Search NASA⌕ Search

SEARCH · Search NASA

Results for “PEMs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Innovative Method for Reliable Measurement of PEM Water Electrolyzer Component Resistances

Understanding the sheet resistance of porous electrodes is essential for improving the performance of polymer electrolyte membrane (PEM) water electrolyzers and related technologies. Despite its importance, existing methods often fail to provide reliable and comprehensive data, especially for porous materials with complex morphologies and non‐uniform thicknesses. This study introduces a robust and straightforward method for determining the sheet resistance of porous electrodes using a novel probe concept based on industrial printed circuit board (PCB) technology. This probe measures resistance across ten distances, ranging from 250 µm to 2500 µm, enabling local mapping of resistance. The study focuses on the sheet resistance of key components in PEM water electrolyzers, including the gas diffusion layer (GDL), porous transport layer (PTL), and catalyst layers deposited on a membrane. Additionally, an image‐processing‐based method is presented to obtain the thickness distribution of the studied catalyst layers, facilitating a detailed analysis of the electrical in‐plane resistivity with thickness variations. Overall, this methodology has the potential to expedite material integration and bridge the gap between electrode engineering and single‐cell testing, thereby advancing the development of PEM water electrolyzers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Carbon Support Heat Treatment on the Performance of Ion-Pair High-Temperature PEM Fuel Cells

Heat treatment can significantly alter the physical and chemical properties of carbon supports, thereby influencing the performance of proton exchange membrane (PEM) fuel cells. This study explores how varying carbon heat treatment temperatures—from 1,000 °C to 2,200 °C—affect the structure and performance of platinum-based catalysts in high-temperature PEM fuel cells. Increasing the heat treatment temperature led to a notable decrease in surface area, along with increases in carbon grain size and hydrophobicity. Although the catalyst supported on carbon treated at 1,000 °C exhibited the highest catalyst activity, the MEA using carbon treated at 1,500 °C delivered the best overall fuel cell performance. This is attributed to an optimized balance between hydrophobicity and accessible surface area, which enhances water management and catalyst utilization. These findings underscore the importance of carbon support engineering in improving the efficiency of ion-pair high-temperature PEM fuel cells.

08 HYDROGEN↗

Catalyst-Vision (PEM Catalyst Layer Image Analysis Tool) [SWR-25-100]

Catalyst-Vision (PEM Catalyst Layer Image Analysis Tool) provides an advanced Python-based tool, primarily designed for use in a Jupyter/Colab notebook, for the quantitative morphological analysis of pre-segmented shapes. While developed for analyzing PEM catalyst layers from microscopy, its methodology is suitable for characterizing any grayscale object provided on a uniform white background. The tool uses a robust computer vision pipeline based on the Euclidean Distance Transform and skeletonization to accurately measure local thickness and tortuosity, providing a comprehensive characterization of an object's geometry and internal texture. If you find this code useful, please cite our preprint as: Chan, Ai-Lin and Hayden, Steven and Harvey, Steven P. and Smeaton, Michelle and Okrucky, Caleb and Watt, John and Ulična, Soňa and Spurgeon, Steven and Jungjohann, Katherine and Alia, Shaun, Mechanism-informed breakdown: understanding degradation by controlling voltage hold patterns in PEM water electrolyzers. Preprint (2025).

Spurgeon, Steven [National Laboratory of the Rocki↗

Advanced PEM Electrolyzer Membrane for Hydrogen Crossover Mitigation

An unintended reaction in the electrochemical conversion of water to hydrogen in proton exchange membrane (PEM) electrolyzers is the crossover of hydrogen from the anode to the oxygen-containing cathode through the membrane, creating hydrogen losses and safety concerns. Efforts to date have focused on embedding platinum catalysts in perfluorosulfonic (PFSA) membranes to convert H 2 to protons. The objective of this project is to design and develop hydrocarbon (HC) proton exchange membranes (PEMs) that can help overcome the risk of high H 2 crossover in current PEM electrolyzer (ELX) stacks by designing and optimizing the gas recombination catalyst (GRC) within the membrane and membrane electrode assembly (MEA) structure.

08 HYDROGEN↗

Tantalum oxide stabilized molybdenum-doped ruthenium oxide electrocatalysts for PEM water electrolysis

Proton exchange membrane (PEM) water electrolysis offers key advantages, including high current density, high efficiency, and compact system architecture for hydrogen production. However, its widespread implementation is limited by the scarcity and high cost of Ir-based anodic catalysts. Herein, we report an Ir-free electrocatalyst for the acidic oxygen evolution reaction (OER): tantalum oxide (TaO x )–coated molybdenum-doped RuO 2 (TaO x -MoRuO 2 ). The catalyst exhibits a low overpotential of 180 mV at 10 mA cm -2 and excellent durability, with a degradation rate of 0.034 mV h -1 over a 150-hour test at 50 mA cm -2 —surpassing other Ru-based catalysts evaluated under similar conditions. A PEM electrolyzer employing TaO x -MoRuO 2 as the anode maintained stable operation for 100 hours at 500 mA cm -2 . In conclusion, the TaO x coating layer suppresses Ru and Mo dissolution, thus enhancing their stability likely via interfacial electronic reconfiguration of Ru and Mo mediated by bridging oxygen atoms.

Durability↗

Performance Losses and Current-Driven Recovery from Cation Contaminants in PEM Water Electrolysis

Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.

30 DIRECT ENERGY CONVERSION↗

An Acid-Free, Temperature-Based Cation Contamination Removal Strategy for PEM Water Electrolysis

It is widely understood that the durability and reliability of polymer electrolyte membrane (PEM) water electrolyzers are heavily dependent on feedwater purity, with cation contaminants that originate from incomplete water purification and balance of plant materials significantly harming electrolyzer performance. However, contamination remains a challenge and a common cause of failure at the stack level, indicating the need for strategies to recover the performance of contaminated cells. In this study, we investigate the effects of temperature on the uptake, electrochemical impacts, and removal of contaminant calcium and iron cations. Lower operating temperatures increase the sensitivity of the cell performance to contaminant cations, while also decreasing cation uptake and promoting contaminant removal. Computational charge transfer modelling shows that lower temperature increases the concentration of contaminant at the cathode and facilitates their removal from the cell. By testing single cells under scenarios designed to mimic stack temperature dynamics, we investigate low-temperature operation as an approach to stack-relevant contaminant recovery. Together, these results demonstrate that the low-temperature recovery approach is a promising approach for acid-free contamination recovery for PEM water electrolysis to promote stack reliability and durability.

08 HYDROGEN↗

Manufacturing Cost Analysis for PEM Electrolyzers and Perspectives for Future Cost Reduction

Electrolyzer capital costs strongly influence the total levelized cost of hydrogen production and have implications for hydrogen deployment. Current electrolyzer costs are high, and large cost reductions may be needed to achieve competitive hydrogen costs and targets. Understanding pathways for cost reduction via R&D and deployment is a critical research area for informed energy planning and enabling hydrogen use. This work presents bottom-up cost estimates of polymer electrolyte membrane (PEM) electrolyzer systems tied to design specifications and discusses perspectives for cost reduction opportunities based on ongoing research. We use a detailed manufacturing and process model for a 1 MW PEM electrolyzer stack and balance of plant (BOP) for rigorous cost estimation. This allows for robust estimates of component and manufacturing costs and examination of key cost contributors. Stack costs are dominated by material costs such as iridium and platinum catalysts, especially at high manufacturing rates; power electronics and hydrogen purification equipment are the largest contributors to BOP cost. At higher manufacturing rates, better equipment utilization could reduce stack costs significantly, and we estimate that experience and bulk purchasing will allow for cost reductions to some BOP components. Still, many well-established BOP technologies and stack material costs are less likely to see significant cost reductions at high manufacturing rates. As such, manufacturing scale is limited in how much it can reduce electrolyzer costs, and additional advances for cost reduction may be needed to achieve cost targets. It will likely take many combined strategies to achieve significant cost reductions for electrolyzers and enable low-cost hydrogen production. We can use our manufacturing cost model to quantify potential cost reductions from the considerations described above and demonstrate pathways to lower cost electrolyzers. This allows for better understanding of cost reduction strategies and enables more informed research, development, and deployment for electrolyzers.

cost↗

Challenges and strategies for probing the composite interface of PEM electrolyzers and fuel cells using operando AP-XPS

Left: cross-section schematic of a membrane electrode assembly, the working electrode changing state with applied potential. Center: the operando cell design that enables snapshot data acquisition during trajectory movement. Right: resulting spectra. Understanding the surface chemistry of electrocatalyst systems under operando conditions is central to revealing the electrocatalytic cell's working mechanisms. Determination of these catalytic processes on a molecular scale and the involved components is fundamental to streamlining material design for energy conversion and storage applications. X-ray photoelectron spectroscopy (XPS) is an established technique used to study the chemical and electronic states of materials. While the surface sensitivity of XPS is typically high, use of tender X-ray energies and technical advancements have allowed for the direct probing of solid–vapor and solid–liquid interfaces. However, protocols and documentation of experimental considerations for operando XPS probing of working electrolyzers and fuel cells remain scarce. Herein, we report an approach for the study of working polymer electrolyte membrane (PEM) electrolysis cells using ambient pressure X-ray photoelectron spectroscopy (AP-XPS). This approach directly probes the composite electrode surface on the membrane electrode assembly (MEA) in 100% relative humidity to establish a meaningful liquid layer for electrocatalysis. We carry out a systematic investigation from the cell constituent components to a fully assembled working operando electrolytic system and establish a method for AP-XPS study of the complex composite MEA, providing recommendations for data acquisition and component analysis.

Hamlyn, Rebecca↗

Combining Distributed Electrochemical Measurements with a Semi-Empirical Model to Identify Local Variations in Overpotentials for PEM Water Electrolyzers

Abstract A segmented cell and PCB approach was used to demonstrate an advanced technique for measuring and understanding the electrochemical behavior of PEM water electrolyzers. By employing a semi-empirical model, discrete modes of overpotential and their spatial distributions were identified in an operating cell. Distributed area-specific resistance (DASR measurements indicate that local dehydration of the polymer electrolyte membrane is the primary driver of increased polarization, behaving similarly to mass transport-limited currents at low flow rates due to ineffective gas-phase bubble removal. To improve quantification, the overall ohmic overpotential is divided into background (η Ohm,b ) and mass transport-coupled (η Ohm,mt ) components. Two types of anode diffusion media, a baseline PTL and a thin foil liquid/gas diffusion layer (LGDL), were examined. The results show significant variations in η Ohm,b and highlight that ineffective bubble removal leads to pronounced local dehydration. The effect of cell temperature on various overpotentials was also examined. Negligible differences in diffusion overpotential were observed when comparing PEWE performance using the PTL and LGDL, despite major differences in two-phase fluid transport within each diffusion media. This underscores the critical role of the catalyst layer's micro-porous structure in diffusion processes. The study highlights the complex nature and intricacies of mass transport limitations within PEWEs.

Roy, Anirban (ORCID:0000000163803386)↗

Application of a temporal multiscale method for efficient simulation of degradation in PEM Water Electrolysis under dynamic operating conditions

Hydrogen is emerging as a vital energy carrier, driven by the need to reduce carbon emissions. Proton Electrolyte Membrane Water Electrolysis (PEMWE) enables hydrogen production under fluctuating renewable power conditions but requires improved understanding and stability of the anode catalyst layer under dynamic operating conditions, especially with low noble metal loadings. Long-term degradation experiments are both time-consuming and costly; therefore, a systematic, model-aided approach is essential. In the present work, a temporal multiscale method is applied to reduce the computational effort of simulating long-term degradation processes in PEMWE, with an exemplary focus on catalyst dissolution. A mechanistic model incorporating the oxygen evolution reaction, catalyst dissolution, and hydrogen permeation from the cathode to the anode was hypothesized and implemented. In this way, the local periodicity of transport and reaction processes in dynamic PEMWE operation, which influence the gradual degradation of the catalyst layer, is captured. The temporal multiscale method significantly reduces the computational effort of simulation, decreasing processing time from hours to mere minutes. This efficiency gain is attributed to the limited evolution of Slow-Scale variables during each period of time P of the Fast-Scale variables. Consequently, simulation is required only until local periodicity is achieved within each Slow-Scale time step. Hence, the fully resolved dynamic problem is decoupled into these two scales, employing a heterogeneous multiscale technique. The developed approach effectively accelerates parameter estimation and predictive simulations, supporting systematic modeling of PEMWE degradation under dynamic conditions.

08 HYDROGEN↗

Innovative duo-recombination layer design for effective hydrogen crossover mitigation in advanced MEAs for PEM water electrolyzers

Hydrogen crossover in proton exchange membrane water electrolyzers (PEMWEs) poses a safety hazard, reduces the overall efficiency, and limits the operational differential pressure range. Here, in this study, a membrane electrode assembly (MEA) with innovative Pt duo-recombination layer (DRL) design is developed by the unique reactive spray deposition technology (RSDT). The novel design comprises two thin RLs integrated within the volume of the membrane and has a total Pt loading of only 0.04 mg Pt cm −2 . Long-term durability test for over 3000 h is performed with as-fabricated MEA at steady-state conditions typical for an industrial hydrogen production system. The results from the durability test show that the newly developed DRL design effectively suppresses the H2 crossover to below 0.5 vol%. Furthermore, comprehensive post-test characterization of the MEA is performed and potential failure mechanisms in the Pt RLs observed during the durability test are identified and discussed in detail for the first time.

08 HYDROGEN↗

Understanding the impact of the gas diffusion layer structure on catalyst utilization in the PEM water electrolyzer

A multiphysics half-cell model of a polymer electrolyte membrane water electrolyzer (PEMWE) was developed to probe impacts of the detailed 3-dimensional pore structure of the gas diffusion layer (GDL) on performance characteristics. We show that pores in the titanium GDL mesh led to significant underutilization of the catalyst layer (CL), with only 45% of the catalyst effectively utilized. This contradicts the assumption of uniform electron flow across the CL, as shown in graphical abstract (a), as near-zero current was observed near GDL pore regions and the current distribution in CL was influenced by GDL structure, as shown in graphical abstract (b). Instead, oxygen generation was primarily concentrated under the solid titanium regions, diffusing out around the pore walls. High current density peaks were also noted at the GDL-catalyst contact, correlating with degradation hotspots that were directly observed in companion experiments, as shown in graphical abstract (c). Collectively, these findings point to the critical importance of the heterogeneous GDL porous architecture not only for PEMWE efficiency but also for uneven degradation of the CL.

COMSOL↗

Cummins PEM Fuel Cell System for Heavy Duty Applications

The motivation for this project was to develop a high-pressure 100+ kW fuel cell stack that can be used in a modular fashion to power HD applications up to 1 MW. One of the issues that was identified during fuel cell system integration was the need for extra space for heat rejection systems(radiators) as well as additional fans and associated energy consumption to compensate for lower operating temperatures of fuel cells compared to internal combustion (IC) engines. To maximize the heat rejection capability of existing water-based coolant systems that are prevalent on IC engine-based systems, fuel cell stack design was developed to withstand and operate at IC engine coolant temperatures or higher, which in turn helps to reduce the radiator size requirement.

08 HYDROGEN↗

Complete Phase Transformation of Ir Nanowire Network into Defect-Rich Oxide Catalyst for High-Performance PEM Water Electrolysis

Iridium-based catalysts remain the most reliable option for the oxygen evolution reaction (OER) in proton exchange membrane water electrolyzers (PEMWEs). However, their high cost and limited performance represent critical barriers to the commercialization of this green hydrogen production technology. Herein, we report the creation of a metallic Ir nanowire network (IrNWN), which exhibits superior OER performance through its in-situ transition into an oxide structure with high intrinsic activity. At a low loading of 0.25 mgIr/cm2 in PEMWEs, IrNWN achieved a current density of 3.13 A/cm2 at a cell voltage of 1.8 V, outperforming the commercial Ir-based catalyst and surpassing the Department of Energy (DOE) 2026 technical target. Moreover, the high activity of IrNWN was maintained for 900 hours in a durability test at 2 A/cm2, showing a low degradation rate of 0.042 mV/hour. Structural analysis of the electrochemically oxidized IrNWN revealed the presence of mixed Ir oxidation states and a high density of surface terminal oxygen groups (μ1-O), which contributed to a reduced energy barrier for the rate-determining O-O coupling step.

oxygen evolution reaction↗

Durable Thin‐Film Porous Transport Electrodes for High Current Density PEM Water Electrolysis

Proton exchange membrane water electrolyzers rely on relatively expensive Ir-based catalysts for efficient and durable hydrogen production. To reduce system costs, Ir loadings can be reduced if performance and durability are maintained. Sputter deposition is a readily scalable method to synthesize uniform, low-loading catalyst layers with controlled composition. A catalyst applied directly to the porous transport layer can have advantages for performance, manufacturing simplicity, and catalyst recovery. Suitable porous transport layer porosity can minimize activity losses when reducing loadings. Here, methods are presented to deposit metallic Ir as well as amorphous and rutile Ir oxides. The activity and durability of these materials in the porous transport electrode architecture is evaluated. The metallic and amorphous forms have better initial activity, however, operation at 3 A cm −2 with 0.1 mg Ir cm −2 shows that only rutile IrO 2 maintains performance beyond 100 h with a 50 mV improvement after 700 h. A >10x reduced dissolution rate is shown for rutile IrO 2 . With a low-porosity transport layer and 0.4 mg Ir cm −2 , a steady-state voltage decay rate of 6 µV h −1 is achieved. The results demonstrate that sputter-deposited rutile IrO 2 porous transport electrodes with low Ir loading can be operated at high current density to reduce hydrogen production costs.

08 HYDROGEN↗

Surface Functionalization of Carbon Black for PEM Fuel Cell Electrodes

Abstract Carbon‐based materials are extensively used in fuel cell applications due to their crucial role in maintaining high performance. Particularly, carbon black (CB) stands out as a preferred electrode material for fuel cells, owing to its high electrical conductivity and large surface area. This review focuses on the functionalization of CB and its use as a support for Pt‐based catalysts in proton exchange membrane fuel cells. Functionalization strategies include oxidation, covalent functionalization, as well as polymer grafting or impregnation. Various approaches to functionalize the CB surface are discussed that effectively tailor the surface properties of electrodes, leading to improved fuel cell performance. The improvements are seen in enhanced dispersibility of catalyst particles, better ionomer distribution, increased catalyst stability, and reduced carbon corrosion. This review provides an overview of various modifications applied to CB to enhance their structural and electrochemical properties, thereby boosting fuel cell performance.

74 ATOMIC AND MOLECULAR PHYSICS↗