Search NASASearch

SEARCH · Search NASA

Results for “Operational Flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Insights Into Seismicity Associated With Flexibly Operating Enhanced Geothermal System From Real‐Time Distributed Acoustic Sensing

Enhanced Geothermal Systems (EGS) have the capacity to broaden the accessible resource pool for geothermal power generation. Traditionally viewed as a “baseload” resource, their flexible operation might also enable dispatchable load‐following generation and long‐term energy storage, aligning them with the evolving landscape of decarbonized electricity systems. However, increasing permeability and extracting energy during EGS operations can induce microseismic events; for many prior EGS efforts, some associated seismicity has been observed. While energetically beneficial, the flexibility of EGS operations prompts our inquiry into whether new types of operations will yield previously unseen seismicity patterns. We demonstrate the use of distributed acoustic sensing (DAS) with real‐time edge computing to monitor seismicity during a pilot test of a cyclically operated EGS facility at the Blue Mountain geothermal field. Our focus lies in uncovering seismicity insights from the real‐time microseismic catalog, particularly during load‐following dispatchability tests simulating flexible EGS operation. Here, we find that variations in pore pressure consistently correlate with seismicity, and that controlling pressure cycles during flexible operations appears to constrain microseismic activity during subsequent cycles. The spatio‐temporal evolution of microseismic clouds recorded during cyclic injection cycles fits diffusive models over our available observation period. Additionally, seismicity elevation lags behind pore pressure increases, likely due to pressure diffusion to the fracture system boundary. Through real‐time monitoring, we offer novel insights into seismicity associated with flexibly operating EGS. Our findings suggest that leveraging DAS and edge computing can inform EGS operations and help mitigate induced seismicity.

Chamarczuk, Michal [Rice Univ., Houston, TX (Unite

Flexible Operation of Natural Gas Power Plants in Texas: Startup and Shutdown Durations and Nitrogen Dioxide Emissions

This dataset provides insights into historical flexible operation of natural gas power plants in Texas, with a focus on startup and shutdown events. The dataset includes tables summarizing startup and shutdown durations as well as nitrogen oxide (NOx) emission factors during these events, and compares these emission factors with those observed during all other operating phases (referred to here as “steady-state operation”). The dataset is derived using the U.S. Environmental Protection Agency (EPA)’s Clean Air Markets Program Data (CAMPD). Historical hourly data from 2015–2024, including electricity generation, heat input, and NOx emission factors, are used for natural gas combined cycle units, combustion turbine units, and steam turbine units in Texas. This work was authored by the National Laboratory of the Rockies, operated by the Alliance for Energy Innovation, LLC, for the U.S Department of Energy (DOE) under contract no. DE-AC36-08GO28308. Funding was provided by the U.S. Department of Energy as part of its Grid Modernization Laboratory Consortium, a strategic partnership between DOE and the national laboratories to bring together leading experts, technologies, and resources to collaborate on the goal of modernizing the nation’s grid. The views expressed in the dataset do not necessarily represent the views of the DOE or the U.S. Government.

24 POWER TRANSMISSION AND DISTRIBUTION

Designing Operationally Flexible Diafiltration Membrane Systems for Critical Mineral Separations

This talk presents the design of operationally flexible diafiltration membrane systems for Li/Co recovery, and applies robust optimization methodologies using these flexible systems to generate optimal designs immune to membrane manufacturing variability and uncertain process inlet conditions. The results highlight the use of robust optimization to find design strategies and insights that may reduce technical risks arising from model uncertainties.

Yao, Jason

Environmental Validation of Materials and Design Concepts to Enable Operational Flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility will need to be evaluated for resilience to frequent start-ups, meeting major and rapid load changes, and providing frequency control duties. Our research objective was to evaluate and improve flexibility of existing power plants by improving and redesigning components and defining new operational strategies, with acceptable impacts on component life, efficiency and emissions.

20 FOSSIL-FUELED POWER PLANTS

Small-Signal Stability Constrained Optimal Power Flow of Inverter-Dominated Power Systems with Flexible Operation Mode Selection

Given the intermittence and low inertia nature of inverter-based resources (IBRs), modern power systems with high penetration of IBRs challenge the conventional optimal power flow (OPF) analysis and the system may experience unexpected failures if stability constraints are not incorporated. This study proposes a small-signal stability-constrained OPF (SSSC-OPF) with flexible operation mode selection between grid-forming (GFM) and grid-following (GFL) modes for IBRs to address these challenges. The approach aims to maintain system stability with a sufficient stability margin while minimizing operation costs. The effectiveness of the proposed method is validated through extensive case studies on the IEEE 14-bus system. The results demonstrate that the proposed method is able to support system-level power flow analysis, reduce generation costs, and ensure stability under various disturbances.

grid-following

Exploring Multidimensional Spatial-Temporal Hydropower Operational Flexibilities by Modeling and Optimizing Water-Constrained Cascading Hydroelectric Systems

Because of unique characteristics such as clean and cost-competitive electricity as well as fast-ramping and storage abilities, the power industry continues to evolve its operation strategies for cascading hydroelectric (CHE) systems for providing enhanced values to the grid, especially under the deeper renewable resource integration. However, existing operation practices of CHEs predate the integration of renewables, which could prohibit the effective utilization of their inherent flexibilities in delivering maximum financial benefits and providing valuable grid services to the power system and electricity market operations. Indeed, modeling and optimizing these resource-limited while flexible CHE assets with uncertainties and imperfect information across multiple spatial-temporal dimensions present significant challenges. To facilitate CHE facility operators in effectively coordinating water usage and hydropower plant operations across multiple timescales, this project aims to fill the existing gaps by developing a suite of accurate water inflow (WI) forecast models as well as enhanced CHE modeling and optimization approaches with proper consideration of their unique characteristics, which would help explore their multidimensional spatial-temporal operational flexibility potentials. The developed approaches could better align reservoir operation strategies with variability and uncertainty of future water availability. They can also promote more effective utilization of multidimensional spatial-temporal hydropower operational flexibility potentials by designing long-term evacuation plans of reservoirs and short-term operation of CHEs, along with their coordination with other types of renewables. The project leverages various resources to facilitate the research and development activities, including actual characteristics data of CHE systems and a library of current and future cases of Portland General Electric (PGE). These realistic data enable the project team to study how to maximize the value of CHEs under current and future portfolios and evaluate opportunities to improve operation practices.

13 HYDRO ENERGY

Flexible operation of nuclear hybrid energy systems for load following and water desalination

Nuclear hybrid energy systems (NHES) have the potential to provide dependable and emission-free electricity to the grid while also increasing the flexibility and reliability of the electrical grid. Molten salt reactor (MSR) technology can provide consistent, carbon-free electricity while also increasing efficiency, security, and sustainability and reducing nuclear waste. This study investigates the integration of Molten Salt Reactors (MSR) and conventional Pressurized Water Reactors (PWR) with desalination technologies: Direct Contact Membrane Distillation (DCMD), Multi-Stage Flash Distillation (MSFD), and Reverse Osmosis (RO). Dynamic first-principles models were developed and tested using real grid data from the New York Independent System Operator. The results demonstrate that nuclear power is capable of flexibly responding to changing grid demand while simultaneously producing clean water, particularly during periods of low electricity demand. The MSR-RO system was found to be the most efficient in electricity generation and water production, and all hybrid systems reduced CO2 emissions by 356,000 to 682,000 tons annually. Economic analysis reveals that nuclear desalination technologies are cost-competitive with conventional systems, especially when paired with RO. Finally, these findings confirm the technical feasibility and environmental benefits of nuclear hybrid systems for sustainable electricity and water production.

24 POWER TRANSMISSION AND DISTRIBUTION

Flexible Operation of Microgrids Through Operator-Configurable Microgrid Controllers

Microgrids are becoming critical assets in power distribution systems. This is partly due to the resiliency and reliability challenges faced by power distribution systems in the last decade and partly due to the increased integration of distributed energy resource assets, such as solar photovoltaic. This increased need for microgrids has created a multitude of needs for microgrid controllers. Most microgrid controllers in the past decade have been uniquely programmed or custom programmed to meet the needs of a specific microgrid. Currently, IEEE standards aim to integrate the needs and capabilities of microgrid controllers under a unified umbrella. But the standards do not recommend necessary or appropriate software development practices for microgrid controllers. In addition, the programmable nature and maintenance of controllers are also key characteristics that fall outside the coverage of the standards. In this paper, we present the best software practices that utility engineers and microgrid operators should consider in the microgrid software platform. This paper can be used as an information document for developing documentation of controller requirements and assessing microgrid controller requirements.

Banshee microgrid

Passive Wireless Sensors for Realtime Temperature and Corrosion Monitoring of Coal Boiler Components Under Flexible Operation (Final Technical Report)

Researchers at West Virginia University (WVU) propose to demonstrate inexpensive wireless, high-temperature sensors for real-time monitoring of the temperature and corrosion of metal components, which are commonly used in coal-fired boilers. This study presents the development of cost-effective wireless high-temperature sensors for real-time temperature and corrosion monitoring in coal-fired boilers' metal components. The focus is on fabricating and evaluating chipless radio-frequency identification (RFID) sensors capable of operating between 25-1300 ºC. Efforts were directed towards designing passive RFID sensor and interrogator antenna with a broad frequency range, optimizing a microstrip patch antenna sensor integrated into a "peel-and-stick" format for efficient application to various metal specimens without altering their geometry. Additionally, this research aimed to assess the sensor responses under accelerated high-temperature conditions, correlating corrosion and cracking mechanisms with sensor data. An investigation of through-wall data acquisition techniques was also planned, facilitating unobtrusive monitoring of sensor responses housed within metal enclosures. Ultimately, this work sought to establish a robust passive wireless sensor system for the continuous health monitoring of metal components in operational settings, thereby contributing to enhanced safety and efficiency in coal-fired power plants.

20 FOSSIL-FUELED POWER PLANTS

Co-optimization of nuclear reactor flexible power operation and maintenance scheduling

As flexible power operation of nuclear power plants becomes more attractive due to the reduction in fossil-fueled dispatchable generation on energy grids, finding optimal power production strategies that balance revenue generation with operational concerns becomes more complex. This article presents a general framework to aid operators in designing economically optimal long term dispatch strategies for nuclear power plants. The principal novelty is the linking of estimated system remaining useable life (RUL) to strategic operational decisions. It is shown that, depending on the relationship between the fixed costs from maintenance and the associated lost revenue from an outage, it can be economically optimal in the long term to delay a maintenance outage and not perform this alongside refueling. For a given relationship between power ramping and degradation, optimal strategies were found that discouraged load following in some situations while minimizing unnecessary maintenance. It is shown that heavy load following can cause maintenance and refueling outages to diverge due to their inverse relationships with respect to load following, potentially leading to a significant loss in capacity factor. As a result, this general framework can be applied to specific reactor dispatch allowing operators to adapt operational strategies as future grid conditions change.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

The value of hydropower flexibility for electricity system decarbonization

Hydropower is an abundant, dispatchable, clean energy resource that will play an important role in supporting the clean energy transition. In particular, dispatchable hydropower can provide the operational flexibility that will be required in future systems with high variable renewable energy penetrations. However, the theoretical operational flexibility of hydropower can be restricted in practice by various non-power constraints. In this paper, we quantify how increasing the operational flexibility of dispatchable hydropower resources with reservoirs impacts least-cost generation portfolios and supports power system decarbonization. Specifically, we conduct a capacity expansion analysis of a two-zone system: a hydro-dominated region and a neighboring region with aggressive decarbonization targets that are represented by the United States Pacific Northwest and California respectively. We then introduce a quantifiable index for characterizing the operational flexibility of reservoir hydropower and assess how changes in this metric impact the system-optimal generation portfolio. We find that increasing hydropower flexibility leads to more investment in wind generation, less investment in natural gas generation, lower system costs, and lower system emissions. We further demonstrate a substitution effect between the grid services provided by flexible hydropower operation, increased transmission capacity on a congested line, and energy storage resources. Finally, we show that increasing the operational flexibility of hydropower increases the effective load carrying capability of both hydropower and wind resources. This research supports a more nuanced understanding of how hydropower can support electricity system decarbonization and may motivate reassessing the cost-benefit tradeoffs of non-power constraints that restrict operational flexibility.

Capacity expansion modeling

Load-Shifting Strategies for Cost-Effective Emission Reductions at Wastewater Facilities

Significant hourly variation in the carbon intensity of electricity supplied to wastewater facilities introduces an opportunity to lower emissions by shifting the timing of their energy demand. This shift could be accomplished by storing wastewater, biogas from sludge digestion, or electricity from on-site biogas generation. However, the life cycle emissions and cost implications of these options are not clear. Here, we present a multiobjective optimization framework for comparing cost- and emission-minimizing load-shifting strategies at a California case study facility with a relatively low carbon intensity grid and high spread in peak and off-peak electricity prices. We evaluate cost and emission trade-offs from the optimal flexible operation of both existing infrastructure and optimally sized energy flexibility upgrades. We estimate energy-related emission reductions of up to 9.0% with flexible operation of existing infrastructure and up to 16.8% with optimally sized storage upgrades. Only a fraction of these potential savings are realized under actual industrial energy tariffs and the EPA’s recommended social cost of carbon. Energy flexibility may hold promise as a short-term emission-saving solution for the wastewater sector, but the extent of savings is heavily dependent on the cost of carbon, electricity tariffs, and emission intensity of the regional electricity grid.

climate

A comparison of ceramic and carbon-based reductants for vitrification of low-activity waste

Sucrose is the current baseline additive at the Hanford Waste Treatment and Immobilization Plant in Washington, USA to control foaming during waste feed to glass transitions and the redox state of the glass melt. Alternative reductants are being investigated to alleviate strain on effluent treatment from toxic acetonitrile production from incomplete combustion of sucrose. This study evaluates ceramic additive options including B4C, B6Si, SiC and VB2 in simulated low-activity waste feed, as well as coke dust, probing the feed volume expansion during melting as well as the gas evolution. All alternative reductant options examined significantly reduced acetonitrile production, however there was variability in their effectiveness as foam-reducing agents. VB2 and coke at the appropriate ratios were similarly effective as sucrose in controlling both foam volume and glass redox state, but with considerably less acetonitrile production. B4C, B6Si and SiC showed more promising foam control and very little acetonitrile production, however all of the final glasses were over reduced, i.e., Fe2+/FeT = 0.5. These alternative reductant studies provide operational flexibility to the operation of the vitrification plant, as well as options for alternative raw materials in industrial glass melting.

Rigby, Jessica C. (ORCID:0000000235719977)

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION

White Paper: Research & Development for the Time at Temperature Approach

Recent advancements in nuclear power research are greatly improving reactor safety and performance through the development of Accident Tolerant Fuel (ATF) and Low-Enriched Uranium Plus (LEU+). These innovations can address Departure from Nucleate Boiling (DNB) margins, which are vital for reactor safety. DNB happens when the coolant switches to film boiling, significantly decreasing heat transfer and posing a risk of fuel cladding failure. The U.S. Nuclear Regulatory Commission (NRC) employs conservative DNB criteria, which can potentially restrict the operational flexibility and efficiency of reactors. The Time at Temperature (TaT) approach could provide a more detailed and adaptable operational guideline by establishing acceptable time-temperature limits, accounting for the duration a material can withstand elevated temperatures without losing its integrity. This method allows reactors to operate more efficiently and safely, offering additional operational margins, faster power adjustments, and improved fuel cycle economics. TaT criteria allow for higher power levels and more flexible responses to operational transients, particularly applicable for anticipated operational occurrences (AOOs) that result in short durations of post-DNB conditions. It enhances plant operational flexibility, allows faster startup times, and enables quicker power level adjustments, optimizing fuel loading patterns and improving fuel cycle economics. Implementing TaT limits reduces core design constraints, lowers fuel usage, and reduces costs, essential for the long-term sustainability of Light Water Reactors (LWRs). TaT maximizes the use of advanced fuel technologies like ATF and LEU+, further enhancing their economic and environmental benefits. To apply the TaT approach in existing LWRs, collaborative research activities among various DOE-sponsored programs are essential. These efforts should incorporate fuel experiments, physics-based high-fidelity modeling, ML-based surrogate modeling, and optimization techniques. This whitepaper proposes four research and development areas: 1) Investigation of the feasibility of new operations of LWR with updated safety limits; 2) Assessment of reactor operation limits through uncertainty reduction; 3) Evaluation of power uprate in virtual environment; and 4) Lattice and reactor core design for power uprate. Each area includes why this research is in need and a suggested scope of work. These comprehensive research areas ensure practical and beneficial advancements for existing reactors, translating innovations in nuclear fuel and cladding technology into improved reactor performance and safety.

42 - ENGINEERING

Optimal operation of solid-oxide electrolysis cells considering long-term chemical degradation

Optimizing the performance of solid oxide electrolysis cells (SOECs) for long-term hydrogen (H 2 ) production at high temperatures is crucial, as prolonged operation leads to efficiency losses and shorter cell lifespans due to chemical degradation. Here, in this work, we adopt a quasi-steady state approach for dynamic optimization over extended operational periods to address the disparity in timescales between cell operation and degradation. Integrating a 2-D non-isothermal SOEC model with balance-of-plant (BOP) equipment, we explore three optimization objectives: minimizing terminal degradation, maximizing integral efficiency, and minimizing the levelized cost of H 2 (LCOH). Our dynamic optimization algorithm reduces LCOH by 9.5% and 16% compared to strategies focusing solely on terminal degradation and integral efficiency, respectively. For electricity prices of 0.03 $\$$/mWh and 0.3 $\$$ mWh optimal replacement schedules range from 5 to 2 years, depending on the operational mode. Furthermore, a flexible operational mode yields additional improvements in LCOH over traditional galvanostatic and potentiostatic modes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Intelligent industrial demand response to increase grid flexibility and reliability: A review

The rapid transition toward renewable energy has introduced challenges in grid stability due to the intermittency of non-dispatchable sources like solar and wind. Industrial Demand Response (IDR) offers a promising, cost-effective solution that adjusts energy consumption patterns to align with supply, increases renewable utilization, and reduces costs. This review provides an updated analysis of IDR, sorting technologies into five categories: energy storage, scheduled energy usage, operational flexibility, on-site generation, and intelligent operations. Energy storage solutions, while requiring little flexibility, often have the longest payback periods. While slightly better, on-site generation also has longer payback periods, ranging from 5 to 20 years or more. Scheduled energy usage, operational flexibility, and intelligent operations allow significant peak reduction at lower capital costs but require greater flexibility. While 15–20 % peak reduction is within the range of all five categories, scheduled energy use and on-site energy generation are shown to have reductions of up to 70–80 % in select scenarios. Combining multiple IDR strategies from these five categories maximizes both financial and operational benefits. Synergistic approaches are shown to enhance grid stability while reducing costs. As the grid evolves, IDR will enable a more flexible, renewable-powered future that will benefit industrial facilities and the broader energy system.

Demand flexibility

Advancing Conduction-Cooled 650 MHz SRF Technology for Industrial Accelerators at Fermilab's IARC

The National Nuclear Security Administration (NNSA) funds the Illinois Accelerator Research Center (IARC) at Fermilab in developing a high-power, conduction-cooled Superconducting Radio Frequency (SRF) accelerator tailored for industrial applications requiring robust and efficient operation. A 650 MHz, 1.6 MeV, 20 kW SRF accelerator is currently under development, employing a conduction cooling approach to simplify cryogenic requirements and enhance accessibility for industrial use. The accelerator’s control system is implemented on the Blinky Lite platform, selected for its open-source architecture, secure remote access capabilities, and operational flexibility—attributes advantageous for industrial deployment and sustained operation. A dedicated beamline is designed to measure essential beam parameters and test the integrated performance of the accelerator and control systems, thereby validating their operational readiness for intended applications

Ji, Y. [Fermilab] (ORCID:0000000233981752)