Search NASA⌕ Search

SEARCH · Search NASA

Results for “Organic glass scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Boron-loaded organic glass scintillators

Herein we report the progress towards an organic glass scintillator with fast and thermal neutron sensitivity providing “triple” pulse shape discrimination (PSD) through the inclusion of a boron-incorporated aromatic molecule. Here, the commercially available molecule 2-(p-tolyl)-1,3,2-dioxaborinane (TDB) can be readily synthesized in one step using inexpensive materials and incorporated into the organic glass scintillator at 20% by weight or 0.25% 10 B by mass. In addition, we demonstrate that TDB can be easily scaled up and formulated into organic glass scintillator samples to produce a thermal neutron capture signal with a light yield equivalent to 120.4 ± 3.7 keVee, which is the highest value reported in the literature to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic glass scintillator bars with dual-ended readout

Organic glass scintillator (OGS) bars (6 × 6 × 50 mm 3 ) were melt-cast and characterized with dual-ended readout by silicon photomultiplier arrays. The results were compared to trans-stilbene bars of the same size. Energy resolution was measured via a 137 Cs Compton-coincidence experiment. Time resolution was determined via a 22 Na coincidence-timing experiment. Depth-of-interaction resolution was measured by moving a gamma ray fan beam along the major axis of the bars. Pulse shape discrimination capability and neutron light output were determined via a time-of-flight measurement of a 252 Cf source. The OGS bars exhibited better energy resolution at 478 keV (10.3 ± 0.5% vs. 11.2 ± 0.5%), better time resolution from 200–341 keVee (270 ps vs. 340 ps FWHM), slightly poorer depth-of-interaction resolution, poorer PSD performance, and higher neutron light output than the stilbene bars. Here, the low cost, ease of manufacturing, brightness, and excellent time resolution make OGS a strong candidate for use in compact radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Imaging Using Organic Glass Scintillators

In this work, we develop of a compact neutron imaging system based on organic glass scintillator and silicon photomultiplier arrays. The recently developed organic glass scintillator has excellent neutron and gamma-ray detection efficiency and exhibits pulse shape discrimination capability that is nearly as good as current state-of-the-art materials such as trans-stilbene. We have cast and characterized 6 mm by 6 mm by 50 mm bars of organic glass in our laboratory. When coupled to a silicon photomultiplier array, these bars demonstrated better energy and timing resolution than the stilbene organic scintillator. Here, this performance makes organic glass an ideal material for a compact neutron imaging system, which must resolve neutron scatter events on a sub-nanosecond time scale. We have demonstrated neutron imaging with bars of organic glass scintillator coupled to arrays of silicon photomultipliers. Additional bars of organic glass will be implemented into the system to improve the efficiency and imaging performance. The resulting system will be demonstrated using 252 Cf and PuBe neutron sources in our laboratory. In addition, we will compare imaging performance to other compact neutron imaging systems that exist in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detection efficiency measurements of organic glass scintillator arrays

We characterize the neutron detection efficiency of pixelated organic glass scintillator (OGS) arrays manufactured in two ways: an additive method in which the OGS is cast in place in a pixelated mold, and a subtractive method in which the scintillator is first cast as a large block before being cut in bars and bonded together to form the array. The cast-in-place array utilizes a mixture of “bis(9,9-dimethyl-9H-fluoren-2-yl)diphenylsilane” (P2), “tri([1,1'-biphenyl]-4-yl)(phenyl)silane” (PB3), and “4-bis(2-methylstyryl)benzene” (MSB), and 50% by weight of polystyrene is added to the mixture for subtractive manufactured array. We compare the performance of the OGS arrays to that of an EJ-299-33M plastic scintillator array that was manufactured using a subtractive process similar to that of the second OGS array.

Neutron detectors (cold, thermal, fast neutrons)↗

Neutron and Gamma-Ray Imaging of Th-232 and Cm-244 Using Organic Glass Scintillators

Modern nuclear safeguards require detection and characterization capabilities suitable for a wide variety of radiation sources and applications. Field-deployable detection systems have also had to modernize to meet changing needs. Recent developments in organic scintillator technology have resulted in the creation of an organic glass scintillator (OGS) at Sandia National Laboratory which is composed of a 9:1 mixture of glass compounds C42H36Si and C51H44Si. The novel scintillator composition was implemented into the design for a dual-particle capable imaging system at the University of Michigan. This work presents new results from two experiments demonstrating the gamma-ray and fast-neutron imaging capabilities of the organic glass system. Gamma spectroscopy was also performed using CeBr3 scintillators that are part of the imager design. Measurements were performed at Lawrence Livermore National Laboratory using 232Th metal hemishells and an encapsulated 244Cm oxide source. Successful gamma-ray imaging of the 232Th distributed sources is demonstrated with the glass imager, but there were no appreciable neutrons from the 232Th for neutron imaging. Promising neutron and gamma-ray imaging results of 244Cm are demonstrated despite limited imaging event statistics available in this measurement. Gamma-ray spectroscopy results were able to identify 232Th using prominent emissions at 239, 338, 583, and 911 keV. 244Cm was identified from emissions of 43, 99, and 153 keV. These results demonstrate the potential of organic glass imaging for nuclear nonproliferation or characterization efforts.

Lopez, Ricardo [Univ. of Michigan, Ann Arbor, MI (↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗