At least 19 records

Local fluctuations of ozone from 16 km to 45 km deduced from in situ vertical ozone profile

A vertical ozone profile obtained by an in situ ozone sonde from 16 km to 45 km, has allowed to observe local ozone concentration variations. These variations can be observed, thanks to a fast measurement system based on a UV absorption KrF excimer laser beam in a multipass cell. Ozone standard deviation versus altitude calculated from the mean is derived. Ozone variations or fluctuations are correlated with the different dynamic zones of the stratosphere.

Moreau, G.↗

Vertical ozone profile results from the Nimbus-4 BUV data

A seven year data set which consists of both total ozone and ozone vertical profiles has been derived from the Nimbus-4 Backscatter Ultraviolet (BUV) experiment. The BUV experiment measures the earth's backscattered solar radiance at 12 wavelengths in the Hartley-Huggins band. The shortest 8 bands are used to determine the vertical ozone profile. The longest four bands are used to determine the total ozone. The present investigation provides a review of the major characteristics of the instrument performance and ozone results during the seven year period of the data set. Attention is given to the data coverage in time and space, the major areas of nonhomogeneous coverage, adjustments made to the basic instrument radiances, long-term trends in the radiances, rocket and balloon measurements, and problems associated with the validation of the satellite data set.

Fleig, A. J.↗

Ozone Vertical Profile Satellite Measurements by S-NPP OMPS, Aura MLS, and Sentinel-5P TROPOMI

NASA has been monitoring ozone variations from space since 1970 with the launch of the Backscatter Ultraviolet instrument (BUV) on Nimbus- 4. Ozone in the Earth’s stratosphere and troposphere plays a crucial role in protecting life from harmful solar UV radiation, and it also influences Earth’s climate. The vertical distribution of ozone is used in modeling forecasts, verifying model analysis and simulations, and improving the measurement of tropospheric ozone that is a toxic constituent of air pollution. The Microwave Limb Sounder (MLS) on the EOS Aura spacecraft has been monitoring long-term continuous stratosphere ozone vertical behaviors since 2004. The Ozone Mapper Profile Suite (OMPS) on the Suomi National Polar-orbiting Partnership (S-NPP) was launched in 2011. Two of its three instruments, the Limb Profiler (LP) and the Nadir Profiler (NP), are designed to map ozone profiles with full global coverage (~6 days for NP) and a high level of vertical accuracy (1-km reporting record for LP) in the stratosphere and upper troposphere. The TROPOspheric Monitoring Instrument (TROPOMI) on the Copernicus Sentinel-5 Precursor (S5P), launched in 2017, aims to retrieve ozone profiles in both the troposphere and up to top-of-atmosphere (TOA) by using UV radiation measurements in a spectral range of 270-320 nm. S5P/TROPOMI ozone profile products are planned to become available in April 2020. This presentation will concentrate on satellite ozone vertical profile data collections from OMPS and MLS which are archived at the NASA Goddard Earth Sciences Data and Information Services Center (GES DISC). TROPOMI ozone vertical profiles for the troposphere and to top-of-atmosphere will become available at NASA GES DISC in 2020. The presentation briefly explores their potential complementary usability in determining three-dimensional ozone global distributions with high temporal and spatial resolutions.

Zeng, Jian↗

Ozone vertical profile changes over South Pole

Important changes in the ozone vertical profile over South Pole, Antarctica have occurred both during the recent period of measurements, 1986-1991, and since an earlier set of soundings was carried out from 1967-1971. From the onset of the 'ozone hole' over Antarctica in the early 1980s, there has been a tendency for years with lower spring ozone amounts to alternate with years with somewhat higher (although still depleted) ozone amounts. Beginning in 1989 there have been three consecutive years of strong depletion although the timing of the breakdown of the vortex has varied from year to year. Comparison of the vertical profiles between the two periods of study reveals the dramatic decreases in the ozone amounts in the stratosphere between 15-21 km during the spring. In addition, it appears that summer values are also now much lower in this altitude region.

Oltmans, S. J.↗

The inversion of stratospheric aerosol and ozone vertical profiles from spacecraft solar extinction measurements

The inversions of multi-channel solar extinction measurements have been analyzed for the 0.35-1.0 micron wavelength region to retrieve stratospheric aerosol and ozone vertical profiles using both the constrained linear inversion scheme and the iterative scheme. The inversions of the multi-wavelength solar extinction data obtained from spacecraft have been analyzed based on the inversion of computer simulated data using various atmospheric models with differing amounts of aerosol and ozone in the stratosphere. The sensitivities of the inversion schemes to different experimental errors are discussed in terms of accuracy and resolution of the retrieved profiles.

Chu, W. P.↗

Importance of a Priori Vertical Ozone Profiles for TEMPO Air Quality Retrievals

Ozone (O3) is a toxic pollutant which plays a major role in air quality. Typically, monitoring of surface air quality and O3 mixing ratios is conducted using in situ measurement networks. This is partially due to high-quality information related to air quality being limited from space-borne platforms due to coarse spatial resolution, limited temporal frequency, and minimal sensitivity to lower tropospheric and surface-level O3. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) satellite is designed to address the limitations of current space-based platforms and to improve our ability to monitor North American air quality. TEMPO will provide hourly data of total column and vertical profiles of O3 with high spatial resolution to be used as a near-real-time air quality product. TEMPO O3 retrievals will apply the Smithsonian Astrophysical Observatory profile algorithm developed based on work from GOME (Global Ozone Monitoring Experiment), GOME-2, and OMI (Ozone Monitoring Instrument). This algorithm is suggested to use a priori O3 profile information from a climatological data-base developed from long-term ozone-sonde measurements (tropopause-based (TB-Clim) O3 climatology). This study evaluates the TB-Clim dataset and model simulated O3 profiles, which could potentially serve as a priori O3 profile information in TEMPO retrievals, from near-real-time data assimilation model products (NASA GMAO's (Global Modeling and Assimilation Office) operational GEOS-5 (Goddard Earth Observing System, Version 5) FP (Forecast Products) model and reanalysis data from MERRA2 (Modern-Era Retrospective analysis for Research and Applications, Version 2)) and a full chemical transport model (CTM), GEOS-Chem. In this study, vertical profile products are evaluated with surface (0-2 kilometers) and tropospheric (0-10 kilometers) TOLNet (Tropospheric Ozone Lidar Network) observations and the theoretical impact of individual a priori profile sources on the accuracy of TEMPO O3 retrievals in the troposphere and at the surface are presented. Results indicate that while the TB-Clim climatological dataset can replicate seasonally-averaged tropospheric O3 profiles, model-simulated profiles from a full CTM resulted in more accurate tropospheric and surface-level O3 retrievals from TEMPO when compared to hourly and daily-averaged TOLNet observations. Furthermore, it is shown that when large surface O3 mixing ratios are observed, TEMPO retrieval values at the surface are most accurate when applying CTM a priori profile information compared to all other data products.

Priori↗

Satellite remote sensing and ozonesonde observation of ozone vertical profile and severe storm development

Two year ozonesonde data, January 1981 to December 1982, observed at four Canadian stations, and two-and-a-half year backscattered ultraviolet experiment data on the Nimbus-4 satellite, April 1970 to August 1972, observed over five U.S. stations, were used to study the relationship between the total ozone, vertical distribution of the ozone mixing ratio, height of half the total ozone, and the variation of local tropopause height. In view of the correlation between the variation of the tropopause height and the possible development of severe storms, a better understanding of the effect of the vertical distribution of the local ozone profile on the variation of the tropopause height can give considerable insight into the development of severe storms.

Hung, R. J.↗

Homogenizing and Estimating the Uncertainty in NOAA's Long-Term Vertical Ozone Profile Records Measured with the Electrochemical Concentration Cell Ozonesonde

NOAA's program of long-term monitoring of the vertical distribution of ozone with electrochemical concentration cell (ECC) ozonesondes has undergone a number of changes over the 50-year record. In order to produce a homogenous data set, these changes must be documented and, where necessary, appropriate corrections applied. This is the first comprehensive and consistent reprocessing of NOAA's ozonesonde data records that corrects for these changes using the rawest form of the data (cell current and pump temperature) in native resolution as well as a point-by-point uncertainty calculation that is unique to each sounding. The reprocessing is carried out uniformly at all eight ozonesonde sites in NOAA's network with differences in sensing solution and ozonesonde types accounted for in the same way at all sites. The corrections used to homogenize the NOAA ozonesonde data records greatly improve the ozonesonde measurements with an average one sigma uncertainty of +/- 4-6% in the stratosphere and +/- 5-20% in the troposphere. A comparison of the integrated column ozone from the ozonesonde profile with co-located Dobson spectrophotometers total column ozone measurements shows agreement within +/- 5% for >70% of the profiles. Very good agreement is also found in the stratosphere between ozonesonde profiles and profiles retrieved from the Solar Backscatter Ultraviolet (SBUV) instruments.

ozonesonde↗

General comparison of ozone vertical profiles obtained by various techniques during the 1983 MAP/GLOBUS campaign

As part of the 1983 MAP/GLOBUS campaign, atmospheric ozone profile measurements were made using a large variety of different techniques both from balloon platforms and the ground. It is shown that, for most techniques, the measured height distributions agree to within + or - 5 percent with the exception of the remote visible absorption method. This + or - 5 percent uncertainty is of the order of the individual intersystem accuracy. It is suggested that since the differences with the visible absorption method are in magnitude rather than in form, the absorption cross-section data could be the possible cause for the discrepancy.

Matthews, W. A.↗

Algorithm for vertical ozone profile determination for the Nimbus-4 BUV data set

A description is provided of the algorithm used by the Ozone Processing Team at NASA to process seven years of Backscatter Ultraviolet (BUV) ozone profile data. The algorithm is a modification of the original retrieval algorithm developed by Mateer (1972) to process some of the early data from the BUV experiment. Principal changes made are in the first guess selection scheme, the use of all wavelengths in the inversion, and the weighting of the various wavelengths according to the errors in the radiance estimation. It is found that the described BUV ozone profile algorithm is an extremely efficient algorithm for retrieving large amounts of satellite data. The algorithm makes full use of all the available information from the measured radiances including the longer wavelength radiances which previously had not been used.

Bhartia, P. K.↗

Vertical ozone profile determination from Nimbus-7 SBUV measurements

An inversion algorithm is presented, which is used to process Nimbus-7 solar backscattered UV (SBUV) data collected between November 1978 and October 1980. The SBUV experiment utilizes a double monochromator in the nadir position which measures the backscattered solar radiation in twelve 1-nm bands; a separate photometer measures the radiance at 343.0 nm in the field of view coincident with the monochromator. The primary output of the inversion is the total ozone content in umkehr layers in units of m atm cm. In addition, the diagonal elements of the covariance matrix are reported; they represent the uncertainty in the derived ozone content in each layer. The solution covariance is noted to be independent of the measurements.

Klenk, K. F.↗

Cloud, dust, and ozone vertical profiles from solar occultation measurements: Implications for dynamics

An instrument was designed for solar occultation measurements of the martian atmosphere from the Phobos spacecraft. It was composed of three different dispersive systems working in the ultraviolet (UV: 0.22-0.32 microns) for the measurement of O3 and aerosols, in the near infrared (NIR: 0.76 microns, 0.94 microns) for the detection of O2 and H2O, and in the infrared (IR: 1.9 microns, 3.7 microns) where CO2 and H2O were measured. A detailed description of the instrument may be found in the special issue of Nature. Its principle objective is to measure from the Phobos orbit the spectrum of the Sun, modified by atmospheric extinction, during sunset. The UV-NIR spot has an angular diameter of 1 arcmin, or approximately 3 km vertical resolution, and is located near the center of the solar disk. The IR field is about twice as large and its line of sight is shifted by 8.5 arcmin, or approximately 20 km, relative to the previous one. It is therefore located near the edge of the solar disk. Sampling times are generally 0.5, 1, and 2 s for IR, UV, and NIR channels respectively, corresponding to vertical excursions of the line of sight of 1, 2, and 4 km respectively under nominal conditions. The instrument operated from February 8 to March 26 (the martian equinox occurred on February 17). The latitude of the intersection of the Sun-spacecraft axis with the surface of Mars varied from -11 to +20, the seasonal date L(sub s) being in the range 0 - 20. All measurements were therefore made near northern spring equinox in equatorial regions. Due to an error in the pointing system, only partial results were obtained, the region below approximately equals 30 km altitude being never sounded by the UV-NIR spectrometer. On the contrary, nine complete occultations were obtained in the IR channels, whose line of sight was fortunately approximately equals 20 km below the UV-NIR axis.

Chassefiere, E.↗

Vertical ozone profile comparisons between ozonesondes and remote instrumentation

The ozone profiles measured with the halogen occultation experiment (HALOE) instrument and the microwave limb sounder (MLS) instrument, on NASA's upper atmosphere research satellite (UARS), are compared to those obtained with the electrochemical concentration cell (ECC) ozone sonde. The process used to assure the quality of the ozone sonde measurements, the comparisons between the ozone sonde and other measuring instruments, and the reliability of measurements in space are discussed.

Schmidlin, F. J.↗

Vertical Ozone Profile Comparisons Between Ozonesondes and Remote Instrumentation

Ozonesonde measurement quality is a critical factor for insuring measurement accuracy and is fundamentally indispensable for validating remotely measured ozone. Reasonable results from such ozone profile comparisons are best obtained by maintaining the smallest possible spatial and time differences between ozonesonde and remote measurement observations. Ozone profiles measured with the Halogen Occultation Experiment (HALOE) instrument and the Microwave Limb Sounder (MLS) instrument on NASA's Upper Atmosphere Research Satellite (UARS) are compared with ECC profiles. Comparisons with the GSFC ozone lidar also demonstrate good agreement. In this paper we show: (1) the process used by NASA to secure quality ozonesonde measurements, (2) comparisons of ozonesondes with various remote sensing instruments and, (3) the reliability obtained when both measurement types are obtained close in time and, when possible, in space.

Schmidlin, F. J.↗

On vertical profile of ozone at Syowa

The difference in the vertical ozone profile at Syowa between 1966-1981 and 1982-1988 is shown. The month-height cross section of the slope of the linear regressions between ozone partial pressure and 100-mb temperature is also shown. The vertically integrated values of the slopes are in close agreement with the slopes calculated by linear regression of Dobson total ozone on 100-mb temperature in the period of 1982-1988.

Chubachi, Shigeru↗