Search NASASearch

SEARCH · Search NASA

Results for “OpenSim”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Adjusting a Full Body Model to Mitigate Inverse Kinematics Artifacts in Opensim

BACKGROUND: In support of Vibration Isolation and Stabilization (VIS) system development for Human Health Countermeasures (HHC) exercise systems in space, such as the European Enhanced Exploration Exercise Device (E4D) [1], dynamic quantities required to model the response of a proposed VIS while considering the effect of VIS motion on the forces between the human and VIS platform were obtained using motion capture data [2]. On occasion, large-amplitude oscillatory spikes were found in the subject’s linear and angular momentum derivatives, affecting analyses that depend on forces and moments derived from motion capture. The purpose of this investigation was to identify causes of these artifacts and techniques for their resolution. METHODS AND RESULTS: To obtain the required human dynamic quantities to drive the VIS simulation, motion capture data was collected containing recorded trajectories of passive retroreflective markers on body landmarks of an exercising subject. Since the full body Rajagopal model [3] was originally used to enhance gait analysis, upper body joints did not require large Ranges of Motion (ROM). We thus modified the Rajagopal model [4, 5] to allow it to be used for upper body intensive exercises like those common to the E4D. OpenSim Inverse Kinematics (IK) [6] was performed using these scaled subject models to generate the joint angles throughout the exercise while minimizing marker error. At times, the arms were observed to ‘snap’ from one configuration to another, causing spike artifacts. Following IK, a custom OpenSim plugin [7] was used to determine the required dynamic quantities including the rates of change of the linear and angular momenta of the human. Since motion capture is recorded at a larger time step than required by the VIS simulation, the human center of mass location was fit with splines and a second derivative taken to obtain the momentum derivative, allowing the VIS simulation to maintain conservation of momentum when appropriate. In a few cases during this stage, artifacts much larger than the expected noise of the second derivatives were introduced. Investigation of cases containing artifacts revealed several modifications that could be made to the OpenSim model to improve IK results. Since OpenSim models use Euler angles and rotation sequences, ‘gimbal lock’ would be encountered in the arms when raised 90 degrees to the side (e.g., T-pose, some hang clean exercise, etc.). This was resolved by reorienting the horizontal axes at the shoulder joint by 45 degrees, placing ‘gimbal lock’ outside common arm ROM, with the arm ROMs adjusted following this change. Elbow and wrist ROMs could also be adjusted to allow realistic motion while at the same time limiting the likelihood of unrealistic orientations. On occasion, the arms flipped backwards when raised above the head. This was prevented by using medial elbow markers in scaling and IK. When medial markers were not available, the acromial joint location in the unscaled model was shifted before model scaling to better align the arm with available markers. Lastly, artifacts which became apparent after taking the second derivatives of spline-fit data were found to occur in cases when the pelvis rotation limit prevented the full range of motion of an exercise. These issues were resolved by unclamping the pelvis rotation limit. Through this investigation, an understanding of conditions leading to IK artifacts was acquired allowing the automation of artifact detection. These artifact detection and mitigation techniques can be applied toward modeling of upper body motions in aerospace and other fields for improved IK results.

C A Bell

Recent Improvements and Verification of A Full Body Model in Opensim

BACKGROUND: The dynamic feasibility [1,2] criterion, that the subject’s Center of Pressure (COP) be located within the Base of Support (BOS) which outlines the feet, has aided in assessing the stability of human motion recorded on earth while performing the recorded tasks in lunar gravity or as countermeasures exercises on a vibration isolation and stabilization system in microgravity. The convex hull of the BOS on the platform under the subject’s feet was estimated using virtual markers on the feet of the scaled subject model. The COP was calculated using the ground reaction forces and moments determined from motion capture data with biomechanical modeling tools [3]. Occasionally, large-amplitude oscillatory spikes or “artifacts” were observed in the subject’s linear and angular momentum derivatives, affecting some COP data derived from motion capture. The purpose of this investigation was to assess and improve the accuracy of model scaling and BOS estimation as well as to determine the efficacy of model adjustments in mitigating artifacts influencing motion capture-derived ground reaction force and COP results. METHODS: To aid evaluation of proposed process and model updates, motion capture data were collected for two subjects during unit test and range of motion trials, lunar tasks, and countermeasures exercise motions. Markers were added to the full body Plug-in Gait marker set [4] during data collection. New markers were placed on the front, back, sides, and top of the head to improve scaling using distances between marker pairs. Medial elbow markers were added to stabilize the upper arm during OpenSim Inverse Kinematics (IK) [5]. Finally, markers were added on the outer edge of the heels and on the outside edges of the first and last toes on each foot. These additional foot markers were made available to test new automated foot scaling techniques and to calculate the error between the subject’s estimated and recorded BOS. The modified unscaled OpenSim Full Body Rajagopal Model [6,7] was adjusted using some previously investigated techniques [8] to mitigate rapid shifts in joint angles occurring during IK, as these were found to cause the spike artifacts observed in subsequent stages of analysis. Since OpenSim models use Euler angles and rotation sequences, the arm axes of rotation were adjusted, and the pelvis order of rotation was changed to minimize the likelihood of encountering “gimbal lock” during common human motion. The model clavicle, arm, elbow, wrist, pelvis, and ankle angle limits were adjusted to better accommodate the full human range of motion seen in exercise and lunar data. The shoulder joint center was calculated using a “pivoting” algorithm [9], and both shoulder joint center and upper arm markers were included during IK to provide additional shoulder stability on a case-by-case basis. The quality of IK results was assessed by three criteria: minimizing error between recorded motion capture markers and model markers, checking for reasonable rates of change in joint angles between fames (i.e., no IK artifacts), and ensuring the absence of spikes in the inertial forces and angular momentum derivatives calculated using a custom OpenSim plugin [10]. RESULTS: The additional markers placed on the subject during data collection allowed the head and feet to be scaled more accurately using distances between new marker pairs. Scaling with BOS markers placed on the subject and removing the limit on subtalar angle resulted in more accurate BOS determination. Unrealistically large changes in joint angles between frames could be reduced by including clavicle, sternum, and medial elbow markers during IK. In cases with large arm ranges of motion, results could be further improved by running IK using medial elbow and virtual shoulder joint center markers. Model adjustments significantly improved the IK results affecting COP calculation and increased the accuracy of BOS estimation.

C A Bell

Computational Modeling Using OpenSim to Simulate a Squat Exercise Motion

Long duration space travel to destinations such as Mars or an asteroid will expose astronauts to extended periods of reduced gravity. Astronauts will use an exercise regime for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Since the area available in the spacecraft for an exercise device is limited and gravity is not present to aid loading, compact resistance exercise device prototypes are being developed. Since it is difficult to rigorously test these proposed devices in space flight, computational modeling provides an estimation of the muscle forces, joint torques and joint loads during exercise to gain insight on the efficacy to protect the musculoskeletal health of astronauts.

Human Factors Engineering

OpenSim Model Improvements to Support High Joint Angle Resistive Exercising

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Rigorous testing of these proposed devices in space flight is difficult so computational modeling provides an estimation of the muscle forces and joint loads during exercise to gain insight on the efficacy to protect the musculoskeletal health of astronauts. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts

Bioengineering

Implicit Formulation of Muscle Dynamics in OpenSim

Astronauts lose bone and muscle mass during spaceflight. Exercise countermeasure is the primary method for counteracting bone and muscle mass loss in space. New spacecraft exercise device concepts are currently being developed for the NASAs new crew exploration vehicle. The NASA Digital Astronaut Project (DAP) uses computational modeling to help determine if the new exercise devices will be effective as countermeasures. The NASA Digital Astronaut Project is developing the ability to utilize predictive simulation to provide insight into the change in kinematics and kinetics with a change in device and gravitational environment (1-g versus 0-g). For example, in space exercise the subject's body weight is applied in addition to the loads prescribed for musculoskeletal maintenance. How and where these loads are applied obviously directly impacts bone and tissue loads. Additionally, due to space vehicle structural requirements, exercise devices are often placed on vibration isolation systems. This changes the apparent impedance or stiffness of the device as seen by the user. Data collection under these conditions is often impractical and limited. Predictive modeling provides a means to have a virtual subject to test hypotheses. Predictive simulation provides a virtual subject for which we are able to perform studies such as sensitivity to device loading and vibration isolation without the need for laboratory kinematic or kinetic test data.Direct Collocation optimization provides an efficient means to perform task based optimization and predictive modeling. It is relatively straight forward to structure a physical exercise task in a Direct Collocation mathematical formulation: perform a motion such that you start at an initial pose, achieve a given amount of deflection i.e a squat, return to the initial pose, and minimize muscle activation cost. Direct Collocation is advantageous in that it does not require numerical integration to evaluate the objective function. Instead, the system dynamics are transformed to discrete time and the optimizer is constrained such that the solution is not considered to be a valid unless the dynamic equations are satisfied at all time points. The simulation and optimization are effectively done simultaneously. Due to the implicit integration, time steps can be more coarse than in a differential equation solver. In a gait scenario this means that that the model constraints and cost function are evaluated at 100 nodes in the gait cycle versus 10,000 integration steps in a variable-step forward dynamic simulation. Furthermore, no time is wasted on accurate simulations of movements that are far from the optimum. Constrained optimization algorithms require a Jacobian matrix that contains the partial derivatives of each of the dynamic constraints with respect to of each of the state and control variables at all time points. This is a large but sparse matrix. An implicit dynamics formulation requires computation of the dynamic residuals f as a function of the states x and their derivatives, and controls u:f(x, dxdt, u) 0If the dynamics of musculoskeletal system are formulated implicitly, the Jacobian elements are often available analytically, eliminating the need for numerical differentiation; this is obviously computationally advantageous. Additionally, implicit formulation of musculoskeletal dynamics do not suffer from singularities from low mass bodies, zero muscle activation, or other stiff system or

physical exercise

Predictive Kinematic Analysis Methodologies for Use with OpenSim

This report focuses specifically on the development of a methodology to generate predictive kinematics in the absence of measured test data or the ability to test in the microgravity environment. The customer for this deliverable is the AEC project.

Computer models

Comparing Theoretically Scaled Biomechanical Models

BACKGROUND An investigation into incorporating space suit aspects required a 50th-percentile male model which was not part of the existing dataset of models. Previously, theoretical models for 5th-percentile female and 95th-percentile male were created utilizing a scaled test subject as close as possible to the target height and weight. Scaling factors were created by taking the height ratio and applying it uniformly to the model body segments, then fine tuning to ensure the theoretical model’s height is as expected. This study was initiated to examine the existing method of isometrically scaling in OpenSim [1,2] and to create alternative methods which do not rely on an existing subject being close in height and weight to the theoretical model of interest. Generating a theoretical biomechanical model provides additional abilities without the reliance on available OpenSim models or real subjects. Gained abilities include creating different percentile models and attaining representative anthropometry for any target height/weight, such as targeting specific crew populations or gaps within the current dataset. METHODS AND RESULTS This study includes 3 methods for generating the theoretical model; utilizing the modified unscaled OpenSim Full Body Rajagopal Model (FBRM) [3,4], a dataset of scaled OpenSim models, and existing scaling factors from Dumas et al. [5]. All methods use the Anthropometric Survey of US Army Personnel (ANSUR II) [6] as an input of necessary anthropometric measurements. The following measurements are retrieved from the ANSUR II collection: mass, stature, cervicale height, acromial height, axilla height, waist height, trochanterion height, lateral femoral epicondyle height, lateral malleolus height, acromion-radiale length, radiale-stylion length, palm length, ball of foot length, bicristal breadth, bimalleolar breadth. Some of the measurements are direct segment lengths and others are utilized to derive segment lengths. Height, weight, and age ranges are the required inputs to parse the collection for a mean value of the measurements. A simple iterative process may be necessary for the output of mean mass and stature consistent with the theoretical model of interest. In some cases, one may specify exact values instead of a range but that is dependent upon whether those exact values pertain to a single subject from the ANSUR II collection. Equations from Dumas et al. were used to calculate scaling factors for the two methods that utilize OpenSim scaled and unscaled models. In the third method, Dumas’ scaling factors were used directly instead of generating our own. After scaling factors are achieved, they are applied along with the mass and segment lengths retrieved from ANSUR II in order to calculate the segment mass, Center of Mass (CoM), mass Moment of Inertia (MoI), and the joint location in the parent frame. The theoretical models from the different methods were compared to the previous existing method of isometrically scaling in OpenSim, as well as the standards found in NASA STD-3000 [7] and the NASA Human Integration Design Handbook [8]. The whole-body center of mass is the main comparison performed between the models and the standards. The body segment mass properties were also compared when possible. In some cases, the standards do not provide complete data, or the center of mass location is not provided with respect to the appropriate joint coordinate system. For a 50th-percentile male subject, results from isometric scaling in OpenSim and the method utilizing the unscaled FBRM were compared to the standards in NASA STD-3000. According to the standard, the whole-body vertical CoM location was taken from the head vertex to the CoM. The standards provide 80.2 cm for the CoM vertical component whereas isometric scaling in OpenSim and utilizing the unscaled FBRM provide 82.2 and 82.3 cm, respectively. Through definition, the whole-body CoM in the medial/lateral direction agreed across the models. Investigation is on-going to clearly identify the reference point pertaining to dorsal/ventral whole-body CoM position in standards and relate that to the theoretical models. REFERENCES [1] Delp, S.L., et al., “OpenSim: Open-source Software to Create and Analyze Dynamic Simulations of Movement”, IEEE Transactions on Biomedical Engineering, (2007). [2] Seth, A., Hicks J.L., Uchida, T.K., Habib, A., Dembia, C.L., Dunne, J.J., Ong, C.F., DeMers, M.S., Rajagopal, A., Millard, M., Hamner, S.R., Arnold, E.M., Yong, J.R., Lakshmikanth, S.K., Sherman,n M.A., Delp, S.L. OpenSim: Simulating musculoskeletal dynamics and neuromuscular control to study human and animal movement. Plos Computational Biology, 14(7). (2018) [3] R. K. Huffman, W. K. Thompson, C. A. Gallo, L. J. Quiocho, “Improvement of Scaling and Inverse Kinematic Results with Additional Upper Body Joints Added to Opensim Rajagopal Model”, NASA Human Research Program Investigator’s Workshop, (2019). [4] Huffman R.K., Thompson W., Gallo C., “Modified OpenSim Rajagopal Full Body Model”, New Technology Report, MSC-26872-1. (August 2020). [5] Dumas R., Cheze L. and Verriest J., 2007. “Adjustments to McConville et al. and Young et al. body segment inertial parameters”. Journal of Biomechanics 40, pp. 543-553 [6] Gordon C.C., 2012 “Anthropometric Survey of U.S. Army Personnel: Methods and Summary Statistics”, US Army Natick Soldier RD&E Center. [7] NASA STD-3000/REV-B, 1995. “The Man-System Integration Standards” [8] NASA/SP-2010-3407/REV-1, 2014. “The Human Integration Design Handbook (HIDH)”

F N Matari

Biomechanical Modeling Analysis of Loads Configuration for Squat Exercise

INTRODUCTION: Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft for travel to the Moon or to Mars is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and the musculoskeletal forces that occur during exercises performed on the prototype devices. METHODS The computational models currently under development utilize the OpenSim [1] software platform, consisting of open source code for musculoskeletal modeling, using biomechanical input data from test subjects for estimation of muscle and joint loads. The OpenSim Full Body Model [2] is used for all analyses. The model incorporates simplified wrap surfaces, a new knee model and updated lower body muscle parameters derived from cadaver measurements and magnetic resonance imaging of young adults. The upper body uses torque actuators at the lumbar and extremity joints. The test subjects who volunteer for this study are instrumented with reflective markers for motion capture data collection while performing squat exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device (ZIN Technologies, Middleburg Heights, OH). Ground reaction force data is collected with force plates under the feet, and device loading is recorded through load cells internal to the HULK. Test variables include the applied device load and the dual cable long bar or single cable T-bar interface between the test subject and the device. Data is also obtained using free weights with the identical loading for a comparison to the resistively loaded exercise device trials. The data drives the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the body loads. RESULTS Lower body kinematics, joint moments, joint forces and muscle forces are obtained from the OpenSim biomechanical analysis of the squat exercises under different loading conditions. Preliminary results from the model for the loading conditions will be presented as will hypotheses developed for follow on work.

Human Factors Engineering

Feasibility of Earthbound Motion in Lunar Gravity

BACKGROUND: Marginal stability of astronaut movement while performing lunar surface tasks has been well documented, and is clearly demonstrated in videos of falls, and near falls, during Apollo Lunar Extravehicular Activities. Referencing mission reports from Apollo 15 and 16 [1, 2], suspected causes for falls include: surface conditions, visibility, and gravitational effects (hypogravity). In this preliminary test, we employ the open-source biomechanical tool OpenSim [3, 4] to analyze the impact of lunar gravity (Lg) on two object-pickup motions performed by a single shirt-sleeved subject. Specifically, we attempt to answer the following questions based on an estimation of the Center of Mass Projection (CoMP) and ground reaction force Center of Pressure (COP) as it relates to the astronaut Base of Support (BOS) for 1g and Lg conditions: 1. Is the task motion, as performed in 1g, dynamically feasible in 1g and Lg? 2. Can we make the motion dynamically feasible in Lg by slowing it down? 3. Is the Lg COP equal to the 1g COP at a theoretically predicted reduction in motion speed? METHODS AND RESULTS: To answer the first question, the gravitational acceleration in the OpenSim model is modified from a nominal 9.81 m/s2 to 1.64 m/s2, and the 1g joint trajectory is input to an OpenSim based method [5] for estimating ground reaction forces and moments. From this method, the position of the CoMP and COP can be estimated and checked to see if they remain within a simulated BOS formed from the footprint of the OpenSim model to determine whether the motion is dynamically feasible. As expected, both of the motions were estimated to be feasible in a 1g environment, however, both motions had periods of infeasibility in Lg. It is well known that crew members make adjustments to motion trajectories in altered gravity fields to maintain balance. As a first step, we considered the simple adjustment of slowing the motion in Lg by a constant factor. This was accomplished by scaling the time stamps in the motion trajectory file by that factor. For the two motions considered, it was found that scale factors of 1.3 and 1.4 kept the COP just within the subject BOS. The CoMP is unchanged by the gravity field. Simple analysis of an inverted pendulum in the Lg environment, which generalizes to a general multibody system, leads to a theoretical prediction that a reduction in speed factor of √1g/Lg, or 2.445, will make the COP trajectory in Lg equivalent to that in 1g. When the above procedure was performed with a factor of 2.445, the estimated COP in Lg, was observed to be very close to that in 1g. In summary, we have developed a method for estimating the CoMP and COP in Lg, for subject motion collected in 1g. We believe this method can prove to be a valuable check and balance for simulated Lg training and testing by exposing potential simulator-induced artifacts that make the simulated task motion seem possible, when in fact, it would violate the above criteria. We also note that a reduction in task speed should tend the task motion towards stability, with a theoretical slowdown factor of √1g/Lg making the motion stability equal to that in 1g according to the CoMP and COP criteria.

R K Huffman

Modeling and Simulation Efforts to Support Improved Comfort in ARGOS

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch, and here we present preliminary modeling of that device using the open-source biomechanical tool OpenSim [1,2] with an in-house developed plugin. We analyze a series of motions performed by a single shirt-sleeved subject with goals of characterizing the device, validating the model, and predicting whether reduced gravity conditions (i.e., lunar gravity (Lg) or Martian gravity (Mg)) can be accurately simulated with the device, as well as providing comfort to the ARGOS user. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are either obtained from (1) inverse kinematics (IK) using motion capture markers on the various components of the device or (2) calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. Given the joint angles of the device, the resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) in order to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data and the forces from manual measurements of the spring both independently and integrated within the device. We found that calculated joint angles generally represent the angles measured and computed with IK, supporting a possible analysis workflow inputting human motion data and observing system behavior under varied design parameters. In two different device configurations in which the maximum applied force was 131 N, our current model accurately captured force with a difference of 2-3 N from measured loads. Though our initial test was performed with a shirt-sleeve subject, arm weights were added to emulate the weight of the suit sleeve and the subject was positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup. Arm range of motion tasks were performed outside of the HUT, inside the HUT, and inside the HUT while using the device. A variety of other upper body tasks were completed as well. In summary, we have developed a model to investigate and verify an upper limb offload device currently in development. We believe this model will be a valuable tool not only for device characterization but also to predict proper configurations to simulate Lg or Mg conditions, investigate range of motion concerns, predict limitations such as internal collisions and contacts, and inform future design improvements.

L B Nilsson

Modeling and Simulation of the Angel Upper Limb Offload Device: Branching Into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson

Modeling and Simulation of The Angel Upper Limb Offload Device: Branching into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson

Modeling and Simulation Credibility Assessments of Musculoskeletal Computational Models for Simulating Astronaut Injuries Due to a Poor Spacesuit Fit

The musculoskeletal (MS) system of astronauts is subject to physiological changes, potentially leading to injuries due to the exposure to different gravitational environments experienced during spaceflight. These injuries can occur while an astronaut is performing an Extravehicular Activity (EVA) in space, on lunar or planetary surfaces or while wearing a spacesuit during terrestrial training for an EVA. The OpenSim MS modeling software can assess EVA induced MS injury mechanisms such as muscle strains, ligament injuries and joint injuries. One area of concern, since there are only a few different spacesuit sizes with limited adjustability, is the possibility of a poorly fitting spacesuit. This can cause unnatural joint motions and torques resulting in various MS injuries. A credibility assessment of the OpenSim modeling and simulation procedures is performed per NASA-STD-7009A to provide information on the credibility of the model’s use in simulating EVA related injury mechanisms. The credibility assessment evaluated various OpenSim models against the following eight credibility factors: data pedigree, input pedigree, code verification, solution verification, conceptual validation, referent validation, results uncertainty and results robustness (sensitivity). The models evaluated for EVA injuries will require additional credibility factor analysis and upgrades to the model features, such as adding ligaments to a whole-body model, to reliably predict and analyze the EVA injuries expected to occur due to a poor spacesuit fit. The degree of elevation strategy required to increase the credibility assessment scores will depend on the model complexity and the injury mechanism.

Christopher A. Gallo

Modeling and Simulation Credibility Assessments of Musculoskeletal Computational Models for Simulating Astronaut Injuries Due to a Poor Spacesuit Fit

The musculoskeletal (MS) system of astronauts is subject to physiological changes, potentially leading to injuries due to the exposure to different gravitational environments experienced during spaceflight. These injuries can occur while an astronaut is performing an Extravehicular Activity (EVA) in space, on lunar or planetary surfaces or while wearing a spacesuit during terrestrial training for an EVA. The OpenSim MS modeling software can assess EVA induced MS injury mechanisms such as muscle strains, ligament injuries and joint injuries. One area of concern, since there are only a few different spacesuit sizes with limited adjustability, is the possibility of a poorly fitting spacesuit. This can cause unnatural joint motions and torques resulting in various MS injuries. A credibility assessment of the OpenSim modeling and simulation procedures is performed per NASA-STD-7009A to provide information on the credibility of the model’s use in simulating EVA related injury mechanisms. The credibility assessment evaluated various OpenSim models against the following eight credibility factors: data pedigree, input pedigree, code verification, solution verification, conceptual validation, referent validation, results uncertainty and results robustness (sensitivity). The models evaluated for EVA injuries will require additional credibility factor analysis and upgrades to the model features, such as adding ligaments to a whole-body model, to reliably predict and analyze the EVA injuries expected to occur due to a poor spacesuit fit. The degree of elevation strategy required to increase the credibility assessment scores will depend on the model complexity and the injury mechanism.

Christopher A Gallo

Squat Biomechanical Modeling Results from Exercising on the Hybrid Ultimate Lifting Kit

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and the musculoskeletal forces that occur during exercises performed on the prototype devices. The computational models currently under development utilize the OpenSim software, an open source code for musculoskeletal modeling, with biomechanical input data from test subjects for estimation of muscle and joint loads. The subjects are instrumented with reflective markers for motion capture data collection while exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device. Ground reaction force data is collected with force plates under the feet and device loading is recorded through load cells internal to the HULK. Test variables include applied device load, narrow or wide foot stance, slow or fast cadence and the harness or long bar interface between the test subject and the device. Data is also obtained using free weights for a comparison to the resistively loaded exercise device. This data is input into the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the body loads. The focus of this presentation is to summarize the results from the full squat exercises across the different test variables.

Bioengineering