SEARCH · Search NASA
Results for “Operation Chain Reaction”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Peroxy radical measurements with NCAR's chemical amplifier
The present NCAR instrument for HO2/RO2 measurements has been described previously. It is based on the reactions involving HO2, RO2, and HO radicals with CO and NO. Since (HO2) + (RO2) + (HO) is much greater than (HO) for most atmospheres, it is useful as a peroxy radical detector. Operation of the instrument depends on the creation of a chemical chain reaction which is initiated as HO2 and RO2 radicals in ambient air encounter added NO gas; this forms an NO2 molecule and an HO or RO radical: HO2(RO2) + NO yields HO(RO) + NO2. RO radicals react relatively efficiently with O2 to form an HO2 radical, and subsequently an HO-radical, by reaction with NO. CO gas added to the reaction chamber during part of the operating cycle, recycles the HO to HO2; HO + CO (+O2) yields HO2 + CO2. The reaction sequence may form several hundred NO2 molecules per HO2 (RO2) originally present, before chain termination occurs. The added CO is replaced by N2 addition periodically so that the chain reaction is suppressed, and a 'blank' signal resulting from NO2, O3 and possibly other NO2-forming species (non-chain processes) in ambient air is recorded. The difference between the signal with and without CO is proportional to the peroxy radical concentration. The NO2 produced is monitored using a sensitive luminol chemiluminescence detector system. In the NCAR instrument the length of the amplification chain is determined using a stable source of HO2 radicals (H2O2 thermal decomposition); the ratio of the signal seen with CO present to that with N2 present gives the sensitivity of the instrument to HO2 (molecules of NO2 formed/peroxy radical). The instrument is automated to carry out in hourly repeated cycles: (1) chain length determination; (2) NO2 calibration; and (3) linearity check on the response of signals. One minute averages of signals are normally recorded. The sensitivity of the instrument to detect peroxy radicals is in the pptv range. The present instrument has operated continuously (24 hr/day) in the field studies which extended over a period of several weeks. The major advantages of this instrument are as follows: (1) its relative simplicity; (2) low power requirements; and (3) its rapid response to all types of peroxy radicals--HO2, CH3O2 and the higher alkyl and acyl peroxy radicals; however not all RO2 species generate HO2 radicals with perfect efficiency and hence have somewhat lower response/molecule than HO2 radicals.
Photooxidation of Polyolefins to Produce Materials with In-Chain Ketones and Improved Materials Properties
Herein, we report a selective photooxidation of commodity postconsumer polyolefins to produce polymers with in-chain ketones. The reaction does not involve the use of catalyst, metals, or expensive oxidants, and selectively introduces ketone functional groups. Under mild and operationally simple conditions, yields up to 1.23 mol % of in-chain ketones were achieved. Installation of in-chain ketones resulted in materials with improved adhesion of the materials and miscibility of mixed plastics relative to the unfunctionalized plastics. The introduction of ketone groups into the polymer backbone allows these materials to react with diamines, forming dynamic covalent polyolefin networks. This strategy allows for the upcycling of mixed plastic waste into reprocessable materials with enhanced performance properties compared to polyolefin blends. Mechanistic studies support the involvement of photoexcited nitroaromatics in consecutive hydrogen and oxygen atom transfer reactions.
Guide for Oxygen Compatibility Assessments on Oxygen Components and Systems
A viewgraph presentation evaluating the compatibility of oxygen components and systems is shown. The topics include: 1) Application; 2) Gaining Wide Subscription; 3) Approach; 4) Establish Worst-Case Operating Conditions; 5) Assess Materials Flammability; 6) Evaluate Ignition Mechanisms; 7) Evaluate Kindling Chain; 8) Determine Reaction Affect; 9) Document Results; 10) Example of Documentation; and 11) Oxygen Compatibility Assessment Team.
Using Game Theory to Qualitatively Analyze Global Relations
As the world becomes smaller, the importance of global education increases. Technological advancements have made news instantaneous. The advent of the Internet has made contact with another part of the world just a click away. Such achievements have put pressure on educational institutions to prepare students for the global community in which they already live. !~ey must not only ~e taug~~ about the world and the interactions among countries, but also, how the decIsions are made which facillta~e. these interactions and what factors might contribute to the chain reactions which might erupt from such declsl?n~. It is critical that students learn the skills of decision-making and analysis in order to be able to operate Within a world where threats and crises abound. As tomorrow's leaders, today's students must be exposed to the global world and its mechanisms and learn the tools to navigate within it.
Digital Microfluidics Sample Analyzer
Three innovations address the needs of the medical world with regard to microfluidic manipulation and testing of physiological samples in ways that can benefit point-of-care needs for patients such as premature infants, for which drawing of blood for continuous tests can be life-threatening in their own right, and for expedited results. A chip with sample injection elements, reservoirs (and waste), droplet formation structures, fluidic pathways, mixing areas, and optical detection sites, was fabricated to test the various components of the microfluidic platform, both individually and in integrated fashion. The droplet control system permits a user to control droplet microactuator system functions, such as droplet operations and detector operations. Also, the programming system allows a user to develop software routines for controlling droplet microactuator system functions, such as droplet operations and detector operations. A chip is incorporated into the system with a controller, a detector, input and output devices, and software. A novel filler fluid formulation is used for the transport of droplets with high protein concentrations. Novel assemblies for detection of photons from an on-chip droplet are present, as well as novel systems for conducting various assays, such as immunoassays and PCR (polymerase chain reaction). The lab-on-a-chip (a.k.a., lab-on-a-printed-circuit board) processes physiological samples and comprises a system for automated, multi-analyte measurements using sub-microliter samples of human serum. The invention also relates to a diagnostic chip and system including the chip that performs many of the routine operations of a central labbased chemistry analyzer, integrating, for example, colorimetric assays (e.g., for proteins), chemiluminescence/fluorescence assays (e.g., for enzymes, electrolytes, and gases), and/or conductometric assays (e.g., for hematocrit on plasma and whole blood) on a single chip platform.
A Comprehensive Characterization of Microorganisms and Allergens in Spacecraft Environment
The determination of risk from infectious disease during long-duration missions is composed of several factors including the concentration and the characteristics of the infectious agent. Thus, a thorough knowledge of the microorganisms aboard spacecraft is essential in mitigating infectious disease risk to the crew. While stringent steps are taken to minimize the transfer of potential pathogens to spacecraft, several medically significant organisms have been isolated from both the Mir and International Space Station (ISS). Historically, the method for isolation and identification of microorganisms from spacecraft environmental samples depended upon their growth on culture media. Unfortunately, only a fraction of the organisms may grow on a culture medium, potentially omitting those microorganisms whose nutritional and physical requirements for growth are not met. Thus, several pathogens may not have been detected, such as Legionella pneumophila, the etiological agent of Legionnaire s disease. We hypothesize that environmental analysis using non-culture-based technologies will reveal microorganisms, allergens, and microbial toxins not previously reported in spacecraft, allowing for a more complete health assessment. The development of techniques for this flight experiment, operationally named SWAB, has already provided advances in NASA laboratory processes and beneficial information toward human health risk assessment. The translation of 16S ribosomal DNA sequencing for the identification of bacteria from the SWAB experiment to nominal operations has increased bacterial speciation of environmental isolates from previous flights three fold compared to previous conventional methodology. The incorporation of molecular-based DNA fingerprinting using repetitive sequence-based polymerase chain reaction (rep-PCR) into the capabilities of the laboratory has provided a methodology to track microorganisms between crewmembers and their environment. Both 16S ribosomal DNA identification and bacterial fingerprinting have improved NASA s capability to better understand spacecraft environments and determine the source of contamination events. Preflight sampling has been completed for air, surface, and water samples. In-flight sample collection has been completed for a total of 8 air and surface sample collection sessions. In-flight hardware has performed well and the surface sampling device received positive feedback from the crew for its ease of use. While processing and analysis continue for these samples, early results have begun to provide information on the spacecraft environment. Using a method called Denaturing Gradient Gel Electrophoresis (DGGE), several air and samples were evaluated to determine the types of organisms that were present. Using only molecular techniques, DGGE does not depend on any microbial growth on culture media, allowing a more comprehensive assessment of the spacecraft interior. Preliminary results have identified several microorganisms that would not have been isolated using current technology, though none of these organisms would be considered medically significant. Interestingly, the isolation of Gram negative organisms is greater using DGGE than conventional media based isolation. The cause of this finding is unclear, though it may be the result of the technique s ability to isolate both viable and non-viable bacteria. The next phase of the SWAB sample analysis is the use of quantitative polymerase chain reaction (QPCR) to look for specific medically significant organisms. While not as broad as DGGE, QPCR is much more sensitive and may reveal findings that were not seen during the initial evaluation. Together, this information will lead toward an accurate microbial risk assessment to help set flight requirements to protect the safety, health, and performance of the crew.
A Numerical Approach to Estimate the Ballistic Coefficient of Space Debris from TLE Orbital Data
Low Earth Orbit (LEO) is full of space debris, which consist of spent rocket stages, old satellites and fragments from explosions and collisions. As of 2009, more than 21,000 orbital debris larger than 10 cm are known to exist], and while it is hard to track anything smaller than that, the estimated population of particles between 1 and 10 cm in diameter is approximately 500,000, whereas small as 1 cm exceeds 100 million. These objects orbit Earth with huge kinetic energies speeds usually exceed 7 kms. The shape of their orbit varies from almost circular to highly elliptical and covers all LEO, a region in space between 160 and 2,000 km above sea level. Unfortunately, LEO is also the place where most of our active satellites are situated, as well as, International Space Station (ISS) and Hubble Space Telescope, whose orbits are around 400 and 550 km above sea level, respectively.This poses a real threat as debris can collide with satellites and deal substantial damage or even destroy them.Collisions between two or more debris create clouds of smaller debris, which are harder to track and increase overall object density and collision probability. At some point, the debris density couldthen reach a critical value, which would start a chain reaction and the number of space debris would grow exponentially. This phenomenon was first described by Kessler in 1978 and he concluded that it would lead to creation of debris belt, which would vastly complicate satellite operations in LEO. The debris density is already relatively high, as seen from several necessary debris avoidance maneuvers done by Shuttle, before it was discontinued, and ISS. But not all satellites have a propulsion system to avoid collision, hence different methods need to be applied. One of the proposed collision avoidance concepts is called LightForce and it suggests using photon pressure to induce small orbital corrections to deflect debris from colliding. This method is very efficient as seen from theoretical simulations, even few continuous mode 10 kW ground-based lasers, focused by 1.5 m telescopes with adaptive optics, were enough to prevent significant amount of the debris collisions. Simulations were done by propagating all space objects in LEO by 1 year into the future and checking whether the probability of collision was high. For those space objects different ground-based lasers were used to divert them, afterwards collision probabilities were reevaluated. However, the actual accuracy of the LightForce software, which has been developed at NASA AmesResearch Center, depends on the veracity of the input parameters, one of which is the objects ballistic coefficient. It is a measure of bodys ability to overcome air resistance, which has a significant impact on the debris in LEO, and thus it is responsible for the shape of the trajectory of the debris. Having the exact values of the ballistic coefficient would make significantly better collision predictions, unfortunately, we do not know what are the values for most of the objects.In this research, we were working with part of LightForce code, which estimates the ballistic coefficient from ephemerides. Previously used method gave highly inaccurate values, when compared to known objects, and it needed to be changed. The goal of this work was to try out a different method of estimating the ballistic coefficient and to check whether or not it gives noticeable improvements.
Laser Prevention of Earth Impact Disasters
Today we are seeing the geological data base constantly expanding as new evidence from past impacts with the Earth are discovered and investigated. It is now commonly believed that a hypervelocity impact occurring approximately 65 million years ago in the Yucatan Peninsula area was the disaster responsible for the extinction of almost 70% of the species of life on Earth including of course the dinosaurs. What is sobering is that we believe now that this was just one of several such disasters and that some of the others caused extinctions to even a greater extent. Preventing collisions with the Earth by hypervelocity asteroids, meteoroids, and comets is the most important problem facing human civilization. While there are many global problems facing our planet including overpopulation, pollution, disease, and deforestation; none of these offer the potential of rapid, total extinction. Rapid is the operative word here in that many of the global problems we face may indeed, if not sufficiently addressed, pose a similar long-term threat. However, with the impact threat, a single, almost unpredictable event could lead to a chain reaction of disasters that would end everything mankind has worked to achieve over the centuries. Our chances of being hit are greater than our chance of winning the lottery. We now believe that while there are only about 2000-earth orbit crossing rocks great than 1 kilometer in diameter, there may be as many as 100,000 rocks in the 100 m size range. The 1 kilometer rocks are difficult to detect and even harder to track. The 100 m class ones are almost impossible to find with today's technology. Can anything be done about this fundamental existence question facing us? The answer is a resounding yes. By using an intelligent combination of Earth and space based sensors coupled with high-energy laser stations in orbit, we can deflect rocks from striking the Earth. This is accomplished by irradiating the surface of the rock with sufficiently intense pulses so that ablation occurs. This ablation acts as a small rocket incrementally changing the shape of the rock's orbit around the Sun.
Successful Validation of Sample Processing and Quantitative Real-Time PCR Capabilities on the International Space Station
The WetLab-2 system was developed by NASA Ames Research Center to offer new capabilities to researchers. The system can lyse cells and extract RNA (Ribonucleic Acid) on-orbit from different sample types ranging from microbial cultures to animal tissues. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (Polymerase Chain Reaction) (qRT-PCR) analysis without the need for sample return. The qRT-PCR results can be downlinked to the ground a few hours after the completion of the run. The validation flight of the WetLab-2 system launched on SpaceX-8 on April 8, 2016. On orbit operations started on April 15th with system setup and was followed by three quantitative PCR runs using an E. coli genomic DNA template pre-loaded at three different concentrations. These runs were designed to discern if quantitative PCR functions correctly in microgravity and if the data is comparable to that from the ground control runs. The flight data showed no significant differences compared to the ground data though there was more variability in the values, this was likely due to the numerous small bubbles observed. The capability of the system to process samples and purify RNA was then validated using frozen samples prepared on the ground. The flight data for both E. coli and mouse liver clearly shows that RNA was successfully purified by our system. The E. coli qRT-PCR run showed successful singleplex, duplex and triplex capability. Data showed high variability in the resulting Cts (Cycle Thresholds [for the PCR]) likely due to bubble formation and insufficient mixing during the procedure run. The mouse liver qRT-PCR run had successful singleplex and duplex reactions and the variability was slightly better as the mixing operation was improved. The ability to purify and stabilize RNA and to conduct qRT-PCR on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.
Successful Validation of Sample Processing and Quantitative Real-Time PCR Capabilities on the International Space Station
The WetLab-2 system was developed by NASA Ames Research Center to offer new capabilities to researchers. The system can lyse cells and extract RNA (Ribonucleic Acid) on-orbit from different sample types ranging from microbial cultures to animal tissues. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (Polymerase Chain Reaction) (qRT-PCR) analysis without the need for sample return. The qRT-PCR results can be downlinked to the ground a few hours after the completion of the run. The validation flight of the WetLab-2 system launched on SpaceX-8 on April 8, 2016. On orbit operations started on April 15th with system setup and was followed by three quantitative PCR runs using an E. coli genomic DNA template pre-loaded at three different concentrations. These runs were designed to discern if quantitative PCR functions correctly in microgravity and if the data is comparable to that from the ground control runs. The flight data showed no significant differences compared to the ground data though there was more variability in the values, this was likely due to the numerous small bubbles observed. The capability of the system to process samples and purify RNA was then validated using frozen samples prepared on the ground. The flight data for both E. coli and mouse liver clearly shows that RNA was successfully purified by our system. The E. coli qRT-PCR run showed successful singleplex, duplex and triplex capability. Data showed high variability in the resulting Cts (Cycle Thresholds [for the PCR]) likely due to bubble formation and insufficient mixing during the procedure run. The mouse liver qRT-PCR run had successful singleplex and duplex reactions and the variability was slightly better as the mixing operation was improved. The ability to purify and stabilize RNA and to conduct qRT-PCR on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.
New procedure for evaluation of U(3) coupling and recoupling coefficients
A simple method to calculate Wigner coupling coefficients and Racah recoupling coefficients for U(3) in two group–subgroup chains is presented. While the canonical U(3) coupling and recoupling coefficients are applicable to any system that respects U(3) symmetry, the U(3) coupling coefficients are more specific to nuclear structure studies. This new procedure precludes the use of binomial coefficients and alternating sums which were used in the 1973 formulation of Draayer and Akiyama, and in so doing provides a faster and more accurate determination of any and all required results. The resolution of the outer multiplicity is based on the null space concept of the U(3) generators proposed by Alex et al., whereas the inner multiplicity in the angular momentum subgroup chain is obtained from the dimension of the null space of the SO(3) raising operator. It is anticipated that a C++ library will ultimately be available for determining generic coupling and recoupling coefficients associated with both the canonical and the physical group–subgroup chains of U(3).
Integrated Systems-to-Atoms (S2A) Framework for Designing Resilient and Efficient Hydrogen Infrastructure Solutions
The success of a future clean hydrogen infrastructure will depend on technology performance, operating conditions, and system configuration, which will be integrated to meet specific end-use requirements. We introduce a Systems-to-Atoms framework to cosimulate material, device, and system design for clean hydrogen storage and transport. Here we present a demonstration scenario in which hydrogen is distributed using a liquid organic hydrogen carrier to 700 bar refueling stations. Cross-scale analysis on hydrogen release at the refueling station reveals that while a high reaction pressure (up to 100 bar) may not enhance the catalyst performance, it can lead to system-level cost savings (up to 5% of total refueling station cost) due to savings in downstream gas compression. Further, a typically low-performing dehydrogenation catalyst material (e.g., copper) may be preferred over a high-performing catalyst (e.g., palladium) at different operating conditions when considering overall system affordability and supply chain resilience.
In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer
With a revived focus to create a permanent presence on the moon and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential.[1] In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen(LO2) for not only breathable air, but also for rocket propellant. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith.[2],[3] Although there are numerous minerals within regolith and various processes to extract O2,this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2(or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide(CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28.
In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer
With a revived focus to create a permanent presence on the moon and in preparation for future Mars exploration ,it is imperative that all resources are utilized to their fullest potential.[1] In-Situ Resource Utilization (ISRU)will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars.One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (LO2)for not only breathable air, but also for rocket propellant.On the moon and potentially Mars, one of the most O2rich resources is in the presence of regolith.[2],[3]Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this poster
In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer
With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.
Supramolecular Metal‐Organic Framework Electrocatalysts With Hydration‐Adaptive Gallery Expansion and Linker‐Mediated Distal Ni‐Co Cooperation Enable Framework‐Retentive Oxygen Evolution
Atomic‑level tailoring of electronic communication between spatially separated metal sites offers a route to accelerate multielectron electrocatalysis. We report Ni-TPTC, Co-TPTC, and heterobimetallic Ni-Co-TPTC supramolecular metal-organic frameworks (SMOFs) for the oxygen evolution reaction (OER) built from a terphenyl‑tetracarboxylate (TPTC) linker. Single-crystal X-ray diffraction of heterobimetallic Ni–Co–TPTC reveals trans-bis-aqua octahedral chains assembled into a π-stacked, hydrogen-bonded lattice and confirms retention of the parent architecture, while powder X-ray diffraction supports an isostructural Co analog. In 1.0 M KOH, Ni-Co-TPTC reaches 20 mA cm −2 at 350 mV and maintains operation at ∼60 mA cm −2 for 45 h with modest decay of the initial current. Time‑dependent ex situ diffraction shows dominant framework reflections with low‑angle shifts consistent with gallery dilation (d‑spacing ∼7.7 → ∼9.2 Å) during early operation, while Co K‑edge X‑ray absorption and microscopy reveal Co‑rich oxide/oxyhydroxide‑like domains at longer times that correlate with decay. X‑ray photoelectron spectroscopy, quantified by the Remote Binding‑Energy Differential, tracks composition‑dependent Ni-Co polarization, and DFT free‑energy analysis suggests that a model Ni-Co environment lowers the Co‑centered potential‑limiting step by ∼0.24 eV relative to the Co‑only framework. Furthermore, these results suggest that framework‑retentive expansion and distal Ni-Co coupling can drive OER activity before gradual deligation and oxide formation mark longer‑time degradation.
Rapid Nucleic Acid Isolation Method and Fluid Handling Devices Overview
Sample preparation is a common bottleneck in genetic analysis. Tools that reduce time and effort are of value in a laboratory setting. There is a need for a genetic analysis/detection system that is not only mobile, ruggedized, easy-to-use but also provides an enclosed fluid handling that diminishes the risks of Ribonucleic acid (RNA) contamination and degradation during processing. NASA has developed a novel assay methodology and suite of devices to isolate nucleic acids and prepare samples for real-time (quantitative) polymerase chain reaction (PCR) analysis that solves the problem of contamination and degradation because of the advanced microfluidics which provides better fluid handling. The assay employs an aqueous-based non-alcohol method that yields robust RNA quality. The suite of ready-to-use devices provide pre-loaded reagents in liquid and lyophilized formats to enable rapid, cost effective, and portable manual operation in the laboratory or remote field environments.