Search NASA⌕ Search

SEARCH · Search NASA

Results for “PI control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Closed-Loop Proportional-Integral (PI) Control Software for Fully Mechanically Controlled Automated Electron Microscopic Tomography

A closed-loop proportional-integral (PI) control software is provided for fully mechanically controlled automated electron microscopic tomography. The software is developed based on Gatan DigitalMicrograph, and is compatible with Zeiss LIBRA 120 transmission electron microscope. However, it can be expanded to other TEM instrument with modification. The software consists of a graphical user interface, a digital PI controller, an image analyzing unit, and other drive units (i.e.: image acquire unit and goniometer drive unit). During a tomography data collection process, the image analyzing unit analyzes both the accumulated shift and defocus value of the latest acquired image, and provides the results to the digital PI controller. The digital PI control compares the results with the preset values and determines the optimum adjustments of the goniometer. The goniometer drive unit adjusts the spatial position of the specimen according to the instructions given by the digital PI controller for the next tilt angle and image acquisition. The goniometer drive unit achieves high precision positioning by using a backlash elimination method. The major benefits of the software are: 1) the goniometer drive unit keeps pre-aligned/optimized beam conditions unchanged and achieves position tracking solely through mechanical control; 2) the image analyzing unit relies on only historical data and therefore does not require additional images/exposures; 3) the PI controller enables the system to dynamically track the imaging target with extremely low system error.

Ren, Gang↗

A signal compensation based cascaded PI control for an industrial heat exchange system

Since the characteristics of the industrial heat exchange system (HES) are drastically affected by variations of the steam pressure, ambient temperature and water quality, it is difficult for the classical cascade PI control system to meet the desirable control objectives. Therefore, in this paper, a deterministic linear model with unmodeled dynamics is used to describe the dynamic characteristics of the HES. It should be noted that the unmodeled dynamics at the previously sampled instant can be calculated using actual measurements and that the tracking error, which includes effects of the rate of changes of unmodeled dynamics on the controlled model, can be accurately determined. An additional compensating signal is obtained with the feedforward control together with a one-step optimal control law. Consequently, the cascade PI control strategy with the signal compensation is established. Furthermore, the simulation and industrial application show that the proposed method can effectively improve the performance of the cascade PI control system, especially when the unmodeled dynamics is subjected to unknown variations.

42 ENGINEERING↗

Dynamic Model of Active Front-End Converters with 2DOF-PI Controllers for DC Bus Voltage Control

In most of the research, a conventional one degree-of-freedom type proportional-integral controller (1DOF-PI) is used for the regulation of the dc bus voltage in an Active Front-End Converter (AFEC). This paper proposes a two degree-of-freedom type proportional-integral controller (2DOF-PI) for the regulation of dc bus voltage in an AFEC. Such a controller eliminates the left-half plane (LHP) zero in the command-to-output transfer function for dc bus voltage regulation that is inherent to the conventional 1DOF-PI for this application. The dynamic model of an AFEC in the synchronous reference frame (SRF) is presented. An inner current control and outer dc voltage control loop is built for controlling the AFEC. Vector-control scheme is employed to achieve decoupled control of direct-axis and quadrature-axis currents. The outer dc voltage control loop is designed with a 2DOF-PI to complete the control system. Transfer function (TF) of the controller is derived based on the presented model and used to calculate the controller gains. Transient and steady state performance of the designed controllers are investigated in MATLAB/Simulink and results presented.

Thapa, Anup↗

Feedforward Control of Fuel Distribution on Advanced Dual-Fuel Engines with Varying Intake Valve Closing Timings

This study examines the dynamics and control of an engine operated with late intake valve closure (LIVC) timings in a dual-fuel combustion mode. The engine features a fuel delivery system in which diesel is direct-injected and natural gas is port-injected. Despite the benefits of LIVC and dual-fuel strategy, combining these two techniques resulted in efficiency losses due to the variability of the combustion process across cylinders. The difference in power production across cylinders ranges from 9% at an IVC of 570°ATDC* to 38% at an IVC of 620 °ATDC and indicates an increasingly uneven fuel distribution as the intake valve remains open longer in the compression stroke. This paper describes an approach for controlling the amount of fuel injected into each cylinders’ port of an inline six- cylinder heavy-duty dual-fuel engine to minimize the variations in fuel distribution across cylinder. Since measuring the actual fuel reaching each cylinder is not a practical option on stock engines, this study aimed to produce a feedforward control technique. Using a model developed on an engine simulation software, the optimal fuel injection amounts at each cylinder port across 125 operating conditions (consisting of sweeps of five engine speeds, five engine loads, and five IVC timings) were determined by using PI controllers that adjust the amount of fuel injected at each port based on the amount of fuel reaching the cylinders. The results from the PI controller were expressed as a function of the operating condition (engine speed, engine load, and IVC timing); and consequently, could be reproduced without relying on a measurement of the amount of fuel reaching each cylinder. The feedforward control strategy, unlike the PI controller, is easily implementable on a stock engine and significantly reduces the variations in fuel distribution across cylinders.

Kassa, Mateos↗

Regulation of flow through a T-Shaped open cavity by temperature dependent P, PI, and PID controllers

P (proportional), PI (proportional-integral), and PID (proportional-integral-derivative) controllers are popular means of controlling industrial processes. Due to superior response, accuracy, and stable performance, PID controllers are mostly used in control systems. This paper presents a mathematical model and subsequent response analysis regarding regulation of flow in mixed convection through a T-shaped open cavity by temperature dependent controllers. The T-shaped cavity has cold top and hot bottom walls, while air is flowing through the inlet at surrounding temperature. The inflow is regulated by a controlled gate which operates according to the signal received from the controller. Values of proportional gain (k{sub p}), integral gain (k{sub i}), and derivative gain (k{sub d}) are varied to obtain the desired system response and to ensure a stable system with fastest response. At first, only P controller is used and eventually PI and finally PID control scheme is applied for controller tuning. Tuning of different controllers (P, PI, and PID) are carried out systematically based on the reference temperature which is continuously monitored at a certain location inside the cavity. It is found that PID controller performs better than P or PI controller.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrate FARM with PID controllers: IES Simulation Ecosystem Control System Development

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM was designed to support the HERON software module in the solution of the optimal dispatch problem for IES units. As the result of HERON-FARM dispatch simulation, the set-point trajectories are optimized to meet constraints on both the production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and the process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.) at a coarse time resolution (every 10 or 100 seconds) over long time horizons (several days or weeks). In case the operational constraints need to be met at finer time resolution, the computational burden of HERON-FARM would linearly increase with the sampling rate, and sub-optimal solutions might be obtained. System responses characterized by overshoots and damped oscillations temporarily violating the imposed constraints might occur during abrupt power transients. In this report, a hierarchical control system architecture for the operation of the Dynamic Energy Technology and Integration Laboratory (DETAIL) facility constructed at INL was proposed. First, the preliminary studies on the proposed control strategy for operating the facility and the designed PI controllers were reviewed. In particular, the current approach for generating the set-point trajectories was studied, and its limits were identified. To this aim, the inclusion of a Supervisory Control layer embedding a modified version of the FARM algorithm for preserving the system safe operation over both long and real-time horizons was proposed. In this way, FARM would be applied twice, i.e., the original version (“FARM Validator”) aiding the solution of the power dispatch problem, and the modified version (“FARM Supervisory” coordinating the PI controllers to address the real-time control tasks. Despite the kernel of the two modules is the same algorithm, their roles, tasks, and capabilities are quite different. A detailed description of the role of FARM at addressing low-level control tasks is provided, along with tentative operational procedures for training the models embedded into the algorithm by using the collected experimental data.

42 ENGINEERING↗

Control Improvement for Jump-Diffusion Processes with Applications to Finance

We consider stochastic control problems with jump-diffusion processes and formulate an algorithm which produces, starting from a given admissible control {pi}, a new control with a better value. If no improvement is possible, then {pi} is optimal. Such an algorithm is well-known for discrete-time Markov Decision Problems under the name Howard's policy improvement algorithm. The idea can be traced back to Bellman. Here we show with the help of martingale techniques that such an algorithm can also be formulated for stochastic control problems with jump-diffusion processes. As an application we derive some interesting results in financial portfolio optimization.

97 MATHEMATICS AND COMPUTING↗

Size-resolved Eddy-Covariance Particle Flux Measurement during the TRACER Campaign (Final Report)

The main goal of the TRacking Aerosol Convection interactions ExpeRiment (TRACER) campaign was to study aerosol–cloud interactions during deep convection over the Houston area. This project deployed a suite of instrumentation with the aim to (1) quantify turbulent vertical particle fluxes during at DOE-ARM sites, including TRACER, (2) assess hygroscopic growth factors and hygroscopicity parameters of the material driving modal aerosol growth during new particle formation and growth events, (3) derive turbulent aerosol mass fluxes using co-located Doppler LIDAR measurements, and (4) create quality-controlled PI data products to support future research utilizing data collected during the TRACER campaign. This report summarized the main findings from the deployments at two DOE-ARM sites. Briefly, we found that new particle formation may occur aloft, in a residual layer, near the top of the boundary layer. Small grown particles appear later due to downward mixing with daytime turbulence. The species that are responsible for aerosol modal growth had hygroscopicity parameters varying between 0.05 and 0.34. These values systematically depended on the wind sector, suggesting that the chemical composition of the precursors differed. This work demonstrated that lidar retrievals of the elastic backscatter and Doppler velocity can be used to obtain surface number emissions of particles with a diameter greater than 0.53 µm. During TRACER, emission particle number fluxes peaked near ∼ 100 cm−2 s−1. Multiple quality-controlled PI data products that will support future TRACER related science were generated and made publically available.

54 ENVIRONMENTAL SCIENCES↗

DC Link Voltage Balancing of the Active Front-End for the Extreme Fast Charging Stations

One of the most important challenges of the extreme fast charging (XFC) stations is to balance the DC link voltages of the active front-end (AFE). The multilevel cascaded H-bridge (CHB) converter is a great topology for the AFE applications due to the high power density, low total harmonic distortion (THD), and a low number of active and passive components. In this paper, a technique is proposed for balancing DC-link capacitor voltages of a three-phase CHB converter, when a phase shiftPWM modulation technique is used on all cells of the converter. To reach this goal, the redundant states of the CHB converters are used for generating different AC voltage levels by sorting the voltages of the converters. The proposed voltage balancing technique uses the principles that are employed for the DC link voltage balancing of the low-frequency modulation techniques to balance the DC link voltages of the CHB converter. As shown in this paper, the DC link voltages of the CHB converter can accurately be balanced very fast without using PI controllers, which are used in the conventional DC link voltage balancing techniques. A controller also is proposed which will be used to control the dq currents of the CHB converter. To verify the advantages of the proposed technique, the simulation results of the proposed technique will be carried out in a three-phase 7-cell CHB AFE.

Grid-tied converters, cascaded H-bridge, DC link v↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗

Duty-Cycle Predictive Control of Quasi-Z-Source Modular Cascaded Converter Based Photovoltaic Power System

A duty-cycle predictive control is proposed for dc grid integration of front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The post-stage qZS half-bridge dc-dc converter deals with PV maximum power point tracking, dc grid integration, and dc-link voltage balance; whereas, the front-end isolation converters operate at a constant duty cycle of 50%. Thus, it saves control hardware resources while overcoming challenges from PV-panel voltage variations and dc-bus voltage limit. The proposed control uses the derived circuit model to predict the global active-state duty cycle for grid-connected current control and predict the shoot-through duty cycles for dc-link voltage balance, achieving a fast and accurate tracking target. The proposed control method has advantages of: i) eliminating weighting factors that exist in conventional model predictive control (MPC), ii) no sophisticated loop parameters design that exists in proportional-integral (PI) control, iii) operating at constant switching frequency that is different from the conventional MPC with variable switching frequency. Simulation and experimental tests are carried out to verify the effectiveness of the proposed control method and compare with the PI-based control system.

42 ENGINEERING↗

High-speed spiral imaging technique for an atomic force microscope using a linear quadratic Gaussian controller

This paper demonstrates a high-speed spiral imaging technique for an atomic force microscope (AFM). As an alternative to traditional raster scanning, an approach of gradient pulsing using a spiral line is implemented and spirals are generated by applying single-frequency cosine and sine waves of slowly varying amplitudes to the X and Y-axes of the AFM’s piezoelectric tube scanner (PTS). Due to these single-frequency sinusoidal input signals, the scanning process can be faster than that of conventional raster scanning. A linear quadratic Gaussian controller is designed to track the reference sinusoid and a vibration compensator is combined to damp the resonant mode of the PTS. An internal model of the reference sinusoidal signal is included in the plant model and an integrator for the system error is introduced in the proposed control scheme. As a result, the phase error between the input and output sinusoids from the X and Y-PTSs is reduced. The spirals produced have particularly narrow-band frequency measures which change slowly over time, thereby making it possible for the scanner to achieve improved tracking and continuous high-speed scanning rather than being restricted to the back and forth motion of raster scanning. As part of the post-processing of the experimental data, a fifth-order Butterworth filter is used to filter noises in the signals emanating from the position sensors and a Gaussian image filter is used to filter the images. A comparison of images scanned using the proposed controller (spiral) and the AFM PI controller (raster) shows improvement in the scanning rate using the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Forward Feedback Control Scheme for a Solar Thermochemical Moving Bed Counter-Current Flow Reactor

Abstract Pelletized thermochemical energy storage media has a potential for long-duration energy storage. Production of solid-state energy storage media can be done within a cavity chemical reactor that captures concentrated solar radiation from a solar thermal field. The temperature stability of a solar reactor is directly influenced by the solar flux intercepted. This paper presents a low-order physical model to simulate the dynamic response of temperature inside a tubular plug-flow reactor prototype. Solid granular particles are fed to the reactor from the top whereas a counter-current flowing gas enters the reactor from the bottom. An in-house code was developed to model transient heat transfer of the reactor wall, gas, and moving particles. The model was preliminarily validated with packed beds for different temperature ranges and two gas flowrates. Dynamic response of the reactor temperature is simulated for different input power and gas/particle flowrates. The results show that the system response can be controlled efficiently by utilizing input power (solar flux) as a control parameter. A conventional proportional integral (PI) controller is designed to control the temperature inside the reactor and to maintain it during the solar flux intermittency. The controller parameters are tuned using the Ziegler–Nichols method to ensure optimal system response. The results show that the feedback control model is successful in tracking different reference reactor temperatures within a reasonable settling time of 30 min and eliminated overshoot. This study can be extended to include a hybrid reactor with a multi-input, multi-output variable system.

Energy & Fuels↗

Stacked Low-Inertia Converter or Solid-State Transformer: Modeling and Model Predictive Priority-Shifting Control for Voltage Balance

This paper presents control challenges of stacked low-inertia converter (SLIC) or cascaded reduced dc-link solid-state transformer (SST) and proposes a novel model predictive priority-shifting (MPPS) control with implicit modulator and a discrete-time large-signal model for voltage balancing and dc-link regulation. Low-inertia converters, featuring small electrolytic capacitor-less dc links, dramatically reduce cost, size, and weight compared to conventional solutions. However, without a large dc-link buffer, the input and output are tightly coupled, leading to significant control challenges. The control becomes even more challenging with these converters stacked input-series output-parallel (ISOP) for medium-voltage (MV) grid, which causes coupling between the modules besides the coupling within each module. This paper analyzes the multi-objective, multi-degree of freedom control problem, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. First, distribution of control efforts under controller saturation is critical because multiple control objectives can be conflicting, especially when the module voltages are unbalanced and are being restored. The MPPS can shift the priorities to address this issue. Second, due to the low inertia and high dc-link ripple, classic space vector pulse-width modulation (SVPWM), average model with small-ripple assumption, and control design based on small-signal model cannot accurately modulate, model, and control the nonlinear reduced dc link. Therefore, a discrete-time large-signal model of the M-S4T is established to derive the predictive control in the MPPS. The MPPS and the PI control are compared in MV simulations to show the issue of applying the PI to the SLIC and the effectiveness of the MPPS for voltage balancing and dc-link regulation in a deadbeat manner. Finally, the proposed control is tested on a 5 kV ISOP SiC SST prototype to verify priority shifting to address controller saturation issue and fast and robust voltage balancing.

14 SOLAR ENERGY↗