Search NASA⌕ Search

SEARCH · Search NASA

Results for “Owner's Technical Specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Hypothesis of Hot Tank Failure

Work has begun on a Design Basis Document / Owner’s Technical Specification for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. A principal topic of recent interest is the failures of the hot salt tanks in central receiver projects. The paper outlines a hypothesis for the source of the failures, and discusses a range of possible solutions.

14 SOLAR ENERGY↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects [Slides]

Develop a Design Basis Document / Owner’s Technical Specification for nitrate salt systems in commercial parabolic trough and central receiver projects. A Design Basis Document is to a project what a heat exchanger specification is to a heat exchanger, Extensive commercial experience in salt equipment and system design, much of it gained through mistakes and associated expenses. Distill the successful experience with nitrate salt systems from as many commercial projects as possible. Starting from 7 historical Design Basis Documents, compile a consensus description of commercial equipment and system designs.

14 SOLAR ENERGY↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Volume 1 Specifications for Parabolic Trough Projects, Volume 2 - Specifications for Central Receiver Projects, Volume 3 - Narrative

Design Basis Documents / Owner’s Technical Specifications are developed for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. The goals were to 1) distill the successful experience with nitrate salt systems from as many commercial projects as possible, 2) provide technical bases for equipment design/selection that an owner can impose on an EPC contractor, 3) compile this information in one location to provide guidance on salt systems that is as broadly applicable to as many projects as possible, and 4) work toward an industry consensus on a Design Basis Document that reflects the lessons learned from earlier commercial projects. The document allows an owner to provide design guidance, and to impose a minimum set of requirements, above and beyond those in the normal Codes and Standards, on an EPC contractor in an effort to avoid a repeat of past mistakes. If successful, this would allow salt systems to achieve the same levels of reliability and availability as commercial parabolic trough plants using diphenyl oxide / biphenyl (i.e., Dowtherm A, Therminol VP-1) as the heat transfer fluid. The report consists of 3 volumes: • Volume 1 - Specifications for Parabolic Trough Projects • Volume 2 - Specifications for Central Receiver Projects • Volume 3 - Narrative Volumes 1 and 2 include discussions of the following topics: • Plant functional requirements for the salt systems • Plant operating states, and transitions between states, for the salt systems • Risk analysis of the principal salt components • Plant requirements for the salt systems to meet the functional and the operating requirements • Type of specification for the principal salt components: functional; or prescriptive • Current state of the art for salt systems. Volume 3 discusses a number of cases in which the salt equipment at commercial parabolic trough and central receiver projects has not met the projected levels of reliability and availability. Possible reasons for the sources of the problems are discussed, as is a range of possible alternate designs that could avoid the known problems.

14 SOLAR ENERGY↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY↗

Cybersecurity Incident Response Guide for Wind

As wind energy systems become increasingly digitized and interconnected, they face a growing array of cyber threats that can disrupt operations, compromise safety, and trigger cascading impacts across the energy ecosystem. The Wind Incident Response Guide provides a structured, wind-specific framework for preparing for, detecting, responding to, and recovering from cyber incidents. Drawing on lessons from field demonstrations, cyber-physical testbeds, and stakeholder engagement across the wind sector, this guide integrates technical, operational, and regulatory considerations to support asset owners, operators, and responders. It outlines key roles and responsibilities, maps incident response phases to wind-specific scenarios, and highlights applicable laws, regulations, standards, and best practices. By tailoring general cybersecurity principles to the unique architectures and operational constraints of wind systems—including remote access, legacy components, and environmental interfaces—this guide aims to enhance resilience, reduce response time, and support coordinated action across public and private stakeholders. It is intended as a practical resource for utilities, developers, regulators, and emergency managers working to secure the future of wind energy.

17 - WIND ENERGY↗

Household Energy Burden in Lawrence, Massachusetts [Slides]

The City of Lawrence consists of 18 census tracts, of those, 9 census tracts have an average energy burden (the percent of income spent on energy bills) of 6% or greater. The Lawrence Stakeholders Coalition's (LSC) main goal is to "Reduce energy burden and create well-paying local jobs and businesses by increasing the distribution and use of sustainable technologies such as heat pumps, community and rooftop solar, and weatherization." As part of that goal, the LSC is interested in understanding Lawrence's pathway to electrification, specifically through the building sector. This technical assistance aims to assist the LSC's electrification and energy burden reduction planning by: 1) Identifying the most energy-burdened households by owner-occupied and renter-occupied housing status; 2) Identifying and quantifying the characteristics of the most energy-burdened housing units by housing type, age, and heating fuel type; 3) Identifying the tenure and housing types of the most energy-burdened and prevalent households for subsequent ResStock analysis of cost-effective efficiency upgrades.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reducing Uncertainty of Fielded Photovoltaic Performance (Final Technical Report)

Improved analysis and reporting of photovoltaic (PV) field performance increases the certainty of owners and financiers that systems will perform as expected. Advanced module technologies (e.g., PERC, HJT, and bifacial) introduce new degradation mechanisms and performance characteristics. The FY19-21 Reducing Uncertainty project leveraged data from the ever-increasing PV fleet to develop models and understanding of the field performance of existing and new technologies. Specifically, we accomplished: report on field performance and degradation rates for high-efficiency silicon (HJT, PERC, IBC) and more conventional technologies; developed automated analysis techniques to quantify system performance (performance ratio, energy yield) and production shortfalls (soiling, degradation, availability); refined the RdTools software toolkit to bring standard, validated analysis techniques to bear on third-party data; analyzed and reported on large datasets including Treasury data and Lawrence Berkeley National Laboratory's Utility-Scale dataset to expand the high-quality degradation-rate histogram published previously; worked with industry partners and the DuraMAT data hub to enable private parties to share and aggregate PV production data anonymously, leveraging cloud-based data analysis infrastructure and publishing on US fleet-scale performance comprising over 7GW of operating systems. (https://www.nrel.gov/pv/fleet-performance-data-initiative.html). Through our industry collaborations we have engaged in NDA-covered data transfer with twelve PV fleet owners as of January 2022, with more agreements in negotiation. Our scalable cloud-based time series database contains over 30 billion rows (20TB) of PV time series data, representing over 1700 commercial and utility-scale systems, and over 7.2 GW of DC capacity (Fig 1). Initial field performance results have been distributed in several public reports. Because our fleet composition and data quality methods are continually improving, annual updates to these results are published to our PV Fleet webpage [ https://www.nrel.gov/pv/fleet-performance-data-initiative.html ] and DuraMAT data hub [DOI: 10.21948/1842958]. Another existing dissemination channel used for observed soiling losses is a map we maintain for soiling losses. Additional products developed include a report detailing fleet-wide performance index, availability, startup loss and snow loss factors, a detailed report on the 1603 grant dataset comprising over 100,000 PV systems with failure and performance details and a utility-scale report coauthored with LBNL on 31 GW of system performance.

14 SOLAR ENERGY↗

Comprehensive Assessment of On-And Off-Board Vehicle-To-Grid Technology Performance and Impacts on Battery and the Grid

This project defined, developed, and tested the open standards-based requirements, engineering design and system integration of on and off-vehicle Vehicle-to-Grid technologies both on the grid and on the PEV, to assess their effectiveness in implementing the use cases that create value for the grid, which in turn, can be passed on to the ratepayers and the PEV owners. The project comprised of three key categories of work and four key sub-areas of work. The three key categories were: On-Vehicle V2G, Off-Vehicle V2G, and impact of V2G operation on the battery capacity degradation. The four key sub-areas of work under each of these categories were: defining requirements, implementing the technology, performing system integration testing, and estimating the value of each of the grid services under specific assumptions, on a per-vehicle and on an aggregated basis. The technical implementation demonstrated the validity of standards-based approach to grid integration that led to interoperability, in addition to assessing the operational details with grid constraints imposed at the transformer level. The technology implementation also identified the subtle gaps in the standards definition to close the feedback loop on the accuracy of the standards as written, which are being implemented as revisions to the appropriate protocols. The battery impacts assessment developed a test cycle that the batteries from a real PHEV were subjected to for both the mobility-only and mobility with V2G specific energy cycling. While the battery impact results show a clear incremental degradation in response to additional throughput for V2G application purposes, the amount of additional kWh that can be made available without exceeding the end-of-life capacity definition of the battery at its 10-year warranty period was found to be significant. Given that the PEV battery being exercised during testing was a PHEV battery (smaller energy capacity), and 44% of its usable energy (i.e., SOC) was utilized daily for V2G applications, the EVs with much larger batteries will fare much better, either in terms of extracting more value in terms of incremental kWh for V2G, or in terms of relative incremental degradation of the capacity through the battery lifespan. Further, this battery was the second-generation Lithium-Ion chemistry circa 2015, which is at least two generations ago. Continual improvements in electrochemistry and manufacturing techniques as well as on-board capacity will enable the future batteries to provide even more energy for non-mobility-related services. Finally, the valuation of V2G energy services at the premise, distribution, and the ISO/market level was carried out for both the on-vehicle and off-vehicle cases, to understand both the GHG mitigation and operational efficiency improvements in quantitative terms. The analysis indicates that between $\$400$ and $\$1400$ per year of total value to the grid can be realized. When netted of costs to implement V2G either on or off-vehicle, the net value is available to be shared between the ratepayers and the EV owners. Over the life of the EV, therefore, this value becomes significant and can easily provide both ratepayer and EV owner benefits more than the cost of the equipment, either on or off-board, in addition to providing GHG mitigation benefits both on the grid and on the mobility sides. For these benefits to accrue, the key learnings from both the on- and off-vehicle V2G parts of the project indicate the need for at-scale demonstrations through involvement of real EV owners to validate both the technical feasibility, interoperability, as well as real grid benefits by performing extensive data collection and analysis. This will help inform the grid planners, the program designs, and tariff designers, as well as automotive and equipment manufacturers how best to create their products to maximize grid, ratepayer, and EV owner value.

30 DIRECT ENERGY CONVERSION↗

Exploring the Potential of Second-Life Batteries for Mobile Charging Infrastructure: A Review

This review paper investigates the potential applications of second-life batteries (SLBs) specifically for mobile charging stations. As the adoption of electric vehicles (EVs) continues to rise, the need for accessible and efficient charging infrastructure becomes increasingly critical to address range anxiety of EV owners. The repurposing of SLBs presents a promising solution to address this need, offering cost-effective and sustainable alternatives to traditional stationary charging infrastructure. This paper examines key technical considerations, including battery chemistry, state of health assessment, heterogeneity and battery management system design, and safety protocols tailored to SLBs. The paper also highlights economic and environmental implications of utilizing SLBs in mobile charging applications, encompassing techno-economic analysis techniques and sustainability metrics. Through an exploration of challenges, opportunities, and emerging trends, this review aims to provide valuable insights to stakeholders involved in the development and deployment of SLBs in mobile charging infrastructure.

Gautam, Mukesh (ORCID:0000000305715825)↗

Value of Information and Data Management Platform Promoting Modern Data Analysis Utilization. STTR Phase I, Final Technical Report

The immense growth in weather and river sensor data availability along with increases in computational power and algorithmic sophistication have enabled the widespread application of physical, machine learning, and artificial intelligence algorithms to river forecasting. The forecasts produced by widely varying model approaches are inherently limited in different ways, such as by the number and quality of training observations, producing biased predictions that achieve optimal skill only over specific ranges of weather and river conditions. Thus, despite the growing availability and new sources of forecasts, hydropower owners cannot fully leverage the information because they lack an effective mechanism to determine the “best” forecast for given conditions or objectives. Tools are needed to consolidate forecast information, demonstrate skill, and extract optimal forecast guidance from the range of possibilities. Such tools will increase uptake and beneficial use of the growing wealth of forecast information, and lead to improved operating decisions, optimal power generation, and enhanced system value. This research proposes to improve the value of forecasts by developing a broadly accessible verification framework and applying machine learning techniques to identify the ‘best’ forecast from an ensemble of sources given the current weather, river, and operating conditions.

13 HYDRO ENERGY↗

Building Envelope Campaign – Program Design and Stakeholder Engagement

Building envelope technologies impact approximately 30% of the primary energy consumed by residential and commercial buildings. The Building Envelope Campaign (BEC), which is part of the Department of Energy’s Better Buildings Program, is a market transformation effort to help building owners and managers invest in high performance building envelope technologies for both new and existing commercial buildings. The success of the Campaign has depended on constructing a compelling program design plus organizing a technical team with ability to effectively recruit Participants and Supporters from across industry and keep them engaged.The design of the campaign included developing a strategy to leverage other technology campaigns within the Better Buildings program, identifying stakeholders (including diverse member groups that may have been underserved by previous technology campaigns), recruiting Supporters and Participants, and providing technical assistance in the form of a campaign-specific Building Envelope Performance tool and metric to help benchmark various building envelope options.Engagement had to overcome three main challenges – securing the Campaign Supporters/Participants, helping participants to use the envelope tool to evaluate project options, and getting those participants to submit successful envelope projects for evaluation and recognition by the program. The concepts are simple but program design/implementation and, in particular, sustaining stakeholder engagement can be challenging. This paper will highlight the approaches taken in: program design, engaging industry members, identifying and reaching underserved stakeholders, demonstrating benefits of high performance building envelope technologies and making the case for engaging in this campaign.

McLeod, Hayley↗

Cybersecurity Platform and Certification Framework Development for Extreme Fast Charging (XFC)-Integrated Charging Ecosystem (Final Project Report)

This report summarizes a pioneering effort in Electric Vehicle charging infrastructure ecosystem cybersecurity requirements, assessment methodologies, functional verification, as well as embodiment of the key technologies in the form of hardware and software tools being made available to the public. EPRI led a team of experts, as well as a stakeholder coalition encompassing all key actors in the EV charging infrastructure ecosystem that includes eXtreme Fast Charging (XFC) equipment (defined as 200kW or above). EV charging infrastructure in the United States is a patchwork of networks that have continued to grow organically and have been designed to serve the charging needs of the EV owners, who are their customers. In doing so, each network provider, as well as their connected entities such as the cloud Electric Vehicle Service Providers or EVSPs, utility back office, utility AMI networks, payment networks, as well as Original Equipment Manufacturer (EV manufacturer) telematics networks, have designed systems that may work well individually, but no single entity is responsible for the entire ecosystem to be secure in terms of data exchange. Furthermore, there is no uniformity in how each actor has implemented the cybersecurity requirements since no system-wide cybersecurity requirements existed prior to this project. The final project report describes the technical approach guided by the EV charging infrastructure cybersecurity working group, convened specifically for this project. The technical approach included definition of requirements at the ecosystem level, treated as a ‘system of systems’, and then passed down to individual systems (EVSE, EV, cloud EVSP, utility, and the payment networks), followed by developing the cybersecurity risk and vulnerability assessment methods, that were later applied to real-world cyber-physical systems at EPRI, ANL, and NREL laboratories, to validate both the process and the results. Finally, in a spotlight over the most vulnerable equipment, which is the EV charge station (AC or DC), the team developed a multi-layer cybersecurity implementation in the embedded domain embodied by the open-source Secure Network Interface Card (SNIC) demonstrating the various ways in which the infrastructure can be secured protecting against the identified attack surfaces. Finally, the entire process of EV infrastructure cybersecurity assessment was encapsulated in the Electric Vehicle Charging Cybersecurity Management (EVC2M) online GUI-based tool, that is expected to be released to the public. The report presents the objectives, the technical approach, the key results, and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Santa Barbara Desalination Digital Twin Technical Report

A digital twin is a computer model that has sufficient breadth and fidelity to enable diagnostic and predictive analyses for outputs of interest. We have constructed a digital twin of the SB desal plant using the ProteusLib software developed for NAWI under task 4.2.2, and specifically the ProteusLib models of pumps, filters, mixers, splitters, and reverse osmosis units and a seawater property model. The steps needed to configure this digital twin with the real conditions of the SB desal plant are: (1) Data reconciliation, which is gathering the data and plant connectivity and ensure that all relevant values are present and in the correct units and validating the data using material and energy balances, and correct for errors, gaps, or deviations; (2) Parameter estimation, which is matching model parameters with data from previous step, filling missing parameters with initial estimates, then iteratively refining estimated values. Once we completed the digital twin, we used the optimization capabilities of ProteusLib to compute outputs of interest over a chosen range of inputs. The primary output of interest to the owners of the plant is its specific energy consumption (kWh/acre-foot). The remainder of this report will provide more detail on the data reconciliation, parameter estimation, and analyses we performed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Data Processing Pipeline To Extract A Knowledge Graph From Heterogeneous Data For Socio-technical Analysis Of Critical Infrastructure Influence

The code is written in Python and consists of the following pipeline that is implemented in Apache Airflow. This pipeline intends to understand the companies that are directly or indirectly involved with a type of critical infrastructure system at some point in that system's lifecycle. The pipeline takes a configuration file that specifies a list of initial companies to consider, a geographic region of interest, and a set of SEC form types as well as other data sources (e.g. CrunchBase) from which to extract entities and relations. There are four main components to this pipeline as currently implemented: Entity Extraction, Network Construction, Analysis, and Visualization. First, Entity Extraction, is implemented as the `topear-extract_organizations` Apache Airflow workflow. Given an initial query that specifies a geographic region of interest and a time interval, the software will extract CI facilities of interest and organizations that have a direct influence relationship to those facilities (e.g. ownership). During the course of the LDRD, we focused on Electric Vehicle charging stations and this information is available via the Department of Energy (DOE) database on fueling stations maintained by NREL. Within the context of the DOE CESER project, we have focused on Battery Energy Storage Systems (BESS). Second, the Network Extraction component will iteratively construct a social network graph given the set of organizations and people extracted in the previous step. Organizations (and eventually People if desired) are then fed as a query to the `topgear-construct_social_network` Apache Airflow workflow which given a set of initial companies and data sets (e.g. SEC EDGAR form types, OpenCorporates, Crunchbase). This Airflow workflow will iteratively query such data sources to discover relationships with new organizations and people. For example, this module can iteratively query SEC EDGAR for metadata that documents the number of each type of form for the given set of companies and their location. This forms metadata represents a catalog of data sources from SEC EDGAR for the extracted social network knowledge graph. The pipeline then downloads these forms from the website and saves them in a build directory for further processing. These documents are then parsed for entities and relations. Again, we note that in additional to SEC data sources, this step can also pull in information on organizations via API services such as CrunchBase and OpenCorporates or bulk data sources. At the end of this step, the resultant social network, the Critical Infrastructure network, and the edges that encode relationships between organizations and CI facilities, form the Adversarial Socio-Technical Network (ASTN) that informs the analysis. Third, the Analysis component processes these generated ASTN. Previously, that has included the ability to compare prevalence of different vendors for a given infrastructure component type across different regions as well as identify common public and private investors across those vendors. This was demonstrated for EV Charging Stations across several different metropolitan areas within an IEEE PES GridEdge publication. More recently, we have looked at ways to identify infrastructure owners and operators of BESS with the most nameplate capacity across different states as well as other indictors of risk resulting from changes in ownership over time. Finally, the Visualization component consists of an HTML/CSS/JS framework by which users can interact geospatial, operational, and organizational relationships across a given portfolio of Critical Infrastructure facilities. The objective is to provide a library of UI/UX modules that can be repurposed for stakeholder-specific dashboards. All of the modules are related via a common event model that enables UI actions in one view to percolate across the other views.

Weaver, Gabriel [Idaho National Laboratory (INL), ↗

CyOTE ASSET OWNER ENGAGEMENT – SIDE CHANNEL POWER ANALYSIS PROTOTYPE

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through the Cybersecurity for the Operational Technology Environment (CyOTE) Program, worked with energy sector asset owners and operators (AOOs), partners, and Idaho National Laboratory (INL) to develop capabilities for AOOs to independently identify adversarial tactics, techniques, and procedures (TTPs) within their operational technology (OT) environments. The CyOTE methodology seeks to identify adversarial techniques within an AOO OT environment that could result in physical disruptions to energy flow or damage to equipment. CyOTE provides a general roadmap for AOOs, starting from a triggering event, or the point in time and space they perceive an anomalous event or condition meriting investigation, and culminating when the AOO has sufficient confidence to make a business risk decision on the appropriate resolution. This paper outlines the results of one such engagement with the New York Power Authority (NYPA), where the CyOTE program partnered with an AOO to develop a design specification for a power side channel detector to identify anomalous changes to device load. It describes the goal of developing this capability, the development process, the challenges the technical teams faced and the future steps an AOO will need to take to install and use this detector in its OT environment.

99 GENERAL AND MISCELLANEOUS↗

Use of Operating Agreements and Energy Storage to Reduce Photovoltaic Interconnection Costs: Technical and Economic Analysis

This report presents an analytical methodology to identify alternative options to manage interconnection costs and streamline interconnection timelines for distribution system-connected photovoltaic (PV) systems not co-located with load. Specifically, the report details the methodology and results of an analysis that: 1. Identifies potential grid violations that would be induced by a PV system requesting interconnection to a distribution circuit; 2. Identifies multiple technically viable options for mitigating the potential violations, including infrastructure upgrades, downsizing the PV system size, curtailment of PV, and addition of battery energy storage; 3. Defines the required technical operating parameters of the system in order to mitigate all potential violations (the "Operating Envelope"); 4. Compares the economics of each option, from the PV developer's perspective. The analysis supports the ongoing evolution of interconnection standards for combined PV and energy storage systems by providing a methodology to define allowable maximum export limits during each hour. The methodology presented could be used by utilities as part of the interconnection study process, to inform negotiations with DER developers and the drafting of mutually acceptable interconnection agreements. The resulting technical operating parameters could be included as part of the interconnection service agreement (ISA) between the system owner and the utility company. The companion report to this analysis, Gill et al. (2022), details the envisioned framework for the implementation of the technical operating parameters.

14 SOLAR ENERGY↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗