A Flexible and Secure Evaluation Platform for Overvoltage Protection in Power Electronics Systems

This paper summarizes the fault mechanisms specifically for the overvoltage protection schemes in power electronic converters and the resulted power electronics enabled systems. A flexible and secure evaluation platform for overvoltage protection, has also been presented based on this conceptual mechanism. The proposed platform aims at testing the protection performance of distinctive overvoltage protection schemes. It would be applied to verify the effectiveness, identify potential strengths and weaknesses, and obtain the most critical protection response time to provide sufficient engineering insights for the designer. The operation principle and detailed design guideline have been presented first. The comprehensive component stress has been analyzed. An intensive set of LTSpice simulations have been conducted to show the validity of the proposed assessment approach.

Zheng, Sheng↗

Overvoltage protection network

Electrical equipment to be protected from overvoltage is connected with a possible source of overvoltage via an input conductor. A fuse is connected in series with the input conductor. A spark gap is connected between the input conductor and ground for conducting the overvoltage current to ground and for blowing the fuse to open the circuit to the electrical equipment. A pulse attenuator network is provided between the spark gap and the electrical equipment to be protected for attenuating the pulse of energy passing through the fuse and spark gap prior to blowing of the fuse. The pulse attenuator network includes additional shunt spark gaps, series inductance, and a series connection of a twisted shielded pair of conductors having low-voltage insulation.

Cambra, J. M.↗

A Fast-Response High-Accuracy Overvoltage Protection Circuit for Soft-Switching Current-Source Converters

Although voltage-source converters (VSCs) have been a focus of research for decades and are widely applied in numerous applications, they face great challenges in short-circuit failures, high dv/dt and electromagnetic interference (EMI), especially using wide bandgap devices. Instead, current-source converters (CSCs) are attracting increasing attention in recent years owing to their friendliness to short-circuit faults, improved EMI, etc. For CSCs, overvoltage is the most catastrophic failure since the semiconductor devices can hardly withstand an overvoltage for a short pulse. In this paper, a fast-response high-accuracy overvoltage protection (OVP) circuit is proposed to protect CSCs from overvoltage damage. It also features a small form factor, good noise-immunity, friendly retrofit capability, and no need for active switches. In this paper, the operating principle and design guideline of the proposed OVP circuit is introduced. Its effectiveness is validated in soft-switching solid-state transformer (S4T) at 500 V. In experiments, the voltage detection error of less than 5% and a propagation delay of fewer than 400 ns have been achieved.

30 DIRECT ENERGY CONVERSION↗

Alternative 3V0 Development for Ground Fault Overvoltage Protection with DERs/Renewables Interconnection (Final Report)

The ground fault overvoltage (GFOV) and the required traditional 3V0 installation has become a concerned issue for renewable/DER integration. Based on the alternative 3V0 methodology proposed by the PI and the feasibility study awarded by DOE SBIR/STIR project (Award No. DE-SC0018888), APS and RPI investigated development of a low-cost alternative 3V0 product based on the surge arrester current monitoring. The alternative 3V0 feasibility study completed by APS and RPI has verified that the alternative 3V0 is an effective solution (possibly the only one) under various circuit conditions and is competitive to traditional 3V0 methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rectenna array measurement results

The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining are demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array are demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

Dickinson, R. M.↗

Rectenna array measurement results

The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining were demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

Dickinson, R. M.↗

High voltage switch with cascaded transistor topology

A switching apparatus includes three or more series-connected transistors, and it further includes a balancing network. The balancing network includes a resistor network configured to divide a voltage from a voltage source across the series-connected transistors. The resistor network includes at least two resistive legs connected in parallel. In each resistive leg, two or more resistors are connected in series. The balancing network may further comprise at least one capacitive leg of series-connected capacitors connected across the series-connected transistors, and it may further comprise at least one leg of series-connected avalanche diodes connected across the series-connected transistors for overvoltage protection. In example embodiments, the series-connected transistors are JFETs. In other example embodiments, the series-connected transistors may be HEMTs or GaN transistors.

Gill, Lee↗

Lightning protection of wind turbines

Possible damages to wind turbine components due to lightning strikes are discussed and means to prevent the damage are presented. A low resistance path to the ground is noted to be essential for any turbine system, including metal paths on nonmetal blades to conduct the strike. Surge arrestors are necessary to protect against overvoltages both from utility lines in normal operation and against lightning damage to control equipment and contactors in the generator. MOS structures are susceptible to static discharge injury, as are other semiconductor devices, and must be protected by the presence of static protection circuitry. It is recommended that the electronics be analyzed for the circuit transient response to a lightning waveform, to induced and dc current injection, that input/output leads be shielded, everything be grounded, and lightning-resistant components be chosen early in the design phase.

Dodd, C. W.↗

Extending the Life of NASA’s Tracking and Data Relay Satellite (TDRS)-8: TDRS-8 Power Challenges And Planning for End of Mission

The United States National Aeronautics and Space Administration (NASA) Near Space Network’s Space Relay (SR) System provides communication relay services to a number of scientific and manned space missions with its Tracking and Data Relay Satellite (TDRS) constellation. NASA’s eighth Tracking and Data Relay Satellite (TDRS) has been experiencing a decline in the health of its power subsystem, and recent reliability analyses indicate that the end of its mission serving the Space Relay is imminent. Launched in 2000, TDRS-8 is the oldest TDRS built upon a Boeing 601 platform, and as such it is the first TDRS to experience these age-related failures. The most prevalent elements of the power subsystem to decline are the solar array circuitry and the Bus Voltage Limiters (BVLs), which prevent too much power from the solar arrays being transferred to the bus by shunting excess current. This means that while the loss of solar array circuits introduces concerns that the solar arrays will continue providing the spacecraft with enough current to remain power positive, the loss of BVLs introduces a concern that the bus may not be adequately protected from overvoltage events. Spacecraft engineers at the TDRS primary ground terminal, the White Sands Complex (WSC) in Las Cruces, New Mexico, and at NASA's Goddard Space Flight Center (GSFC) have also been working in collaboration with Boeing to develop innovative techniques to extend the serviceable life of TDRS-8.

tdrs↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-power ac/dc variable load simulator

Design of medium-power dynamic electrical load simulator has been extended to permit simulation of ac as well as dc loads and to provide for operation at higher power levels. Simulator is internally protected against reverse voltage, overvoltage, overcurrent, and overload conditions.

Joncas, K. P.↗

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Transient Voltage Surge Suppressors

Determining the effectiveness of surge and pulse protection devices in the United States power grid against effects of a High-Altitude Electromagnetic Pulse (HEMP) is crucial in determining the present state of grid resilience. Transient Voltage Surge Suppressors (TVSS) are used to protect loads in substations from transient overvoltages. Designed to mitigate the effects of lightning, their response to a HEMP event is unknown and was determined. TVSSs were tested in two unique configurations using a pulser that generates pulses in the tens of nanoseconds scale to determine their protective capability as well as to determine their self-resilience against HEMP pulses. Testing concluded that TVSS devices adequately protect against microsecond scale pulses like lightning but do not protect against pulses resembling HEMP events. It suggests that TVSS devices should not be relied upon to mitigate the effects of HEMP pulses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

Enhancing grid reliability and resilience through novel DER control, total situational awareness and integrated distribution-transmission representation

High penetration of distributed energy resources (DERs) can lead to overvoltage and thermal violations, miscoordination of protection devices and potential adverse control interactions. The challenges are exacerbated by a lack of operator situational awareness of behind-the-meter DERs, and T&D interactions. Furthermore, the large attack surface of a DER environment creates significant cyber security challenges. The motivation is to address these barriers. The main goal is to enable extreme levels of DERs in distribution systems while simultaneously enhancing their reliability and resiliency. This is achieved by a data-driven approach for operation, planning and control of distribution systems with total situational awareness and real-time DER control enabled by a network of edge intelligent devices, a cloud-based analytical platform, and secure communications.

14 SOLAR ENERGY↗

Pulse-width-modulated high-current power supply

Power supply achieves efficiency rating of approximately 80 percent at rated maximum output current. Protection circuitry prevents logic/memory loads from losing stored data if supply protection circuit initiates power shut down; prevents damage caused by overtemperature condition; protects logic/memory load from undervoltage to overvoltage conditions. Warning signal indicates power shutdown.

Messano, E. A.↗

Surge protection with automatic reset

Circuit turns power off automatically when surge occurs and restores power when voltage returns to normal. Transmitters and other equipment are protected in electrically noisy environments; however, if three transient overvoltages (or continuous overvoltage) are sensed within 3.2 seconds, circuit turns power supply off permanently since serious failure may have occurred.

Chan, R. B.↗