Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERMITTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

RCRA Part A Permit Application for Waste Management Activities at the Nevada Test Site, Part B Permit Application Hazardous Waste Storage Unit, Nevada Test Site, and Part B Permit Application - Explosives Ordnance Disposal Unit (EODU)

The Area 5 Hazardous Waste Storage Unit (HWSU) was established to support testing, research, and remediation activities at the Nevada Test Site (NTS), a large-quantity generator of hazardous waste. The HWSU, located adjacent to the Area 5 Radioactive Waste Management Site (RWMS), is a prefabricated, rigid steel-framed, roofed shelter used to store hazardous nonradioactive waste generated on the NTS. No offsite generated wastes are managed at the HWSU. Waste managed at the HWSU includes the following categories: Flammables/Combustibles; Acid Corrosives; Alkali Corrosives; Oxidizers/Reactives; Toxics/Poisons; and Other Regulated Materials (ORMs). A list of the regulated waste codes accepted for storage at the HWSU is provided in Section B.2. Hazardous wastes stored at the HWSU are stored in U.S. Department of Transportation (DOT) compliant containers, compatible with the stored waste. Waste transfer (between containers) is not allowed at the HWSU and containers remain closed at all times. Containers are stored on secondary containment pallets and the unit is inspected monthly. Table 1 provides the metric conversion factors used in this application. Table 2 provides a list of existing permits. Table 3 lists operational Resource Conservation and Recovery Act (RCRA) units at the NTS and their respective regulatory status.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Policy, Permit, Perform: Using City Benchmarking Data and Building Construction Permit History to Identify Energy Performance Improvements

The City of Portland (City) and Multnomah County 2015 Climate Action Plan targets a 40 percent reduction in carbon emissions below 1990 levels by 2030. To reach this goal, the plan includes a key objective to reduce the total energy use of existing buildings by 25 percent. Buildings are responsible for one-half of carbon emissions in Portland, Oregon, U.S., and improving their performance is critical to achieving the City’s climate goals. As part of its climate action planning, the City passed an ordinance on April 22, 2015, requiring commercial buildings 20,000 ft2 and larger to benchmark and disclose annual energy performance metrics through ENERGY STAR® Portfolio Manager® (ESPM), including greenhouse gas emissions, building energy use intensity (EUI) and ENERGY STAR scores. Twenty-five cities in the U.S. have adopted similar policies requiring energy benchmarking. These policies are generating a treasure trove of data about the drivers of building performance, but practitioners are only beginning to link benchmarking data to other datasets to produce actionable insight into improving building performance. In 2016, the City received a financial assistance award from the U.S. Department of Energy (DOE) through the Cities Leading through Energy Analysis and Planning project (Award Number DE-0007737). Portland’s project evaluated the application of the DOE Building Energy Asset Score Tool and rating system developed by Pacific Northwest National Laboratory (PNNL) to commercial buildings that report to the City. The City used building construction permit history to develop Asset Scores for a set of office buildings that reported energy performance for 2015 – the first year the City mandated energy benchmarking and reporting for commercial buildings 50,000 ft2 and larger. The primary project objective was to link energy benchmarking data and commercial building permit data to analyze commercial buildings systems that present the best, specific opportunities to improve energy performance. Integrating these datasets from two City departments, the Bureau of Development Services and the Bureau of Planning and Sustainability, could expand Portland’s use of analytics to inform climate policy decisions and strategic targeting of financial incentives for building owners and managers who are best positioned to improve the performance of their buildings. The project began with the commercial benchmarking data received for 340 commercial buildings that submitted calendar year 2015 energy reports. The City retained Research Into Action and Energy 350 (RIA team) to evaluate this self-reported benchmarking data. Based on a survey of 53 building managers, the RIA team found that most respondents used the City’s compliance tools, including a How-to Guide and Help Desk, and found access to utility data to be straightforward. However, almost one-third of the respondents encountered challenges when estimating the gross floor area (GFA), and some experienced confusion regarding the input of property use types and details into ESPM. Based on the RIA team’s recommendations, the City refined its How-to Guide, created online answers to frequently asked questions, and hosted office hour sessions to help building managers accurately characterize their building’s physical characteristics and operations in ESPM. Concurrently with the RIA team’s evaluation, the City worked with PNNL to estimate DOE Asset Score Preview (Preview) scores for 181 of the 340 commercial buildings that submitted ESPM reports to the City. Asset Score Tool is a web-based tool developed by PNNL for DOE to evaluate and rate the as-built energy efficiency of a building. Asset Score Tool’s full analysis capability runs a detailed energy model based on building geometry, age, envelope, lighting and mechanical systems using standard operating assumptions to give the building a score, similar to a miles per gallon rating for a car. Preview, a simplified deployment of the full Asset Score Tool, provides a preliminary score range using only seven data points, six of which are readily available in the ESPM benchmarking data. Analysis of the combined Preview scores and the operational ESPM scores identified buildings with a high potential for energy improvements through either retro-commissioning and retuning of existing operations or capital investments into building systems. The City contracted Whole Building Solutions (WBS) to mine building permit history and develop full Asset Scores for a subset of 26 office buildings that were eligible for both ENERGY STAR scores and Asset Scores. WBS researched permits and building plans to identify mechanical, lighting and envelope systems and other building characteristics necessary to complete Asset Scores. This historical data was recorded using the web-based Asset Score Tool, which evaluates the as designed energy efficiency of existing buildings. Much of this City information was available online after 2010; however, WBS had to search through microfiche files and the City’s database to obtain permit and plan history prior to 2010. Although building geometry, mechanical system type and basic envelope information was consistently identifiable, WBS found permit data gaps that prevented complete and accurate Asset Scores for most of the office buildings. If the City decides to develop Asset Scores based on building permit information in the future, WBS recommended requiring lighting plans, control diagrams and as-built drawings that reflect how the buildings are actually constructed. In addition, WBS recommended uploading plans and permits from microfiche storage into a more comprehensive, searchable database consistent with the City’s current online permit information. To identify the actual lighting types, WBS and City staff conducted site visits of all 26 office buildings. As part of managing the flow of ESPM and Asset Score data for the project, Earth Advantage, a sub-recipient of the Cities-LEAP award, created a DOE Standard Energy Efficiency Data (SEED) (USDOE 2018) instance for the City and used Asset Score’s Application Programming Interface (API) (Asset Score 2018) capabilities to develop two new features in the SEED Platform™: (1) automated Asset Score Preview ranges calculated based on benchmarking data and the City’s estimate of number of building floors; and (2) storage of full Asset Score information. Leveraging the construction permit history and site visit information for the 26 office buildings, The Cadmus Group (Cadmus) analyzed benchmarking data and Asset Score information to identify opportunities and drivers to improve performance. Correlation and regression analysis of the combined dataset was completed to determine whether building operations or specific systems – mechanical, lighting or envelope – present the best opportunities to improve energy performance. The central outcome of this project was Cadmus’ detailed analysis of the richer dataset that was created by combining the City of Portland’s commercial building permit activity and building-specific energy performance information based on metrics from ESPM and Asset Score Tool. Some of their findings collaborate with well-known facts, such as buildings with less efficient lighting systems are good targets for efficiency improvements through lighting upgrades. This analysis also helped identify that individual heating, ventilation, and air conditioning (HVAC) equipment efficiency does not necessarily correlate with building performance. However, overall HVAC system performance, as measured with the Total System Performance Ratio (TSPR) metric, is a better indicator of building performance (Goel et al. 2014). As a metric, TSPR considers whole system performance that includes equipment efficiency and system controls, such as resets for static pressure and chilled water setpoints, which can be more effective and financially feasible options for improving building performance. Given the high cost associated with envelope retrofits, opportunities to upgrade envelope insulation are likely to be limited. However, buildings with single-pane and non-thermal break windows are good candidates for window replacements, such as upgrading to double-pane windows with thermal breaks. This research project determined that developing Asset Scores based on site visits is preferable to mining City building permit data. In addition, the use of benchmarking data to develop Asset Score Preview Scores is recommended as a first step in engaging building managers to develop full Asset Scores. Asset Score Tool outputs can help building managers quickly identify opportunities for improvement and then work with the utility incentive administrator and energy service providers to develop their retrofit plan. Where full Asset Scores are available, analysis using a quadrant matrix with ENERGY STAR scores is recommended to identify buildings that present the best opportunities for operational-behavioral improvements versus ones with opportunities for upgrades to physical building systems. This workflow and the tools will help cities, utility incentive administrators, building portfolio managers and energy service providers develop energy programs and strategies for screening and analysis of buildings with the greatest energy savings potential. This report describes the project approach and research results to inform future coordination of ESPM and Asset Score data, including the use of benchmarking data to generate Preview scores. Given better awareness of energy performance, building managers can make more informed decisions to reduce energy consumption and carbon emissions. With cities, states and jurisdictions adopting benchmarking and auditing ordinances, there are substantial amounts of data submitted to cities that could be used to inform investments in energy efficiency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Patience is a virtue: A data-driven analysis of rooftop solar PV permitting timelines in the United States

© 2020 The Authors Local permitting can ensure the safe installation and operation of rooftop solar photovoltaic (PV) systems. At the same time, burdensome local permitting processes and local variation in requirements may pose challenges to PV deployment. In this article, we explore new data on the durations between key steps in the PV permitting process in the United States. The data suggest that a typical customer can expect to wait around 25–100 days from permit application until an installed system passes inspection. Permit durations vary significantly across jurisdictions, due in part to differences in local permitting policies. However, permit durations vary as significantly within jurisdictions as across them, in part due to significant variation across installers, suggesting that installer strategies and practices play an important role in permitting timelines. Permit durations have declined over time, reflecting progress from permit streamlining policies and jurisdiction learning-by-doing, though durations have stabilized in recent years. The data suggest that typical PV customers still face long and uncertain permitting timelines in the United States.

O'Shaughnessy, E↗

Class 1 Permit Modification Notification Addition of Structures within Technical Area 54, Area G, Pad 11, Dome 375 Los Alamos National Laboratory Hazardous Waste Facility Permit, July 2012

The purpose of this letter is to notify the New Mexico Environment Department-Hazardous Waste Bureau (NMED-HWB) of a Class 1 Permit Modification to the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit issued to the Department of Energy (DOE) and Los Alamos National Security, LLC (LANS) in November 2010. The modification adds structures to the container storage unit at Technical Area (TA) 54 Area G, Pad 11. Permit Section 3.1(3) requires that changes to the location of a structure that does not manage hazardous waste shall be changed within the Permit as a Class 1 modification without prior approval in accordance with Code of Federal Regulations, Title 40 (40 CFR), {section}270.42(a)(1). Structures have been added within Dome 375 located at TA-54, Area G, Pad 11 that will be used in support of waste management operations within Dome 375 and the modular panel containment structure located within Dome 375, but will not be used as waste management structures. The Class 1 Permit Modification revises Figure 36 in Attachment N, Figures; and Figure G.12-1 in Attachment G.12, Technical Area 54, Area G, Pad 11 Outdoor Container Storage Unit Closure Plan. Descriptions of the structures have also been added to Section A.4.2.9 in Attachment A, TA - Unit Descriptions; and Section 2.0 in Attachment G.12, Technical Area 54, Area G, Pad 11 Outdoor Container Storage Unit Closure Plan. Full description of the permit modification and the necessary changes are included in Enclosure 1. The modification has been prepared in accordance with 40 CFR {section}270.42(a)(l). This package includes this letter and an enclosure containing a description of the permit modification, text edits of the Permit sections, and the revised figures (collectively LA-UR-12-22808). Accordingly, a signed certification page is also enclosed. Three hard copies and one electronic copy of this submittal will be delivered to the NMED-HWB.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Request for a Class 1 Permit Modification to the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit, EPA ID No. NM0890010515

The following submittal has been prepared by the U.S. Department of Energy and Los Alamos National Security, LLC (collectively the Permittees) to request a modification to the November 2010 Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit (Permit). This modification has been prepared as a Class 1 permit modification requiring prior approval by the New Mexico Environment Department-Hazardous Waste Bureau (NMEDHWB) (also known as a Class 1* permit modification) as described in the New Mexico Administrative Code, Title 20, Chapter 4, Part 1 (20.4.1.900 NMAC) [incorporating Code of Federal Regulations (CFR), Title 40 §§ 270.42 (a) ]. LANL’s Environmental Protection Agency (EPA) identification number is EPA ID No. NM0890010515. The permit modification includes revisions to Table K-1, SWMUs (Solid Waste Management Units) and AOCs (Areas of Concern) Requiring Corrective Action, which is included in Permit Attachment K, Listings of SWMUs and AOCs. The following summary describes the proposed modification and rationale behind the modification and contains a revised version of the relevant page of Table K-1 incorporating the modification (Attachment 1). The Permittees request that the revised Table K-1 be included in the Permit by the NMED-HWB upon approval of this permit modification request.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Request for a Class 1 Permit Modification to the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit, Attachment K EPA ID No. NM0890010515 (Rev. 1)

The following submittal has been prepared by the U.S. Department of Energy and Los Alamos National Security, LLC (collectively the Permittees) to request a modification to the November 2010 Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit (Permit). This modification has been prepared as a Class 1 permit modification requiring prior approval by the New Mexico Environment Department-Hazardous Waste Bureau (NMEDHWB) (also known as a Class 1 * permit modification) as described in the New Mexico Administrative Code, Title 20, Chapter 4, Part 1 (20.4.1.900 NMAC) [incorporating Code of Federal Regulations (CFR), Title 40 §§ 270.42 (a) ]. LANL's Environmental Protection Agency (EPA) identification number is EPA ID No. NM0890010515. The permit modification includes revisions to Table K-l , SWMUs (Solid Waste Management Units) and AOCs (Areas of Concern) Requiring Corrective Action, which is included in Permit Attachment K, Listings ofSWMUs and AOCs. The following summary describes the proposed modification and rationale behind the modification and contains a revised version of the relevant page of Table K-l incorporating the modification (Attachment 1). The Permittees request that the revised Table K-I be included in the Permit by the NMED-HWB upon approval of this permit modification request. Pits 38 (AOC 54-023) and 39 (AOC 54-024) were recently designated as areas of concern (AOCs) and shall be included in Table K-l of Attachment K, Listings ofSWMUs and AOCs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Notification of General Class 1 Permit Modification for the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit, EPA ID # NM0890010515

This document contains a notification for a Class 1 Permit Modification to modify the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit (Permit). The text modifications are provided herein and have been made to the Permit by the Department of Energy (DOE) and Los Alamos National Security, LLC (LANS), collectively the Permittees. The modifications to the text of the Permit have been identified using red text and red lines through the texts for deletions. Description: This modification includes three changes. One change includes an address change within the Attachment D, Contingency Plan, and the remaining changes correct two typographical errors in Permit Section 2.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Notification of Class 1 Permit Modification to Attachment B, Part A Application for the Los Alamos National Laboratory Hazardous Waste Facility Permit, EPA ID # NM0890010515

This document contains a notification for a Class 1 Permit Modification to modify the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit (Permit) issued to the Department of Energy and the Los Alamos National Security, LLC, collectively known as the Permittees, in November 2010. All changes have been made to Attachment B, Part A Application, and a full, updated form, Revision 10.0, is enclosed. The modification updates the facility contact and address information, and the process codes and design capacity section for Technical Area (TA) 14; TA-16; TA-39; TA-54 West; TA-54, Area G; and TA-55 within the Attachment B, Part A Application. The process codes and design capacity section for TA-14, TA-16, and TA-39 was updated to incorporate a statement that the Permittees have notified of the intent to close units at these locations. The process design capacity for TA-54, Area G has been updated from 3,664,150 gallons to 4,346,590 gallons to account for the TA-54, Area G Pad 11 container storage unit that was added when the Permit was issued in 2010 but at the time did not previously store hazardous waste. The number of units at TA-54, Area G was also updated to 9 units to include this new unit. The process design capacity for TA-55 has also been updated from 178,500 gallons to 207,600 gallons to incorporate the addition of the TA-55-185 container storage unit that was also added when the Permit was issued. The number of storage units at TA-55 was updated to 7 to include the unit. The process design capacity at TA-54 West was changed to 11,660 gallons to correct a typographical error in previous versions of the form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of convection‐permitting model simulations of cloud populations associated with the Madden‐Julian Oscillation using data collected during the AMIE/DYNAMO field campaign

Abstract Regional convection‐permitting model simulations of cloud populations observed during the 2011 Atmospheric Radiation Measurement (ARM) Madden‐Julian Oscillation Investigation Experiment/Dynamics of the Madden‐Julian Oscillation Experiment (AMIE/DYNAMO) field campaign are evaluated against ground‐based radar and ship‐based observations. Sensitivity of model simulated reflectivity, surface rain rate, and cold pool statistics to variations of raindrop breakup/self‐collection parameters in four state‐of‐the‐art two‐moment bulk microphysics schemes in the Weather Research and Forecasting (WRF) model is examined. The model simulations generally overestimate reflectivity from large and deep convective cells, and underestimate stratiform rain and the frequency of cold pools. In the sensitivity experiments, introduction of more aggressive raindrop breakup or decreasing the self‐collection efficiency increases the cold pool occurrence frequency in all of the simulations, and slightly reduces the reflectivity and precipitation statistics bias in some schemes but has little effect on the overall mean surface precipitation. Both the radar observations and model simulations of cloud populations show an approximate power law relationship between convective echo‐top height and equivalent convective cell radius.

Hagos, Samson↗

E-Tunnel wastewater discharge permit quarterly monitoring report. Water pollution control permit Nev 96021, third quarter 2020

Monitoring and sampling activities are performed at the E-Tunnel Wastewater Disposal System (ETDS ) in accordance with the requirements of Water Pollution Control (WPC) Permit NEV 96021, Revision 1, which is effective October 1, 2013. Although the end date of the WPC permit is September 30, 2018, the Nevada Division of Environmental Protection (NDEP), in a letter dated September 21, 2018, provided guidance that indicated the WPC Permit NEV 96021, Revision 1, is in effect until NDEP notifies the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office otherwise. This QMR includes the results of monthly inspections and monitoring for July, August, and September 2020. Monthly inspections and monitoring were conducted on July 21, August 19, and September 16, 2020. Inspections include a visual assessment of the berms, ponding, water levels relative to the overflow pipes, tunneling or burrowing into the berms, soil conditions on and around the berms, erosion or sloughing of the slopes of the berms, seeps at the toe of the berms, deep-rooting botanicals on the berms, and fencing. Monthly monitoring includes measurement s of the instantaneous flow rate, hydrogen ion activity (pH), and specific conductance of the ETDS discharge. The report will be submitted to the State of Nevada.

54 ENVIRONMENTAL SCIENCES↗

PERMITTING OF A PROJECT INVOLVING HYDROGEN: A CODE OFFICIAL’S PERSPECTIVE

Recent growth in the development of hydrogen infrastructure has led to more requests for code officials to approve hydrogen-related projects and facilities. To help expedite the review and approval process, significant efforts have been made to educate code officials on permitting hydrogen vehicle fueling stations and facilities using stationary fuel cells (e.g., backup power for telephone cell tower sites). Despite these efforts, project delays continue because of several factors, including the limited experience of code officials with these types of facilities, submittals that lack the required information (including failure to adequately address local requirements), and submission of poor quality documents. The purpose of this paper is to help project proponents overcome these potential roadblocks and obtain timely approval for a project. A case study of an actual stationary application permitting request is provided to illustrate the value of addressing these issues.

Kallman, Richard A.↗

Impacts of aerosols on seasonal precipitation and snowpack in California based on convection-permitting WRF-Chem simulations

Here, a version of the WRF-Chem model with fully coupled aerosol–meteorology–snowpack is employed to investigate the impacts of various aerosol sources on precipitation and snowpack in California. In particular, the impacts of locally emitted anthropogenic and dust aerosols, and aerosols transported from outside California are studied. We differentiate three pathways of aerosol effects: aerosol–radiation interaction (ARI), aerosol–snow interaction (ASI), and aerosol–cloud interaction (ACI). The convection-permitting model simulations show that precipitation, snow water equivalent (SWE), and surface air temperature averaged over the whole domain (34–42° N, 117–124° W, not including ocean points) are reduced when aerosols are included, therefore reducing large biases in these variables due to the absence of aerosol effects in the model. Aerosols affect California water resources through the warming of mountaintops and the reduction of precipitation; however, different aerosol sources play different roles in changing surface temperature, precipitation, and snowpack in California by means of various weights of the three pathways. ARI by all aerosols mainly cools the surface, leading to slightly increased SWE over the mountains. Locally emitted dust aerosols warm the surface of mountaintops through ASI, in which the reduced snow albedo associated with dusty snow leads to more surface absorption of solar radiation and reduced SWE. Transported aerosols and local anthropogenic aerosols play a dominant role in increasing nonprecipitating clouds but reducing precipitation through ACI, leading to reduced SWE and runoff on the Sierra Nevada, as well as the warming of mountaintops associated with decreased SWE and hence lower surface albedo. The average changes in surface temperature from October 2012 to June 2013 are about –0.19 and 0.22 K for the whole domain and over mountaintops, respectively. Overall, the averaged reduction during October to June is about 7 % for precipitation, 3 % for SWE, and 7 % for surface runoff for the whole domain, while the corresponding numbers are 12, 10, and 10 % for the mountaintops. The reduction in SWE is more significant in a dry year, with 9 % for the whole domain and 16 % for the mountaintops. The maximum reduction of ~20 % in precipitation occurs in May and is associated with the maximum aerosol loading, leading to the largest decrease in SWE and surface runoff over that period. It is also found that dust aerosols can cause early snowmelt on the mountaintops and reduced surface runoff after April.

54 ENVIRONMENTAL SCIENCES↗

RCRA Permit for a Hazardous Waste Management Facility, Permit Number NEV HW0101: Calendar Year 2016 (Annual Summary/Waste Minimization Report)

This report summarizes the EPA identification number of each generator from which the Permittee received a waste stream, a description and quantity of each waste stream in tons and cubic feet received at the facility, the method of treatment, storage, and/or disposal for each waste stream, a description of the waste minimization efforts undertaken, a description of the changes in volume and toxicity of waste actually received, any unusual occurrences, and the results of tank integrity assessments. This Annual Summary/Waste Minimization Report is prepared in accordance with Section 2.13.5 of Permit Number NEV HW0101.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RCRA Permit for a Hazardous Waste Management Facility, Permit Number NEV HW0101: Annual Summary/Waste Minimization Report: Calendar Year 2013

This report summarizes the EPA identification number of each generator from which the Permittee received a waste stream, a description and quantity of each waste stream in tons and cubic feet received at the facility, the method of treatment, storage, and/or disposal for each waste stream, a description of the waste minimization efforts undertaken, a description of the changes in volume and toxicity of waste actually received, any unusual occurrences, and the results of tank integrity assessments. This Annual Summary/Waste Minimization Report is prepared in accordance with Section 2.13.3 of Permit Number NEV HW0101.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RCRA Permit for a Hazardous Waste Management Facility Permit Number NEV HW0101, Annual Summary/Waste Minimization Report, Calendar Year 2015, Nevada National Security Site, Nevada

This report summarizes the EPA identification number of each generator from which the Permittee received a waste stream, a description and quantity of each waste stream in tons and cubic feet received at the facility, the method of treatment, storage, and/or disposal for each waste stream, a description of the waste minimization efforts undertaken, a description of the changes in volume and toxicity of waste actually received, any unusual occurrences, and the results of tank integrity assessments. This Annual Summary/Waste Minimization Report is prepared in accordance with Section 2.13.5 of Permit Number NEV HW0101.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exposing Process‐Level Biases in a Global Cloud Permitting Model With ARM Observations

The emergence of global convective‐permitting models (GCPMs) represents a significant advancement in climate modeling, offering improved representation of deep convection and complex precipitation patterns. In this study, we evaluate the performance of the Simple Cloud‐Resolving E3SM Atmosphere Model (SCREAM) using its doubly periodic configuration (DP‐SCREAM) against large eddy simulations and modern observational data sets from the Atmospheric Radiation Measurement program. We introduce several new transitional cloud regime cases, such as the transition from shallow to deep convection and from stratocumulus to cumulus, as well as cold‐air outbreak scenarios. The results reveal both strengths and limitations of SCREAM, particularly in the accurate simulation of cloud transitions and midlevel convection, with varying degrees of sensitivity to horizontal and vertical resolution. Despite improvements at higher resolutions, key biases remain, including the abrupt transition from shallow to deep convection and the lack of congestus clouds. These findings underscore the need for further refinement in turbulence parameterizations and vertical grid resolution in GCPMs.

Bogenschutz, Peter A. [Lawrence Livermore National↗

An Optimized Parameterization of Sub‐Grid Scale Advection for Convection Permitting Models

Convection‐permitting models (CPMs) explicitly resolve deep convection yet under‐resolve the organized lateral exchanges among drafts and their environment that control entrainment/detrainment, precipitation efficiency, and mesoscale structure. In this work, we introduce the Optimized Advection Scheme (OAS), which introduces a small rotation of the Cartesian frame of reference for the horizontal winds relative to other variables used in advection that induces cross‐gradient transport to mimic under‐resolved convective mixing. The rotation angle is selected to minimize the Kullback–Leibler divergence between the simulated and satellite observed precipitation intensity distributions, yielding a physically consistent perturbation that is computationally inexpensive and portable. Optimized Advection Scheme is implemented in WRF and evaluated over Amazon (April 2014). It shifts precipitation–precipitable‐water joint distributions toward lighter rain, reduces overly intense rates, and improves mesoscale convective system (MCS) lifetime and propagation. Mechanistically, the added cross‐gradient transport promotes convective detrainment and environmental mixing, which cools and moistens the mid‐troposphere, weakens downward momentum transport, alleviates excessive downwelling shortwave biases, and warms the surface temperature. The optimized rotation angle yields comparable improvements at 4‐km and 1‐km grid spacing, demonstrating resolution‐independent benefits across the CPM gray zone. By targeting the dynamical root of under‐mixed convective circulations, rather than tuning model microphysics or closures, OAS delivers robust, scale‐aware improvements in precipitation statistics, cloud vertical structure, and characteristics of MCS (MCSs), offering a practical pathway to more reliable CPM simulations for weather and climate applications.

CPM↗