Exploration of synergistic behavior of operational amplifiers in combined ion and electron environment.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
As a part of the Proton Improvement Plan – II (PIP-II) at Fermilab, instrumentation systems are being modernized to take advantage of the higher speeds and ease of use offered by standardized embedded systems like MicroTCA. A rear-transition module (RTM) is being designed to interface with said embedded systems. In each of the four identical channels on the RTM, the differential signal from an alternating-current current transformer (ACCT) transimpedance amplifier will again be amplified by a differential operation-amplifier, then filtered by a low-pass topology. The conditioned signal is then digitized at a maximum of 10MS/s by an analog to digital converter (ADC) integrated circuit. After digitization, the ADC passes the data to an off the shelf AdvancedMC (AMC) Xilinx FPGA module using low voltage differential signals. This paper will describe the simulation of analog circuitry for signal conditioning, simulation of digital signal integrity based on physical design as well as verification of design characteristics critical to signal integrity. This work aims to create a methodology that can be applied to future RTMs requiring application of high-speed digital design principles.
As a part of the Proton Improvement Plan II (PIP-II) at Fermilab, instrumentation systems are being modernized to take advantage of the higher speeds and ease of use offered by standardized embedded systems like MicroTCA. A rear-transition module (RTM) is being designed to interface with said embedded systems. In each of the four identical channels on the RTM, the differential signal from an alternating-current current transformer (ACCT) transimpedance amplifier will again be amplified by a differential operation-amplifier, then filtered by a low-pass topology. The conditioned signal is then digitized at a maximum of 10MS/s by an analog to digital converter (ADC) integrated circuit. After digitization, the ADC passes the data to an off the shelf AdvancedMC (AMC) Xilinx FPGA module using low voltage differential signals. This paper will describe the simulation of analog circuitry for signal conditioning, simulation of digital signal integrity based on physical design as well as verification of design characteristics critical to signal integrity. This work aims to create a methodology that can be applied to future RTMs requiring application of high-speed digital design principles.
We report the demonstration of a diode-pumped Tm:YLF laser operating at 1.88 µm that produces pulse energies up to 3.88 J in 20 ns. The compact system consists of a Q-switched cavity-dumped oscillator generating 18 mJ pulses, which are then amplified in a 4-pass power amplifier. Energies up to 38.1 J were obtained with long-pulse amplifier operation. These results illustrate the high energy storage and extraction capabilities of diode-pumped Tm:YLF, opening the path to high peak and average power mid-infrared solid-state lasers
A multilevel inverter is an electronic device capable of changing direct current energy to alternant current energy with a voltage and frequency established by the user. They are ideal for connecting renewable energy sources to the AC grid, energy plants, and smart grids. The voltage must be balanced and synchronized with the electrical network for adequate performance. This paper shows the voltage synchronization between an inverter output voltage and the AC grid using a phase-locked loop based on an adaptive observer. The proposed algorithm can perform under grid uncertainties such as noise and generates a reference signal for the modulation used in the inverter. The algorithm is robust and computationally efficient and can be implemented through basic elements such as operational amplifiers, resistors, and capacitors, reducing its difficulty in executing it in a system.
The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30 deg/kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.
Superconducting microwave amplifiers are essential for sensitive signal readout in superconducting quantum processors. Typically based on Josephson junctions, these amplifiers require operation at milli-Kelvin temperatures to achieve quantum-limited performance. Here, we demonstrate a quantum microwave amplifier that employs radiative cooling to operate at elevated temperatures and maintain near quantum-limited added noise. This kinetic-inductance-based parametric amplifier, patterned from a single layer of relatively high-Tc NbN thin film, maintains a high gain and meanwhile enables low added noise of 1.3 quanta when operated at 1.5 K. Remarkably, this represents only a 0.2 quanta increase compared to the performance at a base temperature of 0.1 K. Based on our findings, we also discuss the practicality of such an operating scheme for various quantum applications. By uplifting the parametric amplifiers from the mixing chamber without compromising readout efficiency, this work represents an important step toward more scalable microwave quantum technologies.
We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.
The stabilization of tearing modes with rf driven current benefits from the cooperative feedback loop between rf power deposition and electron temperature within the island. This effect, termed rf current condensation, can greatly enhance and localize the current driven within magnetic islands. It has previously been shown that the condensation effect opens the possibility of passive stabilization with broad rf profiles, as would be typical of LHCD for steady state operation. Here, we show that this self-healing effect can be dramatically amplified by operation in a hot ion mode, due to the additional electron heat source provided by the hotter ions.
We present the design and test results of a Drivers and Limiting AmplifierS ASIC operating at 10 Gbps (DLAS10) and three Miniature Optical Transmitter/Receiver/Transceiver modules (MTx+, MRx+, and MTRx+) based on DLAS10. DLAS10 can drive two Transmitter Optical Sub-Assemblies (TOSAs) of Vertical Cavity Surface Emitting Lasers (VCSELs), receive the signals from two Receiver Optical Sub-Assemblies (ROSAs) that have no embedded limiting amplifiers, or drive a VCSEL TOSA and receive the signal from a ROSA, respectively. Each channel of DLAS10 consists of an input Continuous Time Linear Equalizer (CTLE), a four-stage limiting amplifier (LA), and an output driver. The LA amplifies the signals of variable levels to a stable swing. The output driver drives VCSELs or impedance-controlled traces. DLAS10 is fabricated in a 65 nm CMOS technology. The die is 1 mm x 1 mm. DLAS10 is packaged in a 4 mm x 4 mm 24-pin quad-flat no-leads (QFN) package. DLAS10 has been tested in MTx+, MRx+, and MTRx+ modules. Both measured optical and electrical eye diagrams pass the 10 Gbps eye mask test. Furthermore, the input electrical sensitivity is 40 mVp-p, while the input optical sensitivity is -12 dBm. The total jitter of MRx+ is 29 ps (P-P) with a random jitter of 1.6 ps (RMS) and a deterministic jitter of 9.9 ps. Each MTx+/MTRx+ module consumes 82 mW/ch and 174 mW/ch, respectively.
We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m 3 axion search, which uses dc SQUIDs in this frequency range.
Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.
In optical parametric chirped-pulse amplification (OPCPA), pump temporal intensity modulation is transferred to the chirped-signal spectrum via instantaneous parametric gain and results in contrast degradation of the recompressed signal. We investigate, for the first time to our knowledge, the pump-to-signal noise transfer in a two-stage ultra-broadband OPCPA pumped by a single laser and show the dependence of pump-induced signal noise, characterized both before and after pulse compression, on the difference in pump-seed delay in the two stages. We demonstrate an up-to-15-dB reduction of the pump-induced contrast degradation via pump-seed delay optimization. Experiments and simulations show that, even when parametric amplifiers are operated in saturation, the pump-seed delay can be used to minimize the pump-induced contrast degradation that is attributed largely to the noises from the unsaturated edges of the pulse and that of the beam.
Klystron amplifiers have been operated at the Spallation Neutron Source (SNS) in support of the user program since 2006. SNS tubes have amassed over 100,000 hours of high-voltage and filament-on time providing a significant source of operational statistics for high power, high-duty klystrons. Additionally, the SNS Radiofrequency (RF) Systems Group has developed operational methods to mitigate specific reliability challenges, such as cathode arcing and output power instability. Despite much progress, many of these challenges persist, prompting the SNS to update the procedures used for klystron processing as well as develop a higher throughput test stand.
The PIP-II Injector Test (PIP2IT) has successfully accelerated ionized hydrogen up to 17MeV through a superconducting, single spoke resonator (SSR1) cryomodule at Fermi National Accelerator Laboratory (FNAL). Each of the SSR1 cavities is tuned to 325MHz and requires up to 6 kW of RF power to accelerate 2mA of ionized hydrogen at the design gradients. RF power amplifiers, specialized for SRF cavity beam operations, were designed by Bhabha Atomic Research Center (BARC) and constructed in a collaboration between the BARC in Mumbai, India and the Electronics Corporation of India Limited (ECIL) in Hyderabad, India. The RF amplifiers meet the specifications and requirements mutually approved between BARC and FNAL. They operate at 325 MHz with a linear power output of 7 kW in both CW and pulse mode. The amplifiers are compatible with the FNAL accelerator personnel safety system and the cavity protection interlocks. Access to controls and internal diagnostic instrumentation are compatible with EPICS control standards. This paper gives details about RF power amplifier development within the Department of Atomic Energy (DAE), India and the operational details with PIP2IT at FNAL.