A new open‐path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections

Abstract Low‐power, open‐path gas sensors enable eddy covariance (EC) flux measurements in remote areas without line power. However, open‐path flux measurements are sensitive to fluctuations in air temperature, pressure, and humidity. Laser‐based, open‐path sensors with the needed sensitivity for trace gases like methane (CH 4 ) and nitrous oxide (N 2 O) are impacted by additional spectroscopic effects. Corrections for these effects, especially those related to temperature fluctuations, often exceed the flux of gases, leading to large uncertainties in the associated fluxes. For example, the density and spectroscopic corrections arising from temperature fluctuations can be one or two orders of magnitude greater than background N 2 O fluxes. Consequently, measuring background fluxes with laser‐based, open‐path sensors is extremely challenging, particularly for N 2 O and gases with similar high‐precision requirements. We demonstrate a new laser‐based, open‐path N 2 O sensor and a general approach applicable to other gases that minimizes temperature‐related corrections for EC flux measurements. The method identifies absorption lines with spectroscopic effects in the opposite direction of density effects from temperature and, thus, density and spectroscopic effects nearly cancel one another. The new open‐path N 2 O sensor was tested at a corn ( Zea mays L.) field in Southwestern Michigan, United States. The sensor had an optimal precision of 0.1 ppbv at 10 Hz and power consumption of 50 W. Field trials showed that temperature‐related corrections were 6% of density corrections, reducing EC random errors by 20‐fold compared to previously examined lines. Measured open‐path N 2 O EC fluxes showed excellent agreement with those made with static chambers ( m = 1.0 ± 0.3; r 2 = .96). More generally, we identified absorption lines for CO 2 and CH 4 flux measurements that can reduce the temperature‐related corrections by 10–100 times compared to existing open‐path sensors. The proposed method provides a new direction for future open‐path sensors, facilitating the expansion of accurate EC flux measurements.

47 OTHER INSTRUMENTATION↗

Bioaerosol Profiling with Open Path Sensors (BIOPOP) Field Campaign Report

BIOPOP, Bioaerosol Profiling with Open Path Sensors, was designed to characterize coarse and super-coarse biological aerosol particles in the atmospheric boundary layer using the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility’s tethered balloon system (TBS). The campaign period was 2025-05-28 through 2025-08-31 and involved the third ARM Mobile Facility (AMF3) operations at Bankhead National Forest (BNF) in Alabama. The analysis summarized here focuses on the June and August 2025 BNF intensive operating periods (IOPs).

54 ENVIRONMENTAL SCIENCES↗

Fugitive methane detection using open-path stand-off chirped laser dispersion spectroscopy

We report an open-path chirped laser dispersion spectrometer capable of detecting the atmospheric methane concentration above the background using both specular and diffusive reflective surfaces via two distinct operation modes in a stand-off detection configuration. The system is integrated with simultaneous ranging functionality, which enables average concentration measurements for varying optical pathlengths. The system was first tested for accuracy and characterized to achieve sensitivity of 2.9 p p m - m / H z 1 / 2 and pathlength precision of 0.2 m / H z 1 / 2 with a controlled release of methane outside the laboratory. The instrument was subsequently field-deployed in the proximity of a natural gas compressor station for fugitive methane detection. The instrument successfully detected methane plumes and narrowed down the location of the plume through multi-path measurement. The field measurements were verified by a co-located reference mobile methane sensor.

Chen, Yifeng↗

Ring-Opening Dynamics of the Cyclopropyl Radical and Cation: the Transition State Nature of the Cyclopropyl Cation

Here, we provide compelling experimental and theoretical evidence for the transition state nature of the cyclopropyl cation. Synchrotron photoionization spectroscopy employing coincidence techniques together with a novel simulation based on high-accuracy ab initio calculations reveal that the cation is unstable via its allowed disrotatory ring-opening path. The ring strains of the cation and the radical are similar, but both ring opening paths for the radical are forbidden when the full electronic symmetries are considered. These findings are discussed in light of the early predictions by Longuet-Higgins alongside Woodward and Hoffman; we also propose a simple phase space explanation for the appearance of the cyclopropyl photoionization spectrum. The results of this work allow the refinement of the cyclopropane C–H bond dissociation energy, in addition to the cyclopropyl radical and cation cyclization energies, via the Active Thermochemical Tables approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

Uncertainties in turbulent statistics and fluxes of CO2 associated with density effect corrections

Density effect corrections (DEC) are applied to adjust raw CO2 fluxes measured by eddy covariance (EC) systems with open-path gas analyzers. DEC is also required for adjusting the measured CO2 concentration fluctuations to obtain the adjusted CO2 for analyzing turbulent statistics or quantifying fluxes. However, our data show that the power spectra of the DEC-adjusted CO2 are distorted in the high frequency range, as compared with the corresponding spectra of temperature and water vapor density. This contradicts the similarity behavior of scalars, as suggested by Monin-Obukhov similarity theory. It is demonstrated that such a distortion is caused by the DEC-induced spikes in the DEC-adjusted CO2, altering turbulent statistics of CO2 and scalar similarity between CO2 and other scalars. Our results suggest that CO2 fluxes are overestimated by applying DEC especially under high Bowen ratio conditions, potentially leading to substantial uncertainties in long-term ecosystem carbon exchange in dry regions.

Gao, Zhongming↗

Integrated Methane Monitoring Platform Design

This report presents design plans for integrated methane monitoring platforms for the oil and gas sector, which include satellites, aircrafts, drones, mobile platforms, open-path systems, sensor networks, LDAR techniques, and other systems.

03 NATURAL GAS↗

OpenET: Filling a Critical Data Gap in Water Management for the Western United States

The lack of consistent, accurate information on evapotranspiration (ET) and consumptive use of water by irrigated agriculture is one of the most important data gaps for water managers in the western United States (U.S.) and other arid agricultural regions globally. The ability to easily access information on ET is central to improving water budgets across the West, advancing the use of data-driven irrigation management strategies, and expanding incentive-driven conservation programs. Recent advances in remote sensing of ET have led to the development of multiple approaches for field-scale ET mapping that have been used for local and regional water resource management applications by U.S. state and federal agencies. The OpenET project is a community-driven effort that is building upon these advances to develop an operational system for generating and distributing ET data at a field scale using an ensemble of six well-established satellite-based approaches for mapping ET. Key objectives of OpenET include: Increasing access to remotely sensed ET data through a web-based data explorer and data services; supporting the use of ET data for a range of water resource management applications; and development of use cases and training resources for agricultural producers and water resource managers. Here we describe the OpenET framework, including the models used in the ensemble, the satellite, meteorological, and ancillary data inputs to the system, and the OpenET data visualization and access tools. We also summarize an extensive intercomparison and accuracy assessment conducted using ground measurements of ET from 139 flux tower sites instrumented with open path eddy covariance systems. Results calculated for 24 cropland sites from Phase I of the intercomparison and accuracy assessment demonstrate strong agreement between the satellite-driven ET models and the flux tower ET data. For the six models that have been evaluated to date (ALEXI/DisALEXI, eeMETRIC, geeSEBAL, PT-JPL, SIMS, and SSEBop) and the ensemble mean, the weighted average mean absolute error (MAE) values across all sites range from 13.6 to 21.6 mm/month at a monthly timestep, and 0.74 to 1.07 mm/day at a daily timestep. At seasonal time scales, for all but one of the models the weighted mean total ET is within ±8% of both the ensemble mean and the weighted mean total ET calculated from the flux tower data. Overall, the ensemble mean performs as well as any individual model across nearly all accuracy statistics for croplands, though some individual models may perform better for specific sites and regions. We conclude with three brief use cases to illustrate current applications and benefits of increased access to ET data, and discuss key lessons learned from the development of OpenET.

54 ENVIRONMENTAL SCIENCES↗

The carbon-concentrating mechanism of the extremophilic red microalga Cyanidioschyzon merolae

Abstract Cyanidioschyzon merolae is an extremophilic red microalga which grows in low-pH, high-temperature environments. The basis of C. merolae ’s environmental resilience is not fully characterized, including whether this alga uses a carbon-concentrating mechanism (CCM). To determine if C. merolae uses a CCM, we measured CO 2 uptake parameters using an open-path infra-red gas analyzer and compared them to values expected in the absence of a CCM. These measurements and analysis indicated that C. merolae had the gas-exchange characteristics of a CCM-operating organism: low CO 2 compensation point, high affinity for external CO 2 , and minimized rubisco oxygenation. The biomass δ 13 C of C. merolae was also consistent with a CCM. The apparent presence of a CCM in C. merolae suggests the use of an unusual mechanism for carbon concentration, as C. merolae is thought to lack a pyrenoid and gas-exchange measurements indicated that C. merolae primarily takes up inorganic carbon as carbon dioxide, rather than bicarbonate. We use homology to known CCM components to propose a model of a pH-gradient-based CCM, and we discuss how this CCM can be further investigated.

60 APPLIED LIFE SCIENCES↗

The effect of relative humidity on eddy covariance latent heat flux measurements and its implication for partitioning into transpiration and evaporation

While the eddy covariance (EC) technique is a well-established method for measuring water fluxes (i.e., evaporation or 'evapotranspiration’, ET), the measurement is susceptible to many uncertainties. One such issue is the potential underestimation of ET when relative humidity (RH) is high (> 70%), due to low-pass filtering with some EC systems. Yet, this underestimation for different types of EC systems (e.g. open-path or closed-path sensors) has not been characterized for synthesis datasets such as the widely used FLUXNET2015 dataset. Here, we assess the RH-associated underestimation of latent heat fluxes (LE, or ET) from different EC systems for 163 sites in the FLUXNET2015 dataset. We found that the LE underestimation is most apparent during hours when RH is higher than 70%, predominantly observed at sites using closed-path EC systems, but the extent of the LE underestimation is highly site-specific. We then propose a machine learning based method to correct for this underestimation, and compare it to two energy balance closure based LE correction approaches (Bowen ratio correction, BRC, and attributing all errors to LE). Our correction increases LE by 189% for closed-path sites at high RH (> 90%), while BRC increases LE by around 30% for all RH conditions. Additionally, we assess the influence of these corrections on ET-based transpiration (T) estimates using two different ET partitioning methods. Results show opposite responses (increasing vs. slightly decreasing T-to-ET ratios, T/ET) between the two methods when comparing T based on corrected and uncorrected LE. Overall, our results demonstrate the existence of a high RH bias in water fluxes in the FLUXNET2015 dataset and suggest that this bias is a pronounced source of uncertainty in ET measurements to be considered when estimating ecosystem T/ET and WUE.

54 ENVIRONMENTAL SCIENCES↗

Application of emerging monitoring techniques at the Illinois Basin – Decatur Project

The Illinois Basin – Decatur Project is a large-scale carbon capture and storage demonstration project located in Decatur, Illinois, USA. In this project, one million metric tons of carbon dioxide (CO 2 ) was captured from an ethanol production facility and successfully injected into a deep saline reservoir over a period of three years. The scale of this project presented an opportunity to explore emerging technologies for effective long-term monitoring of the carbon capture and storage site. This research documents the application of three emerging monitoring techniques: (1) a prototype “open-path” sensor, a method of continuously monitoring atmospheric CO 2 by applying tunable diode laser absorption spectroscopy to provide a warning system for personnel safety along pipelines and at wellheads; (2) the Greenhouse Gas Laser Imaging Tomography Experiment (GreenLITE), an automated system for measuring two-dimensional spatial distribution of atmospheric CO 2 concentrations; and (3) periodic aerial imagery, a method of documenting surface-vegetation dynamics to detect vegetative responses to CO 2 leaks. The objective of this work was to assess the advantages and limitations of these monitoring techniques and quantify their reliability over an extended deployment at an active industrial site. These results will aid in determining viability of long-term monitoring on a commercial scale.

42 ENGINEERING↗

Controlling the helicity of light by electrical magnetization switching

Controlling the intensity of emitted light and charge current is the basis of transferring and processing information. By contrast, robust information storage and magnetic random-access memories are implemented using the spin of the carrier and the associated magnetization in ferromagnets. In this study, the missing link between the respective disciplines of photonics, electronics and spintronics is to modulate the circular polarization of the emitted light, rather than its intensity, by electrically controlled magnetization. Here we demonstrate that this missing link is established at room temperature and zero applied magnetic field in light-emitting diodes through the transfer of angular momentum between photons, electrons and ferromagnets. With spin-orbit torque a charge current generates also a spin current to electrically switch the magnetization. This switching determines the spin orientation of injected carriers into semiconductors, in which the transfer of angular momentum from the electron spin to photon controls the circular polarization of the emitted light. The spin-photon conversion with the nonvolatile control of magnetization opens paths to seamlessly integrate information transfer, processing and storage. Our results provide substantial advances towards electrically controlled ultrafast modulation of circular polarization and spin injection with magnetization dynamics for the next-generation information and communication technology, including space-light data transfer. The same operating principle in scaled-down structures or using two-dimensional materials will enable transformative opportunities for quantum information processing with spin-controlled single-photon sources, as well as for implementing spin-dependent time-resolved spectroscopies.

74 ATOMIC AND MOLECULAR PHYSICS↗

Get on the BAND Wagon: a Bayesian framework for quantifying model uncertainties in nuclear dynamics

In this paper, we describe the Bayesian Analysis of Nuclear Dynamics (BAND) framework, a cyberinfrastructure that we are developing which will unify the treatment of nuclear models, experimental data, and associated uncertainties. We overview the statistical principles and nuclear-physics contexts underlying the BAND toolset, with an emphasis on Bayesian methodology's ability to leverage insight from multiple models. In order to facilitate understanding of these tools we provide a simple and accessible example of the BAND framework's application. Four case studies are presented to highlight how elements of the framework will enable progress on complex, far-ranging problems in nuclear physics. By collecting notation and terminology, providing illustrative examples, and giving an overview of the associated techniques, this paper aims to open paths through which the nuclear physics and statistics communities can contribute to and build upon the BAND framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CROCUS High-Frequency Measurements of CO₂, H₂O, Wind, and Temperature at University of Illinois Chicago

As of April 9, 2026: this dataset is currently being versioned to include data up to March 31, 2026. Once the versioning process is complete, new data files will be available for access. The dataset metadata will also be updated to reflect the data availability of the new data being versioned. Raw atmospheric measurements collected at the University of Illinois Chicago (UIC) as part of the Community Research on Climate and Urban Science (CROCUS) project. The data includes high-frequency measurements of carbon dioxide (CO₂) concentration, water vapor (H₂O) concentration, wind speed (U, V, W components), temperature, and atmospheric pressure. These raw data are recorded by the LI-7500DS Open Path CO₂/H₂O Analyzer and a sonic anemometer at a 10 Hz acquisition frequency, providing the necessary inputs for calculating fluxes of CO₂, H₂O, heat, and momentum. In addition to gas concentration measurements, the dataset includes diagnostic information from the instruments, including absorptance, sample and reference signals, and diagnostic values. The data were collected to study urban atmospheric conditions and contribute to flux calculations for urban climate research. These measurements form the basis for calculating 30-minute average fluxes of key atmospheric variables using the eddy covariance method. This dataset provides critical raw input data for researchers interested in atmospheric fluxes, urban air quality, and the interaction between the urban environment and atmospheric processes. The data is part of the U.S. Department of Energy’s Biological and Environmental Research (BER) program, under the CROCUS Urban Integrated Field Laboratory (UIFL) project.

54 ENVIRONMENTAL SCIENCES↗

AmeriFlux FLUXNET-1F CA-SCB Scotty Creek Bog

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-SCB Scotty Creek Bog. This is the FLUXNET version of the carbon flux data for the site CA-SCB Scotty Creek Bog produced by applying the standard ONEFlux (1F) software. Site Description - The Scotty Creek bog flux tower is located in an organic-rich collapse-scar bog about 50 km south of Fort Simpson in the Taiga Plains of the Mackenzie watershed. The tower was installed in 2014 and operates an open-path EC system year-round running on solar power only. The collapse-scar bog is treeless and free of permafrost.

Sonnentag, Oliver↗

AmeriFlux FLUXNET-1F CA-SCC Scotty Creek Landscape

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-SCC Scotty Creek Landscape. This is the FLUXNET version of the carbon flux data for the site CA-SCC Scotty Creek Landscape produced by applying the standard ONEFlux (1F) software. Site Description - The Scotty Creek flux tower is located in an organic-rich boreal forest-wetland landscape about 50 km south of Fort Simpson in the Taiga Plains of the Mackenzie watershed. The tower was installed in 2013 and operates an open-path EC system year-round running on solar power only. Flux footprints contain about 50 % forested peat plateaus and 50 % wetlands (i.e., collapse-scar bogs). The forests are underlain by permafrost, while the treeless wetlands are permafrost-free. The tower itself is located on a forested peat plateau. Black spruce tree density on plateaus is sparse and the mean canopy height is ca. 5 m.

Sonnentag, Oliver↗