Search NASA⌕ Search

SEARCH · Search NASA

Results for “PARTICLE SIZE CLASSIFIERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Size-Resolved Density Measurements of Particulate Emissions from an Advanced Combustion Diesel Engine: Effect of Aggregate Morphology

We report the first in situ size-resolved density measurements of particles produced by premixed charge compression ignition (PCCI) and compare these with conventional diesel particles. The densities of size-classified particles were determined by measurements with a differential mobility analyzer (DMA) and an aerosol particle mass analyzer (APM). Particle masses of the different size classes were evaluated with a proposed DMA-APM response function for aggregates. Our results indicate that the effective densities of PCCI and conventional diesel particles were approximately the same for 50 and 100 nm electrical mobility diameters (0.9 and 0.6 g/cc, respectively), but the PCCI particle effective density (0.4 g/cc) was less than the conventional (0.5 g/cc) for 150 nm. The lowest effective particle densities were observed for exhaust gas recirculation (EGR) levels somewhat less than that required for PCCI operation. The inherent densities of conventional particles in the 50 and 100 nm size classes were 1.22 and 1.77 g/cc, which is in good agreement with Park et al. (2004). PCCI inherent particle densities for these same size classes were higher (1.27 and 2.10 g/cc), suggesting that there may have been additional adsorbed liquid hydrocarbons. For 150 nm particles, the inherent densities were nearly the same for PCCI and conventional particles at 2.20 g/cc. We expect that the lower effective density of PCCI particles may improve particulate emissions control with diesel particulate filters (DPFs). The presence of liquid hydrocarbons may also promote oxidation in DPFs.

33 ADVANCED PROPULSION SYSTEMS↗

Extending the Capabilities of Single Particle Mass Spectrometry: II. Measurements of Aerosol Particle Density without DMA

Particle density is an important and useful property that is difficult to measure because it usually 5 requires separate instruments to measure two particle attributes. As density measurements are 6 often performed on size-classified particles, they are hampered by low particle numbers, and 7 hence poor temporal resolution. We present here a new method for measuring particle densities 8 using our single particle mass spectrometer, SPLAT. This method takes advantage of the fact 9 that the detection efficiency in our single particle mass spectrometer drops off very rapidly as the 10 particle size decreases below ~125 nm creating a distinct sharp feature on the small particle side 11 of the vacuum aerodynamic size distribution. Thus, the two quantities needed to determine 12 particle density, the particle diameter and vacuum aerodynamic diameter, are known. We first 13 test this method on particles of known composition and find that the densities it yields are 14 sufficiently accurate. We then apply the method to obtain the densities of particles that were 15 characterized during an airborne field campaign. In addition, we show that the distinctive 16 features of the vacuum aerodynamic size distribution can be used to characterize the instrument 17 detection efficiency as a function of particle size. In general, the method presented here reduces 18 complexity and yields information with high temporal resolution while the instrument is 19 collecting routine data on particle size and composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A New Real-Time Method for Determining Particles Sphericity and Density: Application to Secondary Organic Aerosol Formed by Ozonolysis of alpha-Pinene

Particle volumes are most often obtained by measuring particle mobility size distributions and assuming that the particles are spherical. These volumes are then converted to mass loads by using particle densities that are commonly either assumed or estimated from the measured mobility and vacuum aerodynamic diameters assuming again that the particles are spherical. Depending on the system, these assumptions can introduce significant errors. We present a new method that can be applied to any particle system to determine in real-time whether the particles are spherical or not. We use our 2nd generation single particle mass spectrometer (SPLAT II) to measure with extremely high precision the vacuum aerodynamic size distributions of particles classified by differential mobility analyzer (DMA) and demonstrate that the line shape of these distributions provide a way to unambiguously distinguish between spherical and aspherical particles. Moreover, the very same experimental system is used to obtain in addition to individual particle size, its density, composition and dynamic shape factor. We illustrate the application of this method to secondary organic aerosols formed as a result of ozonolysis of α-pinene in the presence and absence of an OH scavenger and find these particles to be spherical with densities of 1.198±0.004 gcm-3 and 1.213±0.003 gcm-3 respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid measurement of sub-micrometer aerosol size distribution using a fast integrated mobility spectrometer

We present rapid measurement of submicron particle size distributions enables the characterization of aerosols with fast changing properties, and is often necessary for measurements onboard mobile platforms (e.g., research aircraft). Aerosol mobility size distribution is commonly measured by a scanning mobility particle sizer (SMPS), which relies on voltage scanning or stepping to classify particles of different sizes, and may take up to several minutes to obtain a complete size spectrum of aerosol particles. The recently developed fast integrated mobility spectrometer (FIMS) with enhanced dynamic size range classifies and detects particles from 10 to ~600 nm simultaneously, allowing submicron aerosol mobility size distributions to be captured at a time resolution of 1 second. In this study, we present a detailed data inversion routine for deriving aerosol size distribution from FIMS measurements. The inversion routine takes into consideration the FIMS transfer function, particle penetration efficiency in the FIMS, and multiple charging of aerosols. The accuracy of the FIMS measurement is demonstrated by comparing parallel FIMS and SMPS measurements of stable aerosols with a wide range of size spectrum shapes, including ambient aerosols and aerosols classified by a differential mobility analyzer (DMA). The FIMS and SMPS-derived size distributions show excellent agreements for all aerosols tested. In addition, total number concentrations of ambient aerosols were integrated from 1 Hz FIMS size distributions, and compared with those directly measured by a condensation particle counter (CPC) operated in parallel. Finally, the integrated and measured total particle concentrations agree well within 5%.

54 ENVIRONMENTAL SCIENCES↗

Note: Evaluation of slurry particle size analyzers for chemical mechanical planarization process

In the chemical mechanical planarization (CMP) process, slurry particle size is important because large particles can cause defects. Hence, selection of an appropriate particle measuring system is necessary in the CMP process. In this study, a scanning mobility particle sizer (SMPS) and dynamic light scattering (DLS) were compared for particle size distribution (PSD) measurements. In addition, the actual particle size and shape were confirmed by transmission electron microscope (TEM) results. SMPS classifies the particle size according to the electrical mobility, and measures the particle concentration (single particle measurement). On the other hand, the DLS measures the particle size distribution by analyzing scattered light from multiple particles (multiple particle measurement). For the slurry particles selected for evaluation, it is observed that SMPS shows bi-modal particle sizes 30 nm and 80 nm, which closely matches with the TEM measurements, whereas DLS shows only single mode distribution in the range of 90 nm to 100 nm and showing incapability of measuring small particles. Hence, SMPS can be a better choice for the evaluation of CMP slurry particle size and concentration measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KNIFE MILL COMMINUTION ENERGY ANALYSIS OF SWITCHGRASS, WHEAT STRAW, AND CORN STOVER AND CHARACTERIZATION OF PARTICLE SIZE DISTRIBUTIONS

Biomass preprocessing and pretreatment technologies such as size reduction and chemical preconditioning are aimed at reducing the cost of ethanol production from lignocellulosic biomass. Size reduction is an energy-intensive biomass preprocessing unit operation. In this study, switchgrass, wheat straw, and corn stover were chopped in an instrumented knife mill to evaluate size reduction energy and corresponding particle size distribution as determined with a standard forage sieve analyzer. Direct mechanical power inputs were determined using a dedicated data acquisition system for knife mill screen openings from 12.7 to 50.8 mm, rotor speeds between 250 and 500 rpm, and mass feed rates from 1 to 11 kg/min. A speed of 250 rpm gave optimum performance of the mill. Optimum feed rates for 25.4 mm screen and 250 rpm were 7.6, 5.8, and 4.5 kg/min for switchgrass, wheat straw, and corn stover, respectively. Total specific energy (MJ/Mg) was defined as the size reduction energy required to operate the knife mill plus that imparted to the biomass. Effective specific energy was defined as the energy imparted to the biomass. For these conditions, total specific energies were 27.3, 37.9, and 31.9 MJ/Mg and effective specific energies were 10.1, 15.5, and 3.2 MJ/Mg for switchgrass, wheat straw, and corn stover, respectively. These results demonstrated that biomass selection affects the size reduction energy, even for biomass with similar features. Second-order polynomial equations for the total specific energy requirement fitted well (R2 > 0.95) as a function of knife mill screen size, mass feed rate, and speed for biomass materials tested. The Rosin-Rammler equation fitted the cumulative undersize mass of switchgrass, wheat straw, and corn stover chop passed through ASABE sieves with high R2 (>0.983). Knife mill chopping of switchgrass, wheat straw, and corn stover resulted in particle size distributions classified as 'well-graded strongly fine-skewed mesokurtic', 'well-graded fine-skewed mesokurtic', and 'well-graded fine-skewed mesokurtic', respectively, for small knife mill screen sizes (12.7 to 25.4 mm) and distributions classified as 'well-graded fine-skewed mesokurtic', 'well-graded strongly fine-skewed mesokurtic', and 'well-graded fine-skewed mesokurtic', respectively, for the large screen size (50.8 mm). Total and effective specific energy values per unit size reduction of wheat straw were greater compared to those for switchgrass. Corn stover resulted in reduced total and effective specific energy per unit size reduction compared to wheat straw for the same operating conditions, but higher total specific energy per unit size reduction and lesser effective specific energy per unit size reduction compared to switchgrass. Data on minimized total specific energy with corresponding particle spectra will be useful for preparing feed material with a knife mill for subsequent grinding with finer size reduction devices.

09 BIOMASS FUELS↗

SPLAT II: An Aircraft Compatible, Ultra-Sensitive, High Precision Instrument for In-Situ Characterization of the Size and Composition of Fine and Ultrafine Particles

The properties of aerosols depend on the size and internal compositions of the individual particles. The vast majority of atmospheric aerosols are smaller than 200 nm, yet the single particle mass spectrometers, the only instruments that can characterize the size and internal compositions of individual particles, typically detect these small particles with extremely low efficiencies. In this paper we describe a new instrument called SPLAT II that provides unparalleled sensitivity to small particles, detecting 100% of particles that are larger than 125 nm and 40% of 100 nm particles. This instrument also brings an increase by a factor of 10 in temporal resolution, sizing up to 500 particles per second and characterizing the composition of up to 100 of them. SPLAT II uses a two-laser, two-step process to evaporate the particles and generate ions, producing high quality, reproducible mass spectra of the refractive and non-refractive aerosol fractions to yield the complete compositions of individual particles. The instrument control board provides for size dependent delays for lasers’ triggers to eliminate a size dependent hit rate. The mass spectra are recorded with 14-bit vertical resolution and analyzed using custom software packages. The instrument’s high sizing resolution and sensitivity makes it possible to combine it with the differential mobility analyzer(s) and measure particle size, composition, density, dynamic shape factor, hygroscopicity, and fractal dimension.

47 OTHER INSTRUMENTATION↗

Extending the Capabilities of Single Particle Mass Spectrometry: I. Measurements of Aerosol Number Concentration, Size Distribution, and Asphericity

Single particle mass spectrometers have traditionally been deployed to measure the size and composition of individual particles at relatively slow sampling rates that are determined by the rate at which the ionization lasers can fire and/or mass spectra can be recorded. To take advantage of the fact that under most conditions SPLAT can detect and size particles at much higher rates we developed a dual data acquisition mode, in which particle number concentrations, size distributions, and asphericity parameters are measured at a particle concentration determined rate, all the while the instrument generates and records mass-spectra at an operator set rate. We show that with this approach particle number concentration and asphericity parameters are measured with 1 sec resolution and particle vacuum aerodynamic size distributions are measured with 10 sec to 60 sec resolution. SPLAT measured particle number concentrations are in perfect agreement with the PCASP. Particle asphericity parameters are based on measured particle beam divergence. We illustrate the effect that high particle concentrations can have on the measured size distributions and develop a method to remove these effects and correct the size distributions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tandem Differential Mobility Analyzer/Aerodynamic Particle Sizer (APS) Handbook

The tandem differential mobility analyzer (TDMA) is a single instrument that cycles through a series of complementary measurements of the physical properties of size-resolved submicron particles. In 2008, the TDMA was augmented through the addition of an aerodynamic particle sizer (APS), which extends the upper limit of the measured size distribution into the supermicron range. These two instruments are operated in parallel, but because they are controlled by a common computer and because the size distributions measured by the two are integrated in the produced datastreams, they are described together here. Throughout the day, the TDMA sequentially measures submicron aerosol size distributions and size-resolved hygroscopic growth distributions. More specifically, the instrument is operated as a scanning DMA to measure size distributions and as a TDMA to measure size-resolved hygroscopicity. A typical measurement sequence requires roughly 45 minutes. Each morning additional measurements are made of the relative humidity (RH) dependent hygroscopicity and temperature-dependent volatility of size-resolved particles. When the outside temperature and RH are within acceptable ranges, the hydration state of size-resolved particles is also characterized. The measured aerosol distributions complement the array of aerosol instruments in the Aerosol Observing System (AOS) and provide additional details of the light-scattering and cloud-nucleating characteristics of the aerosol.

47 OTHER INSTRUMENTATION↗

Classification of Particle Shapes from Lidar Depolarization Ratios in Convective Ice Clouds Compared to in situ Observations During CRYSTAL-FACE

This manuscript describes a method to class@ cirrus cloud ice particle shape using lidar depolarization measurements as a basis for segregating different particle shape regimes. Measurements from the ER-2 Cloud Physics Lidar (CPL) system during CRYSTAL-FACE provide the basis for this work. While the CPL onboard the ER-2 aircraft was providing remote sensing measurements of cirrus clouds, the Cloud Particle Imager (CPI) onboard the WB-57 aircraft was flying inside those same clouds to sample particle sizes. The results of classifying particle shapes using the CPL data are compared to the in situ measurements made using the CPI , and there is found to be good agreement between the particle shape inferred from the CPL data and that actually measured by the CPI. If proven practical, application of this technique to spaceborne observations could lead to large-scale classification of cirrus cloud particle shapes.

Noel, Vincent↗

Particle Loss in a Scanning Mobility Particle Analyzer Sampling Extension Tube

Deposition of particles in sampling lines may occur due to inertial, electrostatic, or diffusional forces among others. Very small particles such as those in the nanoscale1, are not susceptible to losses from inertial deposition.2 Electrical effects are reportedly controlled by the use of conductive tubing.2 Particle losses from Brownian diffusion affect both particle size distribution and number concentration. Selectively removing the smallest particles has the effect of increasing the statistical measures of particle size; mean, median, geometric mean, mode, while decreasing number concentration and geometric standard deviation. These losses if quantified can be used to interpret or correct the data.3,4 Sample loss from either a rigid graphitic or flexible Tygon tube attached to a Scanning Mobility Particle Sizer inlet was investigated as part of the routine sampling process at the Center for Nanophase Materials Sciences. Mean concentrations and particle size parameters determined from samples collected with and without sample inlet extensions of both types were compared. No losses or changes in aerosol size distribution parameters that required correction were found for either material at lengths of ~0.7m.

47 OTHER INSTRUMENTATION↗

'Blueprint' your pulverizer for improved performance

Pulverizer throughput is determined by the coal fineness desired for a given coal. However, compromising on coal fineness when your pulverizer isn't up to scratch can increase NOx and cause many furnace problems. Your least costly option for increasing pulverizer capacity is to pay careful attention to key dimensions and critical tolerances during your next overhaul. 11 figs.

01 COAL, LIGNITE, AND PEAT↗

Application of Derrick Corporation's stack sizer technology for slimes reduction in 6 inch clean coal hydrocyclone circuits

The article discusses the successful introduction of Derrick Corporation's Stack Sizer technology for removing minus 200 mesh slimes from 6-inch coal hydrocyclone underflow prior to froth flotation or dewatering by screen bowl centrifuges. In 2006, the James River Coal Company selected the Stack Sizer fitted with Derrick 150 micron and 100 micron urethane screen panels for removal of the minus 100 mesh high ash clay fraction from the clean coal spiral product circuits. After this application proved successful, Derrick Corporation introduced new 75 micron urethane screen panels for use on the Stack Sizer. Evaluation of feed slurry to flotation cells and screen bowl centrifuges showed significant amounts of minus 75 micron that could potentially be removed by efficient screening technology. Removal of the minus 75 micron fraction was sought to reduce ash and moisture content of the final clean coal product. Full-scale lab tests confirmed that the Stack Sizer fitted with Derrick 75 micron urethane screen panels consistently reduced the minus 75 micron percentage in coal slurry from 6-inch clean coal hydrocyclone underflow that is approximately 15 to 20% solid by-weight and 30 to 60% minus 75 micron to a clean coal fraction that is approximately 13 to 16% minus 75 micron. As a result total ash is reduced from approximately 36 to 38% in the hydrocyclone underflow to 14 to 16% in the oversize product fraction form the Stack Sizers. 1 fig., 2 tabs., 5 photos.

01 COAL, LIGNITE, AND PEAT↗

Quantifying the effect of CO 2 gasification on pulverized coal char oxy-fuel combustion

Previous research has provided strong evidence that CO 2 and H 2 O gasification reactions can provide non-negligible contributions to the consumption rates of pulverized coal (pc) char during combustion, particularly in oxy-fuel environments. Fully quantifying the contribution of these gasification reactions has proven to be difficult, due to the dearth of knowledge of gasification rates at the elevated particle temperatures associated with typical pc char combustion processes, as well as the complex interaction of oxidation and gasification reactions. Gasification reactions tend to become more important at higher char particle temperatures (because of their high activation energy) and they tend to reduce pc oxidation due to their endothermicity (i.e. cooling effect). The work reported here attempts to quantify the influence of the gasification reaction of CO 2 in a rigorous manner by combining experimental measurements of the particle temperatures and consumption rates of size-classified pc char particles in tailored oxy-fuel environments with simulations from a detailed reacting porous particle model. The results demonstrate that a specific gasification reaction rate relative to the oxidation rate (within an accuracy of approximately +/- 20% of the pre-exponential value), is consistent with the experimentally measured char particle temperatures and burnout rates in oxy-fuel combustion environments. Conversely, the results also show, in agreement with past calculations, that it is extremely difficult to construct a set of kinetics that does not substantially overpredict particle temperature increase in strongly oxygen-enriched N2 environments. This latter result is believed to result from deficiencies in standard oxidation mechanisms that fail to account for falloff in char oxidation rates at high temperatures.

42 ENGINEERING↗

Comparative studies of grain size separates of 60009

Five samples from 60009, the lower half of a double drive tube, were analyzed via grain-size methods, with particle types classified and counted in the coarser grain sizes. Studies were undertaken of particle types and distributions by petrographic methods, of magnetic fractions, of the size splits and magnetic splits as analyzed by ferromagnetic resonance (FMR) techniques, of maturity (based on agglutinate content, FMR index Is/FeO, mean size of sub-cm material, magnetic fraction), of possible reworking or mixing in situ, and of depositional history. Maturity indices are in substantial agreement for all of the five samples. Strong positive correlation of percent agglutinates and percent bedrock-derived lithic fragments, combined with negative correlation of those components with percent single crystal plagioclase, argue against in situ reworking of the same soil.

Mckay, D. S.↗

Pronounced Size Dependence in Structure and Morphology of Gas-Phase Produced, Partially Oxidized Cobalt Nanoparticles under Catalytic Reaction Conditions

It is generally accepted that optimal particle sizes are key for efficient nanocatalysis. Much less attention is paid to the role of morphology and atomic arrangement during catalytic reactions. Here we unravel the structural, stoichiometric, and morphological evolution of gas-phase produced cobalt nanoparticles in a broad size range. Particles with diameters between 1.4 nm and 22nm generated in cluster sources are size selected and deposited on amorphous alumina (Al2O3) and ultrananocrystalline diamond (UNCD) films. A combination of different techniques is employed to monitor particle properties at the stages of production, exposure to ambient conditions, and catalytic reaction, in this case the oxidative dehydrogenation of cyclohexane at elevated temperatures. A pronounced size dependence is found, naturally classifying the particles into three size regimes. While small and intermediate clusters essentially retain their compact morphology, large particles transform into hollow spheres due to the nanoscale Kirkendall effect. Depending on the substrate an isotropic (Al2O3) or anisotropic (UNCD) Kirkendall effect is observed. The latter results in dramatic lateral size changes. Our results shed light on the interplay between chemical reactions and the catalyst's structure and provide an approach to tailor the cobalt oxide phase composition required for specific catalytic schemes.

cluster source↗

A cost-effective differential mobility analyzer (cDMA) for multiple DMA column applications

In aerosol research and applications, a differential mobility analyzer (DMA) is now considered the standard tool for sizing and classifying monodisperse particles in the sub-micrometer and nanometer size ranges. However, DMA application at the pilot or industrial production scale remains infeasible because of the low mass throughput. A simple way to scale up DMA operation is to use multiple DMA columns. The manufacture and maintenance costs of existing DMAs, however, limit such a scale-up. A cost-effective DMA column (named cDMA) has thus been developed in this work to address the above issue. To reduce its manufacturing cost, the prototype was constructed using parts requiring little machining. The cDMA column was also designed for easy maintenance and easy variation of the classification length for any application-specified size range. In this study, prototypes with two particle classification lengths, 1.75 and 4.50 cm, were constructed and their performance was experimentally evaluated at sheath-to-aerosol flowrate ratios of 5:1, 10:1, and 15:1 via the tandem DMA (TDMA) technique. It was concluded that both prototype cDMAs, operated at a sheath/aerosol flowrate ratio less than 15:1 and with a polydisperse aerosol flowrate of 1.0 lpm, achieved sizing resolution comparable to that offered by Nano-DMA. The longer cDMA had comparable transmission efficiency to that of Nano-DMA, and the shorter cDMA exceeded the performance of Nano-DMA. Hence, the cDMA with the shorter (1.75 cm) classification length is better suited for the characterization of macromolecular samples.

54 ENVIRONMENTAL SCIENCES↗

Apparatus for handling micron size range particulate material

An apparatus for handling, transporting, or size classifying comminuted material was described in detail. Electrostatic acceleration techniques for classifying particles as to size in the particle range from 0.1 to about 100 microns diameter were employed.

Friichtenicht, J. F.↗