Lens-array PDV Probe Using a Pyramid Prism
A bug eye probe is shown using a pyramid prism, and its advantages and disadvantages are enumerated. Also shown is abug eye imaging probe, with its advantages and disadvantages enumerated.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A bug eye probe is shown using a pyramid prism, and its advantages and disadvantages are enumerated. Also shown is abug eye imaging probe, with its advantages and disadvantages enumerated.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract Not Provided
Presentation discussed improved performance of Argus NX3b fisheye probe; new potentials afforded by multicore fiber; back-reflections at the lens-fiber interface in Argus probes; and a proposal for a new PDV architecture.
Photonic Doppler Velocimetry (PDV) is a diagnostic commonly used in shock physics and dynamic compression experiments to reliably get velocity information from experiments. In PDV systems, a common method of reducing experimental cost is to use time and frequency multiplexing to increase the number of PDV probes. With time multiplexing, interference between probes is a frequent problem. In this report, we look at using a high-speed optical switch to reduce this interference, including measuring the amount of interference generated to determine if it has the potential to affect experiments and integrating a time multiplexing system into an experiment. We find that, when applied to PDV systems, there is approximately (-23.4 ± 0.9) dB of interference measured in the short time Fourier transform between switch inputs. When an optical switch based time multiplexing system was integrated into a dynamic compression experiment, the system was able to successfully combine the signals from four different PDV probes onto a single optical cable without unacceptable levels of interference in the spectrogram. An optical switch based time multiplexing system appears to be a promising method for reducing the cost of fielding larger numbers of PDV probes in an experiment.
No abstract prepared.
Material scientists have developed computational modeling to predict the dynamic response of materials undergoing stress, but there is still a need to make precision measurements of surfaces undergoing shock compression. Miniature photonic Doppler velocimetry (PDV) probes have been developed to measure the velocity distribution from a moving surface traveling tens of kilometers per second. These probes use hundreds of optical fibers imaged by optical relays onto different regions of this moving surface. While previous work examined large surface areas, we have now developed a PDV microscope that can interrogate 37 different spots within a field of view of <1 mm, with a standoff distance of 17 mm, to analyze the motion differences across grain boundaries of the material undergoing dynamic stress. Each PDV fiber interrogates a 10 μm spot size on the moving surface. A separate imaging system using a coherent bundle records the location of the PDV spots relative to the grain boundaries prior to the dynamic event. Designing the mounting structures for the lenses, fibers, and coherent bundle was a challenge. To minimize back reflections, the fibers are index matched onto the first relay lens, which is made of fused silica. The PDV fibers are aligned normal to the moving surface. The imaging probe views the surface at an 18° angle. The coherent bundle is tilted 11° to its optical relay. All components are assembled into a single probe head assembly. The coherent bundle is removed from the probe head to be used for the next dynamic event. Alignment issues will also be discussed.
Windowed PDV probes are used as a time of arrival diagnostic where conventional PDV measurements cannot be made with accuracy i.e., measurements where the surface measured is bare HE or the surface measured does not provide quality optical return for PDV directly. Often hydro experiments require that these diagnostics be minimally invasive, so their installation does not negatively impact the device performance or the overall experiments goals. In this report we build 3 mm diameter windowed probes and show that they give an error that is still within the error of piezo pins.
This was a collaborative shot with AWE investigators Paul Willis-Patel, David Bell, Seth Grant, David Tarr, and James Richley. The shot was assembled in Los Alamos, after which David Bell set up the probe holder and finalized the alignment. The probe holder location and configuration was modified from previous years to make room for the laser illuminated visible imaging diagnostic. The LANL pRad PDV team was Dale Tupa, Amy Tainter, and Patrick Medina. This shot had three PDV probes: one aimed at the center, one aimed at a feature, one aimed at the reverse side of the shot. The shot also had 9 points of a spectroscopy diagnostic. The pRad team helped set up and field the spectroscopy, but did not help with any data analysis. (The support documentation for the PDV results includes a timing map for the spectroscopy.) Please direct questions on the velocimetry to Dale Tupa or Amy Tainter. The shot radiographs were classified, but the data from the optical diagnostics are not.
Graded density impactors (GDIs) are utilized to dynamically compress materials to extreme conditions. Two modifications to a previously developed Mg-Cu-W GDI are made in this work before using it in a dynamic compression experiment: Mg is replaced with Al and a Ta disk is glued to the back. The Mg phase is replaced by Al because FCC Al remains solid to higher pressure along its Hugoniot compared to Mg. The addition of the Ta disk creates a constant particle velocity regime and facilitates a definition of peak pressure states. Microstructure analysis, profilometry, and ultrasonic C-scans of the Al-Cu-W GDI all confirm excellent uniformity. We evaluated signal variation in the radial direction of a dynamically compressed Al-LiF bilayer target to evaluate the contribution of spatial nonuniformity to errors. Velocity traces from five photon Doppler velocimetry (PDV) probes located at different radial distances from the center of the target varied at most by 1.1% with a root mean square of 0.3% during the compression ramp, demonstrating low PDV measurement error over a relatively large experimental area. The experimental PDV data additionally agrees well with 1D simulations that use inputs from predictive characterization models developed for the material properties resulting from tape casting, laminating, and powder consolidation processes. Low measurement error during quasi-isentropic compression, leading to better precision, promises a robust platform to reach extreme compression and low-temperature recovery states and facilitates discovery via synthesis, quenching, and preservation of new high-pressure phases.
The Jack Rabbit Pretest (PT) 2021E PT7 experiment was fired on April 3, 2008 at the Contained Firing Facility, Site 300, Lawrence Livermore National Laboratory. This experiment is part of an effort to determine the properties of LX-17 in a regime where corner-turning behavior and dead-zone formation are not well understood. Photonic Doppler Velocimetry (PDV) measured diagnostic plate velocities confirming the presence of a persistent LX-17 dead-zone formation and the resultant impulse gradient applied under the diagnostic plate. The Jack Rabbit Pretest 2021E PT7, 160 millimeter diameter experiment returned data on all eight PDV probes. The probes measured on the central axis and at 20, 30, 35, 45, 55, 65, 75 millimeters from the central axis. The experiment was shot at an ambient room temperature of 65 degrees Fahrenheit. The PDV earliest signal extinction was 50.7 microseconds at 45 millimeters. The latest PDV signal extinction time was 65.0 microseconds at 20 millimeters. The measured velocity ranged from meters per second to thousands of meters per second. First detonation wave induced jump-off was measured at 55 millimeters and at 15.2 microseconds. The PDV data provided an unambiguous indication of dead-zone formation and an impulse gradient applied to the diagnostic plate. The central axis had a last measured velocity of 1447 meters per second. At 65 millimeters the last measured velocity was 2360 meters per second. The low-to-high velocity ratio was 0.61. Velocity data was integrated to compute diagnostic plate cross section profiles. Velocity data was differentiated to compute a peak pressure under the diagnostic plate at the central axis of 49 kilobars at 23.3 microseconds. Substantial motion (>1 m/s) of the diagnostic plate over the dead-zone is followed by detonation region motion within approximately 4.6 microseconds.
The Jack Rabbit Pretest (PT) 2021E PT3 was fired on March 12, 2008 at the Contained Firing Facility, Site 300, Lawrence Livermore National Laboratory. This experiment is part of an effort to determine the properties of LX-17 in a regime where corner-turning behavior and dead-zone formation are not well understood. Photonic Doppler Velocimetry (PDV) measured diagnostic plate velocities confirming the presence of a persistent LX-17 dead-zone formation and the resultant impulse gradient applied under the diagnostic plate. The Jack Rabbit Pretest 2021E PT3, 120 millimeter diameter experiment returned data on all eight PDV probes. The probes measured on the central axis and at 10, 20, 25, 30, 35, 40, 50 millimeters from the central axis. The experiment was shot at an ambient room temperature of 65 degrees Fahrenheit. The earliest PDV signal extinction was 41.7 microseconds at 30 millimeters. The latest PDV signal extinction time was 65.0 microseconds at 10 millimeters. The measured velocity ranged from meters per second to thousands of meters per second. First detonation wave induced jump-off was measured at 40 millimeters at 10.9 microseconds. The PDV data provided an unambiguous indication of dead-zone formation and an impulse gradient applied to the diagnostic plate. The central axis had a last measured velocity of 1636 meters per second. At 40 millimeters the last measured velocity was 2056 meters per second. The low-to-high velocity ratio was 0.80. Velocity data was integrated to compute diagnostic plate cross section profiles. Velocity data was differentiated to compute a peak pressure under the diagnostic plate at the central axis of 64.6 kilobars at 15.7 microseconds. Substantial motion (>1 m/s) of the diagnostic plate over the dead-zone is followed by detonation region motion within approximately 2.2 microseconds.
The Jack Rabbit Pretest (PT) 2021E PT4 was fired on March 19, 2008 at the Contained Firing Facility, Site 300, Lawrence Livermore National Laboratory. This experiment is part of an effort to determine the properties of LX-17 in a regime where corner-turning behavior and dead-zone formation are not well understood. Photonic Doppler Velocimetry (PDV) measured diagnostic plate velocities confirming the presence of a persistent LX-17 dead-zone formation and the resultant impulse gradient applied under the diagnostic plate. The Jack Rabbit Pretest 2021E PT4, 120 millimeter diameter experiment returned data on all eight PDV probes. The probes measured on the central axis and at 10, 20, 25, 30, 35, 40, 50 millimeters from the central axis. The experiment was shot at an ambient room temperature of 64 degrees Fahrenheit. The earliest PDV signal extinction was 44.9 microseconds at 30 millimeters. The latest PDV signal extinction time was 69.5 microseconds at 10 millimeters. The measured velocity ranged from meters per second to thousands of meters per second. First detonation wave induced jump-off was measured at 50 millimeters at 13.3 microseconds. The PDV data provided an unambiguous indication of dead-zone formation and an impulse gradient applied to the diagnostic plate. The central axis had a last measured velocity of 1558 meters per second. At 40 millimeters the last measured velocity was 2019 meters per second. The low-to-high velocity ratio was 0.77. Velocity data was integrated to compute diagnostic plate cross section profiles. Velocity data was differentiated to compute a peak pressure under the diagnostic plate at the central axis of 98.6 kilobars at 15.0 microseconds. Substantial motion (>1 m/s) of the diagnostic plate over the dead-zone is followed by detonation region motion within approximately 0.7 microseconds.
The Jack Rabbit Pretest (PT) 2021E PT5 was fired on March 17, 2008 at the Contained Firing Facility, Site 300, Lawrence Livermore National Laboratory. This experiment is part of an effort to determine the properties of LX-17 in a regime where corner-turning behavior and dead-zone formation are not well understood. Photonic Doppler Velocimetry (PDV) measured diagnostic plate velocities confirming the presence of a persistent LX-17 dead-zone formation and the resultant impulse gradient applied under the diagnostic plate. The Jack Rabbit Pretest 2021E PT5, 160 millimeter diameter experiment returned data on all eight PDV probes. The probes measured on the central axis and at 20, 30, 35, 45, 55, 65, 75 millimeters from the central axis. The experiment was shot at an ambient room temperature of 65 degrees Fahrenheit. The earliest PDV signal extinction was 40.0 microseconds at 45 millimeters. The latest PDV signal extinction time was 64.9 microseconds at 20 millimeters. The measured velocity ranged from meters per second to thousands of meters per second. First detonation wave induced jump-off was measured at 55 millimeters at 12.8 microseconds. The PDV data provided an unambiguous indication of dead-zone formation and an impulse gradient applied to the diagnostic plate. The central axis had a last measured velocity of 1877 meters per second. At 65 millimeters the last measured velocity was 2277 meters per second. The low-to-high velocity ratio was 0.82. Velocity data was integrated to compute diagnostic plate cross section profiles. Velocity data was differentiated to compute a peak pressure under the diagnostic plate at the central axis of 78 kilobars at 11.9 and 21.2 microseconds. Substantial motion (>1 m/s) of the diagnostic plate over the dead-zone is followed by detonation region motion within approximately 4.1 microseconds.
The Jack Rabbit Pretest (PT) 2021E PT6 experiment was fired on April 1, 2008 at the Contained Firing Facility, Site 300, Lawrence Livermore National Laboratory. This experiment is part of an effort to determine the properties of LX-17 in a regime where corner-turning behavior and dead-zone formation are not well understood. Photonic Doppler Velocimetry (PDV) measured diagnostic plate velocities confirming the presence of a persistent LX-17 dead-zone formation and the resultant impulse gradient applied under the diagnostic plate. The Jack Rabbit Pretest 2021E PT6, 160 millimeter diameter experiment returned data on all eight PDV probes. The probes measured on the central axis and at 20, 30, 35, 45, 55, 65, 75 millimeters from the central axis. The experiment was shot at an ambient room temperature of 65 degrees Fahrenheit. The earliest PDV signal extinction was 54.2 microseconds at 30 millimeters. The latest PDV signal extinction time was 64.5 microseconds at the central axis. The measured velocity ranged from meters per second to thousands of meters per second. First detonation wave induced jump-off was measured at 55 millimeters at 14.1 microseconds. The PDV data provided an unambiguous indication of dead-zone formation and an impulse gradient applied to the diagnostic plate. The central axis had a last measured velocity of 1860 meters per second. At 55 millimeters the last measured velocity was 2408 meters per second. The low-to-high velocity ratio was 0.77. Velocity data was integrated to compute diagnostic plate cross section profiles. Velocity data was differentiated to compute a peak pressure under the diagnostic plate at the central axis of 227 kilobars at 20.1 microseconds, indicating a late time chemical reaction in the LX-17 dead-zone. Substantial motion (>1 m/s) of the diagnostic plate over the dead-zone is followed by detonation region motion within approximately 1.7 microseconds.
A series of 2 SPE5 sub-scale tests were performed to experimentally confirm that a booster system designed and evaluated in prior tests would properly initiate the PBXN-110 case charge fill. To conduct the experiments, a canister was designed to contain the nominally 50 mm diameter booster tube with an outer fill of approximately 150 mm diameter by 150 mm in length. The canisters were filled with PBXN-110 at NAWS-China Lake and shipped back to LLNL for testing in the High Explosives Applications Facility (HEAF). Piezoelectric crystal pins were placed on the outside of the booster tube before filling, and a series of piezoelectric crystal pins along with Photonic Doppler Velocimetry (PDV) probes were placed on the outer surface of the canister to measure the relative timing and magnitude of the detonation. The 2 piezoelectric crystal pins integral to the booster design were also utilized along with a series of either piezoelectric crystal pins or piezoelectric polymer pads on the top of the canister or outside case that utilized direct contact, gaps, or different thicknesses of RTV cushions to obtain time of arrival data to evaluate the response in preparation for the large-scale SPE5 test. To further quantify the margin of the booster operation, the 1st test (SPE5SS1) was functioned with both detonators and the 2nd test (SPE5SS2) was functioned with only 1 detonator. A full detonation of the material was observed in both experiments as observed by the pin timing and PDV signals. The piezoelectric pads were found to provide a greater measured signal magnitude during the testing with an RTV layer present, and the improved response is due to the larger measurement surface area of the pad. This report will detail the experiment design, canister assembly for filling, final assembly, experiment firing, presentation of the diagnostic results, and a discussion of the results.
The uniaxial strain dynamic densification behavior of cerium dioxide powders as a function of powder compact green density is investigated in this work. Cerium dioxide powders of two particle morphologies (rod-like and equiaxed) and two green densities (55% and 62.5% TMD) are shock compressed using the gas gun with specifically designed fixtures and their particle and shock wave velocities are measured using VISAR and multiple PDV probes. The obtained data describe the Hugoniot of the shocked cerium dioxide powders. Finally, the method used to produce this high fidelity Hugoniot data for cerium dioxide powders is discussed and preliminary data are shown.