Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOELASTICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Establishment of a strain analysis capability using photoelastic coatings

In accordance with the Research Plan prepared at the beginning of the Fellowship Program, the summer activities consisted of: training the personnel of the Structural Test Division of the Structures and Dynamics Laboratory in the theory and practice of strain analysis using photoelastic coatings; and performing strain analysis using photoelastic coatings on appropriate test articles. In support of these activities, the following actions were taken: (1) equipment and supplies necessary for strain analysis using photoelastic coatings were specified, purchased, and checked out; (2) four engineers were trained in the theory and practice of strain analysis using photoelastic coatings; (3) four technicians were trained in the practice of preparing and applying photoelastic coatings to both curved and flat surfaces; (4) in addition to the final program seminar, three seminars on the fundamentals and use of photoelastic coatings were presented to a total of 43 members of the various laboratories at MSFC; (5) a photoelastic coating was applied to and used in a test of a thrust vector control corner section; (6) to further assist the engineers with the use and understanding of photoelastic coatings, fifteen journal articles were located and copied, and camera settings for photographic fringe patterns were determined and recorded; and (7) two proposals for providing technical assistance in strain analysis at MSFC and testing of selected components/assemblies at the University of Alabama in Tuscaloosa were written for submission to NASA.

Gambrell, Samuel C., Jr.↗

Photoelastic tests on models of thermal protection system for space shuttle orbiter

The thermal protection system (TPS) of the space shuttle orbiter vehicle, consisting of ceramic tile/adhesive/strain isolator pad/adhesive/aluminum substructure, was modeled photoelasticity. A highly sensitive photoelastic material was used in the models to show the nature of the stress-transfer between the strain isolation pad (SIP) and the ceramic tile through the RTV-adhesive layer. Isochromatic fringe patterns were obtained for models subjected to tension and combined tension and bending. Tests indicated that the load-transfer between the SIP and the photoelastic material occurred at discrete locations causing stress concentrations in the photoelastic material. Stress concentration factors of the order of 1.9 were measured, but as the observed photoelastic response was an integrated effect through the model thickness, the local stress concentration factors at the SIP/tile interface could be even higher.

Prabhakaran, R.↗

Polarimetric Imaging using Two Photoelastic Modulators

A method of polarimetric imaging, now undergoing development, involves the use of two photoelastic modulators in series, driven at equal amplitude but at different frequencies. The net effect on a beam of light is to cause (1) the direction of its polarization to rotate at the average of two excitation frequencies and (2) the amplitude of its polarization to be modulated at the beat frequency (the difference between the two excitation frequencies). The resulting modulated optical light beam is made to pass through a polarizing filter and is detected at the beat frequency, which can be chosen to equal the frame rate of an electronic camera or the rate of sampling the outputs of photodetectors in an array. The method was conceived to satisfy a need to perform highly accurate polarimetric imaging, without cross-talk between polarization channels, at frame rates of the order of tens of hertz. The use of electro-optical modulators is necessitated by a need to obtain accuracy greater than that attainable by use of static polarizing filters over separate fixed detectors. For imaging, photoelastic modulators are preferable to such other electrio-optical modulators as Kerr cells and Pockels cells in that photoelastic modulators operate at lower voltages, have greater angular acceptances, and are easier to use. Prior to the conception of the present method, polarimetric imaging at frame rates of tens of hertz using photoelastic modulators was not possible because the resonance frequencies of photoelastic modulators usually lie in the range from about 20 to about 100 kHz.

Wang, Yu↗

Calibration of photoelastic modulator based dichrometers: maintaining constant phase across the spectrum

Photoelastic modulators can alter the polarization state of a beam of ultraviolet, visible or infrared photons by means of periodic stress-induced differences in the refractive index of a transparent material that forms the optical element of the device and is isotropic in the absence of stress. Furthermore, they have found widespread application in instruments that characterize or alter the polarization state of a beam in fields as diverse as astronomy, structural biology, materials science and ultraviolet lithography for the manufacture of nano-scale integrated circuits. Measurement of circular dichroism, the differential absorption of left- and right circularly polarized light, and of strain-induced birefringence of optical components are major applications. Instruments using synchrotron radiation and photoelastic modulators with CaF 2 optical elements have extended circular dichroism measurements down to wavelengths of about 130 nm in the vacuum ultraviolet. Maintaining a constant phase shift between two orthogonal polarization states across a spectrum requires that the amplitude of the modulated stress be changed as a function of wavelength. For commercially available photoelastic modulators, the voltage that controls the amplitude of modulation required to produce a specified phase shift, which is a surrogate for the stress modulation amplitude, has been shown to be an approximately linear function of wavelength in the spectral region where the optical element is transparent. But, extrapolations of such straight lines cross zero voltage at a non-zero wavelength, not at zero-wavelength. For modulators with calcium fluoride and fused silica optical elements, the zero-crossing wavelength is always in the spectral region where the optical element of the modulator strongly absorbs the incident radiation, and at a wavelength less than the longest-wavelength apparent resonance deduced from experimental values of the refractive index fit to the Sellmeier equation. Using a model that relates the refractive indices of a stressed optical element to the refractive index of its unstressed state, an expression for the modulator control voltage was derived that closely fits the experimental data. Our result provides a theoretical rational for the apparently linear constant-phase programming voltage, and thus provides theoretical backing for the calibration procedure frequently used for these modulators. Lastly there are other factors that can influence the calibration of a photoelastic modulator, including temperature and atmospheric pressure, are discussed briefly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of two-dimensional transmission photoelastic models to study stresses in double-lap bolted joints

The stress distribution in two hole connectors in a double lap joint configuration was studied. The following steps are described: (1) fabrication of photoelastic models of double lap double hole joints designed to determine the stresses in the inner lap; (2) assessment of the effects of joint geometry on the stresses in the inner lap; and (3) quantification of differences in the stresses near the two holes. The two holes were on the centerline of the joint and the joints were loaded in tension, parallel to the centerline. Acrylic slip fit pins through the holes served as fasteners. Two dimensional transmission photoelastic models were fabricated by using transparent acrylic outer laps and a photoelastic model material for the inner laps. It is concluded that the photoelastic fringe patterns which are visible when the models are loaded are due almost entirely to stresses in the inner lap.

Hyer, M. W.↗

An assessment of the accuracy of orthotropic photoelasticity

The accuracy of orthotropic photoelasticity was studied. The study consisted of both theoretical and experimental phases. In the theoretical phase a stress-optic law was developed. The stress-optic law included the effects of residual birefringence in the relation between applied stress and the material's optical response. The experimental phase had several portions. First, it was shown that four-point bending tests and the concept of an optical neutral axis could be conveniently used to calibrate the stress-optic behavior of the material. Second, the actual optical response of an orthotropic disk in diametral compression was compared with theoretical predictions. Third, the stresses in the disk were determined from the observed optical response, the stress-optic law, and a finite-difference form of the plane stress equilibrium equations. It was concluded that orthotropic photoelasticity is not as accurate as isotropic photoelasticity. This is believed to be due to the lack of good fringe resolution and the low sensitivity of most orthotropic photoelastic materials.

Hyer, M. W.↗

Simultaneous elastic and photoelastic calibration of birefringent orthotropic model materials

Transmission photoelastic analysis of composite models has been shown in recent years to be a viable stress analysis method for composite structures. However, difficulties in the fabrication of the model materials require the development of efficient mechanical and optical calibration procedures. In this paper, the methods for measuring elastic and photoelastic constants of composites are briefly reviewed. Then a new method, utilizing a relatively small calibration specimen, is described. In this method, electrical resistance strain gauges are mounted at selected points of a half-plane model and photoelastic measurements and strain readings are simultaneously taken. The data are processed by a least-squares procedure to yield the elastic and photoelastic constants. Comparison of results obtained by the proposed method with the results from conventional tests shows good agreement.

Prabhakaran, R.↗

Optical properties and zero photoelastic constant of ns{sup 2}-type metal cation containing oxide glasses

Zero photoelasticity and the relevant optical properties in binary RO–SiO{sub 2} (R = Sn, Pb) and R′{sub 2}O{sub 3}–SiO{sub 2} (R′ = Sb, Bi) and ternary Bi{sub 2}O{sub 3}–B{sub 2}O{sub 3}–SiO{sub 2} glasses were systematically studied. The zero photoelastic silicate glass leads to zero stress-induced birefringence, providing application to an optical lens, a filter, a beam splitter, and a fiber optic sensor without stress-induced birefringence. In this study, a variety of zero photoelastic binary silicate and ternary borosilicate glasses with optical bandgaps of 3.1–3.9 eV containing highly polarized ns{sup 2}-type cations are reported.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Complete sets of elastic constants and photoelastic coefficients of pure and MgO-doped lithium niobate crystals at room temperature

This paper presents the results of ultrasonic measurements of LiNbO{sub 3} and LiNbO{sub 3}:MgO crystals. The tensors of piezoelectric coefficients, elastic stiffness constants, and elastic compliances are determined for both crystals at room temperature. Combining these data with the results of piezo-optical measurements, a complete set of photoelastic tensor coefficients is also calculated. Doping of LiNbO{sub 3} crystals by MgO does not lead to a considerable modification of their elastic and photoelastic properties. However, LiNbO{sub 3}:MgO is characterized by a considerably higher resistance with respect to powerful light radiation, making it promising for future application in acousto-optic devices that deal with superpowerful laser radiation. Presented here are the complete tensor sets of elastic constants and photoelastic coefficients of LiNbO{sub 3} and LiNbO{sub 3}:MgO crystals that may be used for a geometry optimization of acousto-optical interaction providing the best diffraction efficiency of acousto-optical cells made of these materials.

36 MATERIALS SCIENCE↗

Stress Analysis of Columns and Beam Columns by the Photoelastic Method

Principles of similarity and other factors in the design of models for photoelastic testing are discussed. Some approximate theoretical equations, useful in the analysis of results obtained from photoelastic tests are derived. Examples of the use of photoelastic techniques and the analysis of results as applied to uniform and tapered beam columns, circular rings, and statically indeterminate frames, are given. It is concluded that this method is an effective tool for the analysis of structures in which column action is present, particularly in tapered beam columns, and in statically indeterminate structures in which the distribution of loads in the structures is influenced by bending moments due to axial loads in one or more members.

BEAM-COLUMNS - STRESSES↗

Influence of the photoelastic effect on the thermal lensin a YLF crystal

The thermal lens in an YLF crystal is calculated taking into account the anisotropy of the thermal conductivity, elasticity, linear expansion, and refractive index. It is proved that the experimentally observed strong astigmatism of the thermal lens in YLF can be explained only taking into account the photoelastic effect. It is shown that, in an YLF crystal cut so that the optical axis lies in the plane of the rod face, the contribution to the thermal lens is made only by three photoelastic coefficients for the ordinary wave and only by two coefficients for the extraordinary wave. Using these five photoelastic coefficients as fitting parameters, all the known experimental data are quantitatively interpreted. (active media)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stress intensity estimates by a computer assisted photoelastic method

Following an introductory history, the frozen stress photoelastic method is reviewed together with analytical and experimental aspects of cracks in photoelastic models. Analytical foundations are then presented upon which a computer assisted frozen stress photoelastic technique is based for extracting estimates of stress intensity factors from three-dimensional cracked body problems. The use of the method is demonstrated for two currently important three-dimensional crack problems.

Smith, C. W.↗

Use of two-dimensional transmission photoelastic models to study stresses in double-lap bolted joints: Load transfer and stresses in the inner lap

The determination of the stress distribution in the inner lap of double-lap, double-bolt joints using photoelastic models of the joint is discussed. The principal idea is to fabricate the inner lap of a photoelastic material and to use a photoelastically sensitive material for the two outer laps. With this setup, polarized light transmitted through the stressed model responds principally to the stressed inner lap. The model geometry, the procedures for making and testing the model, and test results are described.

Hyer, M. W.↗

Measurement of the internal stress and electric field in a resonating piezoelectric transformer for high-voltage applications using the electro-optic and photoelastic effects

The high output voltages from piezoelectric transformers are currently being used to accelerate charged particle beams for x-ray and neutron production. Traditional methods of characterizing piezoelectric transformers (PTs) using electrical probes can decrease the voltage transformation ratio of the device due to the introduction of load impedances on the order of hundreds of kiloohms to hundreds of megaohms. Consequently, an optical diagnostic was developed that used the photoelastic and electro-optic effects present in piezoelectric materials that are transparent to a given optical wavelength to determine the internal stress and electric field. The combined effects of the piezoelectric, photoelastic, and electro-optic effects result in a time-dependent change the refractive indices of the material and produce an artificially induced, time-dependent birefringence in the piezoelectric material. This induced time-dependent birefringence results in a change in the relative phase difference between the ordinary and extraordinary wave components of a helium-neon laser beam. The change in phase difference between the wave components was measured using a set of linear polarizers. The measured change in phase difference was used to calculate the stress and electric field based on the nonlinear optical properties, the piezoelectric constitutive equations, and the boundary conditions of the PT. Maximum stresses of approximately 10 MPa and electric fields of as high as 6 kV/cm were measured with the optical diagnostic. Measured results were compared to results from both a simple one-dimensional (1D) model of the piezoelectric transformer and a three-dimensional (3D) finite element model. Measured stresses and electric fields along the length of an operating length-extensional PT for two different electrical loads were within at least 50 % of 3D finite element simulated results. Additionally, the 3D finite element results were more accurate than the results from the 1D model for a wider range of electrical load impedances under test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phased array performance evaluation with photoelastic visualization

New instrumentation and a widening range of phased array transducer options are affording the industry a greater potential. Visualization of the complex wave components using the photoelastic system can greatly enhance understanding of the generated signals. Diffraction, mode conversion and wave front interaction, together with beam forming for linear, sectorial and matrix arrays, will be viewed using the photoelastic system. Beam focus and steering performance will be shown with a range of embedded and surface targets within glass samples. This paper will present principles and sound field images using this visualization system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Zero photoelastic and water durable ZnO–SnO–P{sub 2}O{sub 5}–B{sub 2}O{sub 3} glasses

We report properties of zero birefringent xZnO–(67–x)SnO–(33–y)P{sub 2}O{sub 5}–y B{sub 2}O{sub 3} glasses, within 18.5 ≤ x ≤ 22 and y = 0, 3, and 10 mol. %. These compositions of boro-phosphate glasses provide both zero photoelastic constant (PEC) and improved water durability. x = 19 and y = 3 compositions show minimum PEC of −0.002 × 10{sup −12} Pa{sup −1}, which can contribute to candidate material for fiber current sensor devise without lead. The structures of zero photoelastic glasses were investigated by Raman scattering and nuclear magnetic resonance spectroscopies. Compositions of zero PEC glasses are explained by the empirical model proposed by Zwanziger et al. [Chem. Mater. 19, 286-290 (2007)].

36 MATERIALS SCIENCE↗

Photoelastic studies of advanced lap joint concept

Photoelasticity was introduced as a quantitative tool in the experimental stress analysis of anisotropic birefringent composite model materials. The investigation was divided into three parts: (1) separation of principal stresses or strains, (2) photoelastic calibration, and (3) development of model-prototype relations.

Prabhakaran, R.↗

Photoelastic techniques for the complete determination of stresses in composite structures

Three methods of photoelastic analysis are examined. The first method is an extension of the oblique incidence technique in which the model (or the light beam) is rotated about one of the material symmetry axes. In the second method, transmission and reflection photoelastic responses are combined. The third method requires the drilling of small holes and the determination of the fringe orders at selected points on the hole boundary. The three methods are applied to an orthotropic circular disk under diametral compression. Results are compared with strain gage data.

Prabhakaran, R.↗