Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Optode performance data associated with: Metabolic Multireactor: practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments

This data package is associated with the publication “Metabolic Multireactor: practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments”, submitted to PlosONE (Kaufman et al. 2023; 10.1101/2023.03.28.534656).We carried out many testing and calibration experiments on a system of small oxygen consumption batch reactors designed for use with water and sediment samples for environmental questions. The oxygen sensing system is based very directly on the work of Larsen, et al. [2011], and similar oxygen sensing technology is widely used in the literature. Our primary focus was on practical considerations, such as temperature effects, lighting angle effects, sterilization, and other similar situations that a user may find useful. Most of the tests required comparing “base” calibration curves to “treatment” calibration curves to determine the extent to which the treatment impacted the reported measurements. This data package contains the performance and calibration data collected for that purpose.This dataset is comprised of one data folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) diffusion test result files; (5) limit of detection test result files; (6) temperature impact files; (7) a main data file that contains test results for all other tests; and (8) an R script that uses Kolmogorov-Smirnov tests to determine whether treatment calibrations are significantly different from their respective base calibrations. All files are .csv, .txt, .Rmd, or .pdf.

54 ENVIRONMENTAL SCIENCES↗

Development of a fully integrated analysis system for ions based on ion-selective optodes and centrifugal microfluidics

A fully integrated, miniaturized analysis system for ions based on a centrifugal microfluidics platform and ion-selective optode membranes is described. The microfluidic architecture is composed of channels, five solution reservoirs, a measuring chamber, and a waste reservoir manufactured onto a disk-shaped substrate of poly(methyl methacrylate). Ion-selective optode membranes, composed of plasticized poly(vinyl chloride) impregnated with an ionophore, a proton chromoionophore, and a lipophilic anionic additive, were cast, with a spin-on device, onto a support layer and then immobilized on the disk. Fluid propulsion is achieved by the centrifugal force that results from spinning the disk, while a system of valves is built onto the disk to control flow. These valves operate based on fluid properties and fluid/substrate interactions and are controlled by the angular frequency of rotation. With this system, we have been able to deliver calibrant solutions, washing buffers, or "test" solutions to the measuring chamber where the optode membrane is located. An analysis system based on a potassium-selective optode has been characterized. Results indicate that optodes immobilized on the platform demonstrate theoretical responses in an absorbance mode of measurement. Samples of unknown concentration can be quantified to within 3% error by fitting the response function for a given optode membrane using an acid (for measuring the signal for a fully protonated chromoionophore), a base (for fully deprotonated chromoionophore), and two standard solutions. Further, the ability to measure ion concentrations by employing one standard solution in conjunction with acid and base and with two standards alone were studied to delineate whether the current architecture could be simplified. Finally, the efficacy of incorporating washing steps into the calibration protocol was investigated.

NASA Discipline Life Sciences Technologies↗

Optode Images, and Dissolved Oxygen Data from Sand and Sediment Flow-through Column Experiments associated with: "2-D Imaging of Dissolved Oxygen Concentration in Flow-Through Sediment Columns"

This data package is associated with the publication "2-D Imaging of Dissolved Oxygen Concentration in Flow-Through Sediment Columns" submitted to Frontiers in Water (Garayburu-Caruso et al., 2022). This work presents a novel application of planar optode technology to sediment columns that allows the study of well-constrained flow fields without the need to assume completely homogeneous flow. We introduce a flow-through column with the interior coated in an oxygen sensing film and a series of sampling ports as a unique tool capable of capturing changes in dissolved oxygen (DO) at high frequency (10 s) and spatial (< 1 mm) resolution across the length of a column. In addition, we provide custom scripts that allows image processing steps to be automated and consistently reproduced over a variety of experimental conditions. This dataset is comprised of four folders (1) 01_Riverbed_Sediment_Experiment, (2) 02_Sand_Experiment, (3) 01_Riverbed_Sediment_Raw_Images, and (4) 02_Sand_Experiment_Raw_Images. 01_Riverbed_Sediment_Experiment contains (1) a subfolder with csv files that contain statistical parameters from the linear regressions applied to each optode image, (2) a subfolder with csv files from DO data measured by in-line sensors, (3) a subfolder with csv files containing column and injection specific input parameters for the image processing script, and (4) a subfolder with scripts used to process the images and create associated figures. 02_Sand_Experiment contains (1) a subfolder with csv files containing column and injection-specific input parameters for the image processing script, and (2) a subfolder with scripts used to process the images and create associated figures. 01_Riverbed_Sediment_Raw_Images (spited in 3 parts due to size) contains a subfolder with raw red, and green images from the optode system during the MilliQ Injection, Vanillin Injection or Vanillin + Sampling Injection respectively. 02_Sand_Experiment_Raw_Images contains a subfolder with raw red, and green images from the optode system. Outside of the main folders there is a csv containing file-level metadata and a csv data dictionary defining column headers for all csv files contained in the data package.

54 ENVIRONMENTAL SCIENCES↗

Metabolic multireactor: Practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments

We present a system for carrying out small batch reactor oxygen consumption experiments on water and sediment samples for environmental questions. In general, it provides several advantages that can help researchers achieve impactful experiments at relatively low costs and high data quality. In particular, it allows for multiple reactors to be operated and their oxygen concentrations to be measured simultaneously, providing high throughput and high time-resolution data, which can be advantageous. Most existing literature on similar small batch-reactor metabolic studies is limited to either only a few samples, or only a few time points per sample, which can restrict the ability for researchers to learn from their experiments. The oxygen sensing system is based very directly on the work of Larsen, et al. [2011], and similar oxygen sensing technology is widely used in the literature. As such we do not delve deeply into the specifics of the fluorescent dye sensing mechanism. Instead, we focus on practical considerations. We describe the construction and operation of the calibration and experimental systems, and answer many of the questions likely to come up when other researchers choose to build and operate a similar system themselves (questions we ourselves had when we first built the system). In this way, we hope to provide an approachable and easy to use research article that can help other researchers construct and operate a similar system that can be tailored to ask their own research questions, with a minimum of confusion and missteps along the way.

3D printing↗

Scalable, large-area optical sensing platform with compact light delivery and imaging system

An optode has a planar radiation guiding medium having a first planar surface and a second planar surface and one or more perimeter surfaces bounded by the first and second planar surfaces. An excitation energy source of the optode is configured to output into the radiation guiding medium first energy at a wavelength selected to excite a fluorophore. The optode also includes a photodetector configured to image at least a portion of the first planar surface of the radiation guiding medium by detecting second energy transmitted through the radiation guiding medium.

Zhang, Xufeng↗

From tides to seasons: How cyclic tidal drivers and plant physiology interact to affect carbon cycling at the terrestrial-estuarine boundary (Final technical report)

Coastal ecosystems are among the most biologically and biogeochemically active and diverse systems on Earth. Because they act as important linkages between terrestrial ecosystems and the open ocean, their incorporation in Earth system models (ESMs) is critical to predict coastal and global responses to environmental changes. However, they vary greatly in the magnitude of tides and the volume and timing of freshwater input from land, making it challenging to model the major biogeochemical reactions that control productivity and greenhouse gas emissions across coastal terrestrial aquatic interfaces (TAIs). Our overall objective was to improve mechanistic process understanding and modeling of tidal wetland hydro-biogeochemistry in coastal TAIs. We established a new flux tower site (Ameriflux US-PLo) in the oligohaline part of the Parker River to continuously monitor ecosystem-scale carbon fluxes under temporally varying salinity conditions. The site is co-located with long-term monitoring plots of the Plum Island Ecosystems LTER project. We installed wells and redox sensors in the marsh interior and creek bank, established biomass monitoring plots and deployed novel optode sensors in both locations. We used this data to parameterize plant-mediated transport in PFLOTRAN and tested the impact of soil heterogeneity on porewater constituents and gas fluxes. We collected observations of root oxygen release with a novel planar optode system in the field. Flux data collected during the measurement period encompasses a large variation in salinity ranging from drought to record precipitation years. We developed a method to extract functional relationships from the flux data using artificial neural networks, identifying salinity thresholds for CH 4 fluxes. Finally, we are using the coupled ELM-PFLOTRAN model to test the impact of antecedent hydrological conditions on the salinity-CH 4 flux relationship. This grant contributed to the professional development of one postdoc, three research assistants and one graduate student. The sensor data has been shared with external collaborators.

54 ENVIRONMENTAL SCIENCES↗

Water chemistry in flume channel and hyporheic zone (i.e., porewater) associated with: “Rethinking Aerobic Respiration in the Hyporheic Zone Under Variation in Carbon and Nitrogen Stoichiometry”

Dissolved oxygen (DO), total organic carbon (TOC), total nitrogen (TN), molecular data for organic matter, and biochemical reactions for surface water and porewater (i.e., hyporheic zone) collected from a water recirculating flume located at the University of Texas, Austin. The flume contained real river water from Lower Colorado River(Austin, TX) and clean sand. Hyporheic exchange in the flume was induced through The study aims to understand relationships between aerobic metabolism of organic matter and molecular characteristics of organic matter, such as thermodynamic signature and nitrogen content, through the extent of the hyporheic zone at 10 cm- resolution, and through time. During the experiment, organic matter (dry leaves) was added to the flume and removed after 24 hours. The water samples were collected before the addition of leaves, at the time of removal of leaves, and at hour 72. The water samples were analyzed using ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and total organic carbon (TOC) and total nitrogen (TN) analysis. Dissolved oxygen content throughout the surface water and the hyporheic zone of the flume was measured with a large planar optode. This data package is associated with the publication ’ Rethinking Aerobic Respiration in the Hyporheic Zone Under Variation in Carbon and Nitrogen Stoichiometry’ published in Environmental Science and Technology (Turețcaia et al., 2023 https://doi.org/10.1021/acs.est.3c04765). The dataset is comprised of five folders (1) Diss_O2_pic, (2) input_files (3) output_files; (4) python_code; and (5) R_code . Diss_O2_pic contains siximages of dissolved oxygen distribution in a bedform at hours 0, 24, and 72 of the experiment conducted in a large recirculation flume. Images are in separate R and G channels (i.e., RGB). The input_files contains (1) a csv file with FTICR peaks identified within each sample, (2) a csv file with molecular information pertinent to FTICR data with Gibbs free energy calculations adjusted for environmental temperature, (3) a csv file containing concentrations of non-purgeable organic carbon measured throughout the experiment , (4) a csv file containing concentrations of total nitrogen measured throughout the experiment, (5) a csv file containing total biochemical reactions (i.e., transformations) identified in the dataset, (6) a csv containing transformation profiles, and (7) a csv file containing transformations with formulas, and (8) a jpg file with schematic representation of locations for sample collection. The output_files contains (1) and xlsx file containing percent biochemical reactions containing nitrogen identified across all 39 sample, (2) a csv file of merged FTICR data and molecular information files, (3) a csv files containing average Gibbs free energy within sampling domains and at each sampling location, (4) a csv file with average concentrations of dissolved oxygen across sampling locations at hour 0, (5) a csv file with average concentrations of dissolved oxygen across sampling locations at hour 24, (6) a csv file with average concentrations of dissolved oxygen across sampling locations at hour 72, (7) a csv file with percent chemical classes identified across sampling locations at hour 0, (8) a csv file with percent chemical classes identified across sampling locations at hour 24, (9) a csv file with percent chemical classes identified across sampling locations at hour 72, and (10) a csv file containing percent nitrogen containing biochemical reactions identified across sampling locations at hours 0, 24, and 72. The python_code contains seven ipynb files which are Jupyter Notebooks used for data analysis and figures generation. The R_code contains 3 R files with R code used for data analysis and figures generation. This data package contains the processed data used in the associated manuscript. This data has not been previously published.

54 ENVIRONMENTAL SCIENCES↗

Root exudates induced coupled carbon and phosphorus cycling in a soil with low phosphorus availability

The amount and type of root exudates can influence P availability in the rhizosphere directly by desorption or dissolution of soil minerals, or indirectly by decomposition of soil organic matter (SOM). Here this study aimed to determine the mechanisms by which specific root exudates influence the distribution and availability of P in soils with low P availability. Water, glucose, alanine, and oxalate were delivered through a simulated root into soils for 15 days. Zymography and planar optodes were used to image potential phosphatase activity, and O2 and pH distribution, respectively. Soils were analyzed for resin extractable inorganic P (Pi), dissolved organic C (DOC), water soluble Fe, and Al, and microbial community structure. Characterization of SOM and P were conducted using ultra-high resolution mass spectrometry and 31P solution nuclear magnetic resonance (NMR), respectively. The addition of oxalate resulted in the greatest resin extractable Pi, DOC, and water-soluble Fe, and Al compared to the other exudates suggesting destabilization of mineral associated organic matter (MAOM) and release of organic P (Po). Both 31P solution NMR and ultra-high resolution mass spectrometry analysis provided evidence of mineralization of Po released from the destabilization of MAOM. The study demonstrates the important role microbial and plant-derived metal chelating ligands play in destabilizing MAOM, releasing SOM and importantly Po, that when mineralized may contribute to increasing Pi availability in soils with low P availability.

59 BASIC BIOLOGICAL SCIENCES↗

Utilisation of spatial derivative measurements in circular diffuse optical tomographic imaging to improve image resolution and contrast

The resolution of images recovered using diffuse optical tomography without spatial prior information is inherently limited due to the diffusive nature of light transport in scattering dominated biological tissue. Several studies have previously reported an improvement in depth sensitivity in near infrared spectroscopy by considering the subtraction of two neighbouring measurements. A nearest neighbour, spatial derivative based algorithm is presented, in which the difference between neighbouring source-sharing source – detector pairs is considered for tomographic reconstruction. Using a circular, inward-facing optode geometry, it is shown that deeper abnormalities in oxyhaemoglobin, deoxyhaemoglobin and water can be recovered with better localisation and contrast as compared to reconstructing using absolute values of multi-wavelength data. Relative improvements of up to 25 % in quantitative accuracy of recovered physiological values are demonstrated at better resolution for cancerous tissue in a heterogeneous breast model, when using this proposed spatial derivative based parameter reconstruction. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microminiature Monitor for Vital Electrolyte and Metabolite Levels of Astronauts

Ions, such as proton (pH) and potassium, play a crucial role in body fluids to maintain proper basic functioning of cells and tissues. Metabolites, such as glucose, control the energy available to the entire human body in normal as well as stress situations, and before, during, and after meals. These molecules diffuse easily between blood in the capillaries and the interstitial fluid residing between cells and tissues. We have developed and approach to monitoring of critical ions (called electrolytes) and glucose in the interstitial fluid under the human skin. Proton and potassium levels sensed using optode technology that translates the respective ionic concentrations into variable colors of corresponding ionophore/dye/polymeric liquid membranes. Glucose is monitored indirectly, by coupling through immobilized glucose oxidase with local pH that is then detected using a similar color scheme. The monitor consists of a tiny plastic bar, 100-200 microns wide and 1-2 mm long, placed just under the skin, with color changing spots for each analyte as well as blanks. The colors are read and translated into concentration values by a CCD camera. Direct optical coupling between the in vivo sensing bar and the ex vivo detector device requires no power, and thus eliminates the need for wires or optical fibers crossing the skin. The microminiature bar penetrates the skin easily and painlessly, so that astronauts could insert it themselves. The approach is fully compatible with telemetry in space, and thus, in vivo clinical data will be available real time in the Earth based command center once the device is fully developed. The information provided can be used for collecting hitherto unavailable vital data on clinical effects of space travel. Managing clinical emergencies in space with the sensor already in place should also become much more efficient than without a continuous monitor, as is currently the case. Civilian applications may include better glucose control of patients with moderate to severe diabetes: a growing health problem in the US and World-wide.

Tohda, Koji↗

Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters

Near-infrared spectroscopy (NIRS) can be used to noninvasively measure changes in the concentrations of oxy- and deoxyhemoglobin in tissue. We have previously shown that while global changes can be reliably measured, focal changes can produce erroneous estimates of concentration changes (NeuroImage 13 (2001), 76). Here, we describe four separate sources for systematic error in the calculation of focal hemoglobin changes from NIRS data and use experimental methods and Monte Carlo simulations to examine the importance and mitigation methods of each. The sources of error are: (1). the absolute magnitudes and relative differences in pathlength factors as a function of wavelength, (2). the location and spatial extent of the absorption change with respect to the optical probe, (3). possible differences in the spatial distribution of hemoglobin species, and (4). the potential for simultaneous monitoring of multiple regions of activation. We found wavelength selection and optode placement to be important variables in minimizing such errors, and our findings indicate that appropriate experimental procedures could reduce each of these errors to a small fraction (<10%) of the observed concentration changes.

Non-NASA Center↗