SEARCH · Search NASA
Results for “PEM water electrolyzers”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Innovative Method for Reliable Measurement of PEM Water Electrolyzer Component Resistances
Understanding the sheet resistance of porous electrodes is essential for improving the performance of polymer electrolyte membrane (PEM) water electrolyzers and related technologies. Despite its importance, existing methods often fail to provide reliable and comprehensive data, especially for porous materials with complex morphologies and non‐uniform thicknesses. This study introduces a robust and straightforward method for determining the sheet resistance of porous electrodes using a novel probe concept based on industrial printed circuit board (PCB) technology. This probe measures resistance across ten distances, ranging from 250 µm to 2500 µm, enabling local mapping of resistance. The study focuses on the sheet resistance of key components in PEM water electrolyzers, including the gas diffusion layer (GDL), porous transport layer (PTL), and catalyst layers deposited on a membrane. Additionally, an image‐processing‐based method is presented to obtain the thickness distribution of the studied catalyst layers, facilitating a detailed analysis of the electrical in‐plane resistivity with thickness variations. Overall, this methodology has the potential to expedite material integration and bridge the gap between electrode engineering and single‐cell testing, thereby advancing the development of PEM water electrolyzers.
Impacts of PTL coating gaps on cell performance for PEM water electrolyzer
The anode porous transport layer (PTL) is a critical component of polymer electrolyte membrane (PEM) water electrolyzers, providing electrical conduction and water/oxygen transport to the anode catalyst layer. Platinum group metal (PGM) coatings are applied to titanium PTLs to prevent oxidation and preserve conductivity. To implement PEM water electrolysis on a large scale, it is essential to minimize the cost of mass-manufactured cell components while ensuring that defects in materials and components do not adversely affect the performance of the cell. In this study, we created gaps in the Pt coatings that are typically applied to PTLs to understand their effects on cell performance and inform on fabrication tolerances. The PTL coatings were fabricated by sputter deposition of Pt, intentionally leaving uncoated regions in either large patches or thin strips. For either geometry, the cell performance decreased with the increasing fraction of the uncoated regions. However, PTLs containing multiple thin uncoated strips caused a less severe performance effect than PTLs with continuous uncoated regions of the same relative total area. Through analysis of cell performance, impedance, and 3D charge transport modelling, here we demonstrate that both the anode catalyst layer and membrane play a role in distributing current to mitigate the impact of coating defects at a short length scale. These results allow to draw conclusions about the tolerance requirements with regards to PTL coating uniformity in terms of both the size and total area of defects.
Combining Distributed Electrochemical Measurements with a Semi-Empirical Model to Identify Local Variations in Overpotentials for PEM Water Electrolyzers
Abstract A segmented cell and PCB approach was used to demonstrate an advanced technique for measuring and understanding the electrochemical behavior of PEM water electrolyzers. By employing a semi-empirical model, discrete modes of overpotential and their spatial distributions were identified in an operating cell. Distributed area-specific resistance (DASR measurements indicate that local dehydration of the polymer electrolyte membrane is the primary driver of increased polarization, behaving similarly to mass transport-limited currents at low flow rates due to ineffective gas-phase bubble removal. To improve quantification, the overall ohmic overpotential is divided into background (η Ohm,b ) and mass transport-coupled (η Ohm,mt ) components. Two types of anode diffusion media, a baseline PTL and a thin foil liquid/gas diffusion layer (LGDL), were examined. The results show significant variations in η Ohm,b and highlight that ineffective bubble removal leads to pronounced local dehydration. The effect of cell temperature on various overpotentials was also examined. Negligible differences in diffusion overpotential were observed when comparing PEWE performance using the PTL and LGDL, despite major differences in two-phase fluid transport within each diffusion media. This underscores the critical role of the catalyst layer's micro-porous structure in diffusion processes. The study highlights the complex nature and intricacies of mass transport limitations within PEWEs.
Understanding the impact of the gas diffusion layer structure on catalyst utilization in the PEM water electrolyzer
A multiphysics half-cell model of a polymer electrolyte membrane water electrolyzer (PEMWE) was developed to probe impacts of the detailed 3-dimensional pore structure of the gas diffusion layer (GDL) on performance characteristics. We show that pores in the titanium GDL mesh led to significant underutilization of the catalyst layer (CL), with only 45% of the catalyst effectively utilized. This contradicts the assumption of uniform electron flow across the CL, as shown in graphical abstract (a), as near-zero current was observed near GDL pore regions and the current distribution in CL was influenced by GDL structure, as shown in graphical abstract (b). Instead, oxygen generation was primarily concentrated under the solid titanium regions, diffusing out around the pore walls. High current density peaks were also noted at the GDL-catalyst contact, correlating with degradation hotspots that were directly observed in companion experiments, as shown in graphical abstract (c). Collectively, these findings point to the critical importance of the heterogeneous GDL porous architecture not only for PEMWE efficiency but also for uneven degradation of the CL.
Innovative duo-recombination layer design for effective hydrogen crossover mitigation in advanced MEAs for PEM water electrolyzers
Hydrogen crossover in proton exchange membrane water electrolyzers (PEMWEs) poses a safety hazard, reduces the overall efficiency, and limits the operational differential pressure range. Here, in this study, a membrane electrode assembly (MEA) with innovative Pt duo-recombination layer (DRL) design is developed by the unique reactive spray deposition technology (RSDT). The novel design comprises two thin RLs integrated within the volume of the membrane and has a total Pt loading of only 0.04 mg Pt cm −2 . Long-term durability test for over 3000 h is performed with as-fabricated MEA at steady-state conditions typical for an industrial hydrogen production system. The results from the durability test show that the newly developed DRL design effectively suppresses the H2 crossover to below 0.5 vol%. Furthermore, comprehensive post-test characterization of the MEA is performed and potential failure mechanisms in the Pt RLs observed during the durability test are identified and discussed in detail for the first time.
Time of Flight Secondary Ion Mass Spectrometry for Characterization of Pt-Coated Porous Transport Layers in PEM Water Electrolyzers
Titanium-based porous transport layers (PTLs) and iridium-based catalyst layers (CLs) are two main components of proton exchange membrane water electrolyzers (PEMWEs). PTLs are typically coated with platinum to minimize interfacial losses and to support long-term operation. Optimizing coatings and the PTL-CL interface requires comprehensive characterization. This study establishes time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a valuable technique for PTL characterization, addressing capabilities and limitations related to PTL morphology. A methodology was developed that uses a Cs + sputter beam for dynamic depth profiling, with data collected in both positive-ion (MCs + ) and negative-ion modes to generate depth profiles, 2D ion maps, and 3D ion reconstructions. ToF-SIMS detected relative differences in platinum-layer thickness between samples; these trends were validated by cross-sectional scanning transmission electron microscope (STEM) measurements and flat-titanium substrate controls. Interfacial oxide layers are identified in both ion modes, with enhanced oxide sensitivity in negative mode. The technique’s high sensitivity enables detection of nanometer-scale coatings and trace impurities within the bulk PTL structure. These results provide a methodological framework for analyzing Pt-coated PTLs, with the potential to extend to other components in PEMWEs and other electrolyzer systems.
Importance of hydrogen oxidation reaction current in quantifying hydrogen crossover in PEM water electrolyzers at high differential pressure
Understanding hydrogen permeation in proton exchange membrane water electrolyzers (PEMWEs) operating at high differential pressures (>25 bar) is critical towards developing effective gas recombination strategies that enable safe operation and high efficiency. Developing this understanding relies on accurate quantification of hydrogen crossover rates in water electrolyzers operating under such conditions. In this work, we show that PEMWEs operating at high differential pressures exhibit noticeable hydrogen oxidation reaction (HOR) currents. As the HOR consumes part of the permeated hydrogen at the anode, neglecting HOR currents leads to severe underestimation of the hydrogen crossover rate. We implemented a new method combining hydrogen oxidation current with online gas chromatography measurements to accurately quantify hydrogen crossover rates as a function of operating current density in PEMWEs operating at high differential pressures (10–30 bar g ).
Degradation Mechanisms in Advanced MEAs for PEM Water Electrolyzers Fabricated by Reactive Spray Deposition Technology
Proton exchange membrane water electrolyzers (PEMWEs) have demonstrated enormous potential as the next generation hydrogen production technology. The main challenges that the state-of-the-art PEMWEs are currently facing are excessive cost and poor durability. Understanding the failure modes in PEMWEs is a key factor for improving their durability, lowering the precious metal loading, and hence cost reduction. Here, reactive spray deposition technology (RSDT) has been used to fabricate a membrane electrode assembly (MEA) with one order of magnitude lower Pt and Ir catalyst loadings (0.2–0.3 mg PGM cm –2 ) in comparison to the precious metal loadings in the stat-of-the-art commercial MEAs (2–3 mg PGM cm –2 ). As fabricated MEA with an active area of 86 cm 2 , has been tested for over 5000 h at steady-state conditions that are typical for an industrial hydrogen production system. Herein, we present and discuss the results from a comprehensive post-test analysis of the MEA of interest. The main degradation mechanisms, governing the performance loss in the RSDT fabricated MEA with ultra-low precious metal loadings, have been identified and discussed in detail. All failure modes are critically compared and the main degradation mechanism with the highest impact on the MEA performance loss among the others is identified.
Low-Cost, High Performance Catalyst Coated Membranes for PEM Water Electrolyzers (Final Technical Report)
In this project, the objective was to develop reduced-cost manufacturing techniques capable of producing proton exchange membrane water electrolyzer (PEMWE) catalyst coated membranes (CCMs) with further improved performance relative to then-current 3M CCM technology. Processes to be developed would enable 1) production of 0.5 m wide CCMs (approximately 2x wider than produced by the current laboratory/pilot-scale processes) and 2) 3x higher net-effective linear rates (lineal-meters of CCM produced per cumulative process time) than the baseline CCM process. In combination, the wider width CCM and increased net-effective linear rates would result in a 6-fold decrease in CCM manufacturing cost (defined as cumulative machine and labor time) per m 2 of CCM produced. PEMWE CCMs produced with these optimized processes were targeted to produce 1) 0.25 A/cm 2 or greater at 1.5 V, 2) 2.0 A/cm 2 or greater at 1.75 V and 3) 4 A/cm 2 or greater at 1.95V, 4) with total catalyst platinum-group metal (PGM) loadings of ≤ 0.50 mg/cm 2 , measured in a cell with 50 cm 2 active area (or larger) at 80°C cell temperature and ambient outlet pressures.
Compressive Creep of Polymer Electrolyte Membranes: A Case Study for Electrolyzers
For proton-exchange membrane (PEM) water electrolyzers to be commercially feasible, PEMs must perform over long lifetimes in liquid environments under compression while maintaining mechanical stability. A hydrated environment, while inherent for operation and conductivity, undermines PEM stability. Mechanical stability of PEMs is commonly characterized in tension, which is not applicable to electrolyzers, wherein PEMs could undergo high pressures. In this study, a compression creep procedure is developed using a custom-designed setup to monitor creep response of hydrated PEMs. Furthermore, our results show that PEMs exhibit continuous creep response under compression over 24 h, with a dependence on the applied pressure and hydration state.
Evaluating the Case for Reduced Precious Metal Catalysts in Proton Exchange Membrane Electrolyzers
Proton exchange membrane (PEM) water electrolyzers are a key technology in decarbonizing hydrogen production. Though the market for PEM electrolyzer systems is growing, there are concerns that the cost and availability of precious metal catalysts utilized in today’s commercial systems can limit deployment. Herein, we show that while the availability of Ir should not impede deployment in the near term, the inelasticity of the Ir commodity price is cause for immediate concern. Here we emphasize that diversifying catalyst materials, even with other precious metals, can reduce system costs and mitigate supply chain risk. Furthermore, we analyze the trade-offs between catalyst capital cost and catalyst activity for a range of operating conditions (i.e., capacity factor, electricity price). The framework presented herein is a first step toward establishing performance targets (i.e., activity, stability, material cost) for reduced precious metal and non-precious metal catalysts as a function of PEM electrolyzer operating conditions.
Hybrid Ionomer-Free Porous Transport Electrodes With Catalyst Coated Membranes for Enhanced Water Electrolysis
To promote industrial uptake of clean hydrogen production technologies such as polymer electrolyte membrane (PEM) water electrolyzers, advancements in catalyst layer (CL) morphology are required. We demonstrate how improved electrochemical performance can be achieved when using an ionomer free porous transport electrode (PTE) coupled with a traditional catalyst coated membrane (CCM) assembly in PEM water electrolyzers. Notably, we reveal that the superior performance achieved when utilizing a hybrid PTE and CCM assembly is due to enhanced ohmic performance caused by optimal contact with both the porous transport layer (PTL) and PEM interfaces. Using operando neutron radiography, we demonstrate that configurations utilizing a CCM resulted in more rapid water replenishment to reaction sites, indicating enhanced membrane hydration beneficial for performance. This enhanced membrane hydration coupled with improved contact area at the PEM-catalyst layer (CL) and PTL-CL interfaces was revealed through the reduced ohmic overpotentials of the hybrid PTE-CCM design, which achieved the lowest ohmic overpotential of 431 mV at 2000 mA cm−2. While the average in-plane water distributions are generally similar between cell configurations, we reveal that utilizing a PTE configuration promotes a more homogenous water distribution near the CL-membrane interface due to enhanced catalyst utilization.
Aging iridium oxide catalyst inks: a formulation strategy to enhance ink processability for polymer electrolyte membrane water electrolyzers
Steady-shear rheology showing evolution of the microstructure of iridium oxide catalyst inks of PEM water electrolyzers with aging time.
Titanium porous-transport layers for PEM water electrolysis prepared by tape casting
While the porous-transport layer (PTL) is a key component in PEM electrolyzers, it is one of the most underexplored due to limited available structures. In this work, we present a novel PTL design for PEM water electrolyzers enabled by a cost-effective, scalable tape-casting technique. Here, a precise control of the PTL pore structure is achieved by incorporating poreformers of various sizes, and by varying the titanium and poreformer ratio. The structures are characterized with SEM and synchrotron X-ray computed tomography imaging techniques. Comprehensive electrochemical performance analysis demonstrates that higher titanium loading provides improved contact at the catalyst-layer/PTL interface but suffers from severe mass-transport losses due to gas bubbles. We solve this mass-transport problem by mixing in large poreformer beads that produce a highly porous structure with excellent gas removal properties yet still maintaining mechanical integrity. The PTL fabricated with 60:40 Ti:PMMA ratio and 60 μm PMMA bead size outperformed the standard commercial Ti powder-based PTL by 62 mV at 4 A/cm 2 .
Identifying electrochemical processes by distribution of relaxation times in proton exchange membrane electrolyzers
Distribution of relaxation time (DRT) is used to interpret electrochemical impedance spectroscopy (EIS) for proton exchange membrane (PEM) water electrolyzers, with an attempt to separate overlapped relaxation processes in Nyquist plots. By varying operating conditions and catalyst loadings, four main relaxation peaks arising from EIS can be identified and successfully separated from low to high frequencies as (P1) mass transport, (P2) oxygen evolution reaction kinetics, (P3) reaction kinetics (with faster time constant than P2), and (P4) ionic transport. Here, the shape, height, and frequency of the DRT peaks change with different membrane electrode assembly (MEA) configurations. Electron microscopy reveals distinct features from the cross-sectioned MEAs which verify critical DRT results in that increasing the iridium (Ir)-anode loading from 0.2 mgIr/cm 2 to 1.5 mgIr/cm 2 reduces kinetic losses due to higher site-access; a thick and compacted anode, however, also triggers higher ohmic resistances from membrane/catalyst layer hydration and increases transport losses due to longer ionomer pathways. DRT provides higher resolution to EIS for deconvoluting processes with different relaxation times and the quantification of DRT peaks improves the accounting of total losses from each process.
An Acid-Free, Temperature-Based Cation Contamination Removal Strategy for PEM Water Electrolysis
It is widely understood that the durability and reliability of polymer electrolyte membrane (PEM) water electrolyzers are heavily dependent on feedwater purity, with cation contaminants that originate from incomplete water purification and balance of plant materials significantly harming electrolyzer performance. However, contamination remains a challenge and a common cause of failure at the stack level, indicating the need for strategies to recover the performance of contaminated cells. In this study, we investigate the effects of temperature on the uptake, electrochemical impacts, and removal of contaminant calcium and iron cations. Lower operating temperatures increase the sensitivity of the cell performance to contaminant cations, while also decreasing cation uptake and promoting contaminant removal. Computational charge transfer modelling shows that lower temperature increases the concentration of contaminant at the cathode and facilitates their removal from the cell. By testing single cells under scenarios designed to mimic stack temperature dynamics, we investigate low-temperature operation as an approach to stack-relevant contaminant recovery. Together, these results demonstrate that the low-temperature recovery approach is a promising approach for acid-free contamination recovery for PEM water electrolysis to promote stack reliability and durability.
How Low Can You Go? Nanoscale Membranes for Efficient Water Electrolysis
Motivated by the need to lower the cost of hydrogen (H 2 ) production by water electrolysis, significant research efforts are focused on making proton (H + ) exchange membrane (PEM) water electrolyzers more efficient and capable of operating at higher current densities. These aims can be met by making H + -conducting membranes thinner, which has the effect of lowering ohmic drops across the membrane that represent the largest efficiency loss at high current densities (>2 A cm –2 ). However, decreasing membrane thickness below 50 μm is not trivial due to trade-offs between membrane resistance, H 2 crossover (safety), membrane degradation, and manufacturing throughput. Furthermore, descriptions of key processes, limitations, and trade-offs that arise in thin membranes are provided that can be used to guide the design of ultrathin (i.e., submicron thick), low-resistance membrane materials that have the potential to transform the field of clean H 2 production.