A Flexible and Secure Evaluation Platform for Overvoltage Protection in Power Electronics Systems

This paper summarizes the fault mechanisms specifically for the overvoltage protection schemes in power electronic converters and the resulted power electronics enabled systems. A flexible and secure evaluation platform for overvoltage protection, has also been presented based on this conceptual mechanism. The proposed platform aims at testing the protection performance of distinctive overvoltage protection schemes. It would be applied to verify the effectiveness, identify potential strengths and weaknesses, and obtain the most critical protection response time to provide sufficient engineering insights for the designer. The operation principle and detailed design guideline have been presented first. The comprehensive component stress has been analyzed. An intensive set of LTSpice simulations have been conducted to show the validity of the proposed assessment approach.

Zheng, Sheng↗

A Fast-Response High-Accuracy Overvoltage Protection Circuit for Soft-Switching Current-Source Converters

Although voltage-source converters (VSCs) have been a focus of research for decades and are widely applied in numerous applications, they face great challenges in short-circuit failures, high dv/dt and electromagnetic interference (EMI), especially using wide bandgap devices. Instead, current-source converters (CSCs) are attracting increasing attention in recent years owing to their friendliness to short-circuit faults, improved EMI, etc. For CSCs, overvoltage is the most catastrophic failure since the semiconductor devices can hardly withstand an overvoltage for a short pulse. In this paper, a fast-response high-accuracy overvoltage protection (OVP) circuit is proposed to protect CSCs from overvoltage damage. It also features a small form factor, good noise-immunity, friendly retrofit capability, and no need for active switches. In this paper, the operating principle and design guideline of the proposed OVP circuit is introduced. Its effectiveness is validated in soft-switching solid-state transformer (S4T) at 500 V. In experiments, the voltage detection error of less than 5% and a propagation delay of fewer than 400 ns have been achieved.

30 DIRECT ENERGY CONVERSION↗

Alternative 3V0 Development for Ground Fault Overvoltage Protection with DERs/Renewables Interconnection (Final Report)

The ground fault overvoltage (GFOV) and the required traditional 3V0 installation has become a concerned issue for renewable/DER integration. Based on the alternative 3V0 methodology proposed by the PI and the feasibility study awarded by DOE SBIR/STIR project (Award No. DE-SC0018888), APS and RPI investigated development of a low-cost alternative 3V0 product based on the surge arrester current monitoring. The alternative 3V0 feasibility study completed by APS and RPI has verified that the alternative 3V0 is an effective solution (possibly the only one) under various circuit conditions and is competitive to traditional 3V0 methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High voltage switch with cascaded transistor topology

A switching apparatus includes three or more series-connected transistors, and it further includes a balancing network. The balancing network includes a resistor network configured to divide a voltage from a voltage source across the series-connected transistors. The resistor network includes at least two resistive legs connected in parallel. In each resistive leg, two or more resistors are connected in series. The balancing network may further comprise at least one capacitive leg of series-connected capacitors connected across the series-connected transistors, and it may further comprise at least one leg of series-connected avalanche diodes connected across the series-connected transistors for overvoltage protection. In example embodiments, the series-connected transistors are JFETs. In other example embodiments, the series-connected transistors may be HEMTs or GaN transistors.

Gill, Lee↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Transient Voltage Surge Suppressors

Determining the effectiveness of surge and pulse protection devices in the United States power grid against effects of a High-Altitude Electromagnetic Pulse (HEMP) is crucial in determining the present state of grid resilience. Transient Voltage Surge Suppressors (TVSS) are used to protect loads in substations from transient overvoltages. Designed to mitigate the effects of lightning, their response to a HEMP event is unknown and was determined. TVSSs were tested in two unique configurations using a pulser that generates pulses in the tens of nanoseconds scale to determine their protective capability as well as to determine their self-resilience against HEMP pulses. Testing concluded that TVSS devices adequately protect against microsecond scale pulses like lightning but do not protect against pulses resembling HEMP events. It suggests that TVSS devices should not be relied upon to mitigate the effects of HEMP pulses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

Enhancing grid reliability and resilience through novel DER control, total situational awareness and integrated distribution-transmission representation

High penetration of distributed energy resources (DERs) can lead to overvoltage and thermal violations, miscoordination of protection devices and potential adverse control interactions. The challenges are exacerbated by a lack of operator situational awareness of behind-the-meter DERs, and T&D interactions. Furthermore, the large attack surface of a DER environment creates significant cyber security challenges. The motivation is to address these barriers. The main goal is to enable extreme levels of DERs in distribution systems while simultaneously enhancing their reliability and resiliency. This is achieved by a data-driven approach for operation, planning and control of distribution systems with total situational awareness and real-time DER control enabled by a network of edge intelligent devices, a cloud-based analytical platform, and secure communications.

14 SOLAR ENERGY↗

Voltage Service Limits Smart Contract Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Generator

Modern electrical grids face growing stability risks from customer-owned generators, especially at points of common couplings (PCCs). Disruptive behavior from power-electronic sources can cause protective relays to isolate problematic generators, making measurement integrity critical. This article presents a distributed ledger technology (DLT) approach that uses smart contracts to evaluate PCC voltage measurements and trigger backup breaker operations. The approach is framed as a verifiable, multi-organization attestation and audit layer, not as a real-time control security mechanism. In the proposed architecture, voltage measurements from a hardware protective relay are anchored on a DLT through the Cyber Grid Guard (CGG) system for attestation by both the grid utility and customer-owned generator. A Voltage Service Limits (VSLs) smart contract evaluates the on-chain measurements against allowable phase-voltage limits derived from the ANSI C84.1 standard. The framework is validated in a hardware-relay-in-the-loop test bed under sustained-undervoltage, sustained-overvoltage, and transient line-to-line fault scenarios. The results show that the VSL smart contract can process these measurements and issue backup breaker actions consistent with the defined service-limit criteria, demonstrating the DLT potential as a verifiable audit layer at the PCC that complements primary protection.

cyber security↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Impact of the Lightning Surge on SiC-based Medium-voltage Three-phase Four-wire Grid-connected Converters

The surge voltage induced by lightning will generate an inrush current in a grid-connected converter. It may not be large in Si-based converters because of the large grid side inductive filter. However, for SiC-based multi-level converters, the inrush current could be very large due to the small filter inductance, which is selected based on the current harmonic consideration. Most previous work focuses on system-level lightning protection while the converter-level impact, especially the internal components of the converter, is rarely discussed. This paper presents the analysis of the impact of the lightning surge on a 10 kV SiC MOSFET-based 13.8 kV three-phase four-wire grid-connected converter. The IEEE arrester model and the combined wave generator model in IEC 61000-4-5 standard are used to evaluate the inrush current, DC-link overvoltage, and component-to-ground potential of the converter. Analysis and simulation results have been provided to demonstrate the impact of lightning on the grid-connected converter. It is found that large inrush current occurs due to the small filter inductance, and the neutral-to-ground impedance impacts both the inrush current and the neutral point-to-ground potential.

Li, Haiguo↗