Search NASA⌕ Search

SEARCH · Search NASA

Results for “Over-sized”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improving Primary Frequency Response to Support Networked Microgrid Operations

Individual microgrids have proven their ability to provide uninterrupted power to critical end-use load during severe events. Building on the performance of individual microgrids during extreme events, there has been an increasing interest in the operations of network microgrids. By networking microgrids during extreme events, it is possible to share resources, increase the duration for which they can operate islanded, and increase the resiliency of critical end-use loads. While there are benefits to networking the operations of resiliency-based microgrids, the switching operations that they require introduce transients which can result in a loss of dynamic stability. The issue of dynamic stability is especially acute in microgrids with high penetrations of inverter-connected generation, and a correspondingly low system inertia. While the low-inertia of these microgrids can be increased by over-sizing the rotating generators, the increased capital and operating costs can become a barrier to deployment. This work will present a method of augmenting primary frequency controls to support the switching transients necessary for the operation of networked microgrids, without the need to over-size rotating machines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel consumption impacts of auto roof racks

The after-market roof rack is one of the most common components attached to a vehicle for carrying over-sized items, such as bicycles and skis. It is important to understand these racks' fuel consumption impacts on both individual vehicles and the national fleet because they are widely used. We estimate the national fuel consumption impacts of roof racks using a bottom-up approach. Our model incorporates real-world data and vehicle stock information to enable assessing fuel consumption impacts for several categories of vehicles, rack configurations, and usage conditions. In addition, the model draws on two new data-gathering techniques, on-line forums and crowd-sourcing. The results show that nationwide, roof racks are responsible for 0.8‰ of light duty vehicle fuel consumption in 2015, corresponding to 100 million gallons of gasoline per year. Sensitivity analyses show that results are most sensitive to the fraction of vehicles with installed roof racks but carrying no equipment. Here, the aerodynamic efficiency of typical roof racks can be greatly improved and reduce individual vehicle fuel consumption; however, government policies to minimize extensive driving with empty racks--if successful--could save more fuel nationally.

30 DIRECT ENERGY CONVERSION↗

24 GHz microwave mode converter optimized for superconducting ECR ion source SECRAL

Over-sized round waveguide with a diameter about Ø33.0 mm excited in the TE{sub 01} mode has been widely adopted for microwave transmission and coupling to the ECR (Electron Cyclotron Resonance) plasma with the superconducting ECR ion sources operating at 24 or 28 GHz, such as SECRAL and VENUS. In order to study the impact of different microwave modes on ECRH (Electron Cyclotron Resonance Heating) efficiency and especially the production of highly charged ions, a set of compact and efficient TE{sub 01}-HE{sub 11} mode conversion and coupling system applicable to 24 GHz SECRAL whose overall length is 330 mm has been designed, fabricated and tested. Good agreements between off-line tests and calculation results have been achieved, which indicates the TE{sub 01}-HE{sub 11} converter meets the application design. The detailed results of the optimized coupling system will be presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HT Lyn and IR Lyn: Two Semi-detached-type Near-contact Binaries with Stable Orbital Period

Abstract We presented the first photometric and orbital period investigations for two near-contact binaries: HT Lyn and IR Lyn. The light-curves solutions derived from both our ground-based and various surveys’ observations suggested that HT Lyn and IR Lyn are two semi-detached-type near-contact binaries with the secondary and primary components filling the Roche lobe. Combining the eclipse timings derived from several surveys’ data and our observations with those reported in the literature, we modified the orbital periods and revealed that their orbital periods were stable for the last two decades. The absolute physical parameters were well determined by using the empirical relations and the Gaia-distance-based method. Similar to other near-contact binaries, the primary components of HT Lyn and IR Lyn are evolving at the main-sequence stage, while their less-massive secondary components show the over-sized and over-luminosity features and should be more evolved than their primary ones. Combining the stable orbital period with the semi-detached configurations, we infer that the two near-contact binaries may be just located in the critical phase and evolving from the current semi-detached phase to the detached or contact one.

Astronomy & Astrophysics↗

Analysis of Conduction Cooling Strategies for Wire Arc Additive Manufacturing

Metal additive manufacturing (AM) processing consists of numerous parameters which take time to optimize for various geometries. One aspect of the metal AM process that continues to be explored is the control of thermal energy accumulation during component manufacturing due to the melting and solidification of the feedstock. Excessive energy accumulation causes thermal failure of the component while minimal energy accumulation causes lack of fusion with the build plate or previous layer. The ability to simulate the thermal response of an AM component can increase research efficiency by reducing the time to optimize thermal energy accumulation. This paper presents an effective implementation of finite element analysis to determine the thermal response of a wire arc additive manufactured component with various build plate sizes and cooling methods including, integral build plate cooling, oversized build plates with passive cooling, and non-integral build plate cooling. The use of integral build plate cooling channels was shown to decrease the interpass temperature at the conclusion of the build process by 55% and build plate temperature by 96% compared to the conventionally deposited sample with 20 second dwell time. The use of a tall build plate with passive cooling was shown to reduce the interpass temperature by 32% as compared to the conventionally deposited sample with 20 second dwell time. Each cooling strategy evaluated decreased the interpass temperature within a range of 20–55% which enables higher deposition rates and decreased dwell times during depositions. The cooling strategies are designed to be implemented in a hybrid or retrofit AM platform to mitigate concerns of the thermal input from the additive process having detrimental effects on the precision of the machining process. This paper shows that accurate simulations of all strategies can be used to accurately predict the thermal response of the various strategies discussed. These cooling strategies will allow for increased deposition rates with comparable interpass temperature and decreased dwell time, increasing deposition efficiency. This model and these simulations are verified by experimental results. It is concluded that passive strategies, such as the over-sized tall build plate, can be used when liquid coolant in the AM environment could negatively affect the deposition process. Active cooling strategies, such as the integral build plate cooling could be used if low thermal conductivity materials are deposited or higher material deposition rates are desired. This paper discusses the use of active and passive cooling used during AM and shows how a simulation model can be used to make design choices for cooling strategies. The model also enables verification of select critical process parameters such as dwell times for a desired interpass temperature.

Heinrich, Lauren↗

Acceptance Test Data for BWXT Coated Particle Batch 93164A Defective IPyC Fraction and Pyrocarbon Anisotropy

Coated particle fuel batch J52O-16-93164 was produced by Babcock and Wilcox Technologies (BWXT) for possible selection as fuel for the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-5/6/7 irradiation test in the Idaho National Laboratory (INL) Advanced Test Reactor (ATR), or may be used as demonstration production-scale coated particle fuel for other experiments. The tristructural-isotropic (TRISO) coatings were deposited in a 150-mm-diameter production-scale fluidizedbed chemical vapor deposition (CVD) furnace onto 425-μm-nominal-diameter spherical kernels from BWXT lot J52L-16-69316. Each kernel contained a mixture of 15.5%-enriched uranium carbide and uranium oxide (UCO) and was coated with four consecutive CVD layers: a ~50% dense carbon buffer layer with 100-μm-nominal thickness, a dense inner pyrolytic carbon (IPyC) layer with 40-μm-nominal thickness, a silicon carbide (SiC) layer with 35-μm-nominal thickness, and a dense outer pyrolytic carbon (OPyC) layer with 40-μm-nominal thickness. The TRISO-coated particle batch was sieved to upgrade the particles by removing over-sized and under-sized material, and the upgraded batch was designated by appending the letter A to the end of the batch number (i.e., 93164A).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Acceptance Test Data for Candidate AGR-5/6/7 TRISO Particle Batches BWXT Coater Batches 93165 93172 Defective IPyC Fraction and Pyrocarbon Anisotropy

Coated particle fuel batches J52O-16-93165, 93166, 93168, 93169, 93170, and 93172 were produced by Babcock and Wilcox Technologies (BWXT) for possible selection as fuel for the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-5/6/7 irradiation test in the Idaho National Laboratory (INL) Advanced Test Reactor (ATR). Some of these batches may alternately be used as demonstration coated particle fuel for other experiments. Each batch was coated in a 150-mm-diameter production-scale fluidized-bed chemical vapor deposition (CVD) furnace. Tristructural isotropic (TRISO) coatings were deposited on 425-μm-nominal-diameter spherical kernels from BWXT lot J52R-16-69317 containing a mixture of 15.5%-enriched uranium carbide and uranium oxide (UCO). The TRISO coatings consisted of four consecutive CVD layers: a ~50% dense carbon buffer layer with 100-μm-nominal thickness, a dense inner pyrolytic carbon (IPyC) layer with 40-μm-nominal thickness, a silicon carbide (SiC) layer with 35-μm-nominal thickness, and a dense outer pyrolytic carbon (OPyC) layer with 40-μmnominal thickness. The TRISO-coated particle batches were sieved to upgrade the particles by removing over-sized and under-sized material, and the upgraded batches were designated by appending the letter A to the end of the batch number (e.g., 93165A).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Acceptance Test Data for the AGR-5/6/7 Irradiation Test Fuel Composite Defective IPyC Fraction and Pyrocarbon Anisotropy

Coated particle composite J52R-16-98005 was produced by Babcock and Wilcox Technologies (BWXT) as fuel for the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-5/6/7 irradiation test in the Idaho National Laboratory (INL) Advanced Test Reactor (ATR). This composite was comprised of four coated particle fuel batches J52O-16-93165B (26%), 93168B (26%), 93169B (24%), and 93170B (24%), chosen based on the Quality Control (QC) data acquired for each individual candidate AGR-5/6/7 batch. Each batch was coated in a 150-mm-diameter production-scale fluidized-bed chemical vapor deposition (CVD) furnace. Tristructural isotropic (TRISO) coatings were deposited on 425-μm-nominal-diameter spherical kernels from BWXT Lot J52R-16-69317 containing a mixture of 15.5%-enriched uranium carbide and uranium oxide (UCO). The TRISO coatings consisted of four consecutive CVD layers: a ~50% dense carbon buffer layer with 100-μm-nominal thickness, a dense inner pyrolytic carbon (IPyC) layer with 40-μm-nominal thickness, a silicon carbide (SiC) layer with 35-μm-nominal thickness, and a dense outer pyrolytic carbon (OPyC) layer with 40-μm-nominal thickness. The TRISO-coated particle batches were sieved to upgrade the particles by removing over-sized and under-sized material, and the upgraded batches were designated by appending the letter A to the end of the batch number (e.g., 93165A). Secondary upgrading by sieving was performed on the A-designated batches to remove particles with missing or very-thin buffer layers that were identified during previous analysis of the individual batches for defective IPyC, as reported in the acceptance test data report for the AGR-5/6/7 production batches [Hunn et al. 2017]. The additionally-upgraded batches were designated by appending the letter B to the end of the batch number (e.g., 93165B).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

X-ray Analysis of Defects and Anomalies in AGR-5/6/7 TRISO Particles

Coated particle fuel batches J52O-16-93164, 93165, 93166, 93168, 93169, 93170, and 93172 were produced by Babcock and Wilcox Technologies (BWXT) for possible selection as fuel for the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-5/6/7 irradiation test in the Idaho National Laboratory (INL) Advanced Test Reactor (ATR), or may be used for other tests. Each batch was coated in a 150-mm-diameter production-scale fluidized-bed chemical vapor deposition (CVD) furnace. Tristructural isotropic (TRISO) coatings were deposited on 425-μm-nominal-diameter spherical kernels from BWXT lot J52R-16-69317 containing a mixture of 15.4%-enriched uranium carbide and uranium oxide (UCO), with the exception of Batch 93164, which used similar kernels from BWXT lot J52L-16-69316. The TRISO-coatings consisted of a ~50% dense carbon buffer layer with 100-μmnominal thickness, a dense inner pyrolytic carbon (IPyC) layer with 40-μm-nominal thickness, a silicon carbide (SiC) layer with 35-μm-nominal thickness, and a dense outer pyrolytic carbon (OPyC) layer with 40-μm-nominal thickness. Each coated particle batch was sieved to upgrade the particles by removing over-sized and under-sized material, and the upgraded batch was designated by appending the letter A to the end of the batch number (e.g., 93164A). Secondary upgrading by sieving was performed on the upgraded batches to remove specific anomalies identified during analysis for Defective IPyC, and the upgraded batches were designated by appending the letter B to the end of the batch number (e.g., 93165B). Following this secondary upgrading, coated particle composite J52R-16-98005 was produced by BWXT as fuel for the AGR Program’s AGR-5/6/7 irradiation test in the INL ATR. This composite was comprised of coated particle fuel batches J52O-16-93165B, 93168B, 93169B, and 93170B.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acceptance Test Data for BWXT Coated Particle Batches 93172B and 93173B—Defective IPyC and Pyrocarbon Anisotropy

Coated particle batches J52O-16-93172B and J52O-16-93173B were produced by Babcock and Wilcox Technologies (BWXT) as part of the production campaign for the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-5/6/7 irradiation test in the Idaho National Laboratory (INL) Advanced Test Reactor (ATR), but were not used in the final fuel composite. However, these batches may be used as demonstration production-scale coated particle fuel for other experiments. Each batch was coated in a 150-mm-diameter production-scale fluidized-bed chemical vapor deposition (CVD) furnace. Tristructural isotropic (TRISO) coatings were deposited on 425-μm-nominal-diameter spherical kernels from BWXT lot J52R-16-69317 containing a mixture of 15.5%-enriched uranium carbide and uranium oxide (UCO). The TRISO coatings consisted of four consecutive CVD layers: a ~50% dense carbon buffer layer with 100-μm-nominal thickness, a dense inner pyrolytic carbon (IPyC) layer with 40-μm-nominal thickness, a silicon carbide (SiC) layer with 35-μm-nominal thickness, and a dense outer pyrolytic carbon (OPyC) layer with 40-μm-nominal thickness. The TRISO-coated particle batches were sieved to upgrade the particles by removing over-sized and under-sized material, and the upgraded batches were designated by appending the letter A to the end of the batch number (e.g., 93172A). Secondary upgrading by sieving was performed on the A-designated batches to remove particles with missing or very-thin buffer layers that were identified during previous analysis of the individual batches for defective IPyC, as reported in the acceptance test data report for the AGR-5/6/7 production batches [Hunn et al. 2017b]. The additionally-upgraded batches were designated by appending the letter B to the end of the batch number (e.g., 93172B).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating Utility-Scale PV-Battery Hybrids in an Operational Model for the Bulk Power System

Systems that combine solar photovoltaic and battery energy storage technologies (PV-BES) are increasingly being proposed and deployed on the bulk power system. The operations and value of PV-BES systems have been extensively studied from the project developer's perspective through analyses that maximize plant-level revenue. However, PV-BES hybrids' operational characteristics are seldom studied from the perspective of bulk power system operators, who seek to optimize the performance of a suite of generation and storage assets that are connected via the transmission network. This work presents modeling approaches for representing and evaluating PV-BES hybrids in a model that optimizes operations across the bulk power system. Its novel contributions include demonstrating a technique to modify a unit commitment and dispatch model to represent the operational synergies of PV-BES hybrids. In particular, we describe the challenges and an approach for representing so-called DC-coupled PV-BES - which utilize a single bi-directional inverter - as a dispatchable resource in a commercial, production cost model (PCM), PLEXOS. We demonstrate this technique in a PCM study of the Los Angeles Department of Water and Power (LADWP) test system, by replacing existing PV and battery generators on the test system with our PV-BES hybrids. We then pursue scenario analysis that is designed to isolate the various drivers of operational strategies for DC-coupled PV-BES hybrids, including the nature of coupling, PV penetration on the system, and varying inverter loading ratios (or degrees of over-sizing of the PV field). Results from the analysis include utilization profiles for the PV DC energy across available pathways, dispatch profiles for the battery component, and the hybrid technologies' impacts on system-wide production costs. The approach presented in this paper can be used in any PCM that is looking to study PV-BES hybrids as a resource in different power system configurations and services.

14 SOLAR ENERGY↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summary of GAIN BWR Off-Gas Study: Effect of Charcoal on Kr and Xe Delay

This is a summary of a more extensive report, written in collaboration with the GE-Hitachi BWR Owner's Group, detailing a study of BWR off-gas treatment. The study determined that aged charcoal continues to be effective for the delay of Kr and Xe through BWR off-gas treatment systems. It demonstrates the over-sized nature of existing charcoal beds, and highlights potential areas of improvement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluating the resilience benefits of marine energy in microgrids

Marine energy resources could promote clean energy and resilience of coastal and island microgrids, and thus, these applications are a key future market for marine energy development. To demonstrate these benefits, this paper illustrates how inclusion of wave resources into energy resilience solutions can improve overall grid efficiency and sustainability, as well as maintain electricity supply during grid outages. The paper describes a case study evaluation of the potential to add wave energy to the Moloka'i grid as Hawaii strives to meet a 100% clean energy target. The Microgrid Component Optimization for Resilience tool is used to simulate operation in off-grid conditions and size different combinations of wave, solar photovoltaic (PV), wind, storage, and fuel resources required to meet resilience objectives. This research investigates how including wave resources in a microgrid contributes to reducing or eliminating biofuel generation, producing a zero-greenhouse gas emission profile in the latter case, and avoiding the over-sizing of PV and battery systems to accommodate periods of unavailability or high demand. Insight from this paper supports the value proposition of wave resources for future markets and informs the relationship between marine generators and microgrids or isolated grids.

16 TIDAL AND WAVE POWER↗

Evaluating the resilience benefits of marine energy in microgrids

Marine energy resources could promote clean energy and resilience of coastal and island microgrids, and thus, these applications are a key future market for marine energy development. To demonstrate these benefits, this paper illustrates how inclusion of wave resources into energy resilience solutions can improve overall grid efficiency and sustainability, as well as maintain electricity supply during grid outages. The paper describes a case study evaluation of the potential to add wave energy to the Moloka’i grid as Hawaii strives to meet a 100% clean energy target. The Microgrid Component Optimization for Resilience tool is used to simulate operation in off- grid conditions and size different combinations of wave, solar photovoltaic (PV), wind, storage, and fuel resources required to meet resilience objectives. This research in- vestigates how including wave resources in a microgrid contributes to reducing biofuel generation, producing a zero-greenhouse gas emission profile, and avoiding the over-sizing of PV and battery systems to accommodate periods of unavailability or high demand. Insight from this paper supports the value proposition of wave resources for future markets and informs the relationship between marine generators and microgrids or isolated grids.

Newman, Sarah F.↗

Augmented Monitoring and Condition Assessment Program for SNF Wet Storage Life Extension - 20489

Approximately 27 MTHM of spent nuclear fuel (SNF) owned and managed by the U.S. Department of Energy, Office of Environmental Management is stored in the L Basin at the Savannah River Site (SRS). This 'DOE SNF' is comprised of approximately 12,000 aluminum-clad, aluminum-based fuel assemblies (∼7 MTHM), and approximately 2000 non-aluminum fuel assemblies (∼20 MTHM). A program is in progress to perform Non-Destructive Examination (NDE) of the fuel and their storage containers to characterize the materials' condition, and to evaluate the effects of service to enable continued safe wet storage of the SNF. The Augmented Monitoring and Condition Assessment Program (AMCAP), a two-part program to develop and implement remote underwater Non-Destructive Examination of the aluminum SNF, and of the containers of the non-aluminum SNF, respectively, is aimed at the characterization and evaluation of corrosion degradation of aluminum fuel and container materials. The predominant design of the aluminum SNF (ASNF) stored in L Basin is the Materials Test Reactor (MTR) equivalent design, a plate fuel design. These SNF are stored in 5'' diameter tubes or 5'' x 5'' squares (called bundles) that are nominally 12' or up to 14' long. The SNF is de-bundled and inspected using a custom-designed MTR Fuel Inspection Table. The inspection table provides for indexed fuel positioning for a video camera examination with controlled lighting. A total of 10 of the SNF originating from foreign research and test reactors were selected for examination based on burnup, enrichment, and prior damage caused by service/storage history. A special inspection campaign of these 10 assemblies is in progress. The observed corrosion damage included minor to moderate attack from general corrosion, pitting, crevice, end grain and galvanic corrosion. Example results from the completed inspections are shown and discussed. The focus is a comparison of the as-received condition versus the as-found current storage condition that will serve to validate Water Chemistry and Corrosion Monitoring Programs. The non-aluminum SNF (NASNF) stored in L Basin are of diverse design that includes various geometries with claddings of stainless steel, Zircaloy, and Hastelloy. The fuel core materials include uranium alloys, oxides/mixed oxides, and carbides. These SNF materials, originating from early experimental and test reactors, are in various physical forms including single fuel elements and cut pieces. The fuel is stored in L Basin in various configurations including in direct bundled storage in aluminum tubes and in isolation cans that are in the bundles or in a larger over-size storage container (OSC). Concern with inside-out corrosion and the potential loss of configuration control and ability to handle the storage containers prompted the development of remote NDE methods that include visual and UT technologies to assess the condition of the containers. Candidate stored materials were selected for a special inspection campaign; the development of the NDE methods for the inspection for galvanic, crevice and sediment-induced corrosion (inside-out) are discussed. A summary of the SNF storage in L Basin at the SRS, and an overview of the AMCAP to enable continued safe storage of DOE SNF are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis and design of DC-link capacitor in cascaded H-bridge multilevel active front-end converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. DC-link capacitors come with an expiration date which is dependent on the operating power and voltage values. Lack of information about the lifetime of the dc-link capacitor creates uncertainty in the duration of online operation of the converter, thus increasing the probability of a contingency outage. The lifetime of the capacitor can range from only a few seconds of online operation of the station due to under-sizing, to a compromised quality of power flowing through other solid state devices which may not have been designed for the transients that are caused by over-sizing of the dc-link capacitor. A better estimate of the lifetime of these capacitors can help maximize usage and maintain scheduled outages more efficiently, without disruption in service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-Load Space Conditioning Needs Assessment

Heating, ventilating, and air-conditioning (HVAC) equipment must be right-sized to ensure energy performance and comfort. With limited low-load options in the HVAC market, many new-construction housing units are being fitted with oversized equipment that creates system efficiency, comfort, and cost penalties. To bridge the gap between currently available HVAC equipment that is oversized or inefficient and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of the needs of the multifamily building and attached single-family (duplex and townhouse) home market. Over the past decade, Steven Winter Associates, Inc. (SWA) has provided certification and consulting services for hundreds of housing projects and has accrued a large pool of data that describe multifamily and attached single-family home characteristics. The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) compiled and analyzed these data to outline the characteristics of low-load dwellings such as the heating and cooling design loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗