Effects of the legacy pipe ends on the behaviour of pipe-in-pipe repair systems under internal pressure
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
This work demonstrates various modeling approaches for thermally coupling heat pipes to a graphite monolithic block in a microreactor context, accounting for the presence of a gap. We show that heat pipe model selection has a significant impact on the transient behavior of a three-dimensional coupled microreactor assembly problem by comparing results obtained using different heat pipe models from the heat pipe code Sockeye. Additionally, we show that the choice of coupling strategy has significant consequences for both accuracy and performance. Furthermore, we found that our heat flux transfer strategy exhibited greater accuracy than our temperature transfer strategy, even when comparing a loose coupling of the heat flux transfer strategy to a tight coupling of the temperature transfer strategy. Although this research uses only theoretical test problems, it provides important insights in modeling thermal fluids phenomena in heat pipe microreactors.
Our team has developed a comprehensive solution for performing in-situ structural repairs on metal piping and pipelines. This is based on a multifaceted and integrated (experimental and computational) approach, that uses a slurry-based coating and our patented high temperature sintering process, to build new metal in a pipe-in-pipe configuration. This can be utilized in either a complete pipe-in-pipe embodiment, or for patch repairs.
This paper discusses steps taken to size a thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal FEA is used to determine optimum heat transfer coefficient of convective boundaries. Geometric details of fin-based surface area enhancement required to reach target combined overall heat transfer coefficient (U) and surface area (A) performance (UA) in W/K, is worked out for relevant boundaries and the resulting UA is verified in 3D thermal FEA. Thermal management system's UA (by extension specific power) sensitivity to coolant temperature is explored and temperature distribution plots of optimized machine components are presented and discussed.
Not Available
Not provided.
Microreactors are being researched, designed, and built at Idaho National Laboratory (INL). Microreactors are small reactors defined at less than 20MW of power. These reactor concepts are also being looked at throughout industry for various applications. An important aspect of these reactor designs is economic feasibility i.e. lower overnight capital cost. The driving factors for implementing microreactors are quick setup and takedown, minimal operators, and the ability to manufacture them readily and to fit in mid-sized containers for transport. A specific area of research to aid in successful integration of these factors within the designs is passive heat removal of the core’s thermal power. Interest in heat pipes to achieve this passive heat removal has been shown across multiple industry partners. Because of this interest, INL has developed a test facility to facilitate experimental tests for sodium filled heat pipes. INL has developed the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility to run experiments on high performance, sodium filled heat pipes. As mentioned above, heat pipes are passive heat transfer devices. Radially, heat pipes are broken up into an outer wall, a small annular gap, a wick structure, and a centerline gap. They function by utilizing latent heat transfer. Heat pipes are traditionally separated into three regions, an evaporator (heat input), an adiabatic region, and finally a condenser region (heat removal). As heat is being applied to the evaporator, the working fluid undergoes a phase change to a vapor. This phase change causes a differential pressure across the axial length of the pipe driving flow down the center gap of the heat pipe. The vapor flows down past the adiabatic region to the condenser where the heat is removed. This heat removal forces the working fluid to phase change back to a liquid. The wick structure is then utilized to drive the flow back towards the evaporator by capillary forces. This backflow is aided by the annular gap. Because this heat transfer mechanism functions with latent heat transfer, the heat pipe is close to isothermal down the axial length. Heat pipes can operate under a wide range of working fluids. Considerations for these working fluids are primarily driven by operating temperatures amongst other important factors based around overall performance. Sodium filled heat pipes operate from 450°C up to 900°C. This temperature range works well for the current microreactor designs. In conjunction with this experimental capability, INL has developed a modeling software to simulate heat pipe physics within reactor cores. This modeling software is called Sockeye and functions under the established INL Multiphysics Object Oriented Simulation Environment (MOOSE). SPHERE also supports Sockeye development by providing the modeling team with experimental data on an array of setups and operating parameters to support validation efforts. A power transient experiment was performed utilizing the SPHERE facility to continue to aid with Sockeye development. The testing followed a proposed test plan to ramp up and down the temperature of the heat pipe. Sockeye models steady state heat pipe operation with high accuracy, the data provided by the power transient testing aims to assist with the validation efforts and further enhance transient modeling capability of the tool [2].
The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho Na- tional Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1000 hours, as a test of detrimental, long-term effects of heat pipe operation. The setup consists of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic fiber heater configuration and cooled via a water-cooled calorimeter. Measurements include temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, this data is utilized to validate heat pipe models in the heat pipe application Sockeye, which is based upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment in SPHERE using various heat pipe models with Sockeye, including heat conduction-based models and compressible flow models of the heat pipe interior. These models are compared to the experimental data to assess the accuracy of several aspects of heat pipe modeling, including frozen startup, the effect of non-condensable gases, and the coupling of the heat pipe to its environment.
The burst pressure of line pipes is an important strength property required in pipeline design and integrity management. Historically, the Barlow formula in conjunction with the ultimate tensile stress (UTS) of pipeline steels were utilized to estimate the burst strength of line pipes. However, the Barlow formula did not consider the plastic flow effect for ductile steels and is applicable only to thin-walled pipes. In 2006, the present author proposed a new multiaxial plastic yield theory and obtained a theoretical Zhu-Leis solution of burst strength for defect-free thin-walled pipes in term of UTS and strain hardening exponent n of pipeline steels. The Zhu-Leis solution has been validated by various burst test data for thin-walled pipelines for a wide range of steel grades from Grade B to X120. Recently, the present author extended the Zhu-Leis theory of plasticity to thick-walled pipes and obtained the Zhu-Leis solution of burst pressure for thick-walled pipes. The proposed burst pressure solution is applicable to both thin and thick-walled pipes. To experimentally validate the proposed theoretical burst pressure solution, this paper obtains a set of burst test data for three thick-walled pipes in Grade B carbon steel with a nominal diameter of 2.375 inches and three nominal wall thicknesses, resulting in D/t = 15.4, 10.9, 6.9. Through comparisons, these burst data validate the theoretical burst pressure solution for thick-walled pipes. Moreover, two additional burst test datasets collected from literature for thin and thick-walled pipes further validate the proposed burst pressure solution for both thin and thick-walled pipes.
Heat pipe microreactors are reactor designs that primarily use liquid-metal heat pipes to cool the core. The main interest in heat pipes is the fact that they can remove heat passively. This, along with the use of liquid metal, allows the reactor to operate at higher temperatures. Although the use of heat pipes in nuclear reactors is new, liquid-metal heat pipe technology is mature. Nevertheless, experimental data on heat pipes are scarce, and very little is known about their behavior during abnormal operations and close to their thermal limits. Therefore, new experiments and accurate heat pipe simulations are needed to develop reliable closure models. This work describes a joint experimental and numerical investigation into heat pipes that attempts an initial closure of this gap. Further, the numerical and experimental efforts are currently proceeding in parallel, aimed at different aspects of heat pipes. The numerical part is focused on gaps in local closures, and the experiments capture the overall heat pipe behavior.
The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho National Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1,000 hours to test the detrimental, long-term effects of heat pipe operation. The setup consisted of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic-fiber heater configuration and cooled via a water-cooled calorimeter. Measurements included temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, we use this data to validate heat pipe models in Sockeye, a heat pipe application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment at SPHERE using various heat pipe models with Sockeye, including heat-conduction-based and compressible flow models of the heat pipe interior.
This Phenomena Identification and Ranking Table (PIRT) report provides an evaluation of key phenomena affecting the performance and operational regimes of heat pipes, particularly in the context of heat pipe microreactors (HPMRs). Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in the heat pipe, including phase change, turbulent transition, and compressibility effects, among others, there is high uncertainty in identifying and ranking the important phenomena affecting the operation of heat pipes and the current knowledge for their modeling and simulation and experimental measurements and instrumentation. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. The report analyzes phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics, discussing challenges and future research directions for improving their modeling and simulation and experimental measurements. Additionally, the report addresses phenomena with low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geysering, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. This comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.
Heat pipes play a critical role in determining the operations, safety, and energy efficiency of electronics. The main focus to improve the heat pipe performance is on the evaporator design or wicking structures. However, the intrinsic limitation comes from the condenser, which is fundamentally constrained by inefficient filmwise condensation (FWC). In this study, we successfully achieved a peak effective thermal conductivity (k eff ) of ~140 kW/(m·K) on widely used groove heat pipes by implementing sustainable dropwise condensation (DWC) and integrating with enhanced evaporator. To better understand the working mechanisms of the ultraefficient heat pipe, both the evaporator and condenser of the heat pipes have been modified accordingly. Our results show that up to 296% enhancements on the k eff can be achieved under various inclination angles by only inducing DWC in the condenser section. The drawback of temperature fluctuations induced by DWC in smooth heat pipes appears to be effectively solved using the grooves-wicking structure. Furthermore, by integrating the nanostructured evaporator, the k eff of the heat pipe can be boosted up to 517% compared to conventional groove heat pipes. This study, for the first time, demonstrates the huge potential of engineering both the condenser and evaporator simultaneously in developing ultraefficient heat pipes.
Microreactor technologies are required to provide reliable carbon-free power generation in remote applications. The heat pipe cooled microreactor concept in particular offers notable advantages due to the passive operation of heat pipes enabling increased reliability and simplicity in a more compact form factor. There is a significant need for experimental work to aid and expedite the deployment of heat pipe microreactors due to their unique technological characteristics. Thus, there has been increased interest in heat pipe experiments by numerous institutions in order to support these efforts. The present work is a comprehensive review of heat pipe experiments, describing instrumentation, methods, phenomena of interest, and recent developments. In addition, legacy work on the operation of high-temperature heat pipes under irradiation is reviewed and discussed. Furthermore, the verification and validation efforts for the flagship heat pipe simulation code Sockeye are reviewed and requirements for future experiments are outlined. Lastly, future directions are proposed for heat pipe experimentation.
Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.
This research effort focuses on the development of a pipe crawler inspection tool for fossil energy power plants. The pipe crawler is tethered and can navigate through 2 inch pipes that are often found in various systems within a power plant. The crawler can navigate through straight pipes and 180 degree elbows and includes instrumentation that can assess the integrity of the pipes. The sensors include a UT sensor for measuring the thickness of the pipe, a range finder and a camera. An additional module is used to prep the surface of the pipe prior to taking thickness measurements. Both bench scale and engineering scale testing was conducted to demonstrate the concept. Multiple crawlers were created and tethered together to distribute the load of the tether so that the crawler can navigate longer pipe distances.
Pipe-type cable systems, including high-pressure fluid-filled (HPFF) and high-pressure gas-filled cables, are widely used for underground high-voltage transmission. These systems consist of insulated conductor cables within steel pipes, filled with pressurized fluids or gases for insulation and cooling. Despite their reliability, faults can occur due to insulation degradation, thermal expansion, and environmental factors. As many circuits exceed their 40-year design life, efficient fault localization becomes crucial. Fault location involves prelocation and pinpointing. Therefore, a novel pinpointing approach for pipe-type cable systems is proposed, utilizing accelerometers mounted on a steel pipe to capture fault-induced acoustic signals and employing the time difference of arrival method to accurately pinpoint the location of the fault. The experimental investigations utilized a scaled-down HPFF pipe-type cable system setup, featuring a carbon steel pipe, high-frequency accelerometers, and both mechanical and capacitive discharge methods for generating acoustic pulses. The tests evaluated the propagation velocity, attenuation, and pinpointing accuracy with the pipe in various embedment conditions. The experimental results demonstrated accurate fault pinpointing in the centimeter range, even when the pipe was fully embedded, with the acoustic pulse velocities aligning closely with the theoretical values. These experimental investigation findings highlight the potential of this novel acoustic pinpointing technique to improve fault localization in underground systems, enhance grid reliability, and reduce outage duration. Further research is recommended to validate this approach in full-scale systems.