Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ozone Monitoring Instrument (OMI)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measuring Aerosol Optical Properties with the Ozone Monitoring Instrument (OMI)

The Ozone Monitoring Instrument (OMI) is the Dutch-Finnish contribution to the NASA EOS-Aura mission scheduled for launch in January 2004. OM1 is an imaging spectrometer that will measure the back-scattered Solar radiance between 270 an 500 nm. With its relatively high spatial resolution (13x24 sq km at nadir) and daily global coverage. OM1 will make a major contribution to our understanding of atmospheric chemistry and to climate research. OM1 will provide data continuity with the TOMS instruments. One of the pleasant surprises of the TOMS data record was its information on aerosol properties. First, only the absorbing aerosol index, which is sensitive to elevated lay- ers of aerosols such as desert dust and smoke aerosols, was derived. Recently these methods were further improved to yield aerosol optical thickness and single scattering albedo over land and ocean for 19 years of TOMS data (1979-1992,1997-2002), making it one of the longest and most valuable time series for aerosols presently available. Such long time series are essential to quantify the effect of aerosols on the Earth& climate. The OM1 instrument is better suited to measure aerosols than the TOMS instruments because of the smaller footprint, and better spectral coverage. The better capabilities of OMI will enable us to provide an improved aerosol product, but the knowledge will also be used for further analysis of the aerosol record from TOMS. The OM1 aerosol product that is currently being developed for OM1 combines the TOMS experience and the multi-spectral techniques that are used in the visible and near infrared. The challenge for this new product is to provide aerosol optical thickness and single scattering albedo from the near ultraviolet to the visible (330-500 nm) over land and ocean. In this presentation the methods for deriving the OM1 aerosol product will be presented. Part of these methods developed for OM1 can already be applied to TOMS data and results of such analysis will be shown.

Veefkind, J. P.↗

Testing the Archivas Cluster (Arc) for Ozone Monitoring Instrument (OMI) Scientific Data Storage

The Ozone Monitoring Instrument (OMI) launched on NASA's Aura Spacecraft, the third of the major platforms of the EOS program on July 15,2004. In addition to the long term archive and distribution of the data from OM1 through the Goddard Earth Science Distributed Active Archive Center (GESDAAC), we are evaluating other archive mechanisms that can archive the data in a more immediately available method where it can be used for futher data production and analysis. In 2004, Archivas, Inc. was selected by NASA s Small Business Innovative Research (SBIR) program for the development of their Archivas Cluster (ArC) product. Arc is an online disk based system utilizing self-management and automation on a Linux cluster. Its goal is to produce a low cost solution coupled with the ease of management. The OM1 project is an application partner of the SBIR program, and has deployed a small cluster (5TB) based on the beta Archwas software. We performed extensive testing of the unit using production OM1 data since launch. In 2005, Archivas, Inc. was funded in SBIR Phase II for further development, which will include testing scalability with the deployment of a larger (35TB) cluster at Goddard. We plan to include Arc in the OM1 Team Leader Computing Facility (TLCF) hosting OM1 data for direct access and analysis by the OMI Science Team. This presentation will include a brief technical description of the Archivas Cluster, a summary of the SBIR Phase I beta testing results, and an overview of the OMI ground data processing architecture including its interaction with the Phase II Archivas Cluster and hosting of OMI data for the scientists.

Tilmes, Curt↗

New-Generation NASA Aura Ozone Monitoring Instrument (OMI) Volcanic SO2 Dataset: Algorithm Description, Initial Results, and Continuation with the Suomi-NPP Ozone Mapping and Profiler Suite (OMPS)

Since the fall of 2004, the Ozone Monitoring Instrument (OMI) has been providing global monitoring of volcanic SO2 emissions, helping to understand their climate impacts and to mitigate aviation hazards. Here we introduce a new-generation OMI volcanic SO2 dataset based on a principal component analysis (PCA) retrieval technique. To reduce retrieval noise and artifacts as seen in the current operational linear fit (LF) algorithm, the new algorithm, OMSO2VOLCANO, uses characteristic features extracted directly from OMI radiances in the spectral fitting, thereby helping to minimize interferences from various geophysical processes (e.g., O3 absorption) and measurement details (e.g., wavelength shift). To solve the problem of low bias for large SO2 total columns in the LF product, the OMSO2VOLCANO algorithm employs a table lookup approach to estimate SO2 Jacobians (i.e., the instrument sensitivity to a perturbation in the SO2 column amount) and iteratively adjusts the spectral fitting window to exclude shorter wavelengths where the SO2 absorption signals are saturated. To first order, the effects of clouds and aerosols are accounted for using a simple Lambertian equivalent reflectivity approach. As with the LF algorithm, OMSO2VOLCANO provides total column retrievals based on a set of predefined SO2 profiles from the lower troposphere to the lower stratosphere, including a new profile peaked at 13 km for plumes in the upper troposphere. Examples given in this study indicate that the new dataset shows significant improvement over the LF product, with at least 50% reduction in retrieval noise over the remote Pacific. For large eruptions such as Kasatochi in 2008 (approximately 1700 kt total SO2/ and Sierra Negra in 2005 (greater than 1100DU maximum SO2), OMSO2VOLCANO generally agrees well with other algorithms that also utilize the full spectral content of satellite measurements, while the LF algorithm tends to underestimate SO2. We also demonstrate that, despite the coarser spatial and spectral resolution of the Suomi National Polar-orbiting Partnership (Suomi-NPP) Ozone Mapping and Profiler Suite (OMPS) instrument, application of the new PCA algorithm to OMPS data produces highly consistent retrievals between OMI and OMPS. The new PCA algorithm is therefore capable of continuing the volcanic SO2 data record well into the future using current and future hyperspectral UV satellite instruments.

OMI↗

Ozone Monitoring Instrument (OMI) collection 4: establishing a 17-year-long series of detrended level-1b data

The Ozone Monitoring Instrument (OMI) was launched on 15 July 2004, with an expected mission lifetime of 5 years. After more than 17 years in orbit the instrument is still functioning satisfactorily and in principle can continue doing so until the expected decommissioning of its platform Aura in 2025. In order to continue the datasets acquired by OMI and the Microwave Limb Sounder, the mission was extended up to at least 2023. Actions have been taken to ensure the proper functioning of the OMI operations, the data processing, and the calibration monitoring system until the eventual end of the mission. For the data processing a new level-0 (L0) to level-1b (L1b) data processor was built based on the recent developments for the TROPOspheric Monitoring Instrument (TROPOMI). With corrections for the degradation of the instrument now included, it is feasible to generate a new data collection to supersede the current collection-3 data products and reprocess the data of the entire mission up to now. This paper describes the differences between the collection-3 and collection-4 data. It will be shown that the collection-4 L1b data comprise a clear improvement with respect to the previous collections. By correcting for the gentle optical and electronic aging that has occurred over the past 17 years, OMI’s ability to make trend-quality ozone measurements has further improved.

UV↗

The Observed Response of Ozone Monitoring Instrument (OMI) NO2 Columns to NOx Emission Controls on Power Plants in the United States: 2005-2011

We show that Aura Ozone Monitoring Instrument (OMI) nitrogen dioxide (NO2) tropospheric column data may be used to assess changes of the emissions of nitrogen oxides (NOx) from power plants in the United States, though careful interpretation of the data is necessary. There is a clear response for OMI NO2 data to NOx emission reductions from power plants associated with the implementation of mandated emission control devices (ECDs) over the OMI record (2005e2011). This response is scalar for all intents and purposes, whether the reduction is rapid or incremental over several years. However, it is variable among the power plants, even for those with the greatest absolute decrease in emissions. We document the primary causes of this variability, presenting case examples for specific power plants.

remote sensing↗

Polar Mesospheric Clouds (PMCs) Observed by the Ozone Monitoring Instrument (OMI) on Aura

Backscattered ultraviolet (BUV) instruments designed for measuring stratospheric ozone profiles have proven to be robust tools for observing polar mesospheric clouds (PMCs). These measurements are available for more than 30 years, and have been used to demonstrate the existence of long-term variations in PMC occurrence frequency and brightness. The Ozone Monitoring Instrument (OMI) on the EOS Aura satellite provides new and improved capabilities for PMC characterization. OMI uses smaller pixels than previous BUV instruments, which increases its ability to identify PMCs and discern more spatial structure, and its wide cross-track viewing swath provides full polar coverage up to 90 latitude every day in both hemispheres. This cross-track coverage allows the evolution of PMC regions to be followed over several consecutive orbits. Localized PMC variations determined from OMI measurements are consistent with coincident SBUV/2 measurements. Nine seasons of PMC observations from OMI are now available, and clearly demonstrate the advantages of these measurements for PMC analysis.

DeLand, Matthew T.↗

Global Free Tropospheric NO2 Abundances Derived Using a Cloud Slicing Technique Applied to Satellite Observations from the Aura Ozone Monitoring Instrument (OMI)

We derive free-tropospheric NO2 volume mixing ratios (VMRs) and stratospheric column amounts of NO2 by applying a cloud slicing technique to data from the Ozone Monitoring Instrument (OMI) on the Aura satellite. In the cloud-slicing approach, the slope of the above-cloud NO2 column versus the cloud scene pressure is proportional to the NO2 VMR. In this work, we use a sample of nearby OMI pixel data from a single orbit for the linear fit. The OMI data include cloud scene pressures from the rotational-Raman algorithm and above-cloud NO2 vertical column density (VCD) (defined as the NO2 column from the cloud scene pressure to the top-of-the-atmosphere) from a differential optical absorption spectroscopy (DOAS) algorithm. Estimates of stratospheric column NO2 are obtained by extrapolating the linear fits to the tropopause. We compare OMI-derived NO2 VMRs with in situ aircraft profiles measured during the NASA Intercontinental Chemical Transport Experiment Phase B (INTEX-B) campaign in 2006. The agreement is generally within the estimated uncertainties when appropriate data screening is applied. We then derive a global seasonal climatology of free-tropospheric NO2 VMR in cloudy conditions. Enhanced NO2 in the free troposphere commonly appears near polluted urban locations where NO2 produced in the boundary layer may be transported vertically out of the boundary layer and then horizontally away from the source. Signatures of lightning NO2 are also shown throughout low and middle latitude regions in summer months. A profile analysis of our cloud slicing data indicates signatures of uplifted and transported anthropogenic NO2 in the middle troposphere as well as lightning-generated NO2 in the upper troposphere. Comparison of the climatology with simulations from the Global Modeling Initiative (GMI) for cloudy conditions (cloud optical thicknesses > 10) shows similarities in the spatial patterns of continental pollution outflow. However, there are also some differences in the seasonal variation of free-tropospheric NO2 VMRs near highly populated regions and in areas affected by lightning-generated NOx. Stratospheric column NO2 obtained from cloud slicing agrees well with other independently-generated estimates, providing further confidence in the free-tropospheric results.

NO2↗

Investigation of NO2 Measurements Made During DISCOVER-AQ and KORUS-AQ Campaigns in Conjunction with NO2 Tropospheric Column from the Ozone Monitoring Instrument (OMI) and High-Resolution Community Multi-Scale Air Quality (CMAQ) Model Simulation

Atmospheric NO2 is produced by combustion, lightning, and in soil. NO2 affects ozone production and criteria pollutant itself.It also has indirect radiative impacts in the troposphere, since ozone has largest warming effect in upper troposphere. Tropospheric vertical column densities (VCD) of NO2 are available from satellites (GOME, OMI, SCIAMACHY, GOME-2). DISCOVER-AQ and KORUS-AQ aircraft campaigns we reconducted to improve the use of satellites to monitor air quality for public health and environmental benefit in United States and South Korea. In this study, we investigate 1) How do these measurements compare? 2) What is the best way to make comparisons of space- and ground-based measurements?

multi-scale air quality↗

EOS-Aura's Ozone Monitoring Instrument (OMI): Validation Requirements

OMI is an advanced hyperspectral instrument that measures backscattered radiation in the UV and visible. It will be flown as part of the EOS Aura mission and provide data on atmospheric chemistry that is highly synergistic with other Aura instruments HIRDLS, MLS, and TES. OMI is designed to measure total ozone, aerosols, cloud information, and UV irradiances, continuing the TOMS series of global mapped products but with higher spatial resolution. In addition its hyperspectral capability enables measurements of trace gases such as SO2, NO2, HCHO, BrO, and OClO. A plan for validation of the various OM1 products is now being formulated. Validation of the total column and UVB products will rely heavily on existing networks of instruments, like NDSC. NASA and its European partners are planning aircraft missions for the validation of Aura instruments. New instruments and techniques (DOAS systems for example) will need to be developed, both ground and aircraft based. Lidar systems are needed for validation of the vertical distributions of ozone, aerosols, NO2 and possibly SO2. The validation emphasis will be on the retrieval of these products under polluted conditions. This is challenging because they often depend on the tropospheric profiles of the product in question, and because of large spatial variations in the troposphere. Most existing ground stations are located in, and equipped for, pristine environments. This is also true for almost all NDSC stations. OMI validation will need ground based sites in polluted environments and specially developed instruments, complementing the existing instrumentation.

Brinksma, E. J.↗

Science Objectives of EOS-Aura's Ozone Monitoring Instrument (OMI)

OMI is a UV/VIS nadir solar backscatter spectrograph, which provides near global coverage in one day with a spatial resolution of 13 x 24 sq km. OMI is a new instrument, with a heritage from the European satellite instruments GOME, GOMOS and SCIAMACHY. OMI's unique capabilities for measuring important trace gases with a small footprint and daily global coverage, in conjunction with the other Aura instruments, will make a major contribution to our understanding of stratospheric and tropospheric chemistry and climate change. OMI will measure solar irradiance and Earth radiances in the wavelength range of 270 to 500 nm with spectral resolution of about 0.5 nm and a spectral sampling of about 2-3 per FWHM. From these observations, total columns of O3, NO2, BrO and SO2 will be derived from the back-scattered solar radiance using differential absorption spectroscopy (DOAS). The TOMS total ozone record will also be continued by employing the well established TOMS algorithm. Because of the high accuracy and spatial resolution of the measurements, a good estimate of tropospheric amounts of ozone and NO2 are expected. Ozone profiles will be derived using the optimal estimation method. The spectral aerosol optical depth will be determined from measurements between 340 and 500 nm. This will provide information on aerosol concentration, aerosol size distribution and aerosol type. This wavelength range makes it possible to retrieve aerosol information over both land and sea. OMI observations will also allow retrievals of cloud coverage and cloud heights. From these products, the UV-B flux at the surface can then be derived with high spatial resolution.

Levelt, P. F.↗

Enhancing Long-Term Trend Simulation of OH Through the Synergy of Model Simulations and Aura Ozone Monitoring Instrument (OMI) NO 2 and HCHO Retrievals

During the last few years, tremendous progress has been made to develop an efficient parameterization module using agile machine learning techniques. The aim of this module is to provide dynamic response of the tropospheric hydroxyl radical (OH) to its major drivers, including trace gases, aerosols, clouds, and meteorology. This module, named ECCOH (pronounced “echo”) and implemented in NASA’s GEOS-5 global model, offers an unrealized opportunity to unravel the convoluted response of OH to its underlying drivers while approaching the accuracy of full-chemistry without incurring excessive computational costs, making it suitable for climate models. However, the accurate representation of OH in ECCOH poses challenges due to the lack of representation of some of its critical inputs such as the abundance of NO 2 and HCHO concentrations. As such, we leverage the well-characterized satellite observations of NO2 and HCHO columns from Aura OMI to enhance their representation in ECCOH using an optimal interpolation method for the time period of 2005 - present. We show how the inclusion of OMI information can affect the spatiotemporal variability and long-term trends of OH, CO, and CH 4 across the globe. Additionally, we underscore the necessity of obtaining high-fidelity information regarding tropospheric ozone from the southern hemisphere from space, a region currently lacking full verification in models, posing a challenge to get a reasonable amount of chemical sink for CH 4 .

OH↗

Simulations of Tropospheric NO2 by the Global Modeling Initiative (GMI) Model Utilizing Assimilated and Forecast Meteorological Fields: Comparison to Ozone Monitoring Instrument (OMI) Measurements

We present simulations of the tropospheric composition for the years 2004 and 2005, carried out by the GMI Combined Stratosphere-Troposphere (Combo) model, at a resolution of 2degx2.5deg. The model includes a new parameterization of lightning sources of NO(x) which is coupled to the cloud mass fluxes in the adopted meteorological fields. These simulations use two different sets of input meteorological fields: a)late-look assimilated fields from the Global Modeling and Assimilation Office (GMAO), GEOS-4 system and b) 12-hour forecast fields initialized with the assimilated data. Comparison of the forecast to the assimilated fields indicates that the forecast fields exhibit less vigorous convection, and yield tropical precipitation fields in better agreement with observations. Since these simulations include a complete representation of the stratosphere, they provide realistic stratosphere-tropospheric fluxes of O3 and NO(y). Furthermore, the stratospheric contribution to total columns of different troposheric species can be subtracted in a consistent fashion, and the lightning production of NO(y) will depend on the adopted meteorological field. We concentrate here on the simulated tropospheric columns of NO2, and compare them to observations by the OM1 instrument for the years 2004 and 2005. The comparison is used to address these questions: a) is there a significant difference in the agreement/disagreement between simulations for these two different meteorological fields, and if so, what causes these differences?; b) how do the simulations compare to OMI observations, and does this comparison indicate an improvement in simulations with the forecast fields? c) what are the implications of these simulations for our understanding of the NO2 emissions over continental polluted regions?

Rodriquez, J. M.↗

Version 2 of the global catalogue of large anthropogenic and volcanic SO 2 sources and emissions derived from satellite measurements

Sulfur dioxide (SO 2 ) measurements from the Ozone Monitoring Instrument (OMI), Ozone Mapping and Profiler Suite (OMPS), and TROPOspheric Monitoring Instrument (TROPOMI) satellite spectrometers were used to update and extend the previously developed global catalogue of large SO 2 emission sources. This version 2 of the global catalogue covers the period of 2005–2021 and includes a total of 759 continuously emitting point sources releasing from about 10 kt yr −1 to more than 4000 kt yr −1 of SO 2 , that have been identified and grouped by country and primary source origin: volcanoes (106 sources); power plants (477); smelters (74); and sources related to the oil and gas industry (102). There are several major improvements compared to the original catalogue: it combines emissions estimates from three satellite instruments instead of just OMI, uses a new version 2 of the OMI and OMPS SO 2 dataset, and updated consistent site-specific air mass factors (AMFs) are used to calculate SO 2 vertical column densities (VCDs). The newest TROPOMI SO 2 data processed with the Covariance-Based Retrieval Algorithm (COBRA), used in the catalogue, can detect sources with emissions as low as 8 kt yr −1 (in 2018–2021) compared to the 30 kt yr −1 limit for OMI. In general, there is an overall agreement within ±12 % in total emissions estimated from the three satellite instruments for large regions. For individual emission sources, the spread is larger: the annual emissions estimated from OMI and TROPOMI agree within ±13 % in 50 % of cases and within ±28 % in 90 % of cases. The version 2 catalogue emissions were calculated as a weighted average of emission estimates from the three satellite instruments using an inverse-variance weighting method. OMI, OMPS, and TROPOMI data contribute 7 %, 5 %, and 88 % to the average, respectively, for small (<30 kt yr −1 ) sources and 33 %, 20 %, and 47 %, respectively, for large (>300 kt yr −1 ) sources. The catalogue data show an approximate 50 % decline in global SO 2 emissions between 2005 and 2021, although emissions were relatively stable during the last 3 years. The version 2 of the global catalogue has been posted at the NASA global SO 2 monitoring website (https://doi.org/10.5067/MEASURES/SO2/DATA406, Fioletov et al., 2022).

volcanic↗

First Global Maps of Stratospheric and Tropospheric NO2 from OMI

The Ozone Monitoring Instrument (OMI) was launched successfully in July 2004, as one of four instruments on the EOS Aura satellite. OMI makes hyperspectral measurements that are used to retrieve column densities of critical trace gases, including formaldehyde, BrO, SO2 and NO2 . We present the first results from the OM1 operational NO2 algorithm and demonstrate its ability to retrieve the tropospheric and stratospheric components of NO2. The DOAS method is used to determine slant column densities, and initial air mass factors (AMFs) are used. to give initial estimates of the vertical column densities (VCDs). VCDs from up to 15 consecutive orbits are collected, and a spatial filtering technique is applied to extract the synoptic-scale features characteristic of the stratospheric, field. features to be evidence of tropospheric excess NO2 , and apply an AMF appropriate to polluted conditions, to obtain an improved retrieval of the NO2 total VCD. We describe the assumptions underlying the algorithm in detail, and show global maps of NO2 VCDs, based on the first operational data from OMI.

Bucsela, Eric J.↗

Direct Observations of PMC Local Time Variations by Aura OMI

The Ozone Monitoring Instrument (OMI) on the Aura satellite obtains unique measurements for polar mesospheric cloud (PMC) analysis. Its wide cross-track viewing swath and high along-track spatial resolution makes it possible to directly evaluate PMC occurrence frequency and brightness variations between 6S" and 8S' latitude as a function of local time over a 12-14 h continuous period. OMI PMC local time variations are closely coupled to concurrent variations in measurement scattering angle, so that ice phase function effects must be considered when interpreting the observations. Two different phase functions corresponding to bright and faint clouds are examined in this analysis. OMI observations show maximum frequency and albedo values at 8-10 h local time in the Northern Hemisphere, with decreasing amplitude at higher latitudes. Southern Hemisphere values reach a minimum at 18-20 h LT. Larger variations are seen in Northern Hemisphere data. No statistically significant longitudinal dependence was seen.

DeLand, Matthew T.↗

Comparative Study of Aerosol and Cloud Detected by CALIPSO and OMI

The Ozone Monitoring Instrument (OMI) on the Aura Satellite detects the presence of desert dust and smoke particles (also known as aerosols) in terms of a parameter known as the UV Aerosol Index (UV AI). The Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) mission measures the vertical distribution of aerosols and clouds. Aerosols and clouds play important roles in the atmosphere and climate system. Accurately detecting their presence, altitude, and properties using satellite radiance measurements is a very important task. This paper presents a comparative analysis of the CALIPSO Version 2 Vertical Feature Mask (VFM) product with the (OMI) UV Aerosol Index (UV AI) and reflectivity datasets for a full year of 2007. The comparison is done at regional and global scales. Based on CALIPSO arid OMI observations, the vertical and horizontal extent of clouds and aerosols are determined and the effects of aerosol type selection, load, cloud fraction on aerosol identification are discussed. It was found that the spatial-temporal correlation found between CALIPSO and OMI observations, is strongly dependent on aerosol types and cloud contamination. CALIPSO is more sensitivity to cloud and often misidentifies desert dust aerosols as cloud, while some small scale aerosol layers as well as some pollution aerosols are unidentified by OMI UV AI. Large differences in aerosol distribution patterns between CALIPSO and OMI are observed, especially for the smoke and pollution aerosol dominated areas. In addition, the results found a significant correlation between CALIPSO lidar 1064 nm backscatter and the OMI UV AI over the study regions.

Chen, Zhong↗

The Development of Two Science Investigator-led Processing Systems (SIPS) for NASA's Earth Observation System (EOS)

In 2001, NASA Goddard Space Flight Center's Laboratory for Terrestrial Physics started the construction of a science Investigator-led Processing System (SIPS) for processing data from the Ozone Monitoring Instrument (OMI) which will launch on the Aura platform in mid 2004. The Ozone Monitoring Instrument (OMI) is a contribution of the Netherlands Agency for Aerospace Programs (NIVR) in collaboration with the Finnish Meteorological Institute (FMI) to the Earth Observing System (EOS) Aura mission. It will continue the Total Ozone Monitoring System (TOMS) record for total ozone and other atmospheric parameters related to ozone chemistry and climate. OMI measurements will be highly synergistic with the other instruments on the EOS Aura platform. The LTP previously developed the Moderate Resolution Imaging Spectrometer (MODIS) Data Processing System (MODAPS), which has been in full operations since the launches of the Terra and Aqua spacecrafts in December, 1999 and May, 2002 respectively. During that time, it has continually evolved to better support the needs of the MODIS team. We now run multiple instances of the system managing faster than real time reprocessings of the data as well as continuing forward processing. The new OMI Data Processing System (OMIDAPS) was adapted from the MODAPS. It will ingest raw data from the satellite ground station and process it to produce calibrated, geolocated higher level data products. These data products will be transmitted to the Goddard Distributed Active Archive Center (GDAAC) instance of the Earth Observing System (EOS) Data and Information System (EOSDIS) for long term archive and distribution to the public. The OMIDAPS will also provide data distribution to the OMI Science Team for quality assessment, algorithm improvement, calibration, etc. We have taken advantage of lessons learned from the MODIS experience and software already developed for MODIS. We made some changes in the hardware system organization, database and software to adapt the system for OMI. We replaced the fundamental database system, Sybase, with an Open Source RDBMS called PostgreSQL, and based the entire OMIDAPS on a cluster of Linux based commodity computers rather than the large SGI servers that MODAPS uses. Rather than relying on a central I/O server host, the new system distributes its data archive among multiple server hosts in the cluster. OMI is also customizing the graphical user interfaces and reporting structure to more closely meet the needs of the OMI Science Team. Prior to 2003, simulated OMI data and the science algorithms were not ready for production testing. We initially constructed a prototype system and tested using a 25 year dataset of Total Ozone Mapping Spectrometer (TOMS) and Solar Backscatter Ultraviolet Instrument (SBUV) data. This prototype system provided a platform to support the adaptation of the algorithms for OMI, and provided reprocessing of the historical data aiding in its analysis. In a recent reanalysis of the TOMS data, the OMIDAPS processed 108,000 full orbits of data through 4 processing steps per orbit, producing about 800,000 files (400 GiB) of level 2 and greater data files. More recently we have installed two instances of the OMIDAPS for integration and testing of OM1 science processes as they get delivered from the Science Team. A Test instance of the OMIDAPS has also supported a series of "Interface Confidence Tests" (ICTs) and End-to-End Ground System tests to ensure the launch readiness of the system. This paper will discuss the high-level hardware, software, and database organization of the OMIDAPS and how it builds on the MODAPS heritage system. It will also provide an overview of the testing and implementation of the production OMIDAPS.

Tilmes, Curt↗

Undersampling Correction for Array Detector-Based Satellite Spectrometers

Array detector-based instruments are now fundamental to measurements of ozone and other atmospheric trace gases from space in the ultraviolet, visible, and infrared. The present generation of such instruments suffers, to a greater or lesser degree, from undersampling of the spectra, leading to difficulties in the analysis of atmospheric radiances. We provide extended analysis of the undersampling suffered by modem satellite spectrometers, which include Global Ozone Monitoring Experiment (GOME), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), Ozone Monitoring Instrument (OMI), and Ozone Mapping and Profiler Suite (OMPS). The analysis includes basic undersampling, the effects of binning into separate detector pixels, and the application of high-resolution Fraunhofer spectral data to correct for undersampling in many useful cases.

Chance, Kelly↗