Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA FOCUS DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Physical Reasoning to Synchronize Electrical Signals and Related Diagnostics in Plasma Focus Devices

Plasma Focus (PF) devices as well as other similar pulsed discharge devices requires a variety of diagnostics for their proper control and optimization, including the voltage between electrodes, the time derivative of the discharge current, detection of X-rays and neutron emissions, and pulsed laser images (Shadow, Schlieren, interferograms). This article discusses the problem of the time reference of all these outputs and proposes specific techniques for synchronizing them based on sound physical grounds. The foundations of synchronization criterion are verified in several experiments on PF devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current sheath behavior and its velocity enhancement in a low energy Mather-type plasma focus device

The dynamics of the plasma sheath layer and its velocity enhancement have been studied in a low energy (4.9 kJ) Mather-type plasma focus device. Experiments were performed to study the effect of the Lorentz force variation on the current sheath expansion and movement, as well as the existence of traction between all parts of the sheath layer. Two different shape of anodes (cylindrical and step) along with an axial magnetic probe were used to investigate the effects of various experimental conditions, namely different charging voltages and gas pressures. In order to explore the upper limit of the current sheath velocity, a comparison has been made between the experimental data gathered by the probe and the Lee's computational model. The limitations governing the enhancement of the current sheath velocity that can lead to the deterioration of a good focusing phenomenon were also investigated. The increase of the current sheath velocity due to the usage of the step anode on ion generation and hard x-ray emissions have been demonstrated by means of an ion collector and a hard x-ray detector.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Results Of A 600 Joules Small Plasma Focus Device

Preliminary results of a 600 J (3.7 muF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled in a knife-edge design and a set of coaxial plasma gun are attached to it in order to initiate the breakdown and enhance the current sheath formation. The experiments have been performed in argon gas under a low pressure condition of several microbars. The discharge current and the voltage across the electrodes during the discharge are measured with high voltage probe and current coil. The current and voltage characteristics are used to determine the possible range of operating pressure that gives good focusing action. At a narrow pressure regime of 9.0+-0.5 mubar, focusing action is observed with good reproducibility. Preliminary result of ion beam energy is presented. More work will be carried out to investigate the radiation output.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-to-Pinch Investigation of 5 kJ Mather-Type Plasma Focus Device

The Egyptian Atomic Energy Authority-Plasma focus (EAEA-PF2) has been upgraded to a 5 kJ plasma focus device. Its characteristics have been investigated at various pressures and different voltages in a 5 kJ Mather-type plasma focus device for Ar gas. Its time-to-pinch has been measured, simulated and analyzed at different operating conditions. It is observed from the results that, the time-to-pinch decreased when either the charging voltage increased or the gas pressure decreased. In addition, the time-to-pinch is estimated theoretically using Lee model RADPF5.15. A comparison between the experimental and theoretical time-to-pinch is discussed. Also, the drive factor of plasma focus is analyzed at different pressures and charging voltages. It is noticed that, the mass and current factors are affected by changing the pressure and voltage. Finally, it is observed that, the drive factor is proportional inversely to the pressure and directly to the charging voltage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

External circuit integration with electromagnetic particle in cell modeling of plasma focus devices

The pinch performance of a plasma focus (PF) device is sensitive to the physical conditions of the breakdown phase. It is therefore essential to model and study the initial phase in order to optimize device performance. An external circuit is self consistently coupled to the electromagnetic particle in cell code to model the breakdown and initial lift phase of the United Nations University/International Centre for Theoretical Physics (UNU-ICTP) plasma focus device. Gas breakdown during the breakdown phase is simulated successfully, following a drop in the applied voltage across the device and a concurrent substantial rise in the circuit current. As a result, the plasma becomes magnetized, with the growing value of the magnetic field over time leading to the gradual lift off of the well formed current sheath into the axial acceleration phase. This lifting off, with simultaneous outward sheath motion along the anode and vertical cathode, and the strong magnetic fields in the current sheath region, was demonstrated in this work, and hence validates our method of coupling the external circuit to PF devices. Our method produces voltage waveforms that are qualitatively similar to the observed experimental voltage profiles of the UNU-ICTP device. Values of the mean electron energy before and after voltage breakdown turned out to be different, with the values after breakdown being much lower. In both cases, the electron energy density function turned out to be non-Maxwellian.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of Nitrogen on Hydrogenated Amorphous Carbon Thin Films Deposited by Plasma Focus Device

To carry out our research, a plasma focus device is used to deposit thin films of nitrogen doped hydrogenated amorphous carbon (a-C:H:N) onto the stainless steel-AISI-304 substrates at room temperature. Thin films are deposited with the same numbers of focus shots, at the same distance from the anode tip and with different partial pressures of nitrogen in the mixtures of acetylene/nitrogen as working gas. The nitrogen contents of deposited films are studied using nuclear reaction analysis (NRA) techniques. The results prove that nitrogen contents of the samples do not increase significantly by increasing partial pressure of nitrogen of the working gas for both sets of the samples. Moreover, NRA results exhibit the limitation of nitrogen incorporated into the samples, when this experimental setup is used. G-peak position and peak intensity ratio of the D-band to G-band (I{sub D}/I{sub G}) are used to investigate the diamond characters. Also, they show that sp{sup 2} clustering is highly dependent on the nitrogen atomic contents and angular position of the samples. Scanning electron microscopy (SEM) shows the granular surface morphology of the films. Furthermore, it shows that angular position of the samples with respect to the anode axis plays an important role in the grain size of the surface of the samples. The thickness of the films decreases significantly by increasing angular position of the samples, while it decreases slightly by increasing partial pressure of nitrogen of the working gas. The Vickers surface hardness of the thin films exhibits significant dependency on the sp{sup 2} clustering.

36 MATERIALS SCIENCE↗

Interaction of the high energy deuterons with the graphite target in the plasma focus devices based on Lee model

Numerical experiments are systematically carried out using the Lee model code extended to compute the ion beams on various plasma focus devices operated with Deuterium gas. The deuteron beam properties of the plasma focus are studied for low and high energy plasma focus device. The energy spectral distribution for deuteron ions ejected from the pinch plasma is calculated and the ion numbers with energy around 1 MeV is then determined. The deuteron–graphite target interaction is studied for different conditions. The yield of the reaction {sup 12}C(d,n){sup 13}N and the induced radioactivity for one and multi shots plasma focus devices in the graphite solid target is investigated. Our results present the optimized high energy repetitive plasma focus devices as an alternative to accelerators for the production of {sup 13}N short lived radioisotopes. However, technical challenges await solutions on two fronts: (a) operation of plasma focus machines at high rep rates for a sufficient period of time (b) design of durable targets that can take the thermal load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron production from puffing deuterium in plasma focus device

The current research has continued on the PF-1000 plasma focus device at the current of 2 MA by comparison of the shots with and without injected deuterium. The increase of the total neutron yield at the level of 10{sup 10}–10{sup 11} per shot was achieved after the compression of about 10 μg/cm of the deuterium from the gas-valve by about 46 μg/cm of the neon or deuterium plasma sheath. It increases five times at the decrease of the puffing deuterium mass to one-half. In shots with neon in the chamber and with puffing deuterium, a considerable decrease was confirmed of the soft X-ray emission in comparison with shots without deuterium injection. This decrease can be explained by the absence of the neon in the region of the compressed and hot plasma. The deuterium plasma from the gas-puff should then be confined in the internal structures both in the phase of implosion as well as during their formation and transformation. In shots with puffing deuterium, the evolution of instabilities in the plasma column was suppressed. The deuterium plasma has a higher conductance and better ability to form expressive and dense plasmoids and to transport the internal current in comparison with neon plasma. Neutrons were produced both at the initial phase of stagnation, as well as at a later time at the evolution of the constrictions and dense plasmoids.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative study of radiation emission without and with target in a 2.2 kJ plasma focus device

The radiation emission in a 2.2 kJ Mather-type dense plasma focus device is investigated using a five channel BPX65 PIN diode spectrometer. Estimated X-ray associated with the hollow anode without and with target in Argon gas medium is compared. At optimum conditions, the radiation emission from the system is found to be strongly influenced with target in hollow anode and the filling gas pressure. The maximum X-ray yield in 4π sr was obtained in case of hollow anode in argon gas medium with target 'Lead' due to interaction of electron beam. Results indicated that an appropriate design of hollow anode with target could enhance the radiation emission by more intense interaction of expected electron beam with target. The outcomes are helpful in designing a plasma focus with enhanced X-ray radiation with improved shot to shot reproducibility in plasma focus device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study on neutron emission from 2.2 kJ plasma focus device

The neutron emission from a low energy (2.2 kJ) plasma focus device operated in deuterium medium has been investigated by employing photo-multiplier tube (PMT) and bubble dosimeter. The neutron emission is found to be pressure dependent and anisotropic in nature. In most cases of plasma focus shots, the PMT signal shows double pulses of neutron emission with different intensities and widths. An interesting relation between intensity of hard X-ray and neutron emission is also observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temporal and spatial study of neon ion emission from a plasma focus device

The temporal and spatial characteristics of the neon ion beam emissions from a low energy plasma focus device have been studied by employing a multiple Faraday cup assembly and the CR-39 track detectors at different angular and axial positions. In addition, the operating gas pressures were also varied to study the temporal and spatial characteristics of the neon ion beam emissions. The Faraday cup analyses show that the ion flux strongly depends on the operating gas pressure as well as the angular positions. The estimated ion energy measurements at the aperture of the Faraday cup indicate that the plasma focus device is a source of polyenergetic ions ranging from approximately a few keV to a few hundreds of keV, irrespective of the angular positions. The exposed CR-39 detectors have shown the formation of multiple ion tracks with diameter ranging from 2 to 13 {mu}m. The populations of lower diameter tracks (2-6 {mu}m) are observed to be more at 0 deg. and 10 deg. angles. It is also noticed that the most populated track counts have shifted toward the higher diameter as the angular positions change from 0 deg. to 70 deg. The present study enables us to predict a clear picture of ion flux and energy distribution inside the plasma focus chamber that will help to use the device for material irradiation application in a more controlled manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics of ion beam generated from a Mather type plasma focus device

Diagnostics of ion beam emission from a 3 kJ Mather-type plasma focus device have been performed for deuterium discharge at low pressure regime. Deuterium plasma focus was found to be optimum at pressure of 0.2 mbar. The energy spectrum and total number of ions per shot from the pulsed ion beam are determined by using biased ion collectors, Faraday cup, and solid state nuclear track detector CR-39. Average energy of the ion beam obtained is about 60 keV. Total number of the ions has been determined to be in the order of 10{sup 11} per shot. Solid state nuclear track detectors (SSNTD) CR39 are employed to measure the particles at all angular direction from end on (0°) to side on (90°). Particle tracks are registered by SSNTD at 30° to 90°, except the one at the end-on 0°.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of a 500-kJ Mather-type plasma focus device

In this article, design of a 500-kJ Mather-type plasma focus device to achieve 10{sup 11} neutrons/shot is reported. One of its important characteristics is the triple-part anode design. The anode is surrounded by an alumina insulator. The second part of the anode is changeable in order to locate cylindrical, conical, or other shapes of pieces mounted on it. This geometry leads to the easier investigation of the neutron and X-ray emissions of the device. The third part of the anode is for changing the materials exposed to different kinds of radiations. The design parameters are considered by semiempirical and empirical formulas and are sketched by Solidworks software. Also, the peak current and neutron yield are estimated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study of the performance of a very small repetitive plasma focus device in different working conditions

SORENA-1 is a very small repetitive Mather-type plasma focus device (20 J) that can operate at frequencies up to 1 Hz. This device has been designed and constructed in the Plasma and Nuclear Fusion Research School of the Nuclear Science and Technology Research Institute of Iran. In this article, the structure of SORENA-1 is described and results of experiments with Ar, Ne, and D{sub 2} working gases at several discharge voltages and initial pressures are presented and analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Palm top plasma focus device as a portable pulsed neutron source

Development of a palm top plasma focus device generating (5.2 {+-} 0.8) Multiplication-Sign 10{sup 4} neutrons/pulse into 4{pi} steradians with a pulse width of 15 {+-} 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 {mu}F capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 {mu}F, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of {sup 3}He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

43 PARTICLE ACCELERATORS↗

Neutron and high energy deuteron anisotropy investigations in plasma focus device

The anisotropies of neutron and high energy deuteron emissions from the NX2 plasma focus device [M. V. Roshan et al., Phys. Lett. A 373, 851 (2009)] are studied. The nuclear activation of graphite targets is used to measure the fluences of high energy deuterons in the axial and radial directions. Two bismuth germanate scintillation detectors connected to multichannel analyzer systems are used for the detection of 511 keV gamma rays resulting from positron annihilation in the two targets. In addition, fast neutron activation detectors are employed to measure the axial and radial fluences of fusion neutrons. These detection systems are calibrated using the simulation code MCNPX[L. S. Waters et al., AIP Conf. Proc. 896, 81 (2007)]. Two distinct regimes of neutron and deuteron anisotropies are observed for the NX2 device. For deuterium gas pressures below 10 mbar, the neutron anisotropy increases with increasing pressure, while the overall neutron yield remains low. For gas pressures of 10-14 mbar, the neutron anisotropy is essentially constant, while, with increasing pressure, the neutron yield rises rapidly and the deuteron anisotropy falls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current sheath formation dynamics and structure for different insulator lengths of plasma focus device

The breakdown phase of the UNU-ICTP plasma focus (PF) device was successfully simulated using the electromagnetic particle in cell method. A clear uplift of the current sheath (CS) layer was observed near the insulator surface, accompanied with an exponential increase in the plasma density. Both phenomena were found to coincide with the surge in the electric current, which is indicative of voltage breakdown. Simulations performed on the device with different insulator lengths showed an increase in the fast ionization wave velocity with length. The voltage breakdown time was found to scale linearly with the insulator length. Different spatial profiles of the CS electron density, and the associated degree of uniformity, were found to vary with different insulator lengths. The ordering, according to the degree of uniformity, among insulator lengths of 19, 22, and 26 mm agreed with that in terms of soft X-ray radiation yield observed from experiments. This suggests a direct correlation between CS density homogeneity near breakdown and the radiation yield performance. These studies were performed with a linearly increasing voltage time profile as input to the PF device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The study of pinch regimes based on radiation-enhanced compression and anomalous resistivity phenomena and their effects on hard x-ray emission in a Mather type dense plasma focus device (SABALAN2)

In this study, by using argon and nitrogen as the filling gases in a Mather type dense plasma focus device at different values of pressure and charging voltage, two different kinds of pinch regimes were observed for each of the gases. The physics of the pinch regimes could be explained by using the two versions of the Lee's computational model which predicted each of the scenarios and clarified their differences between the two gases according to the radiation-enhanced compression and, additionally, predicted the pinch regimes through the anomalous resistivity effect during the pinch time. This was accomplished through the fitting process (simulation) on the current signal. Moreover, the characteristic amplitude and time scales of the anomalous resistances were obtained. The correlations between the features of the plasma current dip and the emitted hard x-ray pulses were observed. The starting time, intensity, duration, and the multiple or single feature of the emitted hard x-ray strongly correlated to the same respective features of the current dip.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗