SURFACE FINISHING AND ELECTROLESS NICKEL PLATING OF ADDITIVELY MANUFACTURED (AM) METAL COMPONENTS

This study investigates the application of electroless nickel deposition on additively manufactured stainless steel samples. Current additive manufacturing (AM) technologies produce metal components with a rough surface. Rough surfaces generally exhibit fatigue characteristics, increasing the probability of initiating a crack or fracture to the printed part. For this reason, the direct use of as-produced parts in a finished product cannot be actualized, which presents a challenge. Post-processing of the AM parts is therefore required to smoothen the surface. This study analyzes chempolish (CP) and electropolish (EP) surface finishing techniques for post-processing AM stainless steel components CP has a great advantage in creating uniform, smooth surfaces regardless of size or part geometry EP creates an extremely smooth surface, which reduces the surface roughness to the sub-micrometer level. In this study, we also investigate nickel deposition on EP, CP, and as-built AM components using electroless nickel solutions. Electroless nickel plating is a method of alloy treatment designed to increase manufactured component's hardness and surface resistance to the unrelenting environment. The electroless nickel plating process is more straightforward than its counterpart electroplating.. We use low-phosphorus (2-5% P), medium-phosphorus (6-9% P), and high-phosphorus (10-13% P). These Ni deposition experiments were optimized using the L9 Taguchi design of experiments (TDOE), which compromises the prosperous content in the solution, surface finish, plane of the geometry, and bath temperature. The pre-and post-processed surface of the AM parts was characterized by KEYENCE Digital MicroscopeVHX-7000 and Phenom XL Desktop SEM. The experimental results show that electroless nickel deposition produces uniform Ni coating on the additively manufactured components up to 20 μm per hour. Mechanical properties of as-built and Ni coated AM samples were analyzed by applying a standard 10 N scratch test. Nickel coated AM samples were up to two times scratch resistant compared to the as-built samples. This study suggests electroless nickel plating is a robust viable option for surface hardening and finishing AM components for various applications and operating conditions.

Keywords: additive manufacturing, fatigue, chempol↗

Plenum plate standoff spools for separating a pair of plenum plates in a nuclear reactor

A nuclear reactor has first and second plenum plates disposed in a pressure vessel. Both plenum plates have a plurality of apertures. The second plenum plate is parallel to the first plenum plate. A fuel element includes a fuel element coolant flow tube which extends through aligned apertures of the parallel plenum plates. A fuel element standoff spool is disposed about a portion of the fuel element coolant flow tube which is located between the plenum plates. The nuclear reactor is also usable in nuclear thermal propulsion.

Inman, James B.↗

Copper Outdiffusion from Copper-Plated Solar Cell Contacts during Damp Heat Exposure

Plated copper (Cu) contacts for silicon (Si) solar cells are an attractive alternative material to conventional screenprinted silver, but there are unresolved questions on the long-term integrity of plated contact structures. Here, in this work, we perform characterization on plated Cu contacts from encapsulated cells that were degraded during extended exposure to damp heat (DH) stress. First, using energy-dispersive X-ray spectroscopy, we find evidence of Cu outdiffusion upward through capping layers made of both tin and silver applied with light-induced plating, resulting in a layer of Cu on the outer contact surface. We hypothesize that if Cu is mobile in the module, it may eventually find some route by which to enter the Si cells where it can degrade performance. Subsequently, in several types of Cu-plated, DH-degraded cells, secondary ion mass spectrometry detects elevated levels of Cu at the Si surface and in the Si cell bulk, which suggests that Cu can indeed migrate from contacts into Si over the course of DH stress.

14 SOLAR ENERGY↗

Evaluation of residual stresses in isothermal friction stir welded 304L stainless steel plates

Friction stir welding was performed on 304L SS plates in order to heal simulated cracks created by electrical discharge machining. Two different tool temperatures (825 and 725 °C) were chosen for this study. Both neutron diffraction and X-ray diffraction techniques were employed to evaluate the residual stresses along two orthogonal reference directions, longitudinal (syy) and transverse (sxx). The former technique was also used to measure residual stresses at various depths. It was found that, at 1 mm depth from the top surface inside the stir zone (SZ), the longitudinal component was tensile in nature while the transverse component was compressive. The nature and magnitude of the residual stress fields, and the position of the peak residual stresses were found to vary with the weld depth. The SZ of the 725 °C weld exhibited higher peak stress than 825 °C weld mainly due to a lack of stress relief at the lower temperature.

Friction stir welding, Steel↗

Experimental Insights into the Coupling of Methane Combustion and Steam Reforming in a Catalytic Plate Reactor in Transient Mode

The microstructured reactor concept is very promising technology to develop a compact reformer for distributed hydrogen generation. In this work, a catalytic plate reactor (CPR) is developed and investigated for the coupling of methane combustion (MC) and methane steam reforming (MSR) over Pt/Al 2 O 3 -coated microchannels in cocurrent and counter-current modes in transient experiments during start-up. A three-dimensional (3D) computational fluid dynamics (CFD) simulation shows uniform velocity and pressure distribution profiles in microchannels. For a channel velocity from 5.1 to 57.3 m/s in the combustor, the oxidation of methane is complete and self-sustainable without explosion, blow-off, or extinction; nevertheless, flashbacks are observed in counter-current mode. In the reformer, the maximum methane conversion is 84.9% in cocurrent mode, slightly higher than that of 80.2% in counter-current mode at a residence time of 33 ms, but at the cost of three times higher energy input in the combustor operating at ~1000 °C. Nitric oxide (NO) is not identified in combustion products, but nitrous oxide (N 2 O) is a function of coupling mode and forms significantly in cocurrent mode. Furthermore, this research would be helpful to establish the start-up strategy and environmental impact of compact reformers on a small scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fresnel zone plate point spread function approximation for zeroth order mitigation in millimetric field of view x-ray imaging

High spatial and temporal resolution x-ray radiography images are required at the National Ignition Facility (NIF) for high-energy density experiments. One technique that is in development to achieve the required resolution uses Fresnel zone plate (FZP) optics to image an object that is backlit by an x-ray source. The multiple FZP diffraction orders do not focus on the same plane, which increases the background and reduces the contrast. Understanding the point spread function of the different diffraction orders will allow the prediction of the expected background using simulations. We find that the two-dimensional point spread function of the FZP can be approximated by the addition of a sharp Gaussian with a disk. This allowed for the estimation of the background in NIF experimental images of Rayleigh–Taylor spikes and their interpretation. An alternative design of FZP is discussed to allow the inclusion of a zeroth order blocker to reduce the background.

Do, A. (ORCID:0000000174372147)↗

3D printed micro channel plate, method of making and using 3D printed micro channel plate

The invention provides a gain device having a plurality of channels having a polygonal shape with four or more sides. The invention also provides a method for producing microchannel plates (MCPs) having the steps of providing a pre-polymer; and directing a laser over the pre-polymer into a pre-determined pattern. Also provided is method for efficiently 3D printing an object.

36 MATERIALS SCIENCE↗

Tuning the Solvation Structure in Aqueous Zinc Batteries to Maximize Zn-Ion Intercalation and Optimize Dendrite-Free Zinc Plating

Aqueous zinc batteries are recognized to suffer from H + /Zn 2+ coinsertion in the cathode, but few approaches have been reported to suppress deleterious H + intercalation. We realize this goal by tuning the solvation structure, using LiV 2 (PO 4 ) 3 (LVP) as a model cathode. Phase conversion of LVP induced by H + intercalation is observed in 4 m Zn(OTf) 2 , whereas dominant Zn 2+ insertion is confirmed in a ZnCl 2 water-in-salt electrolyte (WiSE). This disparity is ascribed to the complete absence of free water and a strong Zn 2+ –H 2 O interaction in the latter that interrupts the H 2 O hydrogen bonding network, thus suppressing H + intercalation. On the basis of this strategy, a novel PEG-based hybrid electrolyte is designed to replace the corrosive ZnCl2 WiSE. This system exhibits an optimized Zn 2+ solvation sheath with a similar low free water content, showing not only much better suppression of H + intercalation but also highly reversible Zn plating/stripping with a CE of ~99.7% over 150 cycles.

25 ENERGY STORAGE↗

Failure investigation and mitigation after experimental research reactor fuel plate deformation in an irradiation device

Experimental research reactor fuel testing is conducted in the Belgian Reactor 2 (BR2) of the Belgian Nuclear Research Centre (SCK CEN) in dedicated irradiation vehicles or rigs. One such vehicle allows flat full-size fuel plates to be irradiated by inserting them into slotted baskets that captures a narrow portion of the longitudinal edges of the plates. The motion of the fuel plates within the baskets is possible within the narrow slots and thus, the plate is considered to be unattached. The design intentionally omits fixing mechanisms of the fuel plates to the baskets to facilitate the inspection and repositioning of the plates between the irradiation cycles and the accommodation of thermal expansion of the plates in the lateral direction. However, loosely inserted fuel plates have weak structural boundary conditions allowing for larger out-of-plane deflections caused by hydrodynamic loads exerted by the flowing coolant, as compared to those of fixed plates. Unexpected large deformations of plates occurred in several irradiation cycles that further resulted in a loss of cladding integrity. These deformations could not be attributed to a single source. This triggered a series of thermal hydraulic, structural, and fluid-structure interaction analyses aiming at understanding the observed phenomenon. The analyses revealed that, for a certain combination of unfavorable manufacturing and assembly tolerances, fuel plate edges could escape out of the slots in the irradiation basket due to the hydrodynamic load. Subsequently, the plate could become wedged inside the basket coolant channel opening. This resulted in reduced coolant flow and accelerated temperature increase and thermal expansion of the plate while under irradiation. This unfavorable feedback loop could then lead to excessive plate surface temperatures, deformed plates and cladding failure, as was observed in the experiments. These analyses not only provided a probable cause of the fuel plate failures, but also resulted in a new and improved design of the irradiation basket to avoid these issues in the future. In conclusion, a series of recent successful irradiations confirm that the sources of failures were identified correctly, and the implemented mitigations were adequate.

BR2↗

Interfacial Analysis of Blister Formation in U-10Mo Mini-Plates

A thorough investigation of potential failure mechanisms builds confidence in the performance of monolithic U-10wt%Mo (U-10Mo) fuel plates. The lowenriched uranium (LEU) fuel system is currently undergoing qualification as a high U-density fuel that can be used to convert United States high-performance research reactors from high-enriched uranium (HEU) operation. This will require establishing fuel operational limits such that fission products and a coolable geometry are retained, even during off-normal reactor operation conditions [1]. Such off-normal conditions can subject the fuel plates to temperatures where the internal pressure of precipitated fission gasses result in a permanent deformed, raised area of the cladding, referred to as a blister. These blisters can reduce the local coolability of a fuel plate and can even close coolant channels of a fuel assembly, so blistered plates are considered failed regardless of whether the fuel is truly breached. Historically, a marginto- failure is established through out-of-pile blister threshold testing of irradiated fuel plates. This is accomplished by incrementally heating irradiated fuel plates until blisters are observed. This reveals the temperature threshold that would have resulted in a blister if a plate experienced them at those irradiation conditions [2]. While the blister testing itself reveals the temperatures at which the cladding mechanical integrity was exceeded, a more thorough investigation of the interface evolution in proximity to formed blisters may reveal mechanisms as to the blister formation and retention of fission gases. Previous studies have explored potential underlying mechanisms in historical plates that may have been close to blistering [3]; however, this work is the first exploration of blister tested irradiated plates, fabricated by a commercial vendor—another requirement for qualification of the fuel system [1]. The Mini-plate 1 (MP-1) experiment was the first in a series of irradiation and post-irradiation examination (PIE) campaigns to qualify the U-10Mo monolithic fuel system. It consisted of commercially fabricated 25.4×101.5 mm Al-clad mini-plates with a monolithic U-10Mo foil coated in a Zr diffusion barrier. The primary MP-1 PIE campaign was previously completed. Among the suit of examinations was a blister testing campaign, where plates were incrementally annealed in 25°C increments until blisters were observed or a maximum temperature of 550°C was reached [4]. The previously blistered plates from this campaign were revisited in this work.

25228↗

National Spherical Torus eXperiment - Upgrade NSTX-U: Structural Analysis of Passive Plates Support Brackets

The objective of this analysis is to estimate and assess the stresses in the passive plates caused by a limiting plasma disruption. The objective of this calculation is also to address observed damage to mounting hardware after completion of NSTX operation. These observations initiated diagnostic efforts during the Upgrade project to monitor the severity of the disruptions that were causing the damage, and planned instrumentation to trend the behavior of the mounting hardware. The Recovery Project mission for the passive plate hardware is to appropriately reinforce the passive plates with stainless steel ribs mounted on the back of the plate to reduce their flexure and stress and reinforcements of the “biscuit” components of the bracketry to transfer loads without damage to bolts, biscuits, and bracket plates and welds. Mid-plane disruptions and quenches were manageable with NSTX vintage hardware. The Vertical Displacement Event (VDE) disruptions position the plasma closer to the passive plates and are more severe than the centered plasma. Earlier work pointed to the P1-P5 VDE as limiting. This has been confirmed by A. Brooks work in support of the load generation effort in reference. During vertical displacement large counter currents are generated in the plate as the plasma approaches it. - as would be expected from passive plates. When the plasma disrupts the currents in the plates are reversed, which also reverses the loading on the plates. This report documents the methodology and results of transient structural analysis on the plasma, passive plates support brackets. The loads induced by eddy and halo currents have been considered, and were generated using a separate electromagnetic analysis (NSTXU_1_11_2_1_CALC_051). The structural model also incorporates the effects from preload. Calculation was performed with the assumption that existing biscuits are not participating in the load bearing except the biscuits connected to jumper bolts, which are fully engaged. Results show that with the planned reinforcements, Passive plates and mounting structures satisfy static and fatigue criteria in all areas except welds, where separate analysis was performed. Both symmetric and asymmetric (with locating block) designs were analyzed, and although stresses were higher without locating block they still satisfy NSTX design criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel 3D Force Sensors for a Cost-Effective 3D Force Plate for Biomechanical Analysis

Three-dimensional force plates are important tools for biomechanics discovery and sports performance practice. However, currently, available 3D force plates lack portability and are often cost-prohibitive. To address this, a recently discovered 3D force sensor technology was used in the fabrication of a prototype force plate. Thirteen participants performed bodyweight and weighted lunges and squats on the prototype force plate and a standard 3D force plate positioned in series to compare forces measured by both force plates and validate the technology. For the lunges, there was excellent agreement between the experimental force plate and the standard force plate in the X-, Y-, and Z-axes (r = 0.950–0.999, p < 0.001). For the squats, there was excellent agreement between the force plates in the Z-axis (r = 0.996, p < 0.001). Across axes and movements, root mean square error (RMSE) ranged from 1.17% to 5.36% between force plates. Although the current prototype force plate is limited in sampling rate, the low RMSEs and extremely high agreement in peak forces provide confidence the novel force sensors have utility in constructing cost-effective and versatile use-case 3D force plates.

42 ENGINEERING↗

Fluid structural interaction simulation of the MP-1 plate performance irradiated in the advanced test reactor

Due to the high neutron fluxes they generate and increased heat transfer performance, plate type fuels are used in the U.S. high-performance research reactors. During irradiation, a significant amount of fission energy (i.e., ~200 MeV per atom) is released by the U-235 chain reaction that is carried away by the coolant. Through thermal hydraulic analysis, the coolant’s heat transfer capability is investigated to ensure that the desired fuel temperature can be maintained. At high temperatures, the plate undergoes elastic/plastic deformation, creep, and swelling as a result of both the temperature gradients and the fission gas production within the fuel. These effects are studied via fuel performance analysis. When the plate deformation is small enough that the coolant flow remains relatively unchanged, conducting these two types of analyses independently will suffice. But at high fuel burnups, the swollen plates may encroach into the coolant channels that separate the fuel plates from each other and cause these channels to narrow. Large reductions in channel gap size imperil cooling performance, causing fuel temperatures to rise. Further, if the plate deformation is asymmetric, the fuel centerline will shift toward one side of the channel, causing an uneven reduction in coolability. In addition, a boehmite (oxide) layer will, over time, grow on the plate surface, further obstructing the heat transfer process. To precisely predict fuel temperatures/deformation, a complete coupled analysis that considers coolant flow, heat transfer, oxide growth, elastic/plastic deformation, creep, and swelling is needed; however, this type of analysis method is not available in the literature. To fill the gap, this research developed a fluid structure interaction (FSI) approach to the fuel plate analysis, then successfully applied it to the Mini-Plate (MP)-1 experiment, which was irradiated in the Advanced Test Reactor (ATR) for both one and two cycles. The complete analysis coupled STAR-CCM+, a computational fluid dynamic (CFD) software for calculating flow, with Abaqus, a finite element analysis code for calculating plate deformation. Improvements in the results were found when comparing the fully coupled analysis to the independently conducted analyses but they were not significant due to the miniature size of the plates and the relatively short irradiation time. In the future, the fully coupled approach presented herein will be applied to full-size fuel plates with longer irradiation cycles once additional experiments become available.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Operando detection of Li plating during fast charging of Li-ion batteries using incremental capacity analysis

A major challenge that limits fast charging of Li-ion batteries is lithium (Li) plating on the graphite electrode. Furthermore, it remains challenging to detect and diagnose Li plating in operando during charging. In this work, incremental capacity (IC) analysis is applied while charging graphite-NMC pouch cells over a range of rates from C/2 to 4C. Three-electrode pouch cell measurements and post-mortem SEM imaging was performed to demonstrate that the onset of Li plating is correlated with a specific IC peak. IC analysis was also applied to study the fast-charge performance of multi-layer pouch cells with 3-D anode architectures. The results demonstrate that: 1) IC curves have a characteristic peak that is an indicator of Li plating during fast charging, which grows in magnitude as charging rate increases; 2) the plating IC peak correlates with the voltage minimum of the graphite anode, indicating a transition from intercalation to plating; 3) the plating IC peak is sensitive to small amounts of Li plating; 4) IC analysis can be applied to study Li plating in novel cell architectures; 5) the plating IC peak evolves during extended fast-charge cycling, which is a result of reduced Li plating as the Li inventory decreases.

25 ENERGY STORAGE↗