At least 19 records

Utilization of traceable standards to validate plutonium isotopic purification and separation of plutonium progeny using AG MP-1M resin for nuclear forensic investigations

Radio-chronometric studies on plutonium (Pu) materials require independent measurement of the Pu (parent) content and isotopic distribution as well as concentration and isotopic distribution of the plutonium isotopic decay products. We performed a series of experiments to demonstrate the consistency of separations using the Lewatit MP 800 macroporous anion exchange resin and the AG MP-1M resin with traceable Pu isotopic certified reference material (CRM) standards 136, 137, 138, and 126-A. Two different mesh-sizes of the AG MP-1M resin were tested and the 50–100 mesh size resin was found to work more efficiently for the separation task. Both Lewatit and AG MP-1M resins were found to perform satisfactorily for quantitatively extracting the americium (Am) and uranium (U) progeny as well as gallium (Ga) present as a tracer in the Pu material. Both resins were effective in removing isobaric interferences from the Pu fraction used in isotopic measurements by thermal ionization mass spectrometry (TIMS). To address the co-elution of uranium and gallium, Alizarin red S (ARS) was used as a colorimetric dye to determine the behavior of UO 2 2+ and Ga 3+ on AG MP-1M resin with various acidic solutions as eluents using UV–vis spectra. Poor resolution of these peaks complicated quantitative analysis by UV–vis spectroscopy, but these results were informative in planning automated separation experiments by HPLC. LA-UR-24-28919.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗

Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm 2 ), and delivers solvent (2% HNO 3 ) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition ( 240 Pu/ 239 Pu and 242 Pu/ 239 Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240 Pu/ 239 Pu ratio on all three CRMs and <10% for the 242 Pu/ 239 Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240 Pu/ 239 Pu and <15% for the 242 Pu/ 239 Pu. Method limits of detection were determined, based on measurements of an enriched 244 Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

A Robust Assessment of High-Precision Plutonium Isotopic Analysis by Thermal Ionization Mass Spectrometry [Slides]

TIMS at SRNL • SRNL consolidated analytical laboratories and services into one area – loss of TIMS capability during relocation. • SRNL installed a new Thermo Scientific TRITON Plus TIMS in our Category II Nuclear Facility to re-establish the lab’s TIMS capabilities in Feb. 2024. • Allows for handling, preparation, purification, and analysis of high-level radiological materials within a single location • Pu and U isotopic composition and assay measurement qualification have been priority since installation. • Once the instrument has been qualified, this capability will support internal and external customers.

07 ISOTOPE AND RADIATION SOURCES↗

Production of NBL PO plutonium isotopic standards CRM 136A, CRM 137A, and CRM 138A

Lawrence Livermore National Laboratory (LLNL) produced approximately 1 mg units of purified Pu from the parent New Brunswick Laboratory (NBL) certified reference materials (CRM) 137, 136 and 138 isotopic standards for the NBL Program Office (NBL PO) as detailed in the revised project plan. As stated in the plan, three representative units of each material were dispensed at the same time to be characterized at LLNL and provide informational values for the quantity of Pu and progeny nuclides in each unit. NBL PO intends to collect and evaluate isotopic measurement data from multiple laboratories and certify these materials as new isotopic standards C137A, C136A, and C138A, respectively. Soon after production eleven units of each analytical standard were shipped to other analytical laboratories for the certification effort, and 121, 119, and 119 units of C137A, C136A and C138A, respectively were shipped to Mickey Finch at Y12 NBL distribution center in November 2024 (30-gallon drum, TID 003777 PRL 7000005043). Residual purified Pu from the effort is being stored indefinitely in B332 at LLNL. Detailed methods can be found in the production plan, and this report describes and documents aspects of the production effort that are not in or were modified from the original production plan.

and nuclear chemistry↗

Gamma ray analysis of the K2 containers

The K2 containers contain PuO2 with 238 Pu being the most abundant isotope of all plutonium isotopes. The purpose of this analysis is to determine the light element impurities in the PuO2. These light elements can interact with the alpha particles from plutonium decay to release gamma rays, protons, and neutrons through the reactions (α,α’), (α,p), and (α,n) respectively. The gamma rays released by the interactions can be measured and compared with the gamma rays released by the plutonium. The ratios of the gamma rays from the interactions and the plutonium gamma rays allow for the determination of the impurities in the items. The elements that can be detected are Lithium (Z=3), Beryllium (Z=4), Boron (Z=5), Fluorine (Z=9), Sodium (Z=11), Magnesium (Z=12), Aluminum (Z=13), Silicon (Z=14), Phosphorous (Z=15), Chlorine (Z=17), and Potassium (Z=19).

07 ISOTOPE AND RADIATION SOURCES↗

New NBL Pu Isotopic Standards C137A and C136A as Working Reference Materials for Radiochronometry in Nuclear Forensics

Lawrence Livermore National Laboratory (LLNL) and the NBL Program Office (NBL PO) are collaborating on production of purified sub-units of the former NBS 936, 937 and 938 plutonium isotopic reference materials, which will be certified for plutonium isotopic composition and sold as certified reference materials (CRMs) C136A, C137A, and C138A, respectively. These reference materials are used throughout the United States and international community as standards for isotopic measurement method calibration and quality control and were first produced over 50 years ago. To reduce quantities of in-grown daughter products and potentially enable their use as Pu radiochronometry reference materials, the materials undergo a two-stage anion exchange purification to significantly reduce the quantities of U, Am, and Np in the source material. The purified Pu is aliquoted into ~1 mg units in the nitrate form, which will facilitate easier shipping and use compared to the 0.25 g parent units. The production process has been completed for the high- and medium- burnup isotopic standards C137A and C136A and will soon be performed for the weapons-grade Pu standard C138A. This report describes the measurement of trace actinide progeny of the Pu isotopes ( 234 U, 235 U, 236U, 241 Am and 237 Np) in purified C137A and 136A isotopic standards to provide informational values and assess the possibility of their use as working reference materials for radiochronometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NWAL Validation Report for U Assay by Potentiometric Titration (Modified Davies and Gray Technique) and U and PU Assay by Isotope Dilution Mass Spectrometry

SRNL Sensing & Metrology, previously Analytical Laboratory, is a member of the IAEA Network of Analytical Laboratories for Nuclear Material Measurement that is qualified to provide Uranium and Plutonium isotopic analysis of nuclear materials by Thermal Ionization Mass Spectrometry. As part of the membership, SRNL participated in the 2019 Nuclear Material Round Robin to maintain the qualification to provide isotopic analysis. SRNL also participated with the additional intent to qualify Uranium Assay by Potentiometric Titration (Davies and Gray method) and Uranium and Plutonium Isotope Dilution by Thermal Ionization Mass Spectrometry as part of the International Atomic Energy Agency’s Network of Analytical Laboratories. The proficiency test exercise was conducted by the Office of Safeguards Analytical Services, Department of Safeguards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biogeochemistry of Pond B (Savannah River Site, South Carolina, USA): Water column and Sediments

Pond B at Savannah River Site (SRS, South Carolina) is a monomictic reservoir that received SRS R reactor cooling water from 1961–1964. Previous studies conducted between the 1980s–1990s on the water column and sediments of Pond B measured trace amounts of Pu (33 MBq 238Pu and 430 MBq 239,240Pu), 241Am, and 137Cs. Since then, the pond has been relatively isolated and the radionuclide concentrations have not been monitored over time. Herein, about 30 years after the last publication on Pond B, we are re-evaluating the geochemistry and radionuclide distribution within Pond B at five locations along a horizontal transect from the inlet to outlet. In addition, we are conducting the first analysis of the microbial community composition. This data package consists of water column measurements (1) using a multi-probe sonde, (2) plutonium isotopes and total concentrations, (3) total organic/inorganic carbon concentrations, (4) trace metals and major ions concentrations, and (6) microbial community composition. Sediment measurements include (1) plutonium isotopes and total concentrations and (2) microbial community composition.For sediment core and porewater, please see other Pond B data package (ess-dive-60d2352a4495472-20200615T203925174).The data in this package will be submitted for peer review in 2023.

54 ENVIRONMENTAL SCIENCES↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Isotopic analysis of plutonium measured with very thick absorbers and high-granularity spectra

FRAM is LANL-designed software designed to extract plutonium and uranium isotopic information from gamma ray spectra. This is an important capability for NEST and STAB; however, FRAM performance has been poor when applied to field data collected in these programs. FRAM Version 5 (commercially available) was fine-tuned and validated for laboratory quality measurements but not for measurements of the high-mass and heavily shielded SNM items encountered in NEST. FRAM is untested for spectra collected with high-granularity lower resolution instruments such as the new 8-MeV Detective-X favored by STAB or the new custom electrocooled systems coming into use for NEST. FRAM Version 6.1 (unreleased) has improvements in physics capabilities, and parameter sets may be adapted that are more specific to NEST and STAB, which is what we have attempted for this assignment. Thick shielding attenuates gamma rays profoundly, especially those at low energy, making them too weak to be measured. The missing low-energy peaks force the analysis to employ only the highest-energy peaks. We adapted FRAM 6.1 for analysis of plutonium spectra obtained with very thick Pb filters (a surrogate for NEST-type configurations). New parameter sets employing only very high energy peaks were created for the analysis. High granularity and low resolution make deconvolution of the 600-keV region particularly challenging, and we have worked to optimally extract information from this region. The results shown in this paper give high confidence that we are on the right track. We used a combination of real and synthetically-modified data. Remaining work includes testing the new software and parameters against genuine data collected with Detective-X and new NEST systems, but such datasets at the moment are unavailable. It also remains to develop and test parameter sets specific to uranium and the new detectors.

07 ISOTOPE AND RADIATION SOURCES↗

Management of Fissionable Equivalent Mass Materials at ORNL - 20146

The US DOE manages an inventory of materials that contains a range of long-lived radioactive isotopes that were produced from the 1960's through the 1980's by irradiating targets in production reactors to produce special heavy isotopes for US DOE programmatic use, scientific research, and industrial and medical applications. Since the production reactors and enrichment facilities that produced many of these materials have been shut down, they are considered unique materials that are not likely to be produced again. ORNL uses these materials in US DoE's center for production, storage, and distribution of TRU isotopes (plutonium through californium) and other related nuclear research programs. ORNL also operates the High Flux Isotope Reactor, which provides a high neutron source for production of isotopes for medical, industrial, and nuclear research programs. As a result, ORNL has an inventory of radioisotopes that are being managed for ongoing research programs and being held for reuse because they have potential intrinsic value to US DOE. An initiative is underway at ORNL to better manage these materials, particularly focusing on those with high fissionable equivalent mass that could impact the ability to perform ongoing or new research projects. This paper describes the actions ORNL is taking to manage these inventories, many of which consist of TRU materials, through reuse and disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fitting $\overline{ν}$ for Minor Pu Isotopes

After successful fitting of prompt ν for 235 U, 238 U, and 239 Pu(n,f) using CGMF, we have moved on to the minor plutonium isotopes. Minor isotopes pose a greater challenge both because there is less data available and we do not, by default, have parametrizations in CGMF already. Initially, we had planned to mitigate these challenges—and provide consistency within CGMF—by taking a stepped approach to the optimization. Continuing from the 239 Pu work, we would then fit 241Pu(n,f) $\overline{ν}$, where there is also a number of experimental measurements, keeping consistency between the parameters that are included in the calculation for 239 Pu and 241 Pu. With these parametrizations settled, we could consistently optimize 240 Pu(n,f) $\overline{ν}$. Following that step, we would move on to 242 Pu(n,f) (and increasing neutron number) and 238 Pu(n,f) (and decreasing neutron number). By including the fissioning systems in this manner, we should be able to minimize the unknown parameters in CGMF. We were also able to develop systematics for the CGMF input parameters along the Pu isotopic chain. However, after studies in the beginning of FY23, where we found reasonable agreement between CGMF and experimental prompt neutron multiplicities for 238−242 Pu, using a compound mass dependent parametrization from, and from discussions with I. Stetcu and P. Talou, we instead performed the evaluation of all five isotopes simultaneously. For all parameters in CGMF, they are either the same for each compound nucleus, or have a dependence on the compound mass. The details of these updates are given in. This report builds upon those details. In this short report, we first give an example of how we have updated CGMF to include 240 Pu(n,f) and 242 Pu(n,f), keeping consistency with the current 239 Pu and 241 Pu calculations, but without rigorous optimization (Sec. 2). Then, we will show in Section 3 what experimental data exist for the various isotopes to provide some insight into why 241 Pu and 239 Pu are used as anchor points. The evaluation is detailed in Section 4, and the comparison between CGMF calculations using the evaluated parameters and other prompt observables besides average neutron multiplicity are discussed in Section 2.2. Finally, we present conclusions and future work in Section 5.

07 ISOTOPE AND RADIATION SOURCES↗

Fitting $\overline{\nu}$ for minor Pu isotopes

After successful fitting of prompt $\overline{\nu}$ for 235 U, 238 U, and 239 Pu(n,f) using CGMF, we will move on to the minor plutonium isotopes. Minor isotopes pose a greater challenge both because there is less data available and we do not, by default, have parametrizations in CGMF already. To mitigate these challenges— and provide consistency within CGMF—we will take a stepped approach to the optimization. Continuing from the 239 Pu work, we will then fit 241 Pu(n,f) $\overline{\nu}$, where there is also a number of experimental measurements, keeping consistency between the parameters that are included in the calculation for 239 Pu and 241 Pu. With these parametrizations settled, we can consistently optimize 240 Pu(n,f) $\overline{\nu}$. Following that step, we will move on to 242 Pu(n,f) (and increasing neutron number) and 238 Pu(n,f) (and decreasing neutron number). By including the fissioning systems in this manner, we should be able to minimize the unknown parameters in CGMF. We will possibly also be able to develop systematics for the CGMF input parameters along the Pu isotopic chain. This work can serve as a guide to broadening the reactions available in CGMF. In this short report, we first give an example of how we have updated CGMF to include 240 Pu(n,f) and 242 Pu(n,f), keeping consistency with the current 239 Pu and 241 Pu calculations, but without rigorous optimization (Sec. 2). Then, we will shown in Section 3 what experimental data exist for the various isotopes to provide some insight into why 241 Pu and 239 Pu are used as anchor points.

07 ISOTOPE AND RADIATION SOURCES↗

Functionalized Polymer Thin Films for Plutonium Capture and Isotopic Screening from Aqueous Sources

The rapid screening of plutonium from aqueous sources remains a critical challenge for nuclear nonproliferation efforts. The determination of trace-level Pu isotopes in water requires offsite sample preparation and analysis; therefore, new methods that combine plutonium purification, concentration, and isotopic screening in a fieldable detection system will provide an invaluable tool for nuclear safeguards. This contribution describes the development and characterization of thin polymer-ligand films for the isolation and concentration of waterborne Pu for direct spectroscopic analyses. Submicron thin films were prepared through spin coating onto Si wafers and consisted of combinations of polystyrene (PS) with dibenzoylmethane, thenoyltrifluoroacetone, and di(2-ethylhexyl)phosphoric acid (HDEHP). Pu uptake studies from solutions at pH from 2.3 to 6.3 indicated that only films containing HDEHP exhibited significant recovery of Pu. High alpha spectroscopy peak energy resolutions were achieved for PS-HDEHP films over a range of film thicknesses from 30 to 250 nm. Furthermore, a separate study was performed to evaluate uptake from a primarily Pu(V) solution where it was observed that doubling the HDEHP loading in the film increased uptake of Pu by an order of magnitude. X-ray photoelectron spectroscopy (XPS) analysis revealed that HDEHP was highly concentrated within the first few nanometers of the film at the higher loading. XPS analysis also revealed that, in the presence of water, HDEHP was stripped from the surface layer of the film at circumneutral pH. While significant losses of ligand were seen in all samples, higher loadings of HDEHP resulted in measurable amounts of ligand retained after a 12-h soak in water. Findings of this study are being used to guide the development of thin-film composite membrane-based detection methods for the rapid, fieldable analysis of Pu in water.

36 MATERIALS SCIENCE↗