SEARCH · Search NASA
Results for “Optical measurement”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A Non-Intrusive Optical (NIO) Method to Measure Optical Errors of in-situ Heliostats in Utility-Scale Power Tower Plants: Detecting Uncertainties in Heliostat Geometry
Heliostat optical errors can account for significant losses in efficiency of power tower concentrating solar power (CSP) plants. Accurately measuring heliostat optical errors can help to improve plant performance. A Non-Intrusive Optical (NIO) method has been developed to efficiently measure heliostat optical errors from UAS collected images of the mirror surface reflection [1]–[3]. In some cases, plant data of heliostat geometry can be incomplete or contain inaccuracies, in which case field collected data can be used to detect and correct uncertainties, which is valuable information for plant operators.
Demonstration and Automation of Reflected Target Optical Measurement for Heliostats
Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. Since 2022, NREL has been developing a measurement method called the Reflected Target Non-intrusive Assessment (ReTNA) system. This system differs from most established methods in that we perform deflectometry with a pattern of coded targets, identified in space with photogrammetry. Reflected target systems have several advantages over traditional fringe deflectometry systems. Firstly, they can be operated in bright or ambient lighting, a challenge for fringe systems that use a projector and screen. Reflected target systems also can use a much lighter and less expensive target than projector-based systems. Lastly, 2D slope measurement can be solved from a single image, which leads to several advantages for accommodating faster measurements and smaller sized targets. These advantages make ReTNA particularly well-suited for applications where there are space or lighting constraints, like performing heliostat quality assurance on an assembly line. It's also useful when a lightweight, flexible system is needed, like for heliostat developers to quickly measure a new heliostat design at different orientations, to observe gravitational effects on the mirror surface shape. In the last year, significant improvements were made to this tool to make it more useful for these applications. These improvements were focused around validation of the ReTNA measurement system, and automation of the setup and measurement process. First, we present an improved ReTNA layout, for use on the heliostat assembly line. Next, we detail the various changes to the ReTNA software and computer vision methods to automate data collection in this new setup, and lessons learned from this process. The goal with this new setup is to perform a full heliostat surface characterization without removing the mirror from the assembly line. Lastly, we share results from several ReTNA validation studies undertaken over the last year. These include repeated ReTNA measurement on demonstration mirror facets, comparisons with other optical measurement tools, and some studies aimed at quantifying the uncertainty of ReTNA measurement under various constraints (mirror-target spacing, camera resolution, etc.). These results are compared with 2024 HelioCon performance targets, and our planned next steps for the ReTNA measurement system are presented.
Systems and methods for optical measurement of cross-wind
Various technologies pertaining to optical measurement of cross-wind are described herein. A beam of light is emitted along a trajectory through a shooting space from a location of a shooter to a target using a laser. The beam is reflected by the target, and the beam is received at two optical detectors. Due to changes in the index of refraction of air along the path of the beam, an envelope signal atmospherically encoded on the beam is received at each of the two apertures at different times. A signal analyzer receives a signal from each of the detectors and outputs data indicative of an average speed of the cross-wind along the trajectory in the shooting space based upon a time delay between the signals.
Low-Frequency Oscillations in Optical Measurements of Metal-Nanoparticle Vibrations
Time-resolved optical measurements of vibrating metal nanoparticles have been used extensively to probe the ultrafast mechanical properties of the nanoparticles and of the surrounding liquid, but nearly all investigations so far have been limited to the linear regime. Herein, we report the observation of a low-frequency oscillating signal in transient-absorption measurements of nanoparticles with octahedral gold cores and cubic silver shells; the signal appears at the difference of two mechanical vibrational frequencies in the particles, suggesting a nonlinear mixing process. We tentatively attribute this proposed mixing to a nonlinear coupling between a vibrational mode of the nanoparticle and its optical-frequency plasmon resonance. The optimization of this nonlinear transduction may enable high-efficiency opto-mechanical frequency mixing in the GHz-THz frequency regime.
Nonlinear Optics Measurements in IOTA
Nonlinear integrable optics is a recently proposed accelerator lattice design approach which allows to generate an amplitude dependent tune shift which is needed in high brightness accelerators to mitigate fast coherent instabilities. Whereas usually octupoles are used to achieve this task, this concept allows doing so without exciting any resonances, in turn preventing any particle loss. The concept is based around a special magnet design, together with specific constraints on the optics of the accelerator. To study such a system, the Integrable Optics Test Accelerator (IOTA) was recently constructed and commissioned at Fermilab. For the assessment of the performance of this concept, good knowledge of the optics and the (non-)linear dynamics without the special magnet is of key importance. As such, measurements were conducted in the IOTA ring, using the captured turn-by-turn data by the beam position monitors after excitation to infer quantities such as amplitude detuning and resonance driving terms. In this note, first results of these measurements are presented.
Method and system to separate optically measured coupled parameters
A system includes a first optical sensor sensitive to both a parameter of interest, Parameter1, and at least one confounding parameter, Parameter2 and a second optical sensor sensitive only to the confounding parameter. Measurement circuitry measures M1 in response to light scattered by the first optical sensor, where M1=value of Parameter1+K*value of Parameter2. The measurement circuitry also measures M2 in response to light scattered by the second optical sensor, where M2=value of Parameter2. Compensation circuitry determines a compensation factor, K, for the confounding parameter based on measurements of M1 and M2 taken over multiple load/unload cycles or over one or more thermal cycles. The compensation factor is used to determine the parameter of interest.
Electro-optical measurement of intense electric field on a high energy pulsed power accelerator
We describe a direct electro-optical approach to measuring a strong 118 MV/m narrow pulse width (~ 33 ns) electric field in the magnetically insulated transmission line (MITL) of a pulsed power accelerator. To date, this is the highest direct external electric field measured electro-optically in a pulsed power accelerator, and it is between two to three orders of magnitude higher than values reported in comparable high energy scientific experiments. The MITL electric field is one of the most important operating parameters in an accelerator and is critical to understanding the properties of the radiation output. However, accurately measuring these high fields using conventional pulsed power diagnostics is difficult due to the strength of interfering particles and fields. Our approach uses a free-space laser beam with a dielectric crystal sensor that is highly immune to electromagnetic interference and does not require an external calibration. Here we focus on device theory, operating parameters, laboratory and pulsed power accelerator experiments as well as challenges that were overcome in the measurement environment.
The impact of optical measurement techniques on measured aerosol particle size distributions
Ambient aerosol particle size distributions measured by the Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) at various sites around the world exhibit modes at optical diameters near 600 nm and 850 nm. These modes are not present in concurrent measurements with the Grimm 11-D Optical Particle Counter (OPC). Here, in this study, we argue that these modes result from the optical measurement technique itself, and we explain why they appear in measurements by the UHSAS but not in those by the Grimm OPC. We construct computer models of the UHSAS and Grimm (“digital UHSAS” and “digital Grimm”) and use these to investigate the size distribution that would result from measurements of artificial aerosol particle size distributions that do not contain modes. The appearance of modes for the structureless incoming size distributions sampled by the digital UHSAS is explained by the nonlinear behavior of partial scattering cross sections of uniform spherical particles as a function of their diameter. The absence of modes in the digital Grimm is explained by the coarser size resolution of that instrument. Detailed analysis of the relationship between optical and geometric diameters for uniform spherical particles reveals two important results. First, these diameters generally have different numerical values for the same particle, and second, the relationship is nonlinear; thus, widths of size bins in terms of optical diameter differ from those in geometric diameter. These results explain the modes observed in the ambient size distributions and highlight concerns with attempts to create a merged size distribution by combining measurements from different instruments.
Electro-Optical Measurement Techniques
Utilize the unique characteristics of photons across different regions of the electromagnetic spectrum to probe the optical and electronic properties of chemical systems, materials and devices for energy conversion technologies.
Beam Optics Measurements at the Fermilab Linac
The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator complex. The Linac will be replaced by a SRF Linac that doubles the output energy as part of the Proton Improvement Plan-II (PIP-II) project. For successful PIP-II commissioning and operation, a comprehensive suite of longitudinal and transverse measurements are planned to fully characterize the beam dynamics. In the 400 MeV Linac, we used prototype programs to demonstrate the viability of these workflows. Here we present the results of these measurements of longitudinal and transverse optics.
Overview of On-Line Optical Measurements at High Pressure for Flue Gases, Particulates and Acid-dew Point of Pressurized Oxy-Combustion
Optical flow cells are critical measurement interfaces, yet sampling under harsh conditions — high pressure, high temperature, particles, moisture, or corrosive gases — makes it difficult to maintain optical quality without perturbing the measurement. To address this challenge, a new flow cell was developed using a laminar coaxial flow field that separates the purge and sample flows. A dedicated test system was built to evaluate particle size distribution (PSD) measurements using a Malvern Panalytical Insitec analyzer. Results demonstrated that the sample flow alone defines the measurement zone, while the purge flow effectively shields the optical windows from deposition, eliminating sampling bias. The flow cell enables reliable PSD measurement under high pressure and temperature in moist, corrosive environments. As a key demonstration, the instrument was successfully deployed for on-line PSD measurement of flue gas from a 100 kWth pressurized oxy-coal combustor at 15 bara.
Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid
We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.
Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator
We describe a direct magneto-optical approach to measuring the magnetic field driven by a narrow pulse width (<10 ns), 20 kA electrical current flow in the transmission line of a high energy pulsed power accelerator. The magnetic field and electrical current are among the most important operating parameters in a pulsed power accelerator and are critical to understanding the properties of the radiation output. However, accurately measuring these fields and electrical currents using conventional pulsed power diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element sensing crystal sensor that is highly resistant to electromagnetic interference and does not require external calibration. Here, we focus on device theory, operating parameters, results from an experiment on a high energy pulsed power accelerator, and comparison to a conventional electrical current shunt sensor.
Distributed Fiber Optics Measurements of Rock Deformation and Failure in Triaxial Tests
The implementation of distributed strain measurement methods in triaxial and uniaxial tests have demonstrated the development of strain localization, even at early stages. This implies that single point measurement methods are location dependent. The use of distributed methods is required not only to improve the interpreted constitutive parameters obtained from triaxial tests, but also to understand the implications of strain localization in the failure process. Here, this work uses optical fibers in triaxial tests. The developed distributed measurement method was implemented on granite, gabbro, and sandstone samples and tested under different confining pressures, reaching 200 MPa on the granite sample. Using a temporal resolution of 0.25 Hz and 5 mm of spatial resolution, the strain evolution at over 300 locations at the sample surface was measured during testing. When compared to point sensing methods, the use of optical fiber greatly increases the number of measurements at the surface of the sample, and their interpolation provides the entire deformation of the sample surface. In all the tests performed, strain localizations were revealed before failure. A three-dimensional interpretation of a test, combining an optical scan of the sample and the distributed measurements, show good correlation between the fractures and the strain localization.
Enabling robust, stable, and accurate nonlinear optical measurements from squeezed light generated in hot rubidium vapor
The feasibility of nonlinear optical (NLO) imaging and spectroscopy using low intensity quantum states of light including entangled photon and squeezed light sources, such as those driven by two-photon absorption (TPA), has been a topic of ongoing debate. An unambiguous identification of the appreciable quantum advantage in such quantum light applications could enable NLO imaging of biological samples without photodegradation and phototoxicity. Recently, we have constructed a two-mode squeezed light source based on four-wave mixing in 85Rb vapor, which is capable of 7.9 dB of intensity-difference squeezing (IDS), corresponding to 8.7 dB upon electronic noise correction. In this talk, we discuss the stability of our system, including implementation details on achieving and maintaining 8.7 dB of IDS for several hours, and ensuring the two spatially multimode beams are properly overlapped in a sample with minimal optical loss.
Optical measure of disorder: Why Urbach analysis works for amorphous silicon but fails for amorphous carbon
We investigate the basis for the Paradox where the Urbach-slope disorder parameter disagrees with the Raman width in amorphous diamond-like carbon (DLC) materials (lower Urbach-Eo yet greater Raman width). We examined the bandgap and Urbach-slope measurement issues. While significant errors are identified, ultimately these cannot resolve the Paradox. This resolution involves large changes in shape of DLC's absorption band resulting from large energy shifts. To solidify the understanding of band energy shifts, we examined their properties using a-Si:H, well known for its agreement between Raman and Urbach-slope disorder parameters. Using Tauc-Lorentz (T-L) dispersion functions, the Urbach method works for a-Si:H because small changes in shape occur, as measured by (i) peak position, (ii) peak width, (iii) peak amplitude, and (iv) and gap energies. Moreover, for a-Si:H, a 5th condition (v) there is no other feature below the principal band to interfere with its fall. All 5 of these conditions fail for DLCs. Because T-L dispersions accommodate asymmetry, we traced the Paradox to a steepening of the band shape as it pushes toward lower energy. This steepening is unrelated to disorder, but to a boundary value problem where energy cannot be negative. We conclude that Urbach analysis is invalid for DLC materials, but the T-L width is a good measure instead. We also examined another disorder measure, where π bonds should be considered as disorder relative to the σ bonds in an idealized “amorphous diamond” sp 3 network: superconvergence can be used to quantify these π transitions. Finally, further molecular orbital calculations are needed to properly interpret the changes in T-L widths.