Search NASA⌕ Search

SEARCH · Search NASA

Results for “PEEK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wide-angle X-ray scattering study of heat-treated PEEK and PEEK composite

Samples of poly(etheretherketone) (PEEK) neat resin and APC-2 carbon fiber composite were subjected to various heat treatments, and the effect of quenching and annealing treatments was studied by wide-angle X-ray scattering. It is found that high-temperature treatments may introduce disorder into neat resin and composite PEEK when followed by rapid cooling. The disorder is metastable and can revert to ordered state when the material is heated above its glass transition temperature and then cooled slowly. The disorder may result from residual thermal stresses.

Cebe, Peggy↗

Multiscale Modeling of PEEK Using Reactive Molecular Dynamics Modeling and Micromechanics

Polyether ether ketone (PEEK) is a high-performance, semi-crystalline thermoplastic that is used in a wide range of engineering applications, including some structural components of aircraft. The design of new PEEK-based materials requires a precise understanding of the multiscale structure and behavior of semi-crystalline PEEK. Molecular Dynamics (MD) modeling can efficiently predict bulk-level properties of single phase polymers, and micromechanics can be used to homogenize those phases based on the overall polymer microstructure. In this study, MD modeling was used to predict the mechanical properties of the amorphous and crystalline phases of PEEK. The hierarchical microstructure of PEEK, which combines the aforementioned phases, was modeled using a multiscale modeling approach facilitated by NASA's MSGMC. The bulk mechanical properties of semi-crystalline PEEK predicted using MD modeling and MSGMC agree well with vendor data, thus validating the multiscale modeling approach.

Pisani, William A.↗

Effects of Melt Processing on Evolution of Structure in PEEK

We report on the effects of melt processing temperature on structure formation in Poly(ether-ether-ketone), PEEK. Real time Small Angle X-ray Scattering, SAXS, and thermal analysis are used to follow the melting behavior after various stages of processing. Assignment of peaks to structural entities within the material, the relative perfection of the crystals, and the possibility of their reorganization, are all influenced by the melt processing history. With the advent of high intensity synchrotron sources of X-radiation, polymer scientists gain a research tool which, when used along with thermal analysis, provides additional structural information about the crystals during growth and subsequent melting. PEEK is an engineering thermoplastic polymer with a very high glass transition temperature (145 C) and crystal melting point (337 C). PEEK has been the subject of recent studies by X-ray scattering in which melt and cold crystallization were followed in real-time. X-ray scattering and thermal studies have been used to address the formation of dual endothermic response which has been variously ascribed to lamellar insertion, dual crystal populations, or melting followed by re-crystallization. Another important issue is whether all of the amorphous phase is located in interlamellar regions, or alternatively whether some is located in "pockets" away from the crystalline lamellar stacks. The interpretation of scattering from lamellar stacks varies depending upon whether such amorphous pockets are formed. Some groups believe all of the amorphous phase is interlamellar. This leads to selection of a smaller thickness for the crystals. Other groups suggest that most amorphous phase is not interlamellar, and this leads to the suggestion that the crystal thickness is larger than the amorphous layer within the stacks. To investigate these ideas, we used SAXS and Differential Scanning Calorimetry to compare results of single and dual stage melt crystallization of PEEK using a treatment scheme involving annealing/crystallization at T(sub a1) followed by annealing at T(sub a2) where either T(sub a1) < T(sub a2) or T(sub a1) > T(sub a2). We proposed a model to explain multiple melting endotherms in PPS, treated according to one or two-stage melt or cold crystallization. Key features of this model are that multiple endotherms: (1) are due to reorganization/recrystallization after cold crystallization; and, (2) are dominated by crystal morphology after melt crystallization at high T. In other words, multiple distinct crystal populations are formed by the latter treatment, leading to observation of multiple melting. PEEK 45OG pellets (ICI Americas) were the starting material for this study. Films were compression molded at 400 C, then quenched to ice water. Samples were heated to 375 C in a Mettler FP80 hot stage and held for three min. to erase crystal seeds before cooling them to T(sub a1) = 280 C . Samples were held at T(sub a2) for a period of time, then immediately heated to 360 C. In the second treatment samples were held at T(sub a1) = 31 C for different crystallization times t(sub c) then cooled to 295 C and held 15 min. In situ (SAXS) experiments were performed at the Brookhaven National Synchrotron Light Source with the sample located inside the Mettler hot stage. The system was equipped with a two-dimensional position sensitive detector. The sample to detector distance was 172.7 cm and the X-ray wavelength was 1.54 Angstroms. SAXS data were taken continuously during the isothermal periods and during the heating to 360 C at 5 C/min. Each SAXS scan was collected for 30 sec. Since the samples were isotropic, circular integration was used to increase the signal to noise ratio. After dual stage melt crystallization with T(sub a1) < T(sub a2) the lower melting endotherm arises from holding at T(sub a1). During cooling a broad distribution of crystals forms, and the low-melting tail is perfected during T(sub al). Heating to T(sub a2) melts these imperfect crystals and allows others with greater average long spacing to form in their place. After dual stage crystallization with T(sub a1) > T(sub a2), the amount of space remaining for additional growth at T(sub a2) depends upon the holding time at T(sub a1). The long period of crystals formed at T(sub a2) is smaller than that formed at T(sub a1) due to growth in a now-restricted geometry. Perfection of crystals is seen as an increase of the intensity of the population scattering at higher s, while the intensity of the population scattering at lower s stays constant. During heating from below to above the minor endotherm, we see rapid decrease of the intensity of the X-ray scattering corresponding to the population of crystals scattering in the shoulder. Another important observation is that after the sample is annealed at 295 C, the shoulder intensity is restored once again. The population scattering at higher s remains longer before it disappears in the sample treated to the second stage of melt crystallization, compared to the sample crystallized with a single stage. This could be interpreted as an effect of continued perfection of the less perfect population, which is also reflected in the increased melting temperature of the smaller endotherm as the holding time at 295 C increases. In the corresponding DSC scans we see a shift in the area and the peak temperature of the lower melting endotherm with an increase of the annealing time.

Georgiev, Georgi↗

Refractive Index of Polyaryletherketone (PEEK) at X- and W-Band

This report details refractive index measurements of polyaryletherketone (PEEK) thermoplastic between X-band (8 to 12 GHz) and W-band (75 to 110 GHz) frequencies. Scattering-parameter data are collected using both traditional waveguide and modified free-space techniques. The complex-valued refractive index is calculated using the standard Nicolson-Ross-Weir method. Results indicate that PEEK’s refractive index is n = 1.783 – 0.001i across X-band and n = 1.792 – 0.007i across W-band. Therefore, PEEK exhibits a moderate real refractive index component and low transmission loss. Coupled with its favorable mechanical and thermal properties, this makes PEEK an ideal material to inspect using NASA’s submillimeter radiofrequency-based technology.

Polyaryletherketone↗

On the structure of poly(etheretherketone) (PEEK)

Annealed, hot pressed, and melt-quenched PEEK specimens have been analyzed by wide-angle X-ray diffraction. The analysis suggests, in part, that structural studies based on the reported similarity between the structure of PEEK and that reported for poly(p-phenylene oxide) are valid and may be extended to a structure more in keeping with the chemical structure of the material.

Wakelyn, N. T.↗

Mechanical properties of alumina-PEEK unidirectional composite - Compression, shear, and tension

An Al2O3 (alumina)-fiber composite with high strain to failure was fabricated with a thermal plastic PEEK (poly-ether-ether-ketone). The Al2O3-PEEK composite shows a marked improvement over thermally setting composite in that it absorbs 150 percent more elastic-strain energy at 76 K than at room temperature. This increase in fracture toughness at low temperatures can provide improved fatigue performance for thermal isolation straps at low temperature. Other mechanical property results suggest improvements for applications where graphite-epoxy materials are presently being used at low temperatures and where light weight is not a critical issue.

Kriz, R. D.↗

Microwave Photoelasticity: A Resonant Wavelength Approach Applied to PEEK Polymer

Every nondestructive testing (NDT) technique has its unique set of advantages and limitations. Currently, the only existing noncontact NDT method capable of measuring sub-surface stresses, in optically opaque materials, at near-real-time speeds and over large areas is Microwave Photoelasticity (MP). This paper presents a new MP approach, which correlates changes in resonant wavelengths to changes in stress. In addition to a theoretical outline of the approach, the design and operation of an instrument capable of conducting these measurements is described. Finally, the technique is demonstrated by conducting measurements on polyetheretherketone, commonly known as PEEK, polymer. Between the W-Band frequencies of 105 to 115 GHz, PEEK’s stress-optic-coefficient was determined to be of 𝐶𝐶 = −0.20 ± 0.02 1/GPa.

Schemmel, Peter J.↗

Fatigue delamination behavior of PEEK thermoplastic composite laminates

The delamination resistance of graphite-reinforced PEEK composites was quantified by conducting static and cyclic edge delamination tests on (35n/-35n/0n/90n)s AS4/PEEK laminates, where n = 1, 2. The experimentally determined mechanical delamination onset strains were used to calculate the critical strain-energy release rate for delamination onset as a function of fatigue cycle. The delamination onset strains decreased dramatically with fatigue cycles and then began to level off to an endurance limit at 1 million cycles. Although the static interlaminar fracture toughness of the AS4/PEEK composite is much greater than the toughness of graphite epoxy composites, the delamination fatigue threshold, calculated from the cyclic strain endurance limit at 1 million cycles, was only slightly greater than the threshold for graphite epoxy composites. The contribution of residual thermal stresses to delamination in the AS4/PEEK is substantial due to the large temperature range between the manufacture and the room temperatures.

O'Brien, T. K.↗

Shear strains in a graphite-PEEK beam by moire interferometry with carrier fringes

A multispan quasi-isotropic graphite-PEEK beam exhibited dramatic shear strains in the interlaminar region between plies. Shear strains in the plies themselves varied in basic accord with fiber direction. Large anomalous shear strains developed near the center of the beam height, where shear stresses were large. High-sensitivity moire interferometry with 2400 lines/mm was used. A new technique of data extraction was developed, using carrier fringes to transform the pattern to one in which fringe slopes are proportional to derivatives of displacement. It enhanced detection and measurement of highly localized shear-strain gradients.

Post, Daniel↗

High temperature dielectric properties of Apical, Kapton, Peek, Teflon AF, and Upilex polymers

Reliable lightweight systems capable of providing electrical power at the magawatt level are a requirement for future manned space exploration missions. This can be achieved by the development of high temperature insulating materials which are not only capable of surviving the hostile space environment but can contribute to reducing the mass and weight of the heat rejection system. In this work, Apical, Upilex, Kapton, Teflon AF, and Peek polymers are characterized for AC and DC dielectric breakdown in air and in silicone oil at temperatures up to 250 C. The materials are also tested in terms of their dielectric constant and dissipation factor at high temperatures with an electrical stress of 60 Hz, 200 V/mil present. The effects of thermal aging on the properties of the films are determined after 15 hours of exposure to 200 and 250 C, each. The results obtained are discussed and conclusions are made concerning the suitability of these dielectrics for use in capacitors and cable insulations in high temperature environments.

Hammoud, A. N.↗

On the thermally-induced residual stresses in thick fiber-thermoplastic matrix (PEEK) cross-ply laminated plates

An analytical method for calculating thermally-induced residual stresses in laminated plates is applied to cross-ply PEEK laminates. We considered three cooling procedures: slow cooling (uniform temperature distribution); convective and radiative cooling; and rapid cooling by quenching (constant surface temperature). Some of the calculated stresses are of sufficient magnitude to effect failure properties such as matrix microcracking.

Hu, Shoufeng↗

X-Ray-Scattering Measurements Of Strain In PEEK

Internal stress relieved by heating above glass-transition temperature. Report describes wide-angle x-ray scattering and differential scanning calorimetry of specimens of poly(etheretherketone) having undergone various thermal treatments. Wide-angle x-ray scattering particularly useful in determining distances between atoms, crystallinity, and related microstructurally generated phenomena, as thermal expansion and strain. Calorimetric measurements aid interpretation of scattering measurements by enabling correlation with thermal effects.

Cebe, Peggy↗

Peeking through the picket fence - What astrophysical surprises may be present in the 100-200 A region?

In anticipation of more sensitive EUV and FUV spectroscopic instruments, spectra are simulated including interstellar absorption of solarlike, RS CVn, and flare stars as folded through the instrument parameters of the EUVE, Lyman/FUSE Phase A, and a desirable next-generation spectrometer. Even the relatively insensitive EUVE spectrometer is able to detect sufficient spectral lines from many active binary and dMe stars to determine their coronal-emission-measure distributions. The Lyman/FUSE or next-generation spectrometers are needed to study solar-type stars or flaring stars with high time resolution. The high throughput and effective area of a nex-generation spectrometer is needed for Doppler imaging studies, stellar wind and downflow measurements, and high time and spectral resolution of stellar flares.

Linsky, Jeffrey L.↗

MoS2-Filled PEEK Composite as a Self-Lubricating Material for Aerospace Applications

At BAM, several projects were conducted in the past years dealing with the tribological properties of friction couples at cryogenic temperature and in vacuum environment. Promising candidates for vacuum application are MoS2-filled PEEK/PTFE composites, which showed a friction coefficient as low as 0.03 in high vacuum. To complete the tribological profile of these composites, further tests were performed in ultra-high vacuum (UHV) at room temperature. In this paper, friction and stick slip behavior, as well as outgassing characteristics during the test are presented.

Theiler, Geraldine↗

First Peek of ASTRO-H Soft X-Ray Telescope (SXT) In-Orbit Performance

ASTRO-H (Hitomi) is a Japanese X-ray astrophysics satellite just launched in February, 2016, from Tanegashima, Japan by a JAXA's H-IIA launch vehicle. It has two Soft X-ray Telescopes (SXTs), among other instruments, that were developed by the NASA Goddard Space Flight Center in collaboration with ISAS/JAXA and Nagoya University. One is for an X-ray micro-calorimeter instrument (Soft X-ray Spectrometer, SXS) and the other for an X-ray CCD camera (Soft X-ray Imager, SXI), both covering the X-ray energy band up to 15 keV. The two SXTs were fully characterized at the 30-m X-ray beam line at ISAS/JAXA. The combined SXT+SXS system effective area is about 250 and 300 cm(exp 2) at 1 and 6 keV, respectively, although observations were performed with the gate valve at the dewar entrance closed, which blocks most of low energy X-rays and some of high energy ones. The angular resolution for SXS is 1.2 arcmin (Half Power Diameter, HPD). The combined SXT+SXI system effective area is about 370 and 350 cm (exp 2) at 1 and 6 keV, respectively. The angular resolution for SXI is 1.3 arcmin (HPD). The both SXTs have a field of view of about 16 arcmin (FWHM of their vignetting functions).The SXT+SXS field of view is limited to 3 x 3 arcmin by the SXS array size. In-flight data available to the SXT team was limited at the time of this conference and a point-like source data is not available for the SXT+SXS. Although due to lack of attitude information we were unable to reconstruct a point spread function of SXT+SXI, according to RXJ1856.5-3754 data, the SXT seems to be working as expected in terms of imaging capability. As for the overall effective area response for both SXT+SXS and SXT+SXI, consistent spectral model fitting parameters with the previous measurements were obtained for Crab and G21.5-0.9 data. On the other hand, their 2-10 keV fluxes differ by about 20% at this point. Calibration work is still under progress. The SXT is the latest version of the aluminum foil X-ray mirror, which is extremely light-weight and very low cost, yet produces large effective area over a wide energy-band. Its area-mass ratio is the largest, 16 cm(exp 2)/kg, among ASTRO-H, Chandra, and XMM-Newton mirrors. The aluminum foil mirror is a still compelling technology depending on the mission science goal.

X-rays↗