Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ozonesondes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The 1998-2000 SHADOZ (Southern Hemisphere ADditional OZonesondes) Tropical Ozone Climatology: Ozonesonde Precision, Accuracy and Station-to-Station Variability

As part of the SAFARI-2000 campaign, additional launches of ozonesondes were made at Irene, South Africa and at Lusaka, Zambia. These represent campaign augmentations to the SHADOZ database described in this paper. This network of 10 southern hemisphere tropical and subtropical stations, designated the Southern Hemisphere ADditional OZonesondes (SHADOZ) project and established from operational sites, provided over 1000 profiles from ozonesondes and radiosondes during the period 1998-2000. (Since that time, two more stations, one in southern Africa, have joined SHADOZ). Archived data are available at: http://code9l6.gsfc.nasa.gov/Data-services/shadoz>. Uncertainties and accuracies within the SHADOZ ozone data set are evaluated by analyzing: (1) imprecisions in stratospheric ozone profiles and in methods of extrapolating ozone above balloon burst; (2) comparisons of column-integrated total ozone from sondes with total ozone from the Earth-Probe/TOMS (Total Ozone Mapping Spectrometer) satellite and ground-based instruments; (3) possible biases from station-to-station due to variations in ozonesonde characteristics. The key results are: (1) Ozonesonde precision is 5%; (2) Integrated total ozone column amounts from the sondes are in good agreement (2-10%) with independent measurements from ground-based instruments at five SHADOZ sites and with overpass measurements from the TOMS satellite (version 7 data). (3) Systematic variations in TOMS-sonde offsets and in groundbased-sonde offsets from station to station reflect biases in sonde technique as well as in satellite retrieval. Discrepancies are present in both stratospheric and tropospheric ozone. (4) There is evidence for a zonal wave-one pattern in total and tropospheric ozone, but not in stratospheric ozone.

Witte, J. C.↗

SHADOZ (Southern Hemisphere ADditional OZonesondes): An Ozonesonde Network and Resource for Remote Sensing Research and Education

Balloon-borne ozone instrumentation (ozonesondes), launched at fixed sites, is used to study local patterns in stratospheric and tropospheric ozone and to provide validation for satellite ozone products and model calculations of ozone. A paucity of coordinated ozonesonde data in the southern hemisphere tropics is being remedied in a 3-year project of coordinated ozonesondes launches at 10 sites. The data are available to the scientific community at the SHADOZ website at NASA/Goddard. Stations and their operational characteristics, with examples of ozone observations, are given. One expectation of SHADOZ is that wide dissemination of data and interaction with users and field projects will leverage local funding to maintain infrastructure and operations. SHADOZ data are well-suited for educational projects in which students learn about regional ozone patterns.

Thompson, Anne M.↗

SHADOZ (Southern Hemisphere ADditional OZonesondes): An Ozonesonde Network for Satellite Validation, Climatology and Modeling

In the past 5 years, new tropical ozone data products have been developed from TOMS and other satellites, During this period, global chemical-transport models have been used for ozone assessment studies. However, there has been a lack of independent ozone profiles in the tropics for evaluation of the data sets and models. In 1998, NASA's Goddard Space Flight Center, Wallops Flight Facility and NOAA's CMDL (Climate Monitoring and Diagnostics Lab), began a 2-year project to collect a consistent data set by augmenting ozonesonde launches at southern hemisphere tropical sites The measurements are available to the scientific community at a single electronic location - the SHADOZ website at NASA/Goddard: http://code9l6.gsfc.nasa.gov/Data services/Shadoz/shadoz hmpg2.html. Stations in SHADOZ include four islands in the Pacific: Fiji, Tahiti, San Cristobal (Galapagos) and American Samoa. Two sites are at and in the Atlantic: Natal (Brazil) and Ascension Island. Three other sites span Africa (Nairobi and Irene, South Africa) and the Indian Ocean (Reunion Island and Watukosek in Java, Indonesia). All SHADOZ sites are using ECC-type sondes, with the conversion from JMD sondes at Java in 1999, but there are variations in sonde preparation technique and data processing. During the 1998-1999 period, more than 550 sondes were incorporated into the SHADOZ data base. Examples from these measurements illustrate the tropical wave-one pattern in total ozone which is easily detectable by satellite. They also show that the wave-one pattern appears to be in the troposphere, as assumed in creating the modified-residual tropospheric ozone data product from TOMS. SHADOZ will add data from intensive field campaigns from time to time. Recent contributions to the SHADOZ archive are from the INDOEX (Indian Ocean Experiment January-March 1999)sondes at the Maldives (5N, 73E) and 27 sondes on the US NOAA oceanographic vessel, the FIN Ronald H Brown between Virginia (US) and Mauritius via CapeTown, during a cruise in January and February 1999. In 2000, as part of the SAFARI-2000 experiment and a validation project called Southern African Validation for EOS (SAVE), enhancement of ozonesonde launches at Irene (South Africa) will extend the data set from this site beyond the 1998-1999 period.

Thompson, Anne M.↗

SHADOZ (Southern Hemisphere Additional Ozonesondes): A Tropical Ozonesonde-Radiosonde Network for the Atmospheric Community

A lack of sounding data has limited the accuracy of ozone satellite retrievals in the tropics and our understanding of chemical-dynamical interactions in a region strongly influenced by natural variability and anthropogenic activity. In 1998, NASA s Goddard Space Flight Center, NOAA's Climate Monitoring and Diagnostics Laboratory (CMDL) and a team of international sponsors established the SHADOZ (Southern Hemisphere ADditional OZonesondes) project to address the gap in tropical ozone soundings. SHADOZ augments launches at selected sites and provides a public archive of ozonesonde and radiosonde data from twelve tropical and subtropical stations at http://croc.gsfc.nasa.gov/shadoz. Instrumentation, data and a summary of the first scientific findings from SHADOZ are presented.

Thompson, Anne M.↗

SHADOZ (Southern Hemisphere ADditional OZonesondes): A New Ozonesonde Data Set for the Earth Science Community

In the past several years, new tropical tropospheric ozone data products have been developed from TOMS and other satellites. Global chemical-transport models have been developed for interpretation of satellite data and to predict future ozone levels in the troposphere and stratosphere. However, the lack of ozone profile measurements for validation and evaluation of these data sets and models is critical in regions like the tropics. In 1998 NASA/Goddard Space Flight Center, in partnership with NOAA/CMDL (Climate Monitoring and Diagnostics Lab) and other nations, began a 2-year project to collect weekly ozonesonde measurements at southern hemisphere tropical sites and make the data available to the scientific community at a single electronic location: http://code9lQ.gsfc.nasa.gov/Data services/Shadoz/shadoz hmpq2.htmi A summary of data from the SHADOZ sites will be presented: Ascension Island, Fiji, Tahiti, Galapagos, American Samoa, Natal (Brazil), Reunion Island, Watukosek (Java), Nairobi and Irene, South Africa. SHADOZ is designed to meet other needs: (1) Provide the first climatology of tropical ozone along the equatorial zone for the wave-one pattern in total ozone; (2) Supplement field project observations. (3) Guide algorithm development for future satellite instruments; (4) Train scientists and educators in southern hemisphere tropical locations. From time to time, intensive tropical campaigns are making data available to SHADOZ. Data from the first half of 1999 will include INDOEX (Indian Ocean Experiment), SOWER (Stratospheric Ozone and Water in the Equatorial Region) at Christmas Island (2N, 157W), and a cruise from Norfolk, Virginia to Cape Town and Mauritius on NOAA's RN 'Ronald H Brown.'

Witte, J. C.↗

Homogenizing and Estimating the Uncertainty in NOAA's Long-Term Vertical Ozone Profile Records Measured with the Electrochemical Concentration Cell Ozonesonde

NOAA's program of long-term monitoring of the vertical distribution of ozone with electrochemical concentration cell (ECC) ozonesondes has undergone a number of changes over the 50-year record. In order to produce a homogenous data set, these changes must be documented and, where necessary, appropriate corrections applied. This is the first comprehensive and consistent reprocessing of NOAA's ozonesonde data records that corrects for these changes using the rawest form of the data (cell current and pump temperature) in native resolution as well as a point-by-point uncertainty calculation that is unique to each sounding. The reprocessing is carried out uniformly at all eight ozonesonde sites in NOAA's network with differences in sensing solution and ozonesonde types accounted for in the same way at all sites. The corrections used to homogenize the NOAA ozonesonde data records greatly improve the ozonesonde measurements with an average one sigma uncertainty of +/- 4-6% in the stratosphere and +/- 5-20% in the troposphere. A comparison of the integrated column ozone from the ozonesonde profile with co-located Dobson spectrophotometers total column ozone measurements shows agreement within +/- 5% for >70% of the profiles. Very good agreement is also found in the stratosphere between ozonesonde profiles and profiles retrieved from the Solar Backscatter Ultraviolet (SBUV) instruments.

ozonesonde↗

Ozonesonde Quality Assurance: JOSIE-SHADOZ (2017) and SHALLOTS (2018)

Ozonesonde data constitute a mainstay of satellite calibration and are used for climatologies and analysis of trends, especially in the lower stratosphere where satellites are most uncertain. The electrochemical-concentration cell (ECC) ozonesonde has been deployed at ~100 stations worldwide since the 1960s, with changes over time in manufacture and procedures, including details of the cell chemical solution and data processing. As a consequence, there are biases among different stations and discontinuities in profile timeseries from individual site records. Since 1996 the Jülich [Germany] Ozone Sonde Intercomparison Experiment (JOSIE) has periodically tested ozonesondes in a simulation chamber designated the World Calibration Centre for Ozonesondes by WMO. In October- November 2017 a JOSIE campaign evaluated the sondes and procedures used in SHADOZ (Southern Hemisphere Additional Ozonesondes), a 14-station tropical and subtropical network. A distinctive feature of the 2017 JOSIE was that the tests were conducted by operators from eight SHADOZ stations; Nairobi, Natal, Irene, Costa Rica, Paramaribo, Reunion, Hanoi, Kuala Lumpur. Experimental protocols and preliminary results for the SHADOZ sonde configurations, which represent most of those in use today, are described. SHADOZ stations that follow WMO-recommended protocols record total ozone within 3% of the JOSIE reference instrument. Instrument biases noted in prior JOSIE and field tests like BESOS (2004) were noted in JOSIE-2017, with maximum effect in the stratosphere. In June 2018 we organized a series of dual launches during the OWLETS II campaign in the Maryland and Chesapeake Bay area (SHALLOTS = SHADOZ-OWLETS ParaLLel Ozonesonde Test Study). Instrument and solution types were varied as in JOSIE-2017 and three radiosonde-ozonesonde variants were tested. An example of a parallel sampling in SHALLOTS, from a Greenbelt EnSCI-iMet sonde combination flown with the Wallops SPCLMS package, is illustrated in the Figure. The result was a range of biases but in general the instrument combination (EnSCI-iMet) deployed at 11 SHADOZ stations recorded ~5-10% less ozone in the stratosphere than the SPC ECC sonde flown with a Vaisala or LMS system. These 2017 and 2018 results and prior JOSIEs demonstrate that regular testing is essential to maintain best practices in ozonesonde operations and to ensure high-quality data for the ozone assessment communities.

Quality assurance↗

The Southern Hemisphere Additional Ozonesondes (SHADOZ) 1998-2002 Tropical Ozone Climatology: Instrumentation and Station-to-Station Variability - 3

Abstract: Since 1998 the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has collected more than 2000 ozone profiles from a dozen tropical and subtropical sites using balloon-borne electrochemical concentration cell (ECC) ozonesondes. The data (with accompanying pressure-temperature-humidity soundings) are archived. Analysis of ozonesonde imprecision within the SHADOZ dataset revealed that variations in ozonesonde technique could lead to station-to-station biases in the measurements. In this paper imprecisions and accuracy in the SHADOZ dataset are examined in light of new data. When SHADOZ total ozone column amounts are compared to version 8 TOMS (2004 release), discrepancies between sonde and satellite datasets decline 1-2 percentage points on average, compared to version 7 TOMS. Variability among stations is evaluated using total ozone normalized to TOMS and results of laboratory tests on ozonesondes (JOSE-2O00, Julich Ozonesonde Intercomparison Experiment). Ozone deviations from a standard instrument in the JOSE flight simulation chamber resemble those of SHADOZ station data relative to a SHADOZ-defined climatological reference. Certain systematic variations in SHADOZ ozone profiles are accounted for by differences in solution composition, data processing and instrument (manufacturer). Instrument bias leads to a greater ozone measurement above 25 km over Nairobi and to lower total column ozone at three Pacific sites compared to other SHADOZ stations at 0-20 deg.S.

Thompson, Anne M.↗

Propagation of Radiosonde Pressure Sensor Errors to Ozonesonde Measurements

Several previous studies highlight pressure (or equivalently, pressure altitude) discrepancies between the radiosonde pressure sensor and that derived from a GPS flown with the radiosonde. The offsets vary during the ascent both in absolute and percent pressure differences. To investigate this problem further, a total of 731 radiosonde-ozonesonde launches from the Southern Hemisphere subtropics to Northern mid-latitudes are considered, with launches between 2005 - 2013 from both longer-term and campaign-based intensive stations. Five series of radiosondes from two manufacturers (International Met Systems: iMet, iMet-P, iMet-S, and Vaisala: RS80-15N and RS92-SGP) are analyzed to determine the magnitude of the pressure offset. Additionally, electrochemical concentration cell (ECC) ozonesondes from three manufacturers (Science Pump Corporation; SPC and ENSCI-Droplet Measurement Technologies; DMT) are analyzed to quantify the effects these offsets have on the calculation of ECC ozone (O3) mixing ratio profiles (O3MR) from the ozonesonde-measured partial pressure. Approximately half of all offsets are 0.6 hPa in the free troposphere, with nearly a third 1.0 hPa at 26 km, where the 1.0 hPa error represents 5 persent of the total atmospheric pressure. Pressure offsets have negligible effects on O3MR below 20 km (96 percent of launches lie within 5 percent O3MR error at 20 km). Ozone mixing ratio errors above 10 hPa (30 km), can approach greater than 10 percent ( 25 percent of launches that reach 30 km exceed this threshold). These errors cause disagreement between the integrated ozonesonde-only column O3 from the GPS and radiosonde pressure profile by an average of +6.5 DU. Comparisons of total column O3 between the GPS and radiosonde pressure profiles yield average differences of +1.1 DU when the O3 is integrated to burst with addition of the McPeters and Labow (2012) above-burst O3 column climatology. Total column differences are reduced to an average of -0.5 DU when the O3 profile is integrated to 10 hPa with subsequent addition of the O3 climatology above 10 hPa. The RS92 radiosondes are superior in performance compared to other radiosondes, with average 26 km errors of -0.12 hPa or +0.61 percent O3MR error. iMet-P radiosondes had average 26 km errors of -1.95 hPa or +8.75 percent O3MR error. Based on our analysis, we suggest that ozonesondes always be coupled with a GPS-enabled radiosonde and that pressure-dependent variables, such as O3MR, be recalculated-reprocessed using the GPS-measured altitude, especially when 26 km pressure offsets exceed 1.0 hPa 5 percent.

pressure measurements↗

Electrochemical concentration cell ozonesonde accuracy and precision

This paper is concerned with the results of a study designed to evaluate experimentally the accuracy and precision of electrochemical concentration cell (ECC) ozonesondes as prepared and flown by NASA, as a function of altitude. A combination of dual-instrument soundings and laboratory work using an environmental chamber was employed in the study. The ECC ozonesonde is a small, balloon-borne sensor developed for obtaining vertical profiles of atmospheric ozone. Attention is given to the design of the employed environmental chamber, ozone and temperature profiles used in simulated ozonesonde soundings, absolute and relative ECC ozonesonde precision estimates determined with the environmental chamber and from dual-instrument balloon soundings, and the ECC ozonesonde accuracy.

Barnes, R. A.↗

Accuracy and Precision in the Southern Hemisphere Additional Ozonesondes (SHADOZ) Dataset in Light of the JOSIE-2000 Results

Since 1998 the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has provided over 2000 ozone profiles over eleven southern hemisphere tropical and subtropical stations. Balloon-borne electrochemical concentration cell (ECC) ozonesondes are used to measure ozone. The data are archived at: &ttp://croc.gsfc.nasa.gov/shadoz>. In analysis of ozonesonde imprecision within the SHADOZ dataset, Thompson et al. [JGR, 108,8238,20031 we pointed out that variations in ozonesonde technique (sensor solution strength, instrument manufacturer, data processing) could lead to station-to-station biases within the SHADOZ dataset. Imprecisions and accuracy in the SHADOZ dataset are examined in light of new data. First, SHADOZ total ozone column amounts are compared to version 8 TOMS (2004 release). As for TOMS version 7, satellite total ozone is usually higher than the integrated column amount from the sounding. Discrepancies between the sonde and satellite datasets decline two percentage points on average, compared to version 7 TOMS offsets. Second, the SHADOZ station data are compared to results of chamber simulations (JOSE-2000, Juelich Ozonesonde Intercomparison Experiment) in which the various SHADOZ techniques were evaluated. The range of JOSE column deviations from a standard instrument (-10%) in the chamber resembles that of the SHADOZ station data. It appears that some systematic variations in the SHADOZ ozone record are accounted for by differences in solution strength, data processing and instrument type (manufacturer).

Witte, Jacquelyn C.↗

First Reprocessing of Southern Hemisphere ADditional OZonesondes (SHADOZ) Profile Records (1998-2015): 1. Methodology and Evaluation

Electrochemical concentration cell ozonesonde measurements are an important source of highly resolved vertical profiles of ozone with long-term data records for deriving ozone trends, model development, satellite validation, and air quality studies. Ozonesonde stations employ a range of operational and data processing procedures, metadata reporting, and instrument changes that have resulted in inhomogeneities within individual station data records. A major milestone is the first reprocessing of seven Southern Hemisphere ADditional OZonesondes (SHADOZ) station ozonesonde records to account for errors and biases in operating/processing procedures. Ascension Island, Hanoi, Irene, Kuala Lumpur, La Reunion, Natal, and Watukosek station records all show an overall increase in ozone after reprocessing. Watukosek shows the largest increase of 9.0 plus or minus 2.1 Dobson Units (DU) in total column ozone; Irene and Hanoi show a 5.5 plus or minus 2.5 DU increase, while remaining sites show statistically insignificant enhancements. Negligible to modest ozone enhancements are observed after reprocessing in the troposphere (up to 8%) and stratosphere (up to 6%), except at La Reunion for which the application of background currents reduces tropospheric ozone (2.1 plus or minus1.3 DU). Inhomogeneities due to ozonesonde/solution-type changes at Ascension, Natal, and La Reunion are resolved with the application of transfer functions. Comparisons with EP-TOMS, Aura's Ozone Monitoring Instrument and Microwave Limb Sounder (MLS) satellite ozone overpasses show an overall improvement in agreement after reprocessing. Most reprocessed data sets show a significant reduction in biases with MLS at the ozone maximum region (50-10 hPa). Changes in radiosonde/ozonesonde system and nonstandard solution types can account for remaining discrepancies observed at several sites when compared to satellites.

Electrochemical concentration cell ozonesonde meas↗

Chapter 4 - Ozonesondes: Instrumentation and Data Applications

The ozonesonde instrument, launched on a standard weather balloon along with a radiosonde, has been used for more than 50 years to measure ozone concentrations in the troposphere to mid-stratosphere. The measurement is based on an electrochemical reaction, avoiding associated with optical techniques, and can achieve a 5% or better accuracy and precision when careful preparation and data-processing methods are employed. Instrument details are described and the global ozonesonde network illustrated. The use of the ozonesonde in the complement of ground-based instruments that validate satellite ozone instruments is described. Satellite data in turn help maintain consistency of long-term ozonesonde measurements.

tropospheric ozone↗

Performance characteristics of the electrochemical concentration cell ozonesonde

A large number of electrochemical concentration cell (ECC) ozonesondes were calibrated in relation to a UV photometric absorption ozone instrument prior to using the ozonesondes in atmospheric soundings. The two methods of measuring ozone were in reasonable agreement on the average, but there was considerable variation from one ozonesonde to another. Averaging the individual linear regressions gives an ECC ozone concentration equal to 0 + or - 8 nbar plus (0.96 + or - 0.10) times the concentration determined with the UV instrument, where uncertainties represent 90% confidence limits. Applying individual calibration corrections to atmospheric sounding data reduced the mean difference between Dobson spectrophotometric measurements of total ozone overburdens and corresponding values obtained from ozonesonde data from -8.5 + or - 8.2 to -1.4 + or - 7.3% for a series of measurements carried out in 1977. Corresponding uncorrected and corrected differences averaged 3.2 + or - 9.7 and 1.9 + or - 10.6%, respectively, for soundings carried out in 1976.

Torres, A. L.↗

Distribution of tropospheric ozone at Brazzaville, Congo, determined from ozonesonde measurements

An analysis of 33 ozonesonde launches in Brazzaville, Congo (4 deg S, 15 deg E), between June 1990 and May 1991 is presented. The data indicate highest tropospheric amounts between June and early October, coincident with the dry season and with the presence of enhanced widespread biomass burning. The seasonal cycle of ozone derived from the ozonesonde measurements is in good agreement with the climatological seasonal cycle inferred from the use of satellite data amd both seasonal cycles peak in September. Averaged throughout the year, the integrated amount of ozone derived from the ozonesondes is 44 Dobson units (DU) and is 39 DU using the satellite data. Within the troposphere the highest partial pressures are generally found at pressure levels near 700 mbar (about 3 km). Using simultaneous ozonesonde data from Ascension Island (8 deg S, 15 deg W), examples are presented illustrating that differences in the troposphere are primarily responsible for the observed spatial gradients of total ozone observed by TOMS.

Cros, Bernard↗

Vertical Ozone Profile Comparisons Between Ozonesondes and Remote Instrumentation

Ozonesonde measurement quality is a critical factor for insuring measurement accuracy and is fundamentally indispensable for validating remotely measured ozone. Reasonable results from such ozone profile comparisons are best obtained by maintaining the smallest possible spatial and time differences between ozonesonde and remote measurement observations. Ozone profiles measured with the Halogen Occultation Experiment (HALOE) instrument and the Microwave Limb Sounder (MLS) instrument on NASA's Upper Atmosphere Research Satellite (UARS) are compared with ECC profiles. Comparisons with the GSFC ozone lidar also demonstrate good agreement. In this paper we show: (1) the process used by NASA to secure quality ozonesonde measurements, (2) comparisons of ozonesondes with various remote sensing instruments and, (3) the reliability obtained when both measurement types are obtained close in time and, when possible, in space.

Schmidlin, F. J.↗

Seasonal Characteristics of Tropical Ozone Profiles using the SHADOZ Ozonesonde Data Set: Comparisons with TOMS Tropical Ozone Climatology

Advances in tropospheric ozone data products being developed for tropical and subtropical regions using TOMS (Total Ozone Mapping Spectrometer) and other satellites are motivating efforts to renew and expand the collection of balloon-borne ozonesonde observations. The SHADOZ (Southern Hemisphere ADditional OZonesondes) project is a web-based archive established since 1998. It's goals are to support validation of TOMS and SBUV (Solar Backscatter UV) satellite ozone measurements and to improve remote sensing techniques for estimating tropical and subtropical ozone. Profile data are taken from balloon-borne ozonesondes, currently at 11 stations coordinating weekly to bi-weekly launches. Station data are publically available at a central location via the internet: . Since the start of the project, the SHADOZ archive has accumulated over 1500 ozonesonde profiles. Data also includes measurements from various SHADOZ supported field campaigns, such as, the Indian Ocean Experiment (INDOEX), Sounding of Ozone and Water in the Equatorial Region (SOWER) and Aerosols99 Atlantic Cruise. Using data from the archive, profile climatologies from selected stations will be shown to 1/characterize the variability of tropospheric tropical ozone among stations, 2/illustrate the seasonal offsets with respect to the tropical profile used in the TOMS v7 algorithm, and 3/estimate the potential error in TOMS retrieval estimates of the tropospheric portion of the atmosphere.

Witte, J. C.↗