Direct Phase-Angle Detection for Three-Phase Inverters in Asymmetrical Power Grids

This paper introduces a signal reformation based direct phase-angle detection (DPD-SR) technique for three-phase inverters supporting asymmetrical grids. Asymmetries in three-phase systems may happen because of unbalanced three-phase loads, which can lead to the voltage asymmetry at the terminals of grid-tied inverters. The proposed DPD-SR technique can detect the voltage phase-angle under asymmetrical conditions. The DPD-SR technique also offers precise and rapid phase-angle detection via signal reformation and trigonometric functions. In essence, the phase-angle detection is directly derived from the trigonometric properties of the line-line voltages, while signal reformation is implemented to handle asymmetrical voltages. The proposed method measures two line-line voltages and detects the phase-angle of a three-phase system under both symmetrical and asymmetrical conditions. Unlike classical phase-locked loop (PLL) techniques, DPD-SR does not need any closed-loop PI controller, which significantly reduces the complexity and the delay in detecting the phase-angle. In this paper, the efficacy of the proposed technique is examined in comparison with the state-of-the-art PLLs under asymmetrical conditions via a set of laboratory experiments. Here, the performance of the phase-angle detection is also tested as part of an inverter feeding an asymmetrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Alignment Method for Synchronized Phase Angle Measurement With Presence of Practical Time Shift

Synchronized Phase Angle Measurements (SPAMs) are widely used in power systems in the applications of situational awareness. However, the practical time shifts can lead to unexpected angle differences among Phasor Measurement Units (PMUs) manufactured from various vendors. Moreover, since most of PMUs calculate phase angle via Discrete Fourier Transform based approaches, this issue becomes even worse under the off-nominal frequency condition. To mitigate the impact of practical timing shift, this letter presents a fast method to rectify the SPAM for appropriate alignment. To verify the performance of the proposed method, laboratory and field tests have been conducted by implementing the method in PMUs and phasor data concentrators, respectively. The results demonstrate that the standard deviations of the phase angle differences have significantly decreased to 0.1$^{\circ }$ order with the adoption of the proposed method.

42 ENGINEERING↗

Timestamp Shift Detection for Synchrophasor Data Based on Similarity Analysis between Relative Phase Angle and Frequency

Timestamp Shift (TS) in synchrophasor data can lead to false operation of synchrophasor-based wide-area monitoring, protection and control applications. The letter presents a method to detect TS of synchrophasor data based on similarity analysis between its own relative phase angle and frequency. Here, a linear correlation component, caused by TS, between relative phase angle and measured frequency is discovered via theoretical derivation. Then a detection method is developed utilizing this linear component for TS diagnosis. Firstly, system phase angle is leveraged as angle reference and then relative phase angle is calculated. Secondly, the correlation coefficient between relative phase angle and frequency is calculated for similarity analysis. Thirdly, the TS is detected via threshold criterion and corresponding time error is estimated. The effectiveness of this method is validated via experiments with actual synchrophasor data in FNET/Grideye.

97 MATHEMATICS AND COMPUTING↗

Timestamp Error Detection and Estimation for PMU Data based on Linear Correlation between Relative Phase Angle and Frequency

Time synchronization is essential to synchro-phasor-based applications. However, Timestamp Error (TE) in synchrophasor data can result in application failures. This paper proposes a method for TE detection based on the linear correlation between frequency and relative phase angle. The TE converts the short-term relative phase angle from noise-like signal to one that linear with the frequency. Pearson Correlation Coefficient (PCC) is applied to measure the linear correlation and then detect the timestamp error. The time error is estimated based on the variation of frequency and relative phase angle. Case studies with actual synchrophasor data demonstrate the effectiveness of TE detection and excellent accuracy of TE estimation.

Yu, Wenpeng↗

Real-Time Detection and Localization of Line Trip Event Via Relative Phase Angles

Line trip events widely exist in power systems. They can result in power outages and a huge economic loss if not promptly detected and localized. To provide a fast and precise solution, this paper presents a Complete Coverage of Voltage Measurement (CCVM)-based line trip event detection algorithm and a Relative Phase Angle (RPA)-based line trip event localization algorithm. First, frequency and relative phase angle features during a line trip event are calculated. Then, the CCVM-based algorithm is proposed from both frequency and rate of change of frequency estimation algorithm aspects. Additionally, the RPA-based algorithm is presented, and two cases are studied to demonstrate the uniqueness of the proposed algorithm. Various experiments are conducted, where the simulation results demonstrate that the proposed CCVM-based algorithm can detect a line trip event as short as 2.07 ms. In addition, the RPA-based algorithm has 1.26 times higher localization accuracy compared with the frequency magnitude-based and phase angle-based algorithms. In conclusion, the experiment results on the examples from two interconnected power systems in the U.S. verified the performance of the proposed algorithms in wide-area power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a correlation reflectometer radiometer diagnostic and measurements of the electron density–temperature cross-phase angle in the H-mode pedestal with small edge localized modes at ASDEX Upgrade

This work presents the hardware design and first results from a newly commissioned correlation reflectometer radiometer diagnostic that measures the cross-phase angle between electron density and temperature fluctuations in ASDEX Upgrade plasmas. This diagnostic employs cross correlations between signals measured by a tunable, continuous wave, perpendicular incidence, fluctuation reflectometer, and a 24-channel radiometer sharing the same line of sight. Novel measurements in the pedestal of a helium H-mode plasma with small edge localized modes show changes in the cross-phase angle between the electron density and temperature fluctuations from ∼90° to 120°, suggesting changes in the properties of the turbulence driving transport in the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Matrix converter operating in current control mode using feed forward signals

A matrix converter system having a current control mode operation is provided. The system includes a matrix converter having a switching matrix. The matrix converter is coupled at its low-voltage side to a generator and at its output load side to a load. A controller having a pulse width modulation (PWM) control circuit is configured to control the matrix converter via its switching matrix to increase energy within the internal inductances of the generator when the switching matrix causes a short circuit. A feed forward calculator is configured to calculate a feed forward output phase angle. The feed forward output phase angle is an estimation of an angle between an output current vector and an output voltage vector that represent feedback signals of current and voltage output by the matrix converter. The angular position of the voltage output vector is adjusted as a function of the feed forward output phase angle to align angular position or phase angle of the voltage output vector that represents the voltage output with a selected angular position or phase angle.

42 ENGINEERING↗

Absolute colors and phase coefficients of asteroids

Context: We use the phase curves of small bodies to measure absolute magnitudes and, together with complementary theoretical and laboratory results, to understand the micro- and macroscopic properties of their surfaces. Although we can observe asteroids up to phase angles of about 30 deg, the range of phase angles covered by outer Solar System objects usually does not go further than 7-10 deg for centaurs and 2 deg for trans-Neptunian objects, and a linear relation between magnitude and phase angle may be assumed. Aims: We aim to directly compare data taken for objects in the inner Solar System (inside the orbit of Jupiter) with data for centaurs and trans-Neptunian objects. Methods: We use the SLOAN Moving Objects Catalog (MOC) data to construct phase curves restricted to phase angles of less than or equal to 7.5 deg, which is compatible with the angles observed for the trans-Neptunian and Centaur population. We assume a linear model for the photometric behavior to obtain absolute magnitudes and phase coefficients in the ugirz, V, and R filters. Results: We obtain absolute magnitudes in seven filters for over 4000 objects. Our comparison with outer Solar System objects suggests the surfaces have a common property: intrinsically redder objects become blue with increasing phase angle, while the opposite happens for intrinsically bluer objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and validation of an automatic method to detect the latest contracting viable left ventricular segments to assist guide CRT therapy from gated SPECT myocardial perfusion imaging

Objectives: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. Methods: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. Results: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. Conclusions: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cooperative Inverters to Overcome PLL Malfunctions

This paper presents a cooperative strategy between smart inverters to overcome instability and undesired trips of inverters caused by Phase-Locked Loop (PLL) malfunctions. For the grid-interactive inverter, PLL is typically required to measure the phase angle of the AC voltage at the Point of Common Coupling (PCC) of the inverter. Accurate phase-angle measurement is critical for grid-interactive inverters to stay synchronized with the power grid. If the inverters are interconnected through a communication link, they can support each other by sharing their grid information, such as phase-angles at their PCCs. The cooperative strategy utilizes the phase-angles and voltages at PCCs in a neighborhood to identify any possible PLL malfunctions or measurement inaccuracies and then enable the inverters to make corrective decisions. The efficacy of the cooperative strategy has been verified through simulation results in MATLAB/Simulink environment in this paper.

Sadeque, Fahmid↗

A Universal Controller for Grid-Forming Inverters in Microgrid during Islanding for Low Transient Current

This paper presents a universal controller to reduce the transient current during islanding of microgrid. In the proposed universal controller, two sets of semi-parallel paths are formed, where one set produces voltage and phase-angle references for the grid-following (GFL) mode, and the other set produces the voltage and phase-angle references for the grid-forming (GFM) mode of operation for the inverters. Herein, the controller enables an inverter to universally operate in GFL and GFM mode, whereas, only one set of voltage and phase-angle reference is engaged for PWM signal generation. When the microgrid is disconnected from the grid, the universal controller switches the voltage and phase-angle references from GFL to GFM mode. The proposed controller ensures lower transient current by keeping the two sets of semi-parallel paths synchronized throughout the operation of the inverter and enabling seamless transition between the modes. The proposed controller is verified through hardware experiments under different scenarios in a laboratory scale microgrid for inverters transitioning from GFL to GFM mode after islanding.

Sadeque, Fahmid↗

Method for independent real and reactive power flow control using locally available parameters

A method for independent real and reactive power flow control without sensing receiving end voltage in a power flow controller (PFC) includes calculating a first reference phase angle, calculating a first reference voltage, modifying the first reference phase angle calculated using a first phasor modifier, calculating a first reference current for a first terminal, calculating a second reference phase angle for current through the first terminal, calculating a second reference voltage across a second CMI by subtracting voltages at the first terminal and a second terminal, and controlling the first CMI and the second CMI for controlling the power flow through the PFC.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Matrix converter operation in current control mode with regulation of output voltage vector

A matrix converter system having a current control mode operation is provided. The matrix converter system includes a matrix converter that includes a plurality of switches. A unity current reference vector having an amplitude of one is determined that defines an angle and frequency of an output current vector as a function of a reference phase angle, which is a function of the output current vector and an output voltage vector representing feedback signals of a multiphase signal output to a load. The unity current reference vector is used to control the matrix converter, to cause the output current vector to be aligned with the unity current reference vector. A unity voltage reference vector having an amplitude of one is provided that defines a reference angle and frequency as a function of a zero phase angle. The output voltage vector and the unity voltage reference vector are aligned to determine the reference phase angle as an angle between the aligned output voltage vector and the output current vector.

42 ENGINEERING↗

Isotope effects on energy transport in the core of ASDEX-Upgrade tokamak plasmas: Turbulence measurements and model validation

Design and operation of future tokamak fusion reactors using a deuterium–tritium 50:50 mix requires a solid understanding of how energy confinement properties change with ion mass. This study looks at how turbulence and energy transport change in L-mode plasmas in the ASDEX Upgrade tokamak when changing ion species between hydrogen and deuterium. For this purpose, both experimental turbulence measurements and modeling are employed. Local measurements of ion-scale (with wavevector of fluctuations perpendicular to the B-field k⊥< 2 cm−1, k⊥ρs< 0.2, where ρs is the ion sound Larmor radius using the deuterium ion mass) electron temperature fluctuations have been performed in the outer core (normalized toroidal flux ρTor=0.65−0.8) using a multi-channel correlation electron cyclotron emission diagnostic. Lower root mean square perpendicular fluctuation amplitudes and radial correlation lengths have been measured in hydrogen vs deuterium. Measurements of the cross-phase angle between a normal-incidence reflectometer and an ECE signal were made to infer the cross-phase angle between density and temperature fluctuations. The magnitude of the cross-phase angle was found larger (more out-of-phase) in hydrogen than in deuterium. TRANSP power balance simulations show a larger ion heat flux in hydrogen where the electron-ion heat exchange term is found to play an important role. These experimental observations were used as the basis of a validation study of both quasilinear gyrofluid trapped gyro-Landau fluid-SAT2 and nonlinear gyrokinetic GENE codes. Linear solvers indicate that, at long wavelengths (k⊥ρs<1), energy transport in the deuterium discharge is dominated by a mixed ion-temperature-gradient (ITG) and trapped-electron mode turbulence while in hydrogen transport is exclusively and more strongly driven by ITG turbulence. The Ricci validation metric has been used to quantify the agreement between experiments and simulations taking into account both experimental and simulation uncertainties as well as four different observables across different levels of the primacy hierarchy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Practical Event Location Estimation Algorithm for Power Transmission System Based on Triangulation and Oscillation Intensity

Event location in power systems is quite essential information for system operators to enhance control-room situational awareness capability. Therefore, it is of great importance to develop an event location estimation algorithm for transmission systems with high accuracy. With the development of wide-area measurement system (WAMS) such as FNET/GridEye, and the synchrophasor measurement devices (SMDs) such as frequency disturbance recorders (FDRs), the synchronous measurement data including frequency, voltage amplitude and phase angle can be collected and used for event location estimation. First, the phase angle and rate of change of frequency (RoCoF) trajectories are respectively used for determining two sets of wave arrival time associated with each FDR. Then, a convolutional neural network (CNN) is utilized to determine the wave arrival order to select the more suitable set of wave arrival times for a given case and to perform corresponding modifications. Next, the oscillation intensity associated with each FDR is determined based on phase angle trajectories in the center of inertia (COI) coordinate system. Finally, the multiple criteria for event location estimation are represented. In conclusion, case studies and comparisons between the proposed and previous algorithms using actual and confirmed cases in U.S. power systems are performed to demonstrate the effectiveness and improvement of the proposed algorithm in practical applications.

frequency disturbance recorder (FDR)↗