Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOGRAPHIC FILMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Economical Laue x-ray diffraction using photographic film and orientation of single crystals

Many Laue x-ray diffraction systems using the Polaroid XR-7 Land Diffraction Cassette camera became inactive after production of the required high sensitivity Polaroid T-57 instant film ceased. This Tutorial reports on a low-cost solution using the readily available replacement film with push processing to increase the effective film speed. The use of this film in the polaroid camera is described along with film development and digitization. The orientation of single crystals with the obtained data and free software is explained. A simple method to prepare single crystals with surfaces perpendicular to a desired crystallographic orientation is described. The content of this Tutorial may prove beneficial for educational and research laboratories.

47 OTHER INSTRUMENTATION↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

An Attempt to Measure the Gamma Radiation Dosage at Hiroshima from Photosensitive Material

After Japan surrendered in August 1945, a team of Los Alamos scientists entered both Hiroshima and Nagasaki to assess the damage of Little Boy and Fat Man. Two of these scientists, Berlyn Brixner and Edwin McMillan, discovered a stock of photographic film in Hiroshima that had been fogged by the gamma radiation from Little Boy. They devised an experiment that they thought might be used to determine the exposure levels in the city. Below is both their description of the film stock and the attempt to determine the exposure levels at Hiroshima.

61 RADIATION PROTECTION AND DOSIMETRY↗

Process model for multilayer slide coating of polymer electrolyte membrane fuel cells

Slide coating is a precision method suitable for depositing multiple liquid-film layers simultaneously. Originally developed in the photographic film industry, it has been deployed for manufacturing of other products that benefit from multilayer coatings. One emerging application is the manufacture of polymer electrolyte membrane fuel cells (PEMFCs), which are used to produce electricity through electrochemical reactions of hydrogen and oxygen gas. The membrane-electrode assembly (MEA), in which key electrochemical reactions occur, consists of three layers that are typically deposited separately in serial fashion and then laminated together to form the three-layer MEA, i.e., three sequential steps of coat and dry. Adapting the process to simultaneous, multilayer slide coating of all three layers will save equipment cost and space while minimizing possible exposure to contaminants during transition between the steps. We are developing a three-layer slide coating model to aid the manufacturing process design of PEMFC. The model accounts for rheology of each layer, which typically exhibit shear thinning behavior. Model predictions are used to investigate simultaneous coatability of catalyst inks and to determine the best layer-by-layer ink selection.

25 ENERGY STORAGE↗

PHASE CORRELATION METHOD FOR THE ALIGNMENT OF TOTAL SOLAR ECLIPSE IMAGES

A modified phase correlation method, based on Fourier transform, which enables the alignment of solar coronal images taken during the total solar eclipses, is presented. The method enables the measurement of translation, rotation, and scaling factor between two images. With the application of this technique, pairs of images with different exposure times, different brightness scale, such as linear for CCD and nonlinear for images taken with photographic film, and even images from different emission lines can be aligned with sub-pixel precision.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental study of neutron induced background noise on gated x-ray framing cameras

A temporally gated x-ray framing camera based on a proximity focus microchannel plate is one of the most important diagnostic tools of inertial confinement fusion experiments. However, fusion neutrons produced in imploded capsules interact with structures surrounding the camera and produce background to x-ray signals. To understand the mechanisms of this neutron induced background, we tested several gated x-ray cameras in the presence of 14 MeV neutrons produced at the Omega laser facility. Differences between background levels observed with photographic film readout and charge-coupled-device readout have been studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A CCD Camera with Electron Decelerator for Intermediate Voltage Electron Microscopy

Electron microscopists are increasingly turning to Intermediate Voltage Electron Microscopes (IVEMs) operating at 300 - 400 kV for a wide range of studies. They are also increasingly taking advantage of slow-scan charge coupled device (CCD) cameras, which have become widely used on electron microscopes. Under some conditions CCDs provide an improvement in data quality over photographic film, as well as the many advantages of direct digital readout. However, CCD performance is seriously degraded on IVEMs compared to the more conventional 100 kV microscopes. In order to increase the efficiency and quality of data recording on IVEMs, we have developed a CCD camera system in which the electrons are decelerated to below 100 kV before impacting the camera, resulting in greatly improved performance in both signal quality and resolution compared to other CCDs used in electron microscopy. These improvements will allow high-quality image and diffraction data to be collected directly with the CCD, enabling improvements in data collection for applications including high-resolution electron crystallography, single-particle reconstruction of protein structures, tomographic studies of cell ultrastructure and remote microscope operation. This approach will enable us to use even larger format CCD chips that are being developed with smaller pixels.

47 OTHER INSTRUMENTATION↗

Determination of Scale Bar for AGHCF Metallography Data

The DOE Nuclear Energy Advanced Reactor Technologies (ART) Fast Reactor Program (FRP) has supported the development of several databases containing information on the safety performance of fast reactors, components, and fuels. This growing collection of legacy experimental data, operating data, and analysis is available online to registered users. Metallography data represents one of the most critical types of post-irradiation examination (PIE) data being collected, organized, and archived in several ART Fast Reactor Databases (https://frdb.ne.anl.gov), including the Metallic Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT (the Transient Reactor Test Facility) Experimental Relational Database (TREXR). These databases contain three principal sets of metallography data. The first set comprises metallography data from Experimental Breeder Reactor-II (EBR-II) and Fast Flux Test Facility (FFTF) irradiated fuel pins examined in the Hot Fuel Examination Facility (HFEF). The second set consists of metallography data from EBR-II irradiated fuel pins examined in the Alpha-Gamma Hot Cell Facility (AGHCF). The third set includes metallography data from transient-tested fuel pins (including both out-of-pile furnace tests and TREAT tests) examined in AGHCF. Since both the second and third sets were generated in AGHCF, they are governed by identical specifications. The metallography data in the databases consist of digital images scanned from either positive or negative photographic films. To analyze the microstructure of a fuel pin, a series of preparatory steps are required, including sectioning, epoxy mounting, mechanical grinding and polishing, and etching. Following sample preparation, specimens are transferred for metallographic examination. The AGHCF and HFEF metallography data were generated using optical microscopes manufactured by Leitz and Bausch and Lomb (B&L). Images were recorded on Polaroid film at preset magnifications. Magnification verification for the Leitz and B&L metallographs was conducted every two months prior to 1989 and at least every six months from 1989 through the conclusion of the IFR program. Magnifications determined from imaging of microslide standards were compared to the instrument settings for magnifications ranging from 50× to 500×. If the magnifications determined from standards deviated from the instrument settings, adjustments were made to the bellows extension until agreement was achieved. The specifications for AGHCF and HFEF legacy metallography data have been established based on available hard-copy and digital records, most of which have been incorporated into the data repositories associated with FIPD, OPTD, and TREXR. Detailed specifications including hard-copy records, digitized records, cutting diagrams and sectioning schemes, high-magnification photographs, photomosaics (composites), information tags, scale bars, and magnification verification procedures can be found in a separate report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Case studies of robots and automation as health/safety interventions in small manufacturing enterprises

This article reviews the experiences of 63 case studies of small businesses (<250 employees) with manufacturing automation equipment acquired through a health/safety intervention grant program. The review scope included equipment technologies classified as industrial robots (n = 17), computer numerical control (CNC) machining (n = 29), or other programmable automation systems (n = 17). Descriptions of workers' compensation (WC) claim injuries and identified risk factors that motivated the acquisition of the equipment were extracted from grant applications. Other aspects of the employer experiences, including qualitative and quantitative assessment of effects on risk factors for musculoskeletal disorders (MSD), effects on productivity, and employee acceptance of the intervention were summarized from the case study reports. Case studies associated with a combination of large reduction in risk factors, lower cost per affected employee, and reported increases in productivity were CNC stone cutting system, CNC/vertical machining system, automated system for bottling, CNC/routing system for plastics products manufacturing, and a CNC/Cutting system for vinyl/carpet. Six case studies of industrial robots reported quantitative reductions in MSD risk factors in these diverse manufacturing industries: snack foods; photographic film, paper, plate, and chemical; machine shops; leather goods and allied products; plastic products; and iron and steel forging. Furthermore, this review of health/safety intervention case studies indicates that advanced (programmable) manufacturing automation, including industrial robots, reduced workplace musculoskeletal risk factors, and improved process productivity in most cases.

42 ENGINEERING↗

Witness the Trinity test through Lab artifacts

July 16 marks the 77th anniversary of the Trinity test, conducted in a desert in New Mexico. The test subject, an atomic bomb called The Gadget, was successfully detonated from a 100-foot steel tower. This event marks the commencement of the Atomic Age, a new era where fission capabilities could be employed for national security purposes. Shortly after the Trinity test, two Los Alamos-created atomic weapons were released above Japan, helping to end the world’s bloodiest conflict just weeks later. “Trinity was one of the greatest scientific experiments ever,” said NSRC Senior Historian Alan Carr said. “Los Alamos scientists changed the world forever on that day. Not only was it the dawn of the Atomic Age, but also the beginning of the Lab’s eight decades of cutting-edge science and its national security charge.” To preserve this event, and to continue to learn more about this critical moment in history, the National Security Research Center (NSRC) curates a collection of photographs, films, notes, unclassified artifacts and numerous other materials related to the science of the test. Notably, the collection includes a novel material that formed at the site, trinitite, and artifacts from one of the intriguing scientists present at the test, Enrico Fermi.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Complete time-resolved X-ray shape capability for a 10 MJ implosion: Milestone Report for MRT 8818

This report documents completion of MRT 8818, which established an upgraded equatorial time-resolved X-ray imaging capability for high-yield inertial confinement fusion experiments at the National Ignition Facility (NIF) using the equatorial Dilation X-ray Imager (DIXI). The need for this work arose from the sustained increase in fusion yield at NIF, which progressively intensified the neutron and gamma-ray environment experienced by target diagnostics. Although the existing polar imaging capability, particularly the Polar Dilation X-ray Imager (PDIXI), remained viable at high yields, the equatorial capability became inadequate because of radiation-induced failure of electronic readout hardware and increasing background levels that degraded image quality and ultimately caused saturation. The work performed under MRT 8818 addressed this limitation through a combination of hardware replacement, background characterization, and targeted mitigation. The DIXI backend was converted from CCD-based electronic readout to photographic film, and the principal sources of internally generated background were investigated using prior analyses, dedicated tests, and comparison with PDIXI performance on high-yield shots. This effort led to implementation of two principal improvements: a multilayer optical coating to suppress broadband radiation-induced background generated in the fiber-optic extension cylinder, and replacement of Kodak TMAX 400 film with Agfa Copex Rapid to reduce background generated directly in the film. These upgrades were completed in 2025 and performance assessment based on DT shot data since then, comparing with Polar DIXI and scaling of these experiments to 10 MJ indicates an expected signal-to-background ratio of approximately 34 for a single pinhole image, substantially exceeding the MRT 8818 completion criterion of SNR > 5.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the fine structure splitting of the 3p{sup 4}3d {sup 4}D{sub 5/2} and 3p{sup 4}3d {sup 4}D{sub 7/2} levels of Fe x

We study UV spectra obtained with the SO82-B slit spectrograph on board SKYLAB to estimate the fine structure (FS) splitting of the Cl-like 3p{sup 4}3d{sup 4}D{sub 5/2} and 3p{sup 4}3d{sup 4}D{sub 7/2} levels of Fe x. The splitting is of interest because the Zeeman effect mixes these levels, producing a “magnetically induced transition” (MIT) from 3p{sup 4}3d{sup 4}D{sub 7/2} to 3p{sup 52}P{sub 3/2}{sup o} for modest magnetic field strengths characteristic of the active solar corona. We estimate the splitting using the Ritz combination formula applied to two lines in the UV region of the spectrum close to 1603.2 Å, which decay from the level 3p{sup 4}({sup 1}D)3d{sup 2}G{sub 7/2} to these two lower levels. The MIT and accompanying spin-forbidden transition lie near 257 Å. By careful inspection of a deep exposure obtained with the S082B instrument, we derive a splitting of ≲7±3 cm{sup −1}. The upper limit arises because of a degeneracy between the effects of non-thermal line broadening and FS splitting for small values of the latter parameter. Although the data were recorded on photographic film, we solved for optimal values of line width and splitting of 8.3 ± 0.9 and 3.6 ± 2.7 cm{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-498: Initial Characterization of the New EBT XD Gafchromic Film

Purpose To assess the dosimetric accuracy of the new EBT XD (eXtended Dose) Gafchromic film and to compare the lateral scan effect between EBT XD and EBT3 film. Methods: All films were exposed in solid water using a 6 MV beam and were analyzed with FilmQA Pro software and an Epson 10000 XL scanner. Calibration was performed using films exposed to 8 known doses from 0–3000 cGy. To assess dosimetric accuracy, a 15×18 cm{sup 2} 60° EDW delivered a dose range of 200–2900 cGy to 4 separate EBT XD films. Comparison to treatment planning system (TPS) predictions was made using a gamma analysis with 2%/2mm passing criteria. To assess the lateral scan effect, 21 × 21 cm{sup 2} open fields delivered doses of 1000, 2000, and 3000 cGy isocentrically to both EBT3 and EBT XD films at 10 cm depth. Films were centered and scanned such that the widest parts of the exposed film extended lateral to the center of the scanner bed in order to maximize the lateral scan effect. Ratios of measured to TPS predicted doses for EBT3 and EBT XD film were calculated at 5 cm and 8 cm lateral from the center of the scanner bed to quantitatively assess the lateral scan effect. Results The average gamma passing rate for the EDW was 98.9% (range 98.7 – 99.1%). EBT XD film exhibited minimal lateral scan effect (<1%) up to 30 Gy. In contrast, EBT3 showed an under-response of 13% and 25% at lateral positions of 5 cm and 8 cm respectively for the 30 Gy exposure. Conclusion EBT XD can accurately measure dose over a wide dynamic range. The non-polarizing structure of its active ingredient essentially eliminates the lateral scan effect up to at least 30 Gy. EBT XD film is therefore well suited for SRS/SBRT verification measurements.

60 APPLIED LIFE SCIENCES↗

A spectroscopic study of the chromatic properties of GafChromic™EBT3 films

Purpose: This work provides an interpretation of the chromatic properties of GafChromic™EBT3 films based on the chemical nature of the polydiacetylene (PDA) molecules formed upon interaction with ionizing radiation. The EBT3 films become optically less transparent with increasing radiation dose as a result of the radiation-induced polymerization of diacetylene monomers. In contrast to empirical quantification of the chromatic properties, less attention has been given to the underlying molecular mechanism that induces the strong decrease in transparency. Methods: Unlaminated GafChromic™EBT3 films were irradiated with a 6 MV photon beam to dose levels up to 20 Gy. The optical absorption properties of the films were investigated using visible (vis) spectroscopy. The presence of PDA molecules in the active layer of the EBT3 films was investigated using Raman spectroscopy, which probes the vibrational modes of the molecules in the layer. The vibrational modes assigned to PDA’s were used in a theoretical vis-absorption model to fit our experimental vis-absorption spectra. From the fit parameters, one can assess the relative contribution of different PDA conformations and the length distribution of PDA’s in the film. Results: Vis-spectroscopy shows that the optical density increases with dose in the full region of the visible spectrum. The Raman spectrum is dominated by two vibrational modes, most notably by the ν(C≡C) and the ν(C=C) stretching modes of the PDA backbone. By fitting the vis-absorption model to experimental spectra, it is found that the active layer contains two distinct PDA conformations with different absorption properties and reaction kinetics. Furthermore, the mean PDA conjugation length is found to be 2–3 orders of magnitude smaller than the crystals PDA’s are embedded in. Conclusions: Vis- and Raman spectroscopy provided more insight into the molecular nature of the radiochromic properties of EBT3 films through the identification of the excited states of PDA and the presence of two PDA conformations. The improved knowledge on the molecular composition of EBT3’s active layer provides a framework for future fundamental modeling of the dose–response.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

SU-E-T-497: Initial Characterization of a Novel 2D Computed Radiography (CR) Dosimeter for SBRT

Purpose For 2D, sub-mm resolution dose measurements Gafchromic™ film is currently a standard in radiotherapy; mainly because of its energy independence and water equivalence. However, EBT film is disposable. Therefore, the dosimetric and uniformity characteristics needs to be estimated from a second, possibly different, (calibration) film. Moreover, EBT has a post-irradiation coloration and a non-linear dose dependence with saturation, which limits the applicable time interval and dose range. CR technology forms an interesting alternative for EBT. Dose dependent CRplates have a sub-mm resolution, and additionally a linear dose dependence over decades of dose. But, CR has an inherent signal fading and energy dependence. Here, for the first time, a radiotherapy 2D CR prototype was characterized for an extended dose range (up to 35Gy), signal fading, and basic energy dependence. Methods The prototype was irradiated with a standard 10×10cm 6MV photon beam, and scanned with a commercial CR 15-X(R) scanner. The time between the start of irradiation and scanning (T-Scan) was monitored. The linearity of the dose response was evaluated between 0 and 35Gy using a fixed T-Scan of 4min, if possible (i.e. ≤10Gy). Next, the signal fading was characterized for a T-Scan-range of 4 to 20min. The energy dependence was assessed by a comparison of out-of-field measurements of CR, EBT, and TLD. Results The radiotherapy CR prototype has a linear response over the complete SBRT dose range (0– 35Gy). The prototype had a small (5%), but linear signal fading over the time interval of interest (4–20min). Out-of-field, the prototype has a 8% over response due to an increased amount of low energy photons. The impact of the over response on intensity modulated radiotherapy remains to be evaluated. Conclusion CR technology is promising for SBRT dose measurements up to 35Gy. It is a reusable linear alternative for film dosimetry.

60 APPLIED LIFE SCIENCES↗

Light Output and Thermal Blast Analysis of Nuclear Fireballs

During the 1940s, 50s, and 60s, there were 210 atmospheric nuclear tests. Every test was extensively recorded with high quality motion picture films and photographs, providing a unique historic record, containing ~10,000 films, with a total of ~22 million frames of information. Much of what is known about the effects of nuclear weapons has been obtained from these tests. There are approximately 6500 scientific films that are in the process of being scanned by Lawrence Livermore National Laboratory and re-analyzed using modern computer techniques. The four major effects of a nuclear detonation are prompt radiation, shockwave, thermal blast, and fallout. The objective of this interim report is to describe recent efforts to extract benchmark data from the existing streak films using modern Figure-processing techniques. These new and, hopefully, greatly-improved data will provide our code developers with the benchmark data necessary to validate our modern computer codes that simulate nuclear weapon effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Yield Analysis of Nuclear Fireballs

During the1940s, 50s, and 60s, there were 210 atmospheric nuclear tests. Every test was extensively recorded with high quality motion picture films and photographs, providing a unique historic record, containing ~10,000 films, with a total of ~22 million frames of information. Much of what is known about the effects of nuclear weapons has been obtained from these tests.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗