Improving photoelectron counting and particle identification in scintillation detectors with Bayesian techniques
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
A statistical inversion method is proposed for the photon-photoelectron-counting statistics in quantum key distribution experiment. With the statistical viewpoint, this problem is equivalent to the parameter estimation for an infinite binomial mixture model. The coarse-graining idea and Bayesian methods are applied to deal with this ill-posed problem, which is a good simple example to show the successful application of the statistical methods to the inverse problem. Numerical results show the applicability of the proposed strategy. The coarse-graining idea for the infinite mixture models should be general to be used in the future.
We present a supervised learning method to perform photoelectron counting in PMT- based dark matter search experiments and show that it is possible to achieve better accuracy and precision compared to standard Bayesian statistics methods.
Large-scale optical neutrino and dark-matter detectors rely on large-area photomultiplier tubes (PMTs) for cost-effective light detection. The new R14688-100 8-inch PMT developed by Hamamatsu provides state-of-the-art timing resolution of around 1 ns (FWHM), which can help improve vertex reconstruction and enable Cherenkov and scintillation light separation in scintillation-based detectors. This PMT also provides excellent charge resolution, allowing for precision photoelectron counting and improved energy reconstruction. The Eos experiment is the first large-scale optical detector to utilize these PMTs. Here, in this manuscript, we present a characterization of the R14688-100 single photoelectron response, such as the transit-time spreads, the dark-rates, and the afterpulsing. The single photoelectron response measurements are performed for the 206 PMTs that will be used in Eos.
The Anti Coincidence Detector (ACD) on the Fermi Gamma Ray Space Telescope provides charged particle rejection for the Large Area Telescope (LAT). We use two calibrations used by the ACD to conduct three studies on the performance of the ACD. We examine the trending of the calibrations to search for damage and find a timescale over which the calibrations can be considered reliable. We also calculated the number of photoelectrons counted by a PMT on the ACD from a normal proton. Third, we calculated the veto efficiencies of the ACD for two different veto settings. The trends of the calibrations exhibited no signs of damage, and indicated timescales of reliability for the calibrations of one to two years. The number of photoelectrons calculated ranged from 5 to 25. Large errors in the effect of the energy spectrum of the charged particles caused these values to have very large errors of around 60 percent. Finally, the veto efficiencies were found to be very high at both veto values, both for charged particles and for the lower energy backsplash spectrum. The Anti Coincidence Detector (ACD) on the Fermi Gamma Ray Space Telescope is a detector system built around the silicon strip tracker on the Large Area Telescope (LAT). The purpose of the ACD is to provide charged particle rejection for the LAT. To do this, the ACD must be calibrated correctly in flight, and must be able to efficiently veto charged particle events while minimizing false vetoes due to 'backsplash' from photons in the calorimeter. There are eleven calibrations used by the ACD. In this paper, we discuss the use of two of these calibrations to preform three studies on the performance of the ACD. The first study examines trending of the calibrations to check for possible hardware degradation. The second study uses the calibrations to explore the efficiency of an on-board hardware veto. The third study uses the calibrations to calculate the number of photoelectrons seen by each PMT when a minimum ionizing particle is detected, which is a useful value for performing simulations.
We present Monte Carlo computational methods for estimating the coincidence resolving time (CRT) of scintillator detector pairs in positron emission tomography (PET) and present results for Lu 2 SiO 5 : Ce (LSO), LaBr 3 : Ce, and a hypothetical ultra-fast scintillator with a 1 ns decay time. The calculations were applied to both single-ended and double-ended photodetector readout with constant-fraction triggering. They explicitly include (1) the intrinsic scintillator properties (luminosity, rise time, decay time, and index of refraction), (2) the exponentially distributed depths of interaction, (3) the optical photon transport efficiency, delay, and time dispersion, (4) the photodetector properties (fill factor, quantum efficiency, transit time jitter, and single electron response), and (5) the determination of the constant fraction trigger level that minimizes the CRT. The calculations for single-ended readout include the delayed photons from the opposite reflective surface. The calculations for double-ended readout include (1) the simple average of the two photodetector trigger times, (2) more accurate estimators of the annihilation photon entrance time using the pulse height ratio to estimate the depth of interaction and correct for annihilation photon, optical photon, and trigger delays, and (3) the statistical lower bound for interactions at the center of the crystal. For time-of-flight (TOF) PET we combine stopping power and TOF information in a figure of merit equal to the sensitivity gain relative to whole-body non-TOF PET using LSO. For LSO crystals 3 mm × 3 mm × 30 mm, a decay time of 37 ns, a total photoelectron count of 4000, and a photodetector with 0.2 ns full-width at half-maximum (fwhm) timing jitter, single-ended readout has a CRT of 0.16 ns fwhm and double-ended readout has a CRT of 0.111 ns fwhm. For LaBr 3 : Ce crystals 3 mm × 3 mm × 30 mm, a rise time of 0.2 ns, a decay time of 18 ns, and a total of 7600 photoelectrons the CRT numbers are 0.14 ns and 0.072 ns fwhm, respectively. For a hypothetical ultra-fast scintillator 3 mm × 3 mm × 30 mm, a decay time of 1 ns, and a total of 4000 photoelectrons, the CRT numbers are 0.070 and 0.020 ns fwhm, respectively. Over a range of examples, values for double-ended readout are about 10% larger than the statistical lower bound.
In this work, we demonstrate theoretically that double angle resolved photoemission spectroscopy (2eARPES) can directly probe the existence of Cooper pairs away from the Fermi surface, and can thus provide insight into the characteristic energy scale around the Fermi surface, the Debye energy, in which electrons are bound into Cooper pairs. To this end, we compute the photoelectron counting rate 𝑃 (2) in two different types of unconventional superconductors, a 𝑑 𝑥 2 −𝑦 2 -wave superconductor, and a topological superconductor with a broken time-reversal symmetry. We show that 𝑃 (2) provides insight into the relative strength of intra- and interband pairing in multiband systems, as well as into the spin polarization of the bands.
Appropriate photodetectors are a major challenge for liquid xenon technology as proposed by the next generation of double beta decay, solar neutrino, and dark matter searches. The primary photon signal is tiny and in the hard ultraviolet, the installation is cryogenic, and the sensors themselves must not introduce background. Hybrid photodiodes (HPDs) provide an easy substitute for a conventional PMT with the added advantages of low radioactivity, better area coverage, and single photoelectron counting. A computer-controlled test setup capable of characterizing optical properties of ultraviolet photodetectors was installed. It was used to compare photomultiplier tubes, silicon photomultipliers, avalanche photodiodes, and a novel-design custom HPD developed by the DEP company under this proposal.
Pixelated High Rate Picosecond Photon Detectors (HRPPDs) by Incom Inc. are promising photosensors for use in Ring Imaging CHerenkov (RICH) detectors, where a high gain, sub-mm position resolution and sub-100ps timing resolution are required in a single photon mode. Quantum Efficiency (QE) has been measured for the first batch of EIC HRPPDs both by Incom and EIC research groups at Jefferson Lab and Brookhaven Lab, with peak values at ∼365 nm typically exceeding 30%. Furthermore, in this study, we present a first direct measurement of Photon Detection Efficiency being equal to (17.1 ± 0.1 [stat] ± 0.3 [sys])% at 398.6 nm, for a pixel near the center of HRPPD, in a photoelectron pulse counting mode using a picosecond diode laser. HRPPD QE at the same spot and at the same wavelength was evaluated to be (24.4 ± 0.1 [stat] ± 0.3 [sys])%, leading to a Collection Efficiency estimate of (70.3 ± 1.6)%, which is consistent with the expectations.
The influence of the imperfection of a polarizer, an analyzer, and a photoelectron multiplier of a spectrophotometric complex on the intensity of light passed through a plane-parallel plate of a uniaxial transparent or absorbing crystal has been theoretically investigated. Expressions for calculating the birefringence and dichroism at different wavelengths are obtained and analyzed. It is established that the influence of the imperfection of optical elements is stronger for calculating the birefringence value, as compared with the calculation of dichroism.
The conditions at which the birth of photoelectrons in a semiconductor or transparent dielectric leads to the appearance of a force causing drift of impurities are found. Drift occurs in the same direction as the displacement of the focal region of the radiation, which excites minority charge carriers. The use of this condition made it possible to show that drift can be more noticeable than diffusion. This process, which can be considered an optical analog of zone melting, is especially important for thin films.
We have used an electron-bombarded CCD for optical photon counting imaging. The photon event pulse height distribution was found to be linearly dependent on the gain voltage. We propose on this basis that a gain voltage sweep during exposure in an electron-bombarded sensor would allow photon arrival time determination with sub-frame exposure time resolution. This effectively uses an electron-bombarded sensor as a parallel-processing photoelectronic time-to-amplitude converter, or a two-dimensional photon counting streak camera. Several applications that require timing of photon arrival, including Fluorescence Lifetime Imaging Microscopy, may benefit from such an approach. A simulation of a voltage sweep performed with experimental data collected with different acceleration voltages validates the principle of this approach. Moreover, photon event centroiding was performed and a hybrid 50% Gaussian/Centre of Gravity + 50% Hyperbolic cosine centroiding algorithm was found to yield the lowest fixed pattern noise. Finally, the camera was mounted on a fluorescence microscope to image F-actin filaments stained with the fluorescent dye Alexa 488 in fixed cells.
The goal of this research is to enable all the energy contained in sunlight to be harvested by making full use of the energy contained in the blue and green wavelengths of light. Current systems are unable to extract all of the energy available from photons in this wavelength range due to rapid relaxation processes that dissipate a fraction of the energy as heat. In this work, inexpensive, earth-abundant components capable of supporting multi-excitonic processes involving more than one tightly bound excited state are investigated as a way to exceed the Shockley-Queisser limit. This research will examine hybrid organic-inorganic nanostructures capable of singlet fission, a process by which one high-energy spin-singlet state is converted into two lower-energy spin-triplet states, and subsequent triplet exciton transfer. Specifically, the organic molecules diphenylhexatriene and tetracene that maximally absorb blue light and are known to exhibit singlet fission will be bound to lead chalcogenide nanocrystals. A variety of steady-state and time-resolved spectroscopic techniques will be used to study the transfer of energy from spin-triplet excitons that are created in the organic molecules to the nanoparticle acceptors. The hybrid nanostructures here will be fully characterized both in solution or thin film via electronic absorption and photoluminescence spectroscopy, nuclear magnetic resonance spectroscopy, high-resolution mass spectrometry, transmission electron microscopy, photoelectron spectroscopy, time correlated single photon counting and transient absorption experiments. The effect of molecular and nanocrystal structure on the electronic coupling between the hybrid components will be examined to establish fundamental relationships between structure and triplet energy transfer efficiency. The findings will be directly applicable to a potential tetracene-silicon platform that may ultimately enhance the power conversion efficiency of silicon solar cells.
By solving the three-dimensional, time-dependent Schroedinger equation, we have demonstrated that the ultrafast charge-transfer process in ion-atom collisions can be mapped out with attosecond extreme uv (xuv) pulses. During the dynamic-charge transfer from the target atom to the projectile ion, the electron coherently populates the two sites of both nuclei, which can be viewed as a 'short-lived' molecular state. A probing attosecond xuv pulse can instantly unleash the delocalized electron from such a ''transient molecule,'' so that the resulting photoelectron may exhibit a ''double-slit'' interference. On the contrary, either reduced or no photoelectron interference will occur if the attosecond xuv pulse strikes well before or after the collision. Therefore, by monitoring the photoelectron interference visibility, one can precisely time the ultrafast charge-transfer process in atomic collisions with time-delayed attosecond xuv pulses.
A simple method has been proposed to suppress artificial noise from the counts with respect to the central line (or point) for the reconstructed 3D images with cylindrical symmetry in the velocity-map imaging spectroscopy. A raw 2D projection around the z-axis (usually referred to as central line) for photodetachment, photoionization, or photodissociation experiments is pre-processed via angular tailored method to avoid the signal counts distributed near the central line (or point). Two types of photoelectron velocity-map imaging (O{sup −} and Au{sup −} ⋅ NH{sub 3}) are demonstrated to give rise to the 3D images with significantly reduced central line noise after pre-processing operation. The major advantages of the pre-operation are the ability of suppression of central-line noise to resolve weak structures or vibrational excitation in atoms or molecules near photon threshold.
Molecular clusters are attractive superatomic building blocks for creating materials with tailored properties due to their unique combination of atomic precision, tunability and functionality. The ligands passivating these superatomic clusters offer an exciting opportunity to control their electronic properties while preserving their closed shells and electron counts, which is not achievable in conventional atoms. Here we demonstrate this concept by measuring the anion photoelectron spectra of a series of hexanuclear cobalt sulfide superatomic clusters with different ratios of electron-donating and electron-withdrawing ligands, Co 6 S 8 (PEt 3 ) 6-x (CO) x (x = 0–3). We find that Co 6 S 8 (PEt 3 ) 6 has a low electron affinity (EA) of 1.1 eV, and that the successive replacement of PEt3 ligands with CO gradually shifts its electronic spectrum to lower energy and increases its EA to 1.8 eV. Density functional theory calculations reveal that the increase of EA results from a monotonic lowering of the cluster highest occupied and lowest unoccupied molecular orbitals (HOMO and LUMO). Our work provides unique insights into the electronic structure and tunability of superatomic building blocks.
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.