Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOGRAPHIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Canopy reflectance spectra and photographs (raw data), Seward Peninsula, Alaska, 2022

Measurements of full-range (350–2500 nm) canopy spectral reflectance of Arctic plant species, plots, and transects at the Next Generation Ecosystem Experiment Arctic (NGEE Arctic) Teller Mile Marker (MM27) and Kougarok Fire Complex (KFC) sites, Seward Peninsula, Alaska. Spectra were collected in July 2022 using a handheld SVC HR-2014i spectroradiometer. All spectra were collected as calibrated surface radiance and converted to surface reflectance using 99.99% reflective Spectralon white reference standard. This data package includes unprocessed instrument output of the spectra signals (.sig) and, for some canopy measurements, photographs of the target taken by the SVC instrument camera or handheld digital camera (.jpg), GPS locations and file metadata (.csv).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Graupel Precipitating From Thin Arctic Clouds With Liquid Water Paths Less Than 50 g m -2

Rimed precipitation growth can efficiently remove moisture and aerosols from the boundary layer, yet thin low-level Arctic mixed-phase clouds are generally thought to precipitate pristine and aggregated ice crystals. Here we present automated surface photographic measurements showing that only 34% of precipitation particles exhibit negligible riming and that graupel particles ≥ in diameter commonly fall from clouds with liquid water paths less than 50 g m -2 . Analyses indicate that significant riming enhancement can occur provided sustained updrafts of 0.4 m s -1 , consistent with those measured in Arctic clouds. A Lagrangian numerical simulation that tracks falling particles suggests that similar updraft speeds can account for about one half of the observed riming enhancement. Riming enhancement appears particularly likely when weak temperature inversions are observed at cloud top, but a full explanation remains to be determined.

54 ENVIRONMENTAL SCIENCES↗

Particle Physics Division Lifting Fixtures Database Restructure

In this project, a thorough investigation is conducted to determine the current placements of all lifting fixtures within the Particle Physics Division (PPD) buildings - as well as whether which ones are still operable. Briefly, the reasoning as to why these lifting fixtures must be found and the database must be updated is covered in the beginning sections of the report. Many tools and fixtures get moved around and forgotten about, and Fermilab’s systems have been updated more than a few times throughout the years, so data can get lost and forgotten about. Considering that many of these lifting fixtures have not been used in years or there is missing, impertinent information that is required by Fermilab’s modern standards and safety regulations. Lifting fixtures found at each site are measured, photographed, and logged; later analyzed to determine if they are under PPD’s purview or another department so that the respective authorities can be notified. Once maximum information is found for all the fixtures they are formatted to 2025 Fermilab standards in an easily accessible digital list for PPD employees.

Creedon, Carroll [Unlisted, US, IL]↗

Narrow-band radiation wavelength measurement by processing digital photographs in RAW format

The technique of measuring the mean wavelength of narrow-band radiation in the 455 - 625-nm range using the image of the emitting surface is presented. The data from the camera array unprocessed by the built-in processor (RAW format) are used. The method is applied for determining the parameters of response of holographic sensors. Depending on the wavelength and brightness of the image fragment, the mean square deviation of the wavelength amounts to 0.3 - 3 nm. (experimental techniques)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Association between radiation, glaucoma subtype, and retinal vessel diameter in atomic bomb survivors

We examined the relationship between glaucoma subtype and retinal vascular caliber as markers of ocular circulation. Subjects were Japanese atomic bomb survivors in Hiroshima and Nagasaki. After a screening examination, potential cases were subjected to further defnitive examination. The diameters of central retinal artery and vein equivalents (CRAE and CRVE) on digitized retinal photographs were measured using an established method. Generalized linear regression analyses were used to examine the associations among vessel diameters, radiation exposure, and prevalence of glaucoma subtypes among the study subjects. We identifed 196 cases of glaucoma (12%) based on optic disc appearance, perimetry results, and other ocular fndings. The main subtypes were primary angle-closure glaucoma, primary open-angle glaucoma and normal-tension glaucoma (NTG). NTG was the dominant subtype (78%). NTG was negatively associated with CRAE and CRVE, and positively associated with radiation dose. CRVE was negatively associated with radiation dose and the association was unclear for CRAE. The smaller retinal vessel caliber in NTG patients than in subjects without glaucoma may indicate an association between ocular blood fow and the pathogenesis of NTG. However, signifcant relationships among vessel calibers, NTG and radiation exposure were not clear.

60 APPLIED LIFE SCIENCES↗

Temporal behavior of cold atmospheric plasma jet

Temporally resolved evolution of parameters in atmospheric plasma jet is studied by means of microwave scattering, fast photographing, and measuring of jet currents. It is observed that streamer ('plasma bullet') propagating along with gas flow is generated immediately after the breakdown. It is demonstrated that an afterglow plasma column remains on the way of streamer passing. Lifetime of the afterglow plasma column is 3-5 {mu}s, which is longer than that of the streamer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study on electrical characteristics of barrier-free atmospheric air diffuse discharge generated by nanosecond pulses and long wire electrodes

In room-temperature atmospheric air, the large-scale diffuse plasmas can be generated via high-voltage nanosecond pulses with short rise-time and wire electrodes. Diffuse discharge with the wire electrode length up to 110.0 cm and the discharge spacing of several centimeters has been investigated in this paper. Electrical characteristics of diffuse discharge have been analyzed by their optical photographs and measuring of the voltage and current waveforms. Experimental results show the electrode spacing, and the length of wire electrodes can influence the intensity and mode transition of diffuse discharge. The characteristic of current waveforms is that there are several current oscillation peaks at the time of applied pulsed voltage peak, and at the tail of applied pulse, the conduction current component will compensate the displacement one so that the measured current is unidirectional in diffuse discharge mode. The transition from diffuse discharge to arc discharge is always with the increasing of conduction current density. As for nanosecond pulses with long tail, the long wire electrodes are help for generating non-equilibrium diffuse plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE PHOTOMETRIC STUDY OF A NEGLECTED NEAR CONTACT BINARY: BS VULPECULAE

We present a detailed study of the close eclipsing binary BS Vulpeculae. Although it is relatively bright (V: 10.9-11.6 mag) and belongs to short-periodic variable stars (P = 0.48 days), it is rather neglected. To perform a thorough period analysis, we collected all available photometric observations that span the time interval of 1898-2010. Observations include archive photographic plate measurements and visually determined eclipse minima timings done in 1979-2003, which were later shown to be biased to accommodate the existing linear ephemeris. Applying our own direct period analysis we found a well-defined shortening of the orbital period of dP/dt = -6.70(17) Multiplication-Sign 10{sup -11} = -2.11(6) ms yr{sup -1}, which implies a continual mass flow from the primary to the secondary component. Using the 2003 version of the Wilson-Van Hamme code, our new complete BV(IR){sub C} light curves were analyzed and the physical parameters of the system were derived. We found that BS Vul is a near contact binary system with the primary component filling its critical Roche lobe. The luminosity enhancement on the left shoulder of the secondary minimum shown in the light curves can be explained as a result of a persistent hot spot on the secondary due to the mass transfer from the primary component to the secondary one and heating the facing hemisphere of the secondary component, which is consistent with our result of period analysis. With the period decrease, BS Vul will evolve toward the contact phase. It is another good observational example as predicted by the theory of thermal relaxation oscillations.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-13: A Feasibility Study of the Use of Hybrid Computational Phantoms for Improved Historical Dose Reconstruction in the Study of Late Radiation Effects for Hodgkin's Lymphoma

Purpose: Radiation-induced cancer effects are well-documented following radiotherapy. Further investigation is needed to more accurately determine a dose-response relationship for late radiation effects. Recent dosimetry studies tend to use representative patients (Taylor 2009) or anthropomorphic phantoms (Wirth 2008) for estimating organ mean doses. In this study, we compare hybrid computational phantoms to patient-specific voxel phantoms to test the accuracy of University of Florida Hybrid Phantom Library (UFHP Library) for historical dose reconstructions. Methods: A cohort of 10 patients with CT images was used to reproduce the data that was collected historically for Hodgkin's lymphoma patients (i.e. caliper measurements and photographs). Four types of phantoms were generated to show a range of refinement from reference hybrid-computational phantom to patient-specific phantoms. Each patient is matched to a reference phantom from the UFHP Library based on height and weight. The reference phantom is refined in the anterior/posterior direction to create a ‘caliper-scaled phantom’. A photograph is simulated using a surface rendering from segmented CT images. Further refinement in the lateral direction is performed using ratios from a simulated-photograph to create a ‘photograph and caliper-scaled phantom’; breast size and position is visually adjusted. Patient-specific hybrid phantoms, with matched organ volumes, are generated and show the capabilities of the UF Hybrid Phantom Library. Reference, caliper-scaled, photograph and caliper-scaled, and patient-specific hybrid phantoms are compared with patient-specific voxel phantoms to determine the accuracy of the study. Results: Progression from reference phantom to patient specific hybrid shows good agreement with the patient specific voxel phantoms. Each stage of refinement shows an overall trend of improvement in dose accuracy within the study, which suggests that computational phantoms can show improved accuracy in historical dose estimates. Conclusion: Computational hybrid phantoms show promise for improved accuracy within retrospective studies when CTs and other x-ray images are not available.

60 APPLIED LIFE SCIENCES↗

Surveillance Report on SAVY 4000 and Hagan Nuclear Material Storage Containers ( FY2019 Update)

A Surveillance Program is in place to assess how nuclear material storage containers at LANL are aging in-service. This program is guided by the LANL Surveillance Plan which is required by DOE M441.1-1. The plan is modified as necessary to ensure that any issues identified during surveillance or laboratory studies are examined in future surveillances, and that any lifetime implications are taken into account. Under the plan, overall container integrity is evaluated by a combination of visual inspections and photographs. Multiple measurements are made to assess the SAVY 4000 performance, including, helium leakage rate, O-ring hardness (durometer), O-ring compression set, filter performance and filter water resistance. The containers for surveillance are chosen annually based on the previous surveillance program results and observations. The surveillance plan targets items believed to provide the greatest challenge to the SAVY 4000 container integrity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surveillance Report on SAVY 4000 and Hagan Nuclear Material Storage Containers Update for FY2020

A Surveillance Program is in place to assess how nuclear material storage containers at LANL are aging in-service. This program is guided by the LANL Surveillance Plan which is required by DOE M441.1-1. The plan is modified as necessary to ensure that any issues identified during surveillance or laboratory studies are examined in future surveillances, and that any lifetime implications are taken into account. Under the plan, overall container integrity is evaluated by a combination of visual inspections and photographs. Multiple measurements are made to assess the SAVY 4000 performance, including, helium leakage rate, O-ring hardness (durometer), O-ring compression set, filter performance and filter water resistance. The containers for surveillance are chosen annually based on the previous surveillance program results and observations. The surveillance plan targets items believed to provide the greatest challenge to the SAVY 4000 container integrity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Particle Physics Division Lifting Fixture Database Restructure

The Particle Physics Division (PPD) at Fermilab needed to modernize its outdated lifting fixture database. Many fixtures lacked identification or had incomplete information. During a summer internship, I cross-referenced existing data, photographed and measured fixtures using standardized tools, and updated their locations and details in a modern Excel format. Some fixtures were identified as belonging to other departments, like the Applied Physics and Superconducting Technology Directorate (APS-TD). This effort significantly improved the accuracy and utility of the PPD database, streamlined other departmental inventories, and potentially saved hundreds of thousands of dollars. The work concluded with a clear, organized record of all verified lifting fixtures.

Creedon, Carroll [Unlisted, US, IL; Fermilab]↗

Automated commissioning and inspection for PV systems

An electric system includes a local power controller and solar panel system that includes a plurality of solar modules on one or more branch circuits. A method for commissioning the electric system includes an installer using a commissioning device to send and receive information from a remote system and the local power controller performing an automatic self-test of the electric system. The results of the self-test may be packaged with photographs and measurements of the electric system and sent to a remote system where an inspector can inspect the electric system remotely. After receiving approval by the inspector, the local power controller may automatically activate each branch circuit of the electric system and thus enabling the electric system to generate electricity.

14 SOLAR ENERGY↗

Leaf-to-canopy spectral reflectance, February 2018, PA-SLZ: Panama

Canopy reflectance spectra of 37 trees were measured at the Smithsonian Tropical Research Institute (STRI) San Lorenzo Protected Area site (PA-SLZ), utilising the canopy access crane to access fully sunlit leaves. Data were recorded in the middle of the day, with 20–50 measurements for each tree. The canopy structure for each crown was captured using a digital camera. Leaf-level reflectance and leaf demographic composition (age class) was recorded in detail for a > 0.5 meter branch sampled from each canopy tree (corresponding to the position where canopy spectra were measured). This dataset includes processed canopy and leaf-level spectral measurements (*.xlsx), raw spectral data (Spectral Evolution PSR+, *.raw, *.sed), sample details (*.xlsx) and *.pdf summaries containing low resolution photographs of the measured canopies. Full resolution images are available in the related dataset, "Leaf-to-canopy spectral reflectance photographs, February 2018, PA-SLZ: Panama".

54 ENVIRONMENTAL SCIENCES↗

Effects of CO addition on the characteristics of laminar premixed CH{sub 4}/air opposed-jet flames

The effects of CO addition on the characteristics of premixed CH{sub 4}/air opposed-jet flames are investigated experimentally and numerically. Experimental measurements and numerical simulations of the flame front position, temperature, and velocity are performed in stoichiometric CH{sub 4}/CO/air opposed-jet flames with various CO contents in the fuel. Thermocouple is used for the determination of flame temperature, velocity measurement is made using particle image velocimetry (PIV), and the flame front position is measured by direct photograph as well as with laser-induced predissociative fluorescence (LIPF) of OH imaging techniques. The laminar burning velocity is calculated using the PREMIX code of Chemkin collection 3.5. The flame structures of the premixed stoichiometric CH{sub 4}/CO/air opposed-jet flames are simulated using the OPPDIF package with GRI-Mech 3.0 chemical kinetic mechanisms and detailed transport properties. The measured flame front position, temperature, and velocity of the stoichiometric CH{sub 4}/CO/air flames are closely predicted by the numerical calculations. Detailed analysis of the calculated chemical kinetic structures reveals that as the CO content in the fuel is increased from 0% to 80%, CO oxidation (R99) increases significantly and contributes to a significant level of heat-release rate. It is also shown that the laminar burning velocity reaches a maximum value (57.5 cm/s) at the condition of 80% of CO in the fuel. Based on the results of sensitivity analysis, the chemistry of CO consumption shifts to the dry oxidation kinetics when CO content is further increased over 80%. Comparison between the results of computed laminar burning velocity, flame temperature, CO consumption rate, and sensitivity analysis reveals that the effect of CO addition on the laminar burning velocity of the stoichiometric CH{sub 4}/CO/air flames is due mostly to the transition of the dominant chemical kinetic steps. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using morphometrics, in situ observations and genetic characters to distinguish among commercially valuable Hawaiian black coral species; a redescription of Antipathes grandis Verrill, 1928 (Antipatharia : Antipathidae)

The commercially valuable Hawaiian black coral Antipathes grandis Verrill, 1928 is redescribed based on reexamination of the holotype from the Bernice P. Bishop Museum and field collections of 34 specimens from depths of 27-127 m. The first scanning electron micrographs of A. grandis skeletal spines are provided, along with a series of in situ color photographs and morphometric measurements of spines and polyps. Three color morphotypes were collected in the field (red, pale red, and white), none of which could be differentiated based on morphological or genetic characters (two mitochondrial and two nuclear markers). In situ observations are used in conjunction with morphological and genetic characters to distinguish among the commercially valuable Hawaiian black coral species A. grandis and A. griggi Opresko, 2009. A. grandis is differentiated from A. griggi by its finer and more irregular branching, smaller and more closely-spaced polyps, and conical spines that are smaller and not characterized by bifurcations towards their apex. Morphologically, the species most closely resembling A. grandis is A. caribbeana Opresko, 1996 from the Caribbean. Among analyzed congenerics, DNA sequences of A. grandis were likewise most similar to those of A. caribbeana for three of the four molecular markers used in this study. A combination of low genetic variability, incomplete taxonomic sampling, and unexpected similarity between A. caribbeana and the unbranched whip coral Stichopathes cf. occidentalis (Gray, 1860), hindered our ability to determine the sister relationship of A. grandis. However, in no phylogenetic reconstruction did A. grandis group sister to its sympatric congener A. griggi.

59 BASIC BIOLOGICAL SCIENCES↗

THE BEHAVIOR OF NOVAE LIGHT CURVES BEFORE ERUPTION

In 1975, E. R. Robinson conducted the hallmark study of the behavior of classical nova light curves before eruption, and this work has now become part of the standard knowledge of novae. He made three points: 5 out of 11 novae showed pre-eruption rises in the years before eruption, one nova (V446 Her) showed drastic changes in the variability across eruptions, and all but one of the novae (excepting BT Mon) have the same quiescent magnitudes before and after the outburst. This work has not been tested since it came out. We have now tested these results by going back to the original archival photographic plates and measuring large numbers of pre-eruption magnitudes for many novae using comparison stars on a modern magnitude scale. We find in particular that four out of five claimed pre-eruption rises are due to simple mistakes in the old literature, that V446 Her has the same amplitude of variations across its 1960 eruption, and that BT Mon has essentially unchanged brightness across its 1939 eruption. Out of 22 nova eruptions, we find two confirmed cases of significant pre-eruption rises (for V533 Her and V1500 Cyg), while T CrB has a deep pre-eruption dip. These events are a challenge to theorists. We find no significant cases of changes in variability across 27 nova eruptions beyond what is expected due to the usual fluctuations seen in novae away from eruptions. For 30 classical novae plus 19 eruptions from 6 recurrent novae, we find that the average change in magnitude from before the eruption to long after the eruption is 0.0 mag. However, we do find five novae (V723 Cas, V1500 Cyg, V1974 Cyg, V4633 Sgr, and RW UMi) that have significantly large changes, in that the post-eruption quiescent brightness level is over ten times brighter than the pre-eruption level. These large post-eruption brightenings are another challenge to theorists.

79 ASTRONOMY AND ASTROPHYSICS↗