Spatiotemporal dispersion compensation for a 200-THz noncollinear optical parametric amplifier

A noncollinear optical parametric amplifier (NOPA) can produce few-cycle femtosecond laser pulses that are ideally suited for time-resolved optical spectroscopy measurements. However, the nonlinear-optical process giving rise to ultrabroadband pulses is susceptible to spatiotemporal dispersion problems. Here, we detail refinements, including chirped-pulse amplification (CPA) and pulse-front matching (PFM), that minimize spatiotemporal dispersion and thereby improve the properties of ultrabroadband pulses produced by a NOPA. Here, the description includes a rationale behind the choices of optical and optomechanical components, as well as assessment protocols. We demonstrate these techniques using a 1 kHz, second-harmonic Ti:sapphire pump configuration, which produces ~5-fs duration pulses that span from about 500 to 800 nm with a bandwidth of about 200 THz. To demonstrate the utility of the CPA-PFM-NOPA, we measure vibrational quantum beats in the transient–absorption spectrum of methylene blue, a dye molecule that serves as a reference standard.

47 OTHER INSTRUMENTATION↗

Effect of the pump beam profile and wavefront on the amplified signal wavefront in optical parametric amplifiers

We present a theoretical and experimental analysis of the signal phase introduced by the pump-beam wavefront and spatial profile during optical parametric amplification (OPA) process. The theory predicts the appearance of an additional wavefront in the amplified signal beam that is proportional to the spatial derivative of the pump-beam wavefront. The effect of the pump-beam profile on the signal-beam wavefront is also investigated. Our experiments tested these theoretical predictions by comparing the wavefront of the signal beam before and after amplification in a multi-joule broadband OPA. The measured signal wavefront was shown to have the expected dependence on the pump-beam profile and wavefront. These results can be considered when designing petawatt-scale ultrabroadband optical parametric chirped-pulse–amplification systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-Broad-Band Optical Parametric Amplifier or Oscillator

A concept for an ultra-broad-band optical parametric amplifier or oscillator has emerged as a by-product of a theoretical study in fundamental quantum optics. The study was originally intended to address the question of whether the two-photon temporal correlation function of light [in particular, light produced by spontaneous parametric down conversion (SPDC)] can be considerably narrower than the inverse of the spectral width (bandwidth) of the light. The answer to the question was found to be negative. More specifically, on the basis of the universal integral relations between the quantum two-photon temporal correlation and the classical spectrum of light, it was found that the lower limit of two-photon correlation time is set approximately by the inverse of the bandwidth. The mathematical solution for the minimum two-photon correlation time also provides the minimum relative frequency dispersion of the down-converted light components; in turn, the minimum relative frequency dispersion translates to the maximum bandwidth, which is important for the design of an ultra-broad-band optical parametric oscillator or amplifier. In the study, results of an analysis of the general integral relations were applied in the case of an optically nonlinear, frequency-dispersive crystal in which SPDC produces collinear photons. Equations were found for the crystal orientation and pump wavelength, specific for each parametric-down-converting crystal, that eliminate the relative frequency dispersion of collinear degenerate (equal-frequency) signal and idler components up to the fourth order in the frequency-detuning parameter

Strekalov, Dmitry↗

Ground Demonstration of Planetary Gas Lidar Based on Optical Parametric Amplifier

We report on the development effort of a nanosecond-pulsed optical parametric amplifier (OPA) for remote trace gas measurements for Mars and Earth. The OPA output has high spectral purity and is widely tunable both at near-infrared and mid-infrared wavelengths, with an optical-optica1 conversion efficiency of up to approx 39 %. Using this laser source, we demonstrated open-path measurements of CH4 (3291 nm and 1651 nm), CO2 (1573 nm), H2O (1652 nm), and CO (4764 nm) on the ground. The simplicity, tunability. and power scalability of the OPA make it a strong candidate for general planetary lidar instruments, which will offer important information on the origins of the planet's geology, atmosphere, and potential for biology,

Numata, Kenji↗

High-efficiency, single-stage tunable optical parametric amplifier for visible photocathode applications

In this work we present a single-stage optical parametric amplifier (OPA) with an average conversion efficiency up to 38%, tunable between 1.01 and 1.18 µm. The OPA seed is produced by a gain-managed nonlinear fiber amplifier. Numerical modeling of the seed pulse generation shows a linear chirp, a smoothly broadened redshifted spectrum, and a high spectral energy density. When up-converted to the visible through second-harmonic generation, the signal pulses are suitable for visible photocathode excitation.

14 SOLAR ENERGY↗

Ground and Airborne Methane Measurements with an Optical Parametric Amplifier

We report on ground and airborne atmospheric methane measurements with a differential absorption lidar using an optical parametric amplifier (OPA). Methane is a strong greenhouse gas on Earth and its accurate global mapping is urgently needed to understand climate change. We are developing a nanosecond-pulsed OPA for remote measurements of methane from an Earth-orbiting satellite. We have successfully demonstrated the detection of methane on the ground and from an airplane at approximately 11-km altitude.

Numata, Kenji↗

An Optical Parametric Amplifier for Profiling Gases of Atmospheric Interest

This paper describes the development of a lidar transmitter using an optical parametric amplifier. It is designed for profiling gases of atmospheric interest at high spatial and temporal precision in the near-IR. Discussions on desirable characteristics for such a transmitter with specific reference to the case of CO, are made.

Heaps, William↗

Ground and Airborne Methane Measurements using Optical Parametric Amplifiers

We report on an initial airborne demonstration of atmospheric methane column measurements at 1.65 micrometers using a widely tunable, seeded optical parametric amplifier (OPA) lidar and a photon counting detector. Methane is an important greenhouse gas and accurate knowledge of its sources and sinks is needed for climate modeling. Our lidar system uses 20 pulses at increasing wavelengths and integrated path differential absorption (IPDA) to map a methane line at 1650.9 nanometers. The wavelengths are generated by using a Nd:YAG pump laser at 1064.5 nanometers and distributed feedback diode laser at 1650.9 nanometers and a periodically-poled lithium niobate (PPLN) crystal. The pulse width was 3 nanoseconds and the pulse repetition rate was 6.28 KHz. The outgoing energy was approximately 13 microJoules/pulse. A commercial 20 nanometer diameter fiber-coupled telescope with a photon counting detector operated in analog mode with a 0.8 nanometer bandpass filter was used as the lidar receiver. The lidar system was integrated on NASA's DC-8 flying laboratory, based at Dryden Airborne operations Facility (DAOF) in Palmdale CA. Three flights were performed in the central valley of California. Each flight lasted about 2.5 hours and it consisted of several flight segments at constant altitudes at approximately 3, 4.5, 6, 7.6, 9.1, 10.6 km (l0, 15, 20, 25, 30, 35 kft). An in-situ cavity ring down spectrometer made by Picarro Inc. was flown along with the lidar instrument provided us with the "truth" i.e. the local CH4, CO2 and H2O concentrations at the constant flight altitude segments. Using the aircraft's altitude, GPS, and meteorological data we calculated the theoretical differential optical depth of the methane absorption at increasing altitudes. Our results showed good agreement between the experimentally derived optical depth measurements from the lidar instrument and theoretical calculations as the flight altitude was increased from 3 to 10.6 kilometers, assuming a constant methane mixing ratio of 1.8 parts per million. The in-situ spectrometer did not show any significant deviations from the ambient concentrations. Further analysis using meteorological data from the Global Modeling and Assimilation Office (http://gmao.gsfc.nasa.gov/) to derive the theoretical optical depth also showed good agreement with the experimentally derived values. The OPA lidar system with slight modifications has also been used to measure CO2, water vapor, and CO in the near and mid-infrared spectral regions on the ground.

Riris, Haris↗

Achieving 100 GW idler pulses from an existing petawatt optical parametric chirped pulse amplifier

Optical parametric chirped-pulse-amplification produces two broadband pulses, a signal and an idler, that can both provide peak powers >100 GW. In most cases the signal is used, but compressing the longer-wavelength idler opens up opportunities for experiments where the driving laser wavelength is a key parameter. This paper will describe several subsystems that were added to a petawatt class, Multi-Terawatt optical parametric amplifier line (MTW-OPAL) at the Laboratory for Laser Energetics to address two long-standing issues introduced by the use of the idler, angular dispersion, and spectral phase reversal. To the best of our knowledge, this is the first time that compensation of angular dispersion and phase reversal has been achieved in a single system and results in a 100 GW, 120-fs duration, pulse at 1170 nm.

47 OTHER INSTRUMENTATION↗

Degradation of temporal contrast from post-pedestal interference with a chirped pulse in an optical parametric amplifier

Pre-pedestal generation is observed in a 0.35-PW laser front end coming from a post-pedestal via instantaneous gain and pump depletion in an optical parametric amplifier during chirped-pulse amplification. Generalized simulations show how this effect arises from gain nonlinearity and applies to all optical parametric chirped-pulse–amplification systems with a post-pedestal. An experiment minimizing the effect of B -integral is used to isolate and study the newly observed conversion of a continuous post-pedestal into a continuous pre-pedestal. Matching numerical simulations confirm experimental results and additionally reveal how third-order dispersion largely controls the slope of the generated pre-pedestal.

47 OTHER INSTRUMENTATION↗

Asymmetric high energy dual optical parametric amplifier for parametric processes and waveform synthesis

We report on an asymmetric high energy dual optical parametric amplifier (OPA) which is capable of having either the idlers, signals, or depleted pumps, relatively phase locked at commensurate or incommensurate wavelengths. Idlers and signals can be locked on the order of 200 mrad rms or better, corresponding to a 212 as jitter at λ =2 µ m. The high energy arm of the OPA outputs a combined 3.5 mJ of signal and idler, while the low energy arm outputs 1.5 mJ, with the entire system being pumped with a 1 kHz, 18 mJ Ti:Sapphire laser. Both arms are independently tunable from 1080 nm-2600 nm. The combination of relative phase locking, high output power and peak intensity, and large tunability makes our OPA an ideal tool for use in difference frequency generation (DFG) in the strong pump regime, and for high peak field waveform synthesis in the near-infrared. To demonstrate this ability we generate terahertz radiation through two color waveform synthesis in air plasma and show the influence of the relative phase on the generated terahertz intensity. The ability to phase lock multiple incommensurate wavelengths at high energies opens the door to a multitude of possibilities of strong pump DFG and waveform synthesis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Optical Parametric Amplifier for Lidar Measurements of Trace Gases on Earth and Mars

Trace gases in planetary atmospheres offer important clues as to the origins of the planet's hydrology, geology. atmosphere. and potential for biology. Wc report on the development effort of a nanosecond-pulsed optical parametric amplifier (OPA) for remote trace gas measurements for Mars and Earth. The OP A output light is single frequency with high spectral purity and is widely tunable both at 1600 nm and 3300 nm with an optical-optical conversion efficiency of approximately 40%. We demonstrated open-path atmospheric measurements ofCH4 (3291 nm and 1651 nm). CO2 (1573 nm), H20 (1652 nm) with this laser source.

Numata, Kenji↗

Design and optimization of a high-energy optical parametric amplifier for broadband, spectrally incoherent pulses

Spectrally incoherent laser pulses with sufficiently large fractional bandwidth are in demand for the mitigation of laser–plasma instabilities occurring in high-energy laser–target interactions. Here, we modeled, implemented, and optimized a dual-stage high-energy optical parametric amplifier for broadband, spectrally incoherent pulses in the near-infrared. The amplifier delivers close to 400 mJ of signal energy through noncollinear parametric interaction of 100-nJ-scale broadband, spectrally incoherent seed pulses near 1053 nm with a narrowband high-energy pump operating at 526.5 nm. Mitigation strategies for high-frequency spatial modulations in the amplified signal caused by index inhomogeneities in the Nd:YLF rods of the pump laser are explored and discussed in detail.

47 OTHER INSTRUMENTATION↗

On-chip non-Hermitian optical parametric amplifiers with a large bandwidth

Recently, our groups have introduced the notion of optical parametric amplification based on non-Hermitian phase matching wherein the incorporation of loss can lead to gain in this nonlinear optical process. Previous simulation results using second-order nonlinear optical coupled-mode theory have demonstrated the potential of this technique as an alternative to the stringent phase-matching condition, which is often difficult to achieve in semiconductor platforms. Here we fortify this notion for the case of third-order nonlinearity by considering parametric amplification in silicon nanowires and illustrate the feasibility of these devices by employing rigorous finite-difference time-domain analysis using realistic materials and geometric parameters. Particularly, we demonstrate that by systematic control of the optical loss of the idler in a four-wave mixing process, we can achieve efficient unidirectional energy conversion from the pump to the signal component even when the typical phase-matching condition is violated. Importantly, our simulations show that a signal gain of ∼ <#comment/> 9 d B for a waveguide length of a few millimeters is possible over a large bandwidth of several hundreds of nanometers ( ∼ <#comment/> 600 n m ). This bandwidth is nearly 2 orders of magnitude larger than what can be achieved in the conventional silicon-photonics-based four-wave mixing process.

Ahmed, Asif (ORCID:0000000152234392)↗

Ground and Airborne Methane Measurements Using Optical Parametric Amplifiers

We report on ground and airborne methane measurements with an active sensing instrument using widely tunable, seeded optical parametric generation (OPG). The technique has been used to measure methane, CO2, water vapor, and other trace gases in the near and mid-infrared spectral regions. Methane is a strong greenhouse gas on Earth and it is also a potential biogenic marker on Mars and other planetary bodies. Methane in the Earth's atmosphere survives for a shorter time than CO2 but its impact on climate change can be larger than CO2. Carbon and methane emissions from land are expected to increase as permafrost melts exposing millennial-age carbon stocks to respiration (aerobic-CO2 and anaerobic-CH4) and fires. Methane emissions from c1athrates in the Arctic Ocean and on land are also likely to respond to climate warming. However, there is considerable uncertainty in present Arctic flux levels, as well as how fluxes will change with the changing environment. For Mars, methane measurements are of great interest because of its potential as a strong biogenic marker. A remote sensing instrument that can measure day and night over all seasons and latitudes can localize sources of biogenic gas plumes produced by subsurface chemistry or biology, and aid in the search for extra-terrestrial life. In this paper we report on remote sensing measurements of methane using a high peak power, widely tunable optical parametric generator (OPG) operating at 3.3 micrometers and 1.65 micrometers. We have demonstrated detection of methane at 3.3 micrometers and 1650 nanometers in an open path and compared them to accepted standards. We also report on preliminary airborne demonstration of methane measurements at 1.65 micrometers.

Numata, Kenji↗

Ground and Airborne Methane Measurements with an Optical Parametric Amplifier

Here we report on measurements made with an improved CO2 Sounder lidar during the ASCENDS 2014 and 2016 airborne campaigns. The changes made to the 2011 version of the lidar included incorporating a rapidly wavelength-tunable, step-locked seed laser in the transmittter, using a much more sensitive HgCdTe APD detector andusing an analog digitizer with faster readout time in the receiver. We also improved the lidar's calibration approach and the XCO2 retrieval algorithm. The 2014 and 2016 flights were made over several types of topographic surfaces from3 to 12 km aircraft altitudes in the continental US. The results are compared to the XCO2 values computed from an airborne in situ sensor during spiral-down maneuvers. The 2014 results show significantly better performance and include measurement of horizontal gradients in XCO2 made over the Midwestern US that agree with chemistry transport models. The results from the 2016 airborne lidar retrievals show precisions of 0:7 parts per million (ppm) with 1 s averaging over desert surfaces, which is an improvement of about 8 times compared to similar measurements made in 2011. Measurements in 2016 were also made over fresh snow surfaces that have lower surface reflectance at the laser wavelengths. The results from both campaigns showed that the mean values of XCO2 retrieved from the lidar consistently agreed with those based on the in situ sensor to within 1 ppm. The improved precision and accuracy demonstrated in the 2014 and 2016 flights should benefit future airborne science ampaigns and advance the technique's readiness for a spacebased instrument.

Numata, Kenji↗

Femtosecond wavelength-tunable laser system using gain managed nonlinear amplifier

Optical parametric amplifiers require a seed energy at the spectral range of interest for amplification. In the case of pulsed laser systems, seed pulse characteristics such as spectral energy density and spectral uniformity influence laser system design and performance. In this letter, we present the design and modeling of a few micro-joules, wavelength-tunable, femtosecond parametric amplifier system. We employ a gain-managed nonlinear fiber amplifier output as the seed pulse. This seed pulse is relatively uniform across its bandwidth from 1010 to 1180 nm. Its spectral energy density averages 600 pJ/nm, 30 times higher than conventional counterparts. The overall amplification gain is 175, and the conversion efficiency is 17.5%. The inherent quasi-linear chirp of the seed pulse is utilized to alter the output wavelength. Our tunable femtosecond laser is an enabling technology for high-demand applications such as time-resolved spectroscopy, nonlinear and advanced material research, and biomedical imaging and microscopy modalities.

47 OTHER INSTRUMENTATION↗

Fundamental limits to the generation of highly displaced bright squeezed light using linear optics and parametric amplifiers

High-quality squeezed light is an important resource for a variety of applications. Multiple methods for generating squeezed light are known, having been demonstrated theoretically and experimentally. However, the effectiveness of these methods—in particular, the inherent limitations to the signals that can be produced—has received little consideration. Here we present a comparative theoretical analysis for generating a highly displaced squeezed light from a linear optical method—a beamsplitter mixing a squeezed vacuum and a strong coherent state—and well-studied parametric amplification methods including an optical parametric oscillator, an optical parametric amplifier, and a dissipative optomechanical squeezer seeded with coherent states. We show that the quality of highly displaced squeezed states that can be generated using these methods is limited on a fundamental level by the physical mechanism utilized; across all methods there are significant trade-offs between displacement, squeezing, and overall uncertainty. We explore the nature and extent of these trade-offs specific to each mechanism and identify the optimal operation modes for each. Finally, we identify the conditions for minimum-uncertainty squeezing in arbitrary parametric amplifying systems and show that displacing the output signal will in general violate these conditions, adding noise and degrading squeezing. Published by the American Physical Society 2025

Young, Steve M. (ORCID:0000000173839366)↗