Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparative analyses of plasma probe diagnostics techniques

The subject of this paper is a comparative analysis of the plasma parameters inferred from the classical Langmuir probe procedure, from different theories of the ion current to the probe, and from measured electron energy distribution function (EEDF) obtained by double differentiation of the probe characteristic. We concluded that the plasma parameters inferred from the classical Langmuir procedure can be subjected to significant inaccuracy due to the non-Maxwellian EEDF, uncertainty of locating the plasma potential, and the arbitrariness of the ion current approximation. The plasma densities derived from the ion part of the probe characteristics diverge by as much as an order of magnitude from the density calculated according to Langmuir procedure or calculated as corresponding integral of the measured EEDF. The electron temperature extracted from the ion part is always subjected to uncertainty. Such inaccuracy is attributed to modification of the EEDF for fast electrons due to inelastic electron collisions, and to deficiencies in the existing ion current theories; i.e., unrealistic assumptions about Maxwellian EEDFs, underestimation of the ion collisions and the ion ambipolar drift, and discounting deformation of the one-dimensional structure of the region perturbed by the probe. We concluded that EEDF measurement is the single reliable probe diagnostics for the basic research and industrial applications of highly non-equilibrium gas discharge plasmas. Examples of EEDF measurements point up importance of examining the probe current derivatives in real time and reiterate significance of the equipment technical characteristics, such as high energy resolution and wide dynamic range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma probe

Mariner IV plasma probe to measure density, velocity distribution, and bulk direction of proton flux component of solar plasma - components, operation, and performance

MARINER IV SPACE PROBE↗

A Multi-ring Ionospheric Plasma Probe

An ionospheric plasma probe was constructed which consists of a long cylinder with the end facing the flow closed by an end plate made up of multiple annular rings and a center disk. A theoretical argument is given which yields the plasma potential and electron temperature in terms of known plasma parameters and the currents to the various rings of the end plate. This probe was successfully operated in an ionospheric flow simulation facility and the resulting plasma potential is in excellent agreement with the traditional Langmuir analysis (1.22 volts).

Sheldon, J. W.↗

Two plasma probe techniques

Annotated bibliography on two plasma probe techniques using plasma resonance probe, and Langmuir probe

LANGMUIR PROBE↗

Single shot high bandwidth laser plasma probe

Herein a novel scheme to probe a plasma's ion acoustic resonances in single shot high-bandwidth pump-probe experiments is proposed. Our design utilizes concepts similar to smoothing by spectral dispersion; however, we propose a method of applying the bandwidth to the probe that avoids the effects of angular dispersion. Theoretical modeling and fluid simulations of the interaction are presented and compared. The results show the possibility of recovering a plasma's full complex index of refraction in a single shot pump-probe experiment. This wavelength dependent refractive index is directly related to the plasma's particle distribution function and can be used to recover plasma parameters including electron and ion temperatures, electron density, and plasma flow velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion sheath effects on RF plasma probes - Experimental results in laboratory plasmas

Laboratory work dealing with the frequency characteristic of the plasma impedance of spherical and cylindrical electrode systems is reported. The influence of the ion sheath on various features of the impedance characteristic is emphasized. Those features are the series and parallel resonance as well as additional resonances due to the excitation of electroacoustic and cyclotron harmonic waves. The dependence of the series and parallel resonances on dc biasing leads to a method of determining the ion sheath capacity for a cylindrical electrode system. The obtained values agree fairly well with those obtained from a theoretical model for the density and potential distribution in the sheath of a cylindrical sensor aligned with a supersonic plasma flow. The amplitude of resonances due to excitation of longitudinal plasma waves (electroacoustic and cyclotron harmonic) is reduced or even vanishes for sufficiently negative dc bias. Positive bias first leads to an increased amplitude up to a certain dc bias value above which, however, the amplitude decreases again due to electron absorption at the sensor surface.

Kist, R.↗

Plasma probe.

Physical description, module fabrication, sensor construction and calibration details of plasma probe carried on Mariner IV

PROTON ENERGY↗

PLASMA PROBE INSTRUMENTATION ON EXPLORER X

Plasma proton probe instrumentation of explorer x, giving essential features enabling it to measure arrival direction and energy distribution of photons

EXPLORER X SATELLITE↗