Search NASA⌕ Search

SEARCH · Search NASA

Results for “PDMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dynamics of PDMS- g -PDMS Bottlebrush Polymers by Broadband Dielectric Spectroscopy

Poly(dimethylsiloxane) (PDMS)-based bottlebrush polymers, PDMS-g-PDMS, have been synthesized by anionic polymerization in combination with a condensation-based grafting reaction. Bottlebrush polymers show intriguing features, e.g., extremely low viscosities. Hereby, studies of their dynamics are rare. Therefore, we focus on the segmental relaxation by broadband dielectric spectroscopy. An increasing cross-sectional radius proportional to the increasing side chain length has been observed by small-angle neutron scattering over three samples. Here, a comparison of the segmental relaxation times of the bottlebrushes with the respective linear chains reveals slower dynamics in the former. For longer chains, this effect vanishes.

36 MATERIALS SCIENCE↗

Aging of UV curable PDMS developed for large-scale, high viscosity stereolithography

Polydimethylsiloxane (PDMS) elastomers are silicone rubbers that find widespread application in both academic and industrial settings. This study investigates the use of photosensitive platinum catalysts for UV-activated hydrosilylation of PDMS, which enables the additive manufacturing of PDMS objects through techniques such as stereolithography. Specifically, this study focuses on understanding the aging behavior of Pt-catalyzed, UV-curable PDMS samples, including their mechanical behavior under thermal and UV-accelerated aging conditions. The results show that the Pt-catalyzed, UV-curable PDMS introduced in this research is ‘under-cured’ after being printed and will slowly evolve over time resulting in increased stiffness and decreased elongation, likely due to the formation of additional crosslinks. FTIR spectroscopy indicates that no new chemical bonds or functional groups are generated through the aging process, suggesting that no thermal degradation or polymer chain scissions occur in the polymer matrix. Overall, this PDMS formulation exhibits greater mechanical strength and significantly less reduction in strength with aging, compared with the commonly used, UV-curable thiol-ene PDMS.

36 MATERIALS SCIENCE↗

Less Is More: Oligomer Extraction and Hydrothermal Annealing Increase PDMS Adhesion Forces for Materials Studies and for Biology-Focused Microfluidic Applications

Cues in the micro-environment are key determinants in the emergence of complex cellular morphologies and functions. Primary among these is the presence of neighboring cells that form networks. For high-resolution analysis, it is crucial to develop micro-environments that permit exquisite control of network formation. This is especially true in cell science, tissue engineering, and clinical biology. We introduce a new approach for assembling polydimethylsiloxane (PDMS)-based microfluidic environments that enhances cell network formation and analyses. We report that the combined processes of PDMS solvent-extraction and hydrothermal annealing create unique conditions that produce high-strength bonds between solvent-extracted PDMS (E-PDMS) and glass—properties not associated with conventional PDMS. Extraction followed by hydrothermal annealing removes unbound oligomers, promotes polymer cross-linking, facilitates covalent bond formation with glass, and retains the highest biocompatibility. Herein, our extraction protocol accelerates oligomer removal from 5 to 2 days. Resulting microfluidic platforms are uniquely suited for cell-network studies owing to high adhesion forces, effectively corralling cellular extensions and eliminating harmful oligomers. We demonstrate the simple, simultaneous actuation of multiple microfluidic domains for invoking ATP- and glutamate-induced Ca 2+ signaling in glial-cell networks. These E-PDMS modifications and flow manipulations further enable microfluidic technologies for cell-signaling and network studies as well as novel applications.

36 MATERIALS SCIENCE↗

Frank–Kasper Phases Identified in PDMS- b -PTFEA Copolymers with High Conformational Asymmetry

In the search for the formation of Frank-Kasper phases from diblock copolymer self-assembly, a series of compositionally asymmetric poly(dimethylsiloxane)- b -poly(2,2,2-triflouroethyl acrylate)s (PDMS- b -PTFEAs) are synthesized to produce PDMS-rich phases with PDMS volume fractions ( f PDMS ) ranging from 0.746 to 0.869. As determined by small-angle X-ray scattering analysis, the Frank-Kasper sigma and C14 phases are identified at f PDMS = 0.796 and 0.851, respectively, plausibly due to high conformational asymmetry (ϵ ≈ 2.20) between the two blocks. Intriguingly, the σ phase develops during heating from a short-range liquid-like packing (LLP) state, whereas the C14 phase is achieved at room temperature, which are both followed by a disordering at higher temperatures. Finally, based on thermal experiments from a super cooled disordered state, the findings further provide compelling evidence of an LLP-hexagonally packed cylinder-σ transition and a direct pathway to the C14 phase during heating from an LLP state.

42 ENGINEERING↗

Dynamics of amphiphilic PEG–PDMS–PEG triblock copolymer assemblies

Here, the size and stability of micelles and vesicles determine the uptake capacity of guest molecules, thereby influencing potential applications in drug/gene delivery, bioreactors, and templates for nanoparticle synthesis. Polyethylene glycol (PEG) and polydimethylsiloxane (PDMS) are commonly used in these applications. We discovered that PEG-PDMS-PEG triblock copolymers can assemble into micelles and vesicles, making them valuable for dynamic studies to derive the bending elasticity, $κ_η$, which governs the stability these objects. We analyzed the structure using cryogenic transmission electron microscopy and small-angle neutron scattering. We investigated the dynamics through dynamic light scattering and neutron spin echo spectroscopy. By varying the number of repeating units in the hydrophilic block, we created micellar (PEG 28 -PDMS 15 -PEG 28 ) and vesicular systems (PEG 14 -PDMS 15 -PEG 14 ). For the vesicle, membrane rigidity was determined from experiments to be $κ_η$ =(16 ± 2) $k_BT$, where $k_BT$ is the thermal energy ($k_B$ Boltzmann’s constant and T is the temperature). According to Zilman and Granek's concept, membrane rigidity reflects height-height fluctuations within the membrane layer. Compared to polymers at the oil-water interface of a microemulsion, the membrane rigidity in polymersomes is over an order of magnitude higher, indicating significantly enhanced stability. This value closely aligns with that of liposomes, suggesting similar stability between polymersomes and liposomes.

Gupta, Sudipta [Louisiana State Univ., Baton Rouge↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

PDMS ‐silica composite gas separation membranes by direct ink writing

Abstract Polydimethylsiloxane (PDMS)‐based membranes containing amine‐functionalized and unfunctionalized silica particles were fabricated via direct ink writing for CO 2 /N 2 gas separation. The printability of the inks was evaluated by rheological measurements, while spectroscopy, microscopy, thermal measurements, and mechanical testing were employed to characterize the printed membranes. The surface morphology of the membranes revealed the absence of voids, demonstrating their suitability for gas separation. The printed membranes also exhibited desirable thermal and mechanical properties (i.e., thermal degradation temperature of 518 °C and tensile strength as high as 1.178 MPa with 529% elongation). The PDMS‐based membranes generally displayed high permeability for CO 2 but slightly low selectivity for the CO 2 /N 2 gas pair. The best‐combined permeability‐selectivity performance of 8794 barrer and selectivity of 11.64 was demonstrated by the printed PDMS membrane containing no SiO 2 fillers. The inclusion of unfunctionalized SiO 2 particles generally increased the membrane's gas permeability but compromised the selectivity. In contrast, membranes with amine‐functionalized silica showed improved selectivity compared to membranes containing unfunctionalized silica. Overall, the performance and characteristics offered by the PDMS/silica composite membranes demonstrated the potential of 3D printing as an economical and sustainable fabrication approach to developing materials for carbon capture applications.

Gutierrez, Dianne B.↗

Design and Fabrication of a PDMS Microchip Based Immunoassay

In this paper, we describe the design and fabrication process of a polydimethylsiloxane (PDMS) microchip for on-chip multiplex immunoassay application. The microchip consists of a PDMS microfluidic channel layer and a micro pneumatic valve control layer. By selectively pressurizing the pneumatic microvalves, immuno reagents were controlled to flow and react in certain fluidic channel sites. Cross contamination was prevented by tightly closed valves. Our design was proposed to utilize PDMS micro channel surface as the solid phase immunoassay substrate and simultaneously detect four targets antigens on chip. Experiment result shows that 20psi valve pressure is sufficient to tightly close a 200µm wide micro channel with flow rate up to 20µl/min.

60 APPLIED LIFE SCIENCES↗

IR Imaging of PDMS Degradation Thin Films on Metal Surfaces

The degradation of poly[dimethyl siloxane] (PDMS) fluids at metal surfaces can produce insulative PDMS films (also known as SiCO films) that lead to high contact resistance events impacting the performance of electrical contacts in PDMS fluid-filled environmental sensing devices(ESDs). To determine the extent of SiCO film formation on metal contact surfaces due to different exposure and aging conditions it is necessary to develop new characterization methods that allow rapid and non-destructive measurement of the location, thickness and quality of the SiCO degradation films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis of VACNFs on Aluminum Foil and Their Transfer to PDMS while Maintaining Alignment and Impalefection Functionality

Vertically aligned carbon nanofibers (VACNFs) are synthesized on 3003 aluminum substrates by direct current plasma enhanced chemical vapor deposition. Chemically synthesized nickel nanoparticles were used as the catalyst for growth. The silicon containing coating (SiNx) typically produced when VACNFs are grown on silicon was produced by adding silicon microparticles prior to growth. The fiber array was transferred to PDMS by spin casting a layer on the grown substrates, curing the PDMS, and etching away the aluminum in KOH. Energy dispersive x-ray spectroscopy, scanning electron microscopy, and fluorescence microscopy data are provided. The free standing array in PDMS was then loaded with pVENUS-C1 plasmid and human brain microcapillary endothelial cells (HCMECHBMEC)/d3 cells were successfully impalefected with the plasmid.

Railsback, Justin↗

Various Low-Symmetry Phases in High- χ and Conformationally Asymmetric PDMS- b -PTFEA Copolymers

Since the discovery of the Frank–Kasper (FK) phase a decade ago, single-component block copolymer systems have offered unique opportunities to explore the structural and phase-transition properties of topologically close-packed FK phases composed of point-particle motifs. Here, we present the formation of complex low-symmetry phases and their thermodynamic stability using high-χ and high-ε linear diblock copolymers, where χ and ε are the Flory–Huggins interaction parameter and conformational asymmetry between the two blocks, respectively. In this work, a series of polydimethylsiloxane-b-poly(2,2,2-trifluoroethyl acrylate) (PDMS-b-PTFEA) copolymers are prepared by tuning the volume fraction ($f_{\text{PTFEA}}$) of a minor PTFEA block. The packing structures of PDMS-b-PTFEAs are mapped in the space of temperature versus $f_{\text{PTFEA}}$ using X-ray scattering measurements. In addition to the packing structures reported earlier, we identify another A15 phase at higher $f_{\text{PTFEA}}$ close to a hexagonally packed cylinder (HEX) phase and establish the phase sequence of HEX–A15–σ–C14–BCC with decreasing $f_{\text{PTFEA}}$. Theoretical calculation of relative free-energy densities confirms the experimental phase sequence of the composition-dependent sphere-packing structures. Interestingly, the domain sizes of three-dimensional (3D) sphere-packing structures are nearly temperature-invariant compared to that of a two-dimensional HEX structure, and we attribute this dimensional stability to the strong enthalpic effects in the formation of 3D packing structures and the geometrical characteristics of spherical domains. Our results demonstrate that the interaction parameter χ, together with the known role of conformational asymmetry ε, serves as the primary thermodynamic parameter for selecting and stabilizing various low-symmetry packing structures in sphere-forming linear diblock copolymer systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microfabrication of plastic-PDMS microfluidic devices using polyimide release layer and selective adhesive bonding

In this study, we present an improved method to bond poly(dimethylsiloxane) (PDMS) with polyimide (PI) to develop flexible substrate microfluidic devices. The PI film was separately fabricated on a silicon wafer by spin coating followed by thermal treatment to avoid surface unevenness of the flexible substrate. In this way, we could also integrate flexible substrate into standard micro-electromechanical systems (MEMS) fabrication. Meanwhile, the adhesive epoxy was selectively transferred to the PDMS microfluidic device by a stamp-and-stick method to avoid epoxy clogging the microfluidic channels. To spread out the epoxy evenly on the transferring substrate, we used superhydrophilic vanadium oxide film coated glass as the transferring substrate. After the bonding process, the flexible substrate could easily be peeled off from the rigid substrate. Contact angle measurement was used to characterize the hydrophicity of the vanadium oxide film. X-ray photoelectron spectroscopy analysis was conducted to study the surface of the epoxy. We further evaluated the bonding quality by peeling tests, which showed a maximum bonding strength of 100 kPa. By injecting with black ink, the plastic microfluidic device was confirmed to be well bonded with no leakage for a day under 1 atm. Finally, this proposed versatile method could bond the microfluidic device and plastic substrate together and be applied in the fabrication of some biosensors and lab-on-a-chip systems.

42 ENGINEERING↗

Ultrafast shock compression of PDMS-based polymers

The shock response of polymers is important for a number of commercial and defense–related applications, but it is difficult to obtain empirical shock response data over the wide range of preparations and aging conditions typically found in such applications. Ultrafast compression is useful to characterize polymer shock response over a wide range of polymer initial conditions due to the high throughput of this method. To establish greater confidence in ultrafast compression experiments and to characterize the detailed shock response of several variations in a single base polymer, the results of sub–nanosecond shock compression experiments in ~5 μm thick layers of the polydimethylsiloxane (PDMS)–based elastomeric rubbers Sylgard–184, SE1700, and an unfilled, end–linked model PDMS network are presented. The results of conventional ultrafast shock etalon measurements to time–of–flight measurements for similar thickness layers of irradiated and unirradiated SE1700 are compared. Here, good agreement between the shock response measured by these two ultrafast shock methods, as well as consistency between ultrafast data and long time scale gas gun data is found.

36 MATERIALS SCIENCE↗