Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLEXIGLAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modeling and Validation of Damped Plexiglas Windows for Noise Control

Windows are a significant path for structure-borne and air-borne noise transmission in general aviation aircraft. In this paper, numerical and experimental results are used to evaluate damped plexiglas windows for the reduction of structure-borne and air-borne noise transmitted into the interior of an aircraft. In contrast to conventional homogeneous windows, the damped plexiglas windows were fabricated using two or three layers of plexiglas with transparent viscoelastic damping material sandwiched between the layers. Transmission loss and radiated sound power measurements were used to compare different layups of the damped plexiglas windows with uniform windows of the same nominal thickness. This vibro-acoustic test data was also used for the verification and validation of finite element and boundary element models of the damped plexiglas windows. Numerical models are presented for the prediction of radiated sound power for a point force excitation and transmission loss for diffuse acoustic excitation. Radiated sound power and transmission loss predictions are in good agreement with experimental data. Once validated, the numerical models were used to perform a parametric study to determine the optimum configuration of the damped plexiglas windows for reducing the radiated sound power for a point force excitation.

Buehrle, Ralph D.↗

Noise Transmission Characteristics of Damped Plexiglas Windows

Most general aviation aircraft utilize single layer plexiglas material for the windshield and side windows. Adding noise control treatments to transparent panels is a challenging problem. In this paper, damped plexiglas windows are evaluated for replacement of conventional windows in general aviation aircraft to reduce the structure-borne and airborne noise transmitted into the interior. In contrast to conventional solid windows, the damped plexiglas window panels are fabricated using two or three layers of plexiglas with transparent viscoelastic damping material sandwiched between the layers. Results from acoustic tests conducted in the NASA Langley Structural Acoustic Loads and Transmission (SALT) facility are used to compare different designs of the damped plexiglas panels with solid windows of the same nominal thickness. Comparisons of the solid and damped plexiglas panels show reductions in the radiated sound power of up to 8 dB at low frequency resonances and as large as 4.5 dB over a 4000 Hz bandwidth. The weight of the viscoelastic treatment was approximately 1% of the panel mass. Preliminary FEM/BEM modeling shows good agreement with experimental results for radiated sound power.

Gibbs, Gary P.↗

Effects of pressure, oxygen concentration, and forced convection on flame spread rate of Plexiglas, Nylon and Teflon

Experiments were conducted in which the burning of cylindrical materials in a flowing oxidant stream was studied. Plexiglas, Nylon, and Teflon fuel specimens were oriented such that the flames spread along the surface in a direction opposed to flowing gas. Correlations of flame spread rate were obtained that were power law relations in terms of pressure, oxygen concentration, and gas velocity.

Notardonato, J. J.↗

Damped Windows for Aircraft Interior Noise Control

Windows are a significant path for structure-borne and air-borne noise transmission into aircraft. To improve the acoustical performance, damped windows were fabricated using two or three layers of plexiglas with transparent viscoelastic damping material sandwiched between the layers. In this paper, numerical and experimental results are used to evaluate the acoustic benefits of damped windows. Tests were performed in the Structural Acoustic Loads and Transmission Facility at NASA Langley Research Center to measure the transmission loss for diffuse acoustic excitation and radiated sound power for point force excitation. Comparisons between uniform and damped plexiglas windows showed increased transmission loss of 6 dB at the first natural frequency, 6 dB at coincidence, and 4.5 dB over a 50 to 4k Hz range. Radiated sound power was reduced up to 7 dB at the lower natural frequencies and 3.7 dB over a 1000 Hz bandwidth. Numerical models are presented for the prediction of radiated sound power for point force excitation and transmission loss for diffuse acoustic excitation. Radiated sound power and transmission loss predictions are in good agreement with experimental data. A parametric study is presented that evaluates the optimum configuration of the damped plexiglas windows for reducing the radiated sound power.

Buehrle, Ralph D.↗

Radiation in controlled environments: influence of lamp type and filter material

Radiation in controlled environments was characterized using fluorescent and various high-intensity-discharge (HID) lamps, including metal halide, low-pressure sodium, and high-pressure sodium as the radiation source. The effects of water, glass, or Plexiglas filters on radiation were determined. Photosynthetic photon flux (PPF, 400 to 700 nm), spectra (400 to 1000 nm), shortwave radiation (285-2800 nm), and total radiation (300 to 100,000 nm) were measured, and photosynthetically active radiation (PAR, 400 to 700 nm) and longwave radiation (2800 to 100,000 nm) were calculated. Measurement of PPF alone was not an adequate characterization of the radiation environment. Total radiant flux varied among lamp types at equal PPF. HID lamps provided a lower percentage of longwave radiation than fluorescent lamps, but, when HID lamps provided PPF levels greater than that possible with fluorescent lamps, the amount of longwave radiation was high. Water was the most effective longwave radiation filter. Glass and Plexiglas similarly filtered longwave more than shortwave radiation, but transmission of nonphotosynthetic shortwave radiation was less with Plexiglas than glass. The filter materials tested would not be expected to influence photomorphogenesis because radiation in the action spectrum of phytochrome was not altered, but this may not be the only pigment involved.

NASA Discipline Life Support Systems↗

Designing, Modeling, Constructing, and Testing a Flat Panel Speaker and Sound Diffuser for a Simulator

The goal of this project was to design, model, build, and test a flat panel speaker and frame for a spherical dome structure being made into a simulator. The simulator will be a test bed for evaluating an immersive environment for human interfaces. This project focused on the loud speakers and a sound diffuser for the dome. The rest of the team worked on an Ambisonics 3D sound system, video projection system, and multi-direction treadmill to create the most realistic scene possible. The main programs utilized in this project, were Pro-E and COMSOL. Pro-E was used for creating detailed figures for the fabrication of a frame that held a flat panel loud speaker. The loud speaker was made from a thin sheet of Plexiglas and 4 acoustic exciters. COMSOL, a multiphysics finite analysis simulator, was used to model and evaluate all stages of the loud speaker, frame, and sound diffuser. Acoustical testing measurements were utilized to create polar plots from the working prototype which were then compared to the COMSOL simulations to select the optimal design for the dome. The final goal of the project was to install the flat panel loud speaker design in addition to a sound diffuser on to the wall of the dome. After running tests in COMSOL on various speaker configurations, including a warped Plexiglas version, the optimal speaker design included a flat piece of Plexiglas with a rounded frame to match the curvature of the dome. Eight of these loud speakers will be mounted into an inch and a half of high performance acoustic insulation, or Thinsulate, that will cover the inside of the dome. The following technical paper discusses these projects and explains the engineering processes used, knowledge gained, and the projected future goals of this project

Dillon, Christina↗

Dielectric loaded aperture antennas.

This paper describes a primarily experimental study of the effect of placing dielectric obstacles having various geometries directly upon the aperture of circular and rectangular waveguide antennas. It is found that plexiglas spheres, and in some cases plexiglas cubes, one to four wavelengths in dimension, produce directive patterns with low sidelobes. The measured gain in some cases is 6 dB greater than the gain of an optimum horn having an equal aperture size.

Croswell, W. F.↗

Circumnutation augmented in clinostatted plants by a tactile stimulus

Dark-grown, 4-day old, Helianthus annuus seedlings were rotated for 20 hr on horizontal clinostats to minimize the amplitude of circumnutation. Then a Plexiglas sheet was placed gently against the tip of the cotyledons. By time-lapse video imaging (using intermittent IR illumination to which the plants were insensitive) movements of the clinostatted plants were observed before, during, and after the period of mechanical contact. Immediately after the Plexiglas sheet was removed residual nutation increased in amplitude almost three-fold, then declined over the next 7 hr to the prestimulation level. This demonstration of enhancement of circumnutation by mechanical contact is consistent with the model of an endogeneous oscillator that can be stimulated by factors other than gravity.

Chapman, D. K.↗

Application of image processing technology to problems in manuscript encapsulation

The long term effects of encapsulation individual sheets of the Codex Hammer were investigated. The manuscript was simulated with similar sheets of paper which were photographed under repeatable raking light conditions to enhance their surface texture, encapsulated in plexiglas, cycled in an environmental test chamber, and rephotographed at selected intervals. The film images were digitized, contrast enhanced, geometrically registered, and apodized. An FFT analysis of a control sheet and two experimental sheets indicates no micro-burnishing, but reveals that the ""mesoscale'' deformations with sizes 8mm are degrading monotonically, which is of no concern. Difference image analysis indicates that the sheets were increasingly stressed with time and that the plexiglas did not provide a sufficient environmental barrier under the simulation conditions. The relationship of these results to the Codex itself is to be determined.

Glackin, D. L.↗

Test results of the SHARE II Mid-deck Flight Experiment

The SHARE II (Space Station Advanced Radiator Experiment II) Mid-deck Experiment was flown on board the Space Shuttle (STS-37) from April 5 to 12, 1991. The purpose of the experiment was to demonstrate the operation of several design changes proposed for the NASA/Grumman SHARE II heat pipe as a result of the lessons learned during the first SHARE flight (STS-29) in March 1989. Two test articles flew during the mission. The first, the Bubble Management Test Article, was a Plexiglas model of the monogroove heat pipe. This test article was primarily used to evaluate the performance of two 0-g bubble management devices; the redesigned evaporator screen artery and the condenser bubble trap. The second, the Blended Manifold Priming Test Article, also constructed of Plexiglas, was used to demonstrate passive self-priming of a heat pipe blended manifold connecting three evaporator legs to a single condenser leg. Both test articles used a 50/50 mixture of ethanol and water as the working fluid. Overall, the experiment was highly successful, with all the major test objectives fulfilled, including blended manifold priming, condenser bubble trap operation, screen artery bubble ingestion, and elimination of hydraulic diameter mismatch.

Brown, Richard F.↗

Observations on Cavitation Damage in a Flowing System

Cavitation damage to specimens of stainless steel, carbon steel, aluminum, and plexiglas, placed in a cavitating venturi using water and mercury as test fluids is mostly in the form of irregularly shaped pits which do not change with additional exposure to the cavitating field within the limited durations utilized. The rate of damage is very high initially, decreases for a relatively short period of time, then increases again up to the maximum test durations of 150 hours with water and 270 hours with mercury. Observation of damage effects by several independent techniques, using a variety of specimen materials, with two different fluids under various fluid dynamic conditions, leads to a suggested correlating model in terms of the cavitation bubble density and energy and specimen material strength.

VENTURI TUBE↗

Pulsed electromagnetic gas acceleration

Experimental data were combined with one-dimensional conservation relations to yield information on the energy deposition ratio in a parallel-plate accelerator, where the downstream flow was confined to a constant area channel. Approximately 70% of the total input power was detected in the exhaust flow, of which only about 20% appeared as directed kinetic energy, thus implying that a downstream expansion to convert chamber enthalpy into kinetic energy must be an important aspect of conventional high power MPD arcs. Spectroscopic experiments on a quasi-steady MPD argon accelerator verified the presence of A(III) and the absence of A(I), and indicated an azimuthal structure in the jet related to the mass injection locations. Measurements of pressure in the arc chamber and impact pressure in the exhaust jet using a piezocrystal backed by a Plexiglas rod were in good agreement with the electromagnetic thrust model.

Jahn, R. G.↗

Combustion anomalies in stop-restart firing of hybrid rocket engines

An experimental investigation of the restart process of an oxygen-Plexiglas hybrid rocket demonstrated that preheating the fuel (as a consequence of a previous ignition and a temporary extinguishment) significantly increases the rate of chamber pressurization and produces regression rate overshoots during reignition. Higher rates of chamber pressurization measured during the restart transient imply faster instantaneous regression rates of the fuel during restart. Transient periods following the initial ignition and the restart after a two-second shutdown were observed for four experimental tests. Thermocouples were embedded in the fuel to record subsurface temperature histories. A mathematical model of the thermal processes in the fuel and the events that occur during an experimental firing was developed to calculate the regression rate transients. Quantitative agreement with experimental results was obtained by making nominal corrections to the calculated convective and radiative heating rates.

Saraniero, M. A.↗