night over all seasons and latitudes can identify and localize sources of biogenic gas plumes produced by subsurface chemistry or biology, and aid in the search for extra-terrestrial life. It can identify the dynamics of methane generation over time and latitude and identify future lander mission sites for more detailed in-situ analysis. In this paper we report on remote sensing measurements of methane using a high peak power, widely tunable optical parametric generator (OPG) operating at 3.3 micron and 1.65 micron. The OPG is pumped by a passively q-switched single frequency laser (3ns, 5KHz, 50uJ) and seeded by a diode laser. The spectral width of both signal and idler of seeded OPG is nearly Fourier transform limited. The output of seeded OPG is single frequency with high spectral purity and is widely tunable. Both 1650 nm and 3300 nm can be generated with a conversion efficiency of more than 30%. We have demonstrated detection of methane at 3274 nm and 1650 nm in a cell and also performed open path atmospheric measurements of methane at the same wavelengths. Finally, we were able to demonstrate simultaneous detection of methane at 3270.4 nm and CO2 at 1578.2 nm. In this paper we will discuss the OPG performance and atmospheric open path measurement results.

Numata, Kenji↗

Uncertainties in turbulent statistics and fluxes of CO2 associated with density effect corrections

Density effect corrections (DEC) are applied to adjust raw CO2 fluxes measured by eddy covariance (EC) systems with open-path gas analyzers. DEC is also required for adjusting the measured CO2 concentration fluctuations to obtain the adjusted CO2 for analyzing turbulent statistics or quantifying fluxes. However, our data show that the power spectra of the DEC-adjusted CO2 are distorted in the high frequency range, as compared with the corresponding spectra of temperature and water vapor density. This contradicts the similarity behavior of scalars, as suggested by Monin-Obukhov similarity theory. It is demonstrated that such a distortion is caused by the DEC-induced spikes in the DEC-adjusted CO2, altering turbulent statistics of CO2 and scalar similarity between CO2 and other scalars. Our results suggest that CO2 fluxes are overestimated by applying DEC especially under high Bowen ratio conditions, potentially leading to substantial uncertainties in long-term ecosystem carbon exchange in dry regions.

Gao, Zhongming↗

Integrated Methane Monitoring Platform Design

This report presents design plans for integrated methane monitoring platforms for the oil and gas sector, which include satellites, aircrafts, drones, mobile platforms, open-path systems, sensor networks, LDAR techniques, and other systems.

03 NATURAL GAS↗