High efficiency PEM water electrolysis: enabled by advanced catalysts, membranes, and processes
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
A model for producing hydrogen via offshore wind electrolysis was developed and the levelized costs of both energy and hydrogen were calculated. Here, this model calculated the cost of hydrogen produced by offshore wind and showed that the levelized cost of energy for hydrogen production and transportation to shore could be lower than for electricity transmission from offshore wind farms, using real wind data from a particular location. Therefore, direct coupling of the electrolysis system with offshore wind turbine is more advantageous than transmitting electricity to shore and then producing hydrogen via traditional electrolysis; the cost of hydrogen from offshore wind electrolysis is estimated to be $\$2.09$/kg, vs $\$3.86$/kg from traditional electrolysis using wind power.
Proton exchange membrane (PEM) water electrolysis offers key advantages, including high current density, high efficiency, and compact system architecture for hydrogen production. However, its widespread implementation is limited by the scarcity and high cost of Ir-based anodic catalysts. Herein, we report an Ir-free electrocatalyst for the acidic oxygen evolution reaction (OER): tantalum oxide (TaO x )–coated molybdenum-doped RuO 2 (TaO x -MoRuO 2 ). The catalyst exhibits a low overpotential of 180 mV at 10 mA cm -2 and excellent durability, with a degradation rate of 0.034 mV h -1 over a 150-hour test at 50 mA cm -2 —surpassing other Ru-based catalysts evaluated under similar conditions. A PEM electrolyzer employing TaO x -MoRuO 2 as the anode maintained stable operation for 100 hours at 500 mA cm -2 . In conclusion, the TaO x coating layer suppresses Ru and Mo dissolution, thus enhancing their stability likely via interfacial electronic reconfiguration of Ru and Mo mediated by bridging oxygen atoms.
Polymer electrolyte membrane (PEM) water electrolysis is a promising technology to efficiently produce green hydrogen. Irregularities in membrane electrode assembly (MEA) component materials caused by manufacturing, processing, handling, or operation can lead to performance loss and failure. One example is the presence of pinholes in the membrane, which can cause increased gas transport (crossover) and lead to electrical shorting. This work investigates the effects of intentionally introduced pinholes with various sizes up to 350μm in diameter. The presence of the pinholes resulted in minimal impacts on the cell voltage (±30 mV at 4Acm -2 ). However, the pinholes significantly increased H 2 crossover, which decreased hydrogen production efficiency and increased the minimum current density for safe operation. The impacts of the pinhole on the H 2 crossover and efficiency are more severe for open pinhole features than tear-like pinhole features. In conclusion, this research demonstrates that even small pinholes cannot be disregarded from a safety, efficiency, and operating strategy perspective.
While the number of publications in the PEM water electrolysis community increases each year, no common ground concerning reference hardware (test cells and test bench) and testing protocols has been yet established. This would, however, be necessary for the comparability of experimental results. First attempts for such reference hardware and procedures have been made in the framework of the Task 30 Electrolysis within the Technology Collaboration Programme on Advanced Fuel Cells (AFC TCP) of the International Energy Agency (IEA). Since then, improvements of both the test hardware (test cell and components) as well as the measurement protocol were identified, and a revised methodology and key results based on a comprehensive measurement series have been obtained. A detailed protocol for testing commercial reference components with a reference laboratory test cell developed in-house by Fraunhofer ISE is presented. For evaluation of the protocol and the hardware, it was tested at three different institutions at the same time. Impedance spectroscopic and polarization data was acquired and analyzed. The obtained differences in performance were calculated to give the community an expectation window to compare own data to. Finally, the importance of a thorough temperature control and the conditioning phase are demonstrated.
It is widely understood that the durability and reliability of polymer electrolyte membrane (PEM) water electrolyzers are heavily dependent on feedwater purity, with cation contaminants that originate from incomplete water purification and balance of plant materials significantly harming electrolyzer performance. However, contamination remains a challenge and a common cause of failure at the stack level, indicating the need for strategies to recover the performance of contaminated cells. In this study, we investigate the effects of temperature on the uptake, electrochemical impacts, and removal of contaminant calcium and iron cations. Lower operating temperatures increase the sensitivity of the cell performance to contaminant cations, while also decreasing cation uptake and promoting contaminant removal. Computational charge transfer modelling shows that lower temperature increases the concentration of contaminant at the cathode and facilitates their removal from the cell. By testing single cells under scenarios designed to mimic stack temperature dynamics, we investigate low-temperature operation as an approach to stack-relevant contaminant recovery. Together, these results demonstrate that the low-temperature recovery approach is a promising approach for acid-free contamination recovery for PEM water electrolysis to promote stack reliability and durability.
Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.
While the porous-transport layer (PTL) is a key component in PEM electrolyzers, it is one of the most underexplored due to limited available structures. In this work, we present a novel PTL design for PEM water electrolyzers enabled by a cost-effective, scalable tape-casting technique. Here, a precise control of the PTL pore structure is achieved by incorporating poreformers of various sizes, and by varying the titanium and poreformer ratio. The structures are characterized with SEM and synchrotron X-ray computed tomography imaging techniques. Comprehensive electrochemical performance analysis demonstrates that higher titanium loading provides improved contact at the catalyst-layer/PTL interface but suffers from severe mass-transport losses due to gas bubbles. We solve this mass-transport problem by mixing in large poreformer beads that produce a highly porous structure with excellent gas removal properties yet still maintaining mechanical integrity. The PTL fabricated with 60:40 Ti:PMMA ratio and 60 μm PMMA bead size outperformed the standard commercial Ti powder-based PTL by 62 mV at 4 A/cm 2 .
Hydrogen is emerging as a vital energy carrier, driven by the need to reduce carbon emissions. Proton Electrolyte Membrane Water Electrolysis (PEMWE) enables hydrogen production under fluctuating renewable power conditions but requires improved understanding and stability of the anode catalyst layer under dynamic operating conditions, especially with low noble metal loadings. Long-term degradation experiments are both time-consuming and costly; therefore, a systematic, model-aided approach is essential. In the present work, a temporal multiscale method is applied to reduce the computational effort of simulating long-term degradation processes in PEMWE, with an exemplary focus on catalyst dissolution. A mechanistic model incorporating the oxygen evolution reaction, catalyst dissolution, and hydrogen permeation from the cathode to the anode was hypothesized and implemented. In this way, the local periodicity of transport and reaction processes in dynamic PEMWE operation, which influence the gradual degradation of the catalyst layer, is captured. The temporal multiscale method significantly reduces the computational effort of simulation, decreasing processing time from hours to mere minutes. This efficiency gain is attributed to the limited evolution of Slow-Scale variables during each period of time P of the Fast-Scale variables. Consequently, simulation is required only until local periodicity is achieved within each Slow-Scale time step. Hence, the fully resolved dynamic problem is decoupled into these two scales, employing a heterogeneous multiscale technique. The developed approach effectively accelerates parameter estimation and predictive simulations, supporting systematic modeling of PEMWE degradation under dynamic conditions.
Iridium-based catalysts remain the most reliable option for the oxygen evolution reaction (OER) in proton exchange membrane water electrolyzers (PEMWEs). However, their high cost and limited performance represent critical barriers to the commercialization of this green hydrogen production technology. Herein, we report the creation of a metallic Ir nanowire network (IrNWN), which exhibits superior OER performance through its in-situ transition into an oxide structure with high intrinsic activity. At a low loading of 0.25 mgIr/cm2 in PEMWEs, IrNWN achieved a current density of 3.13 A/cm2 at a cell voltage of 1.8 V, outperforming the commercial Ir-based catalyst and surpassing the Department of Energy (DOE) 2026 technical target. Moreover, the high activity of IrNWN was maintained for 900 hours in a durability test at 2 A/cm2, showing a low degradation rate of 0.042 mV/hour. Structural analysis of the electrochemically oxidized IrNWN revealed the presence of mixed Ir oxidation states and a high density of surface terminal oxygen groups (μ1-O), which contributed to a reduced energy barrier for the rate-determining O-O coupling step.
Proton exchange membrane water electrolyzers rely on relatively expensive Ir-based catalysts for efficient and durable hydrogen production. To reduce system costs, Ir loadings can be reduced if performance and durability are maintained. Sputter deposition is a readily scalable method to synthesize uniform, low-loading catalyst layers with controlled composition. A catalyst applied directly to the porous transport layer can have advantages for performance, manufacturing simplicity, and catalyst recovery. Suitable porous transport layer porosity can minimize activity losses when reducing loadings. Here, methods are presented to deposit metallic Ir as well as amorphous and rutile Ir oxides. The activity and durability of these materials in the porous transport electrode architecture is evaluated. The metallic and amorphous forms have better initial activity, however, operation at 3 A cm −2 with 0.1 mg Ir cm −2 shows that only rutile IrO 2 maintains performance beyond 100 h with a 50 mV improvement after 700 h. A >10x reduced dissolution rate is shown for rutile IrO 2 . With a low-porosity transport layer and 0.4 mg Ir cm −2 , a steady-state voltage decay rate of 6 µV h −1 is achieved. The results demonstrate that sputter-deposited rutile IrO 2 porous transport electrodes with low Ir loading can be operated at high current density to reduce hydrogen production costs.
Electrochemical impedance spectroscopy (EIS) is a powerful tool to characterize and distinguish electrochemical, electrical, and diffusive processes in an electrolysis cell. The EIS response with small impedance (mΩ) depends on components and materials of the cell, but often also on the electrical setup, cables, and connectors, leading to incorrect conclusions about the performance of the electrolysis cells. These parasitic effects are assessed via a short-circuit measurement and confirmed to be external from the membrane electrode assembly (MEA). In the setup, the inductive characteristic is described by a modified inductive reactance and must be included in the equivalent circuit model (ECM) which is fitting the cell EIS spectra in operation (in situ). If points of the spectra showing inductive characteristic (below x-axis in Nyquist plot) are excluded from the ECM evaluation, an artificially increased ohmic resistance at high frequencies is obtained. In addition, considerations on other components of the ECM can be misleading and significantly incorrect. The only way to avoid that inductive behavior caused by the external setup is incorrectly assigned to the ECM describing properties of the MEA is to include the inductive effects in the ECM analysis of in situ EIS measurements.
A rationalized interfacial design strategy was applied to tailor the porous transport layer (PTL)-catalyst layer (CL) contact and the PTL bulk-phase architecture. Particularly, at the PTL-CL interface, our results reveal that laser ablated sintered titanium power-based PTLs improve electrolyzer performance at both the H2NEW Consortium baseline catalyst loading of 0.4 mgIr cm -2 as well as at the ultra-low catalyst loading of 0.055 mgIr cm -2 . Under ultra-low catalyst loadings, the laser ablated PTL demonstrates maximum reduction of 230 mV compared to the commercial PTL at 4 A cm -2 , and reduces by 68 mV at 3.2 A cm -2 under H2NEW baseline loading. Laser ablation alters the titanium phase at the interface, so it forms more uniform structure like a microporous layer or a backing layer, leading to an increase in the surface area in contact with the catalyst layer while preventing the membrane from deforming into the PTL. Moreover, we reveal that bulk-phase architecture modification of the PTL by ablating patterned pores at the flow field-PTL interface improves mass transport without sacrificing contact at the CL-PTL interface. Overall, laser ablation of the PTL is an effective method to customize interfacial design to enhance proton exchange membrane electrolyzer performance.
Proton-exchange membrane water electrolyzers (PEMWEs) are a promising technology for green hydrogen production; however, interfacial transport behaviors are poorly understood, hindering device performance and longevity. Here, we first utilized finite-gap electrolyzer to demonstrate the possibility of proton transfer through water in PEMWEs. The measured high-frequency resistances (HFRs) exhibit a linear trend with increasing gap distance, where extrapolation shows a lower value compared with HFRs in regular zero-gap electrolyzers, indicating that ohmic resistance could be further reduced. We introduce nanochannels to facilitate mass transport, as evidenced by both liquid-fed and vapor-fed electrolysis. Nanochannel electrodes achieve a voltage reduction of 190 mV at 9 A·cm –2 compared with the Ir-PTEs without nanochannels. Furthermore, nanochannel electrodes show negligible degradation through 100,000 accelerated-stress tests and over 2,000 h of operation at 1.8 A·cm –2 with a decay rate of 11.66 μV·h –1 . These results provide new insights into localized transport dynamics for PEMWEs and highlight the significance of interfacial engineering for electrochemical devices.
Hydrogen produced with no greenhouse gas emissions is termed “green hydrogen” and will be essential to reaching decarbonization targets set forth by nearly every country as per the Paris Agreement. Proton exchange membrane water electrolyzers (PEMWEs) are expected to contribute substantially to the green hydrogen market. However, PEMWE market penetration is insignificant, accounting for less than a gigawatt of global capacity. Achieving substantive decarbonization via green hydrogen will require PEMWEs to reach capacities of hundreds of gigawatts by 2030. This paper serves as an overarching roadmap for cell-level improvements necessary for gigawatt-scale PEMWE deployment, with insights from three well-established hydrogen technology companies included. Analyses will be presented for economies of scale, renewable energy prices, government policies, accelerated stress tests, and component-specific improvements.
Meeting a competitive 1$/kg hydrogen cost target for polymer electrolyte membrane water electrolysis (PEMWE) will require advances to significantly reduce capital costs and precious metal catalyst usage, while simultaneously enabling 40,000–80,000 h stack lifetimes under dynamic use conditions. Minimizing cell voltage decay rates is therefore a key goal for PEMWE, although the fundamental processes governing voltage decay are not yet well understood. Here we present a quantitative approach to analyze the contributions to voltage decay in long-term PEMWE testing using polarization curves, impedance spectroscopy, and post-mortem electron microscopy. We apply this approach to analyze a 28 μV h −1 decay rate observed in a 4000 h durability test of a cell using 0.5 mg cm −2 total PGM catalyst loading (0.4 mg Ir cm −2 anode, 0.1 mg Pt cm −2 cathode) and 3 A cm −2 current density. We also analyze a comparative series of 1000 h tests under different conditions. These results provide valuable insights into anode catalyst degradation processes, as well as transferrable methodology for PEMWE durability research.
In this project, advanced membranes and catalysts were integrated into membrane electrode assembles (porous transport electrodes (PTE) or catalyst coated membranes (CCM)) leveraging precision coating methods to enable control of electrode structures and demonstration of the best component performance possible with these materials. Partner collaborations allowed for advanced characterization of the formed interfaces and degradation mechanisms. New methods of forming hydrogen recombination layers were also developed, to move away from wet chemistry processes that would have limited realization and implementation of the optimized electrode configurations in a commercial environment.