Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTON EMISSION SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

New Possibilities of Positron-Emission Tomography

The reasons for the emergence of the angular distribution of photons generated as a result of annihilation of an electron and a positron in a positron-emission tomograph are investigated. It is shown that the angular distribution of the radiation intensity (i.e., the probability of photon emission at different angles) is a consequence of the Doppler effect in the center-of-mass reference system of the electron and the positron. In the reference frame attached to the electron, the angular distribution of the number of emitted photons does not exists but is replaced by the Doppler shift of the frequency of photons. The results obtained in this study make it possible to extend the potentialities of the positron-emission tomograph in the diagnostics of diseases and to obtain additional mechanical characteristics of human tissues, such as density and viscosity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of cardiac single-photon emission computed tomography performance using a scanning linear observer

Purpose: Single-photon emission computed tomography (SPECT) is widely used to detect myocardial ischemia and myocardial infarction. It is important to assess and compare different SPECT system designs in order to achieve the highest detectability of cardiac defects. Methods: Whitaker et al.'s study ['Estimating random signal parameters from noisy images with nuisance parameters: linear and scanning-linear methods,' Opt. Express 16(11), 8150-8173 (2008)] on the scanning linear observer (SLO) shows that the SLO can be used to estimate the location and size of signals. One major advantage of the SLO is that it can be used with projection data rather than with reconstruction data. Thus, this observer model assesses the overall hardware performance independent of any reconstruction algorithm. In addition, the computation time of image quality studies is significantly reduced. In this study, three systems based on the design of the GE cadmium zinc telluride-based dedicated cardiac SPECT camera Discovery 530c were assessed. This design, which is officially named the Alcyone Technology: Discovery NM 530c, was commercialized in August, 2009. The three systems, GE27, GE19, and GE13, contain 27, 19, and 13 detectors, respectively. Clinically, a human heart can be virtually segmented into three coronary artery territories: the left-anterior descending artery, left-circumflex artery, and right coronary artery. One of the most important functions of a cardiac SPECT system is to produce images from which a radiologist can accurately predict in which territory the defect exists [http://www.asnc.org/media/PDFs/PPReporting081511.pdf, Guideline from American Society of Nuclear Cardiology]. A good estimation of the extent of the defect from the projection images is also very helpful for determining the seriousness of the myocardial ischemia. In this study, both the location and extent of defects were estimated by the SLO, and the system performance was assessed by localization receiver operating characteristic (LROC) [P. Khurd and G. Gindi, 'Decision strategies maximizing the area under the LROC curve,' Proc. SPIE 5749, 150-161 (2005)] or estimation receiver operating characteristic (EROC) [E. Clarkson, 'Estimation receiver operating characteristic curve and ideal observers for combined detection/estimation tasks,' J. Opt. Soc. Am. A 24, B91-B98 (2007)] curves. Results: The area under the LROC/EROC curve (AULC/AUEC) and the true positive fraction (TPF) at a specific false positive fraction (FPF) can be treated as the figures of merit. For radii estimation with a 1 mm tolerance, the AUEC values of the GE27, GE19, and GE13 systems are 0.8545, 0.8488, and 0.8329, and the TPF at FPF = 5% are 77.1%, 76.46%, and 73.55%, respectively. The assessment of all three systems revealed that the GE19 system yields estimated information and cardiac defect detectability very close to those of the GE27 system while using eight fewer detectors. Thus, 30% of the expensive detector units can be removed with confidence. Conclusions: As the results show, a combination of the SLO and LROC/EROC curves can determine the configuration that yields the most relevant estimation/detection information. Thus, this is a useful method for assessing cardiac SPECT systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical nonlinearities of colloidal InP@ZnS core-shell quantum dots probed by Z-scan and two-photon excited emission

Spectrally resolved nonlinear optical properties of colloidal InP@ZnS core-shell quantum dots of various sizes were investigated with the Z-scan technique and two-photon fluorescence excitation method using a femtosecond laser system tunable in the range from 750 nm to 1600 nm. In principle, both techniques should provide comparable results and can be interchangeably used for determination of the nonlinear optical absorption parameters, finding maximal values of the cross sections and optimizing them. We have observed slight differences between the two-photon absorption cross sections measured by the two techniques and attributed them to the presence of non-radiative paths of absorption or relaxation. The most significant value of two-photon absorption cross section σ{sub 2} for 4.3 nm size InP@ZnS quantum dot was equal to 2200 GM, while the two-photon excitation action cross section σ{sub 2}Φ was found to be 682 GM at 880 nm. The properties of these cadmium-free colloidal quantum dots can be potentially useful for nonlinear bioimaging.

36 MATERIALS SCIENCE↗

A nanoscale gigahertz source realized with Josephson scanning tunneling microscopy

Using the AC Josephson effect in the superconductor-vacuum-superconductor tunnel junction of a scanning tunneling microscope (STM), we demonstrate the generation of GHz radiation. With the macroscopic STM tip acting as a λ/4-monopole antenna, we first show that the atomic scale Josephson junction in the STM is sensitive to its frequency-dependent environmental impedance in the GHz regime. Further, enhancing Cooper pair tunneling via excitations of the tip eigenmodes, we are able to generate high-frequency radiation. We find that for vanadium junctions, the enhanced photon emission can be tuned from about 25 GHz to 200 GHz and that large photon flux in excess of 10{sup 20 }cm{sup −2} s{sup −1} is reached in the tunnel junction. These findings demonstrate that the atomic scale Josephson junction in an STM can be employed as a full spectroscopic tool for GHz frequencies on the atomic scale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermographic system with a laser scanning device

It is shown that laser photothermal radiometry (LPTR) in combination with laser beam scanning within the instantaneous field of view of a single-element photodetector can be used to develop a scanning thermal emission microscope. An expression is derived for estimating its temperature resolution. The results of calculations are presented and the factors influencing the spatial lateral resolution of the technique and the time of image formation with the help of an acousto-optical deflector are analysed. (laser applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Blue Emission Peak of GeO{sub 2} Particles Grown Using Thermal Evaporation

In this paper we report a simple thermal evaporation technique (horizontal tube furnace) to grow large quantities of GeO{sub 2} particles with diameters ranging from tens of nanometer to 500 nm on n-type (100) Si substrate free of catalyst. The particles were grown at temperature about 1000 degree sign C for 2 hrs and characterized by scanning electron microscopy (SEM), X-Ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDX) and photoluminescence (PL) spectroscopy. The photoluminescence spectrum reveals several emission peaks around 400 nm at room temperature. Raman measurement also measured at room temperature for this GeO{sub 2} particles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Carbon-assisted morphological manipulation of CdS nanostructures and their cathodoluminescence properties

CdS nanostructures with different morphologies and sizes were successfully fabricated through a facile and effective carbon-assisted thermal evaporation method. Through simply changing the positions of silicon substrates, the temperatures and the effects of carbon in different zones were modified, and thus the morphologies of CdS nanostructures were varied from multipods to nanobrushes to nanocups. These nanostructures were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectrometry (EDS), X-ray powder diffraction (XRD) and Raman spectroscopy. Cathodoluminescence (CL) measurement shows that the as-grown CdS nanostructures display different luminescent properties. CdS multipods and nanocups show mainly green emission centered at {approx}496 nm. However, nanobrushes exhibit predominant red emission band peaking at {approx}711 nm. These interesting results show that carbon not only affected the growth process but also influenced the properties of CdS nanostructures. - Graphical abstract: A facile and effective carbon-assisted thermal evaporation method is explored to synthesize CdS multipods, nanobrushes and nanocups. These CdS nanostructures display very different optical properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Triple assembly of ZnO, large-scale hollow spherical shells with flower-like species consisting of rods grown on the outer surfaces of shells

Novel large-scale hollow ZnO spherical shells were synthesized by ionic liquids assisted hydrothermal oxidization of pure zinc powder without any catalyst at a relatively low temperature of 160 deg. C. X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDX) and scanning electron microscopy (SEM) patterns show that the shells are composed of ZnO and the structure of the shells is very unique. Textured flower-like ZnO consisting of ZnO rods is grown on the outer surfaces of shells forming a triple assembly. Room-temperature photoluminescence spectra of the oxidized material show a sharp peak at 379 nm and a wider broad peak centered at 498 nm. The possible growth mechanism of the triple assembly of ZnO is discussed in detail. - Graphical abstract: A proposed growth mechanism of large scale hollow ZnO. Bubbles provide the aggregation center for ionic liquids that leads to the formation of hollow Zn particle-dotted shells, buoyancy promotes shells to go upward, the breach occurs when shells are subjected to overpressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation and up-conversion fluorescence of rare earth (Er{sup 3+} or Yb{sup 3+}/Er{sup 3+})-doped TiO{sub 2} nanobelts

Anatase TiO{sub 2} nanobelts doped with rare earth (RE) ions Yb{sup 3+}, Er{sup 3+} or Yb{sup 3+}/Er{sup 3+} have been prepared using layered titanate nanobelts (LTO NBs) with RE ions as the precursor obtained by ion-exchange between LTO NBs and RE ions under hydrothermal process. Various measurement results demonstrate that the RE ions have doped into the lattice of TiO{sub 2}, and the Er{sup 3+} or Yb{sup 3+}/Er{sup 3+} doped nanobelts show strong visible up-conversion (UC) fluorescence under 980 nm excitation. The UC emission intensity of LTO NBs embedded with Er{sup 3+} or Yb{sup 3+}/Er{sup 3+} is slightly higher than that of the corresponding TiO{sub 2} nanobelts doped with RE ions, whereas higher RE doping content leads to the decrease of UC emission intensity due to the concentration-quenching effect. - Graphical abstract: Anatase TiO{sub 2} nanobelts doped with Er{sup 3+} or Yb{sup 3+}/Er{sup 3+} cations were simply synthesized using two-step preparation proceedings of ion-exchange and hydrothermal treatment, and their upconversion emissions were also investigated. SEM images of TiO{sub 2} nanobelts (NBs) doped with Er{sup 3+} (the left) and codoped with Yb{sup 3+}/Er{sup 3+} (the right).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

CuO-ZnO heterometallic hollow spheres: Morphology and defect structure

The Cu-ZnO hollow spheres, where CuO nanocrystals were dispersed in the shell of ZnO nanoparticals, were synthesized by using highly uniform and monodispersed Cu-embedded carbon spheres as sacrificial templates via a simple route under hydrothermal conditions. The morphology and structure of the spheres were characterized by FTIR, XRD, SEM, TEM and N{sub 2} adsorption-desorption. It was suggested that the OH and C=O groups in the surface of the Cu-embedded carbon spheres facilitated the adsorption of Zn{sup 2+} in the aqueous solution, giving rise to the final CuO-ZnO hollow structure after these Zn{sup 2+}-adsorbed spheres were calcined in air. Moreover, the photoluminescence (PL) study showed that the as-prepared CuO-ZnO hollow spheres and the annealed counterpart exhibited strong and dramatically weakened emissions, respectively. This remarkably different photoluminescent behavior afforded the evidence regarding the oxygen vacancy defects in the CuO-ZnO hollow spheres. - Graphical abstract: CuO-ZnO hollow spheres were obtained using Cu-embedded carbon spheres as template, and the photoluminescent spectra afforded the evidence regarding the oxygen vacancies in the hollow spheres. Highlights: Black-Right-Pointing-Pointer A approach was presented to prepare carbon spheres in a high yield. Black-Right-Pointing-Pointer The fabrication of CuO-ZnO hollow spheres was a simple route. Black-Right-Pointing-Pointer The photoluminescence afforded the evidence of the oxygen vacancies in the hollows. Black-Right-Pointing-Pointer The synthetic approach might be applicable to preparing other hollow structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Environmental Characterization Scans Using Sodium-Iodide Gamma Spectroscopy to Determine Ra-226 Concentration in Surface Soil - 16326

The recent natural gas drilling boom has brought heightened attention to the issue of TENORM waste management. Radioactive residues from the extraction, treatment, and purification of materials containing uranium and thorium, or their progeny, pose a public health hazard primarily in the form of ground water contamination. Hydraulic fracturing can liberate formation waters from shale; the high salinity of which can cause radium to move with the water to the surface. The disposal and handling of this water has been a subject of public controversy. For soil remediation projects, radium-226 is generally one of the radionuclides of concern due to its alpha emissions. However performing a survey scan for Ra-226 is difficult because its photon emissions are low energy and have minimal probability of emission per decay (186.2 keV, 3.3% abundance). Additionally resolving its emission from U-235 (185.7 keV, 57% abundance) with field instrumentation is not feasible. Therefore detection of Ra-226 relies on the presence and photon emissions of its progeny. This paper outlines methodology for calculating the minimum detectable concentration of Ra-226 in characterization scans using a sodium-iodide detector array coupled with a multi-channel analyzer. Using progeny ingrowth as a detection proxy requires knowing decay time in order to determine progeny emission rates. Knowledge of site history, process, and prior survey results can be key in determining an accurate decay time. However in the absence of such information in-situ measurements can be used to estimate decay time by comparing observed progeny emission ratios against established values. These values are determined using Oak Ridge National Laboratory's ORIGEN-ARP program to generate photon energy spectra for Ra-226 and its progeny at specified time intervals. Once decay time is established, the detector's minimum detectable concentration can be calculated by synthesizing the expected emission spectra and Los Alamos National Laboratory's Monte Carlo N-Particle transport code to simulate detector response. Traditionally, one of the steps in calculating a system's minimum detectable concentration is to place an appropriate button source under the detector, record the response, and then move the source by a specified increment. This process is repeated until the detector's spatial efficiency has been mapped. Due to the impracticality of performing this with Ra-226 button sources of varying decay times, Monte Carlo N-Particle transport code was utilized to determine the detector's spatial efficiency. A dime sized source with the established emission spectra was placed into the center of a rectangle of soil. This rectangle, including the source, was used as a lattice element to fill the region of space below the detector. The simulation was designed to track the energy distribution of pulses created in the sodium iodide crystal using the F8 tally, and was setup to isolate each source; thereby correlating detector response to source position. The simulation output required post-processing to determine conversion factors from counts per second to disintegrations per second. Post-processing accounted for subtraction of the Compton continuum, and average the data over the scanning pattern to obtain the expected spatial sensitivity during a characterization study. This was performed for the following photo-peaks: 609 keV (Bi-214), and 1764 keV (Bi-214). For calculation of the scan minimum detectable concentration, the surveyor efficiency coefficient from NUREG 1507 was supplanted in favor of a scan speed deviation factor. This was used because the detector utilizes computerized data collection (spatial and spectral). This report finds that, for two shielded 10.16 cm x 10.16 cm x 40.64 cm sodium-iodide crystals with integrated multi-channel analyzers, the minimum detectable concentration in surface soils is less than 1 pCi per gram Ra-226 for a 1 second survey measurement. These results assume a volumetric source with a maximum depth of 15.24 cm and a minimum decay time of 21 days. Verification of the system's capabilities was performed by sending soil samples from scanned areas, and locations where in-situ measurements were performed, to an independent laboratory for analysis. The laboratory results demonstrated that scanned area was principally comprised of soil containing less than 1 pCi per gram Ra-226. This borders the system MDC and it underestimated the concentration of radium in the soil. The probable causes of this is escape of radon gas from the surface soil. Radon is the daughter of radium, and has a high mobility in soil. If the gas escapes, then the progeny used as the detection proxy will be present in lower than expected concentrations. Radionuclide identification using high volume sodium-iodide crystals in low level characterization scans is demonstrated to be possible. Further system refinement will focus on developing a methodology to estimate a radon escape factor for site specific use. Accounting for radon escape in the top 15.24 cm of soil will allow the system to better estimate Ra-226 concentrations in soil. This is a significant advancement over the gross counting statistics used in most studies to satisfy MARSSIM survey requirements, because it will increase stakeholder confidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A new Scanning Transmission X-ray Microscope at the ALS for operation up to 2500eV

We report on the design and construction of a higher energy Scanning Transmission X-ray Microscope on a new bend magnet beam line at the Advanced Light Source. Previously we have operated such an instrument on a bend magnet for C, N and O 1s NEXAFS spectroscopy. The new instrument will have similar performance at higher energies up to and including the S 1s edge at 2472eV. A new microscope configuration is planned. A more open geometry will allow a fluorescence detector to count emitted photons from the front surface of the sample. There will be a capability for zone plate scanning in addition to the more conventional sample scanning mode. This will add the capability for imaging a massive sample at high resolution over a limited field of view, so that heavy reaction cells may be used to study processes in-situ, exploiting the longer photon attenuation length and the longer zone plate working distances available at higher photon energy. The energy range will extend down to include the C1s edge at 300eV, to allow high energy NEXAFS microscopic studies to correlate with the imaging of organics in the same sample region of interest.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-G-BRA-01: Assessing Radiation-Induced Reductions in Regional Lung Perfusion Following Stereotactic Radiotherapy for Lung Cancer

Purpose: The dose-dependent nature of radiation therapy (RT)-induced lung injury following hypo-fractionated stereotactic RT is unclear. We herein report preliminary results of a prospective study assessing the magnitude of RT-induced reductions in regional lung perfusion following hypo-fractionated stereotactic RT. Methods: Four patients undergoing hypo-fractionated stereotactic lung RT (SBRT: 12 Gy x 4 fractions or 10 Gy x 5 fractions) had a pre-treatment SPECT (single-photon emission computed tomography) perfusion scan providing a 3D map of regional lung perfusion. Scans were repeated 3–6 months post-treatment. Pre- and post SPECT scans were registered to the planning CT scan (and hence the 3D dose data). Changes in regional perfusion (counts per cc on the pre-post scans) were computed in regions of the lung exposed to different doses of radiation (in 5 Gy intervals), thus defining a dose-response function. SPECT scans were internally normalized to the regions receiving <5 Gy. Results: At 3 months post-RT, the changes in perfusion are highly variable. At 6 months, there is a consistent dose-dependent reduction in regional perfusion. The average percent decline in regional perfusion was 10% at 15–20 Gy, 20% at 20–25 Gy, and 30% at 25–30 Gy representing a relatively linear dose response with an approximate 2% reduction per Gray for doses in excess of 10 Gy. There was a subtle increase in perfusion in the lung receiving <10 Gy. Conclusion: Hypo-fractionated stereotactic RT appears to cause a dose-dependent reduction in regional lung perfusion. There appears to be a threshold effect with no apparent perfusion loss at doses <10 Gy, though this might be in part due to the normalization technique used. Additional data is needed from a larger number of patients to better assess this issue. This sort of data can be used to assist optimizing RT treatment plans that minimize the risk of lung injury. Partly supported by the NIH (CA69579) and the Lance Armstrong Foundation.

60 APPLIED LIFE SCIENCES↗

Scanning tunneling microscopy and spectroscopy of the electronic structure of dislocations in GaN/Si(111) grown by molecular-beam epitaxy

By using cross-sectional scanning tunneling microscopy, a correlation between the surface morphology and the corresponding electronic states of the dislocations terminated at the GaN(1100) cleavage surfaces grown by molecular-beam epitaxy has been demonstrated. Both scanning tunneling spectroscopy and analysis of the dislocations on electronic structures suggest that regions surrounding dislocations register gap states in the fundamental band gap of GaN. Closely examining the recognition of the electronic structure reveals that the defect levels could provide the possibility of yellow luminescence, involving a transition from the conduction-band edge to a level at 1.2 eV above the valence band edge.

36 MATERIALS SCIENCE↗

Changes in Global Function and Regional Ventilation and Perfusion on SPECT During the Course of Radiotherapy in Patients With Non-Small-Cell Lung Cancer

Purpose: This study aimed to (1) examine changes in dyspnea, global pulmonary function test (PFT) results, and functional activity on ventilation (V)/perfusion (Q) single-photon emission computerized tomography (SPECT) scans during the course of radiation (RT), and (2) factors associated with the changes in patients with non-small-cell lung cancer (NSCLC). Methods and Materials: Fifty-six stage I to III NSCLC patients treated with definitive RT with or without chemotherapy were enrolled prospectively. Dyspnea was graded according to Common Terminology Criteria for Adverse Events version 3.0 prior to and weekly during RT. V/Q SPECT-computed tomography (CT) and PFTs were performed prior to and during RT at approximately 45 Gy. Functions of V and Q activities were assessed using a semiquantitative scoring of SPECT images. Results: Breathing improved significantly at the third week (mean dyspnea grade, 0.8 vs. 0.6; paired t-test p = 0.011) and worsened during the later course of RT (p > 0.05). Global PFT results did not change significantly, while regional lung function on V/Q SPECT improved significantly after {approx}45 Gy. The V defect score (DS) was 4.9 pre-RT versus 4.3 during RT (p = 0.01); Q DS was 4.3 pre-RT versus 4.0 during RT (p < 0.01). Improvements in V and Q functions were seen primarily in the ipsilateral lung (V DS, 1.9 pre-RT versus 1.4 during RT, p < 0.01; Q DS, 1.7 pre-RT versus 1.5 during RT, p < 0.01). Baseline primary tumor volume was significantly correlated with pre-RT V/Q DS (p < 0.01). Patients with central lung tumors had greater interval changes in V and Q than those with more peripheral tumors (p <0.05 for both V and Q DS). Conclusions: Regional ventilation and perfusion improved during RT at 45 Gy. This suggests that adaptive planning based on V/Q SPECT during RT may allow sparing of functionally recoverable lung tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microbundles of zinc oxide nanorods: Assembly in ionic liquid [EMIM]{sup +}[BF{sub 4}]{sup -}, photoluminescence and photocatalytic properties

A simple, efficient and low-temperature approach for the assembly of hierarchical Zinc oxide (ZnO) microstructures in ionic liquid [EMIM]{sup +}[BF{sub 4}]{sup -} is reported. The as-obtained ZnO superstructures are composed of microbundles of nanorods from the center points, with the diameter and length in the range of 100-150 nm and 2-4 {mu}m, which have been characterized by X-ray diffraction, scanning and transmission electron microscopy, and photoluminescence spectroscopy. The ZnO microstructures exhibit significant defect-related green-yellow emission and high photodegradation of dye Methyl Orange (5x10{sup -5} mol/L) under UV excitation within 80 min. -- Graphical abstract: Easy formation of microbundles of ZnO nanorods were accomplished in low temperature with [EMIM]{sup +}[BF{sub 4}]{sup -} (1-ethyl-3-methylimidazolium tetrafluoroborate) ionic liquid, which exhibit significant green-yellow photoluminescence property and high photodegradation of Methyl Orange dye. Display Omitted Research highlights: {yields} Ionic liquid assisted solid-state route was introduced into synthesis of ZnO nanorods. {yields} The distinctive microbundles ZnO nanorod assembles was evidenced by SEM and TEM. {yields} ZnO nano-material exhibited high efficiency in photodegradation of Methyl Orange.

77 NANOSCIENCE AND NANOTECHNOLOGY↗